Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 204
Filtrar
1.
Health Qual Life Outcomes ; 17(1): 80, 2019 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-31060567

RESUMO

BACKGROUND: This study aims to describe the short-term reactogenicity of the AS03-adjuvanted H5N1 vaccine expressed through adverse events (AEs) and quality-adjusted life-day (QALD) scores. The AEs are likely to be short-term and therefore the quality of life (QoL) questionnaire, SF-36v2, was administered daily to record changes over seven days. A more sensitive application of this instrument should allow for a better understanding of short-term tolerability of adjuvanted vaccines. METHODS: Participants (N = 50) received a 2-dose vaccination schedule. Solicited (collected daily: days 0 to 7 [post dose 1] and 21 to 28 [post dose 2]) and unsolicited (collected weekly until day 21) AEs were collected via diary cards. The QoL questionnaires were completed daily (days 0-6) and weekly (days 0, 6, 21, 27) after dose one. Questionnaire data were transformed into SF-6D scores to report QALDs. It was hypothesized post-hoc that the QALD and daily AEs scores should correlate if discrete QoL-changes were captured. RESULTS: Pain (92%) and muscle ache (66%) were the most commonly reported solicited local and general AEs respectively, neither increased in intensity nor in frequency after dose 2. No safety concerns were identified during the study. A correlation between the daily AEs and QALD scores existed (correlation coefficient, - 0.97 (p < 0.001)). The impact of the AEs scores on the QALD was marginal (- 0.02 max for one day). CONCLUSION: Similarly with other H5N1 studies, no safety concern was identified throughout the study. Some time-limited variations in QALD-scores were reported. Our results imply that daily administration of the SF-36v2 captures changes in QALD-scores. TRIAL REGISTRATION: ClinicalTrials.gov . NCT01788228. Registered 11 February 2013.


Assuntos
Adjuvantes Imunológicos/efeitos adversos , Vacinas contra Influenza/efeitos adversos , Influenza Humana/prevenção & controle , Qualidade de Vida/psicologia , Adjuvantes Imunológicos/administração & dosagem , Adulto , Feminino , Humanos , Virus da Influenza A Subtipo H5N1/imunologia , Vacinas contra Influenza/administração & dosagem , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Fatores de Tempo , Vacinação/efeitos adversos , Vacinação/psicologia
2.
Cells ; 13(6)2024 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-38534364

RESUMO

Lysophosphatidic acid (LPA) is a lipid mediator that binds to G-protein-coupled receptors, eliciting a wide variety of responses in mammalian cells. Lyso-phospholipids generated via phospholipase A2 (PLA2) can be converted to LPA by a lysophospholipase D (lyso-PLD). Secreted lyso-PLDs have been studied in more detail than membrane-localized lyso-PLDs. This study utilized in vitro enzyme assays with fluorescent substrates to examine LPA generation in membranes from multiple mammalian cell lines (PC12, rat pheochromocytoma; A7r5, rat vascular smooth muscle; Rat-1, rat fibroblast; PC-3, human prostate carcinoma; and SKOV-3 and OVCAR-3, human ovarian carcinoma). The results show that membranes contain a lyso-PLD activity that generates LPA from a fluorescent alkyl-lyso-phosphatidylcholine, as well as from naturally occurring acyl-linked lysophospholipids. Membrane lyso-PLD and PLD activities were distinguished by multiple criteria, including lack of effect of PLD2 over-expression on lyso-PLD activity and differential sensitivities to vanadate (PLD inhibitor) and iodate (lyso-PLD inhibitor). Based on several lines of evidence, including siRNA knockdown, membrane lyso-PLD is distinct from autotaxin, a secreted lyso-PLD. PC-3 cells express GDE4 and GDE7, recently described lyso-PLDs that localize to membranes. These findings demonstrate that membrane-associated lyso-D activity, expressed by multiple mammalian cell lines, can contribute to LPA production.


