Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Int J Comput Dent ; 22(4): 307-319, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31840139

RESUMO

AIM: To determine the scanning strategy that obtains the most accurate results for two intraoral scanners (IOS) in complete-arch digital impressions. Scan time was evaluated and correlated with scan strategies. MATERIALS AND METHOD: A custom model used as the reference standard was fabricated with teeth having dentin- and enamel-identical refractive indices simulating natural dentition. A reference scan of the custom typodont was obtained using an ATOS III Triple Scan 3D optical scanner. Two IOS setups - Omnicam v 5.1.0 and Primescan v 5.0.2 - were used for complete-arch scanning, each using 13 scanning strategies, obtaining 260 digital files (n = 10 per group), recording each scan time, converting all experimental scans to standard tessellation language (STL) format, and using a comprehensive metrology program to compare the reference standard scan with the experimental scans. Statistical analyses utilized Welch's unequal variances t test. RESULTS: Group M exhibited the lowest trueness and precision values (P < 0.05) for Primescan (47.5% of the average among all other groups) and the lowest trueness value (P < 0.05) for Omnicam (53.4% of the average among all other groups), where group B exhibited the lowest precision value (65.6% of the average among all other groups) with P < 0.05. Primescan featured a better trueness index (4.79 µm) than that of Omnicam (19.13 µm), with a statistically significant difference (P < 0.00001). Primescan, group M, also featured a better precision index (4.67 µm) than Omnicam, group B (16.75 µm), with a statistically significant difference (P < 0.00001