Assuntos
Apoptose , Neoplasias Ovarianas , Diester Fosfórico Hidrolases , Masculino , Ratos , Humanos , Animais , Feminino , Linhagem Celular Tumoral , Membrana Celular , Mamíferos
3.
J Biol Chem ; 287(40): 33766-80, 2012 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-22879595

RESUMO

Many viruses encode scaffolding and coat proteins that co-assemble to form procapsids, which are transient precursor structures leading to progeny virions. In bacteriophage P22, the association of scaffolding and coat proteins is mediated mainly by ionic interactions. The coat protein-binding domain of scaffolding protein is a helix turn helix structure near the C terminus with a high number of charged surface residues. Residues Arg-293 and Lys-296 are particularly important for coat protein binding. The two helices contact each other through hydrophobic side chains. In this study, substitution of the residues of the interface between the helices, and the residues in the ß-turn, by aspartic acid was used examine the importance of the conformation of the domain in coat binding. These replacements strongly affected the ability of the scaffolding protein to interact with coat protein. The severity of the defect in the association of scaffolding protein to coat protein was dependent on location, with substitutions at residues in the turn and helix 2 causing the most significant effects. Substituting aspartic acid for hydrophobic interface residues dramatically perturbs the stability of the structure, but similar substitutions in the turn had much less effect on the integrity of this domain, as determined by circular dichroism. We propose that the binding of scaffolding protein to coat protein is dependent on angle of the ß-turn and the orientation of the charged surface on helix 2. Surprisingly, formation of the highly complex procapsid structure depends on a relatively simple interaction.


Assuntos
Bacteriófago P22/metabolismo , Sequência de Aminoácidos , Proteínas do Capsídeo/química , Dicroísmo Circular , Escherichia coli/virologia , Modelos Moleculares , Conformação Molecular , Dados de Sequência Molecular , Mutagênese Sítio-Dirigida , Mutação , Oligonucleotídeos/genética , Prófagos/genética , Ligação Proteica , Estrutura Secundária de Proteína , Estrutura Terciária de Proteína , Eletricidade Estática , Montagem de Vírus
4.
Nat Commun ; 14(1): 7233, 2023 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-37945698

RESUMO

Optically driven quantum materials exhibit a variety of non-equilibrium functional phenomena, which to date have been primarily studied with ultrafast optical, X-Ray and photo-emission spectroscopy. However, little has been done to characterize their transient electrical responses, which are directly associated with the functionality of these materials. Especially interesting are linear and nonlinear current-voltage characteristics at frequencies below 1 THz, which are not easily measured at picosecond temporal resolution. Here, we report on ultrafast transport measurements in photo-excited K3C60. Thin films of this compound were connected to photo-conductive switches with co-planar waveguides. We observe characteristic nonlinear current-voltage responses, which in these films point to photo-induced granular superconductivity. Although these dynamics are not necessarily identical to those reported for the powder samples studied so far, they provide valuable new information on the nature of the light-induced superconducting-like state above equilibrium Tc. Furthermore, integration of non-equilibrium superconductivity into optoelectronic platforms may lead to integration in high-speed devices based on this effect.

5.
Phys Med Biol ; 68(11)2023 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-37172608

RESUMO

Objective.4D dose reconstruction in proton therapy with pencil beam scanning (PBS) typically relies on a single pre-treatment 4DCT (p4DCT). However, breathing motion during the fractionated treatment can vary considerably in both amplitude and frequency. We present a novel 4D dose reconstruction method combining delivery log files with patient-specific motion models, to account for the dosimetric effect of intra- and inter-fractional breathing variability.Approach.Correlation between an external breathing surrogate and anatomical deformations of the p4DCT is established using principal component analysis. Using motion trajectories of a surface marker acquired during the dose delivery by an optical tracking system, deformable motion fields are retrospectively reconstructed and used to generate time-resolved synthetic 4DCTs ('5DCTs') by warping a reference CT. For three abdominal/thoracic patients, treated with respiratory gating and rescanning, example fraction doses were reconstructed using the resulting 5DCTs and delivery log files. The motion model was validated beforehand using leave-one-out cross-validation (LOOCV) with subsequent 4D dose evaluations. Moreover, besides fractional motion, fractional anatomical changes were incorporated as proof of concept.Main results.For motion model validation, the comparison of 4D dose distributions for the original 4DCT and predicted LOOCV resulted in 3%/3 mm gamma pass rates above 96.2%. Prospective gating simulations on the p4DCT can overestimate the target dose coverage V95%by up to 2.1% compared to 4D dose reconstruction based on observed surrogate trajectories. Nevertheless, for the studied clinical cases treated with respiratory-gating and rescanning, an acceptable target coverage was maintained with V95%remaining above 98.8% for all studied fractions. For these gated treatments, larger dosimetric differences occurred due to CT changes than due to breathing variations.Significance.To gain a better estimate of the delivered dose, a retrospective 4D dose reconstruction workflow based on motion data acquired during PBS proton treatments was implemented and validated, thus considering both intra- and inter-fractional motion and anatomy changes.


Assuntos
Neoplasias Pulmonares , Terapia com Prótons , Humanos , Terapia com Prótons/métodos , Estudos Retrospectivos , Estudos Prospectivos , Tomografia Computadorizada Quadridimensional/métodos , Movimento (Física) , Carmustina , Planejamento da Radioterapia Assistida por Computador/métodos
6.
J Synchrotron Radiat ; 19(Pt 6): 1001-5, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23093761

RESUMO

Eiger is the next-generation single-photon-counting pixel detector following the widely used Pilatus detector. Its smaller pixel size of 75 µm × 75 µm, higher frame rate of up to 22 kHz, and practically zero dead-time (~4 µs) between exposures will further various measurement methods at synchrotron sources. In this article Eiger's suitability for X-ray photon correlation spectroscopy (XPCS) is demonstrated. By exploiting its high frame rate, complementary small-angle X-ray scattering (SAXS) and XPCS data are collected in parallel to determine both the structure factor and collective diffusion coefficient of a nano-colloid suspension. For the first time, correlation times on the submillisecond time scale are accessible with a large-area pixel detector.

7.
Eur Phys J E Soft Matter ; 32(2): 127-34, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20596881

RESUMO

Multiarm star polymers were used as model grafted colloidal particles with long hairs, to study their size variation due to osmotic forces arising from added linear homopolymers of smaller size. This is the origin of the depletion phenomenon that has been exploited in the past as a means to melt soft colloidal glasses by adding linear chains and analyzed using dynamic light scattering experiments and an effective interactions analysis yielding the depletion potential. Shrinkage is a generic phenomenon for hairy particles, which affects macroscopic properties and state transitions at high concentrations. In this work we present a small-angle neutron scattering study of star/linear polymer mixtures with different size ratios (varying the linear polymer molar mass) and confirm the depletion picture, i.e., osmotic star shrinkage. Moreover, we find that as the linear/star polymer size ratio increases for the same effective linear volume fraction (c/c* with c* the overlapping concentration), the star shrinkage is reduced whereas the onset of shrinkage appears to take place at higher linear polymer volume fractions. A theoretical description of the force balance on a star polymer in solution, accounting for the classic Flory contributions, i.e. elastic and excluded volume, as well as the osmotic force due to the linear chains, accurately predicts the experimental findings of reduced star size as a function of linear polymer concentration. This is done in a parameter-free fashion, in which the size of the cavity created by the star, and from which the chains are excluded, is related to the radius of the former from first principles.

8.
Nat Phys ; 16(1): 38-41, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31915458

RESUMO

Many non-equilibrium phenomena have been discovered or predicted in optically-driven quantum solids1. Examples include light-induced superconductivity2,3 and Floquet-engineered topological phases4-8. These are short lived effects that should lead to measurable changes in electrical transport, which can be characterized using an ultrafast device architecture based on photoconductive switches9. Here, we report the observation of a light-induced anomalous Hall effect in monolayer graphene driven by a femtosecond pulse of circularly polarized light. The dependence of the effect on a gate potential used to tune the Fermi level reveals multiple features that reflect a Floquet-engineered topological band structure4,5, similar to the band structure originally proposed by Haldane10. This includes an approximately 60 meV wide conductance plateau centered at the Dirac point, where a gap of equal magnitude is predicted to open. We find that when the Fermi level lies within this plateau, the estimated anomalous Hall conductance saturates around 1.8±0.4 e2/h.

9.
10.
J Chem Phys ; 130(15): 154903, 2009 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-19388768

RESUMO

We have applied small angle neutron scattering (SANS), diffusing wave spectroscopy (DWS), and dynamic light scattering (DLS) to investigate the phase diagram of a sterically stabilized colloidal system consisting of octadecyl grafted silica particles dispersed in toluene. This system is known to exhibit gas-liquid phase separation and percolation, depending on temperature T, pressure P, and concentration phi. We have determined by DLS the pressure dependence of the coexistence temperature and the spinodal temperature to be dP/dT=77 bar/K. The gel line or percolation limit was measured by DWS under high pressure using the condition that the system became nonergodic when crossing it and we determined the coexistence line at higher volume fractions from the DWS limit of turbid samples. From SANS measurements we determined the stickiness parameter tau(B)(P,T,phi) of the Baxter model, characterizing a polydisperse adhesive hard sphere, using a global fit routine on all curves in the homogenous regime at various temperatures, pressures, and concentrations. The phase coexistence and percolation line as predicted from tau(B)(P,T,phi) correspond with the determinations by DWS and were used to construct an experimental phase diagram for a polydisperse sticky hard sphere model system. A comparison with theory shows good agreement especially concerning the predictions for the percolation threshold. From the analysis of the forward scattering we find a critical scaling law for the susceptibility corresponding to mean field behavior. This finding is also supported by the critical scaling properties of the collective diffusion.

11.
J Chem Phys ; 130(8): 084503, 2009 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-19256611

RESUMO

We present an experimental study of short-time diffusion properties in fluidlike suspensions of monodisperse charge-stabilized silica spheres suspended in dimethylformamide. The static structure factor S(q), the short-time diffusion function D(q), and the hydrodynamic function H(q) have been probed by combining x-ray photon correlation spectroscopy experiments with static small-angle x-ray scattering. Our experiments cover the full liquid-state part of the phase diagram, including de-ionized systems right at the liquid-solid phase boundary. We show that the dynamic data can be consistently described by the renormalized density fluctuation expansion theory of Beenakker and Mazur over a wide range of concentrations and ionic strengths. In accordance with this theory and Stokesian dynamics computer simulations, the measured short-time properties cross over monotonically, with increasing salt content, from the bounding values of salt-free suspensions to those of neutral hard spheres. Moreover, we discuss an upper bound for the hydrodynamic function peak height of fluid systems based on the Hansen-Verlet freezing criterion.


Assuntos
Modelos Químicos , Transição de Fase , Reologia , Difusão , Dimetilformamida , Concentração Osmolar , Dióxido de Silício , Análise Espectral , Raios X
12.
Rev Sci Instrum ; 79(1): 013102, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18248017

RESUMO

We report on a high pressure cell with six optical windows which can be used up to 2 kbars for laser light scattering applications at scattering angles of 45 degrees , 90 degrees , and 135 degrees of liquid samples in a temperature range between -20 and 150 degrees C. The pressure transmitting medium is compressed nitrogen. The window material used is SF57 NSK, a glass with an extremely low stress optical coefficient in the order of about 10(-5) which allows thus to maintain the plane of polarization even under the action of high pressure. In order to demonstrate the functioning of the cell we show Rayleigh-Brillouin spectra of poly(methylphenylsiloxane) at different polarizations and pressures.

13.
Phys Med Biol ; 63(20): 205014, 2018 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-30234498

RESUMO

Patient specific verification (PSV) measurements for pencil beam scanning (PBS) proton therapy are resource-consuming and necessitate substantial beam time outside of clinical hours. As such, efforts to safely reduce the PSV-bottleneck in the clinical work-flow are of great interest. Here, capabilities of current PSV methods to ensure the treatment integrity were investigated and compared to an alternative approach of reconstructing the dose distribution directly from the machine control- or delivery log files with the help of an independent dose calculation (IDC). Scenarios representing a wide range of delivery or work-flow failures were identified (e.g. error in spot position, air gap or pre-absorber setting) and machine files were altered accordingly. This yielded 21 corrupted treatment files, which were delivered and measured with our clinical PSV protocol. IDC machine- and log file checks were also conducted and their sensitivity at detecting the errors compared to the measurements. Although some of the failure scenarios induced clinically relevant dose deviations in the patient geometry, the PSV measurement protocol only detected one out of 21 error scenarios. However, 11 and all 21 error scenarios were detected using dose reconstructions based on the log and machine files respectively. Our data suggests that, although commonly used in particle therapy centers, PSV measurements do a poor job detecting data transfer failures and imperfect delivery machine performance. Machine- and log-file IDCs have been shown to successfully detect erroneous work-flows and to represent a reliable addition to the QA procedure, with the potential to replace PSV.


Assuntos
Medicina de Precisão , Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Erros de Configuração em Radioterapia , Humanos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada
14.
Phys Med Biol ; 63(17): 175001, 2018 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-30010613

RESUMO

For radiotherapy, it is crucial to guarantee that the delivered dose matches the planned dose. Therefore, patient specific quality assurance (QA) of absolute dose distributions is necessary. Here, we investigate the potential of replacing patient specific QA for pencil beam scanned proton therapy with Monte Carlo simulations. First, the set-up of the automated Monte Carlo model is presented with an emphasis on the absolute dose validation. Second, the absolute dose results obtained from the Monte Carlo simulation for a comprehensive set of patient fields are compared to patient specific QA measurements. Absolute doses measured with the Farmer chamber are shown to be 1.4% higher than the doses measured with the Semiflex chamber. For single energy layers, Monte Carlo simulated doses are 2.1% ± 0.4% lower than the ones measured with the ionization chamber and 1.1% ± 1.0% lower than measurements compared to patient field verification measurements. After rescaling to account for this 1.1% discrepancy, 98 fields (94.2%) agree within 2% to measurements, the maximum difference being 2.3%. In conclusion, an automated, easy-to-use Monte Carlo calculation system has been set up. This system reproduced patient specific QA results over a wide range of cases, showing that the time consuming measurements could be reduced or even replaced using Monte Carlo simulations without jeopardizing treatment quality.


Assuntos
Simulação por Computador/normas , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Método de Monte Carlo , Terapia com Prótons/normas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/normas
15.
Exp Clin Endocrinol Diabetes ; 115(10): 647-53, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18058599

RESUMO

INTRODUCTION: Pancreas transplantation in diabetic patients can sustain insulin independence for years. The aim of the study was to measure the incidence of an impaired or diabetic glucose tolerance in patients after successful transplantation and analyse insulin resistance and insulin secretion. METHODS: 174 Type 1 diabetic recipients of simultaneous pancreas/kidney (SPK) transplants were investigated early (three months) and 95 patients late (five years) after transplantation using an oral glucose tolerance test combined with an iv arginine load. RESULTS: Although mean fasting blood glucose and HbA1c levels were within the normal range, only 65% of the patients displayed a normal glucose tolerance (NGT), whereas 25% had an impaired (IGT) and 10% showed a diabetic glucose tolerance (DGT). Fasting blood glucose and HbA1c values were significantly lower in patients with NGT compared to graft recipients with IGT or DGT, either three months or five years after SPK. Indicators of insulin resistance (fasting insulin, HOMA-IR, Matsuda/de Fronzo Index) were elevated in all graft recipients, but no differences were found between groups. In contrast insulin secretion was significantly reduced in patients with IGT and DGT early and late after transplantation. SUMMARY: Insulin resistance is a common feature after pancreas transplantation. However, either three months or five years after SPK abnormal glucose tolerance was mainly due to a reduced glucose- and arginine-induced secretory response of insulin.


Assuntos
Diabetes Mellitus Tipo 1/sangue , Jejum/sangue , Teste de Tolerância a Glucose , Resistência à Insulina , Insulina/sangue , Transplante de Rim , Transplante de Pâncreas , Adulto , Glicemia/análise , Diabetes Mellitus Tipo 1/terapia , Feminino , Seguimentos , Hemoglobinas Glicadas/análise , Humanos , Masculino
16.
Rev Sci Instrum ; 78(12): 125101, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18163743

RESUMO

We report on a high pressure cell to use with small angle neutron scattering (SANS) in a pressure range up to 500 MPa. The cell offers the new possibility to investigate liquid samples by a specially designed sample chamber, which allows changing of samples relatively easily. Since the cell construction uses sapphire as window material, also light scattering investigations can be performed simultaneously to the SANS measurements. In this article we describe the construction of a high pressure cell and we demonstrate the applicability of the construction for SANS in combination with dynamic light scattering showing data on the biological molecule lysozyme.

17.
Phys Med Biol ; 62(6): 2398-2416, 2017 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-28151727

RESUMO

Proton therapy, especially in the form of pencil beam scanning (PBS), allows for the delivery of highly conformal dose distributions for complex tumor geometries. However, due to scattering of protons inside the patient, lateral dose gradients cannot be arbitrarily steep, which is of importance in cases with organs at risk (OARs) in close proximity to, or overlapping with, planning target volumes (PTVs). In the PBS approach, physical pencil beams are planned using a regular grid orthogonal to the beam direction. In this work, we propose an alternative to this commonly used approach where pencil beams are placed on an irregular grid along concentric paths based on the target contour. Contour driven pencil beam placement is expected to improve dose confirmation by allowing the optimizer to best enhance the penumbra of irregularly shaped targets using edge enhancement. Its effectiveness has been shown to improve dose confirmation to the target volume and reduce doses to OARs in head-and-neck planning studies. Furthermore, the deliverability of such plans, as well as the dosimetric improvements over conventional grid-based plans, have been confirmed in first phantom based verifications.


Assuntos
Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Órgãos em Risco , Imagens de Fantasmas , Terapia com Prótons/normas , Doses de Radiação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/normas , Radioterapia de Intensidade Modulada/normas
18.
J Cardiovasc Surg (Torino) ; 47(4): 379-83, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16953156

RESUMO

As endovascular treatments improve, the inevitable progress will result in the abandonment of conventional bypasses. First and foremost in this regard is the use of above knee bypass, particularly with prosthetic graft material. Already, endovascular success approaches or exceeds the patency seen with this bypass technique. As a result, in centers with endovascular expertise in infrainguinal intervention, bypass surgery is increasingly being replaced by these techniques and conventional bypass surgery is disappearing. Over the next few years, above knee bypass will be replaced by endovascular techniques in most centers as our results with these techniques improve.


Assuntos
Artéria Femoral/cirurgia , Isquemia/cirurgia , Perna (Membro)/irrigação sanguínea , Artéria Poplítea/cirurgia , Anastomose Cirúrgica/métodos , Implante de Prótese Vascular , Humanos , Joelho , Resultado do Tratamento
19.
Cancer Res ; 49(22): 6174-9, 1989 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-2478281

RESUMO

The interaction of the mutagen 2-bromoacrolein (2BA) with DNA and thymidine was studied in vitro by reaction of [3-3H]2BA with thymidine, RNA, single-stranded DNA, and double-stranded DNA in phosphate buffer (pH 7.4). After purification of the nucleic acids, they were incubated at alkaline pH to convert any (hydroxybromo)propano(deoxy)-guanosine adducts to their dihydroxy analogues. After acid or enzymatic hydrolysis, the hydrolysates were analyzed by reversed-phase high-performance liquid chromatography. At a concentration of 1.6 mM, the fraction of 2BA that became covalently bound to DNA was 2.3% of the amount added. Only 3% of the radioactivity bound to DNA after extensive purification could be accounted for as cyclic 1,N2-(6,7-dihydroxy)-propanoguanine adducts. More 2BA became covalently bound to single-stranded DNA and RNA as compared with double-stranded DNA. However, high-performance liquid chromatographic analyses showed that formation of cyclic 1,N2-(6,7-dihydroxy)propanoguanine adducts was also a minor reaction with these macromolecules. Because these data showed that other type(s) of reaction(s) are more important in the reaction of 2BA with nucleic acids, we have investigated the reaction of 2BA with other nucleosides. It was found that 2BA reacted well with thymidine in vitro, and the major product was identified by 500 MHz 1H and 75.43 MHz 13C nuclear magnetic resonance and thermospray mass spectrometry as 3-(2"-bromo-3"-oxopropyl)thymidine. This adduct was unstable and decomposed upon storage. After enzymatic hydrolysis of [3H]2BA-modified double-stranded DNA and subsequent analysis of the hydrolysate by high-performance liquid chromatography, 22% of the covalently bound radioactivity to DNA coeluted with decomposition products of the 3-(bromooxypropyl)thymidine adduct. This indicates that reaction of 2BA with this nucleotide in DNA is a major reaction.


Assuntos
Acroleína , Aldeídos , DNA , Mutagênicos , Timidina , Animais , Radioisótopos de Carbono , Cromatografia Líquida de Alta Pressão , DNA/biossíntese , DNA/isolamento & purificação , DNA de Cadeia Simples , Desoxiguanosina/síntese química , Indicadores e Reagentes , Fígado/metabolismo , Regeneração Hepática , Espectroscopia de Ressonância Magnética/métodos , Estrutura Molecular , RNA/isolamento & purificação , Ratos , Timidina/metabolismo
20.
Phys Med Biol ; 61(3): 1171-81, 2016 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-26767316

RESUMO

Pencil beam scanning (PBS) proton therapy requires the delivery of many thousand proton beams, each modulated for position, energy and monitor units, to provide a highly conformal patient treatment. The quality of the treatment is dependent on the delivery accuracy of each beam and at each fraction. In this work we describe the use of treatment log files, which are a record of the machine parameters for a given field delivery on a given fraction, to investigate the integrity of treatment delivery compared to the nominal planned dose. The dosimetry-relevant log file parameters are used to reconstruct the 3D dose distribution on the patient anatomy, using a TPS-independent dose calculation system. The analysis was performed for patients treated at Paul Scherrer Institute on Gantry 2, both for individual fields and per series (or plan), and delivery quality was assessed by determining the percentage of voxels in the log file dose distribution within +/- 1% of the nominal dose. It was seen that, for all series delivered, the mean pass rate is 96.4%. Furthermore, this work establishes a correlation between the delivery quality of a field and the beam position accuracy. This correlation is evident for all delivered fields regardless of individual patient or plan characteristics. We have also detailed further usefulness of log file analysis within our clinical workflow. In summary, we have highlighted that the integrity of PBS treatment delivery is dependent on daily machine performance and is specifically highly correlated with the accuracy of beam position. We believe this information will be useful for driving machine performance improvements in the PBS field.


Assuntos
Terapia com Prótons/métodos , Qualidade da Assistência à Saúde , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Terapia com Prótons/instrumentação , Terapia com Prótons/normas , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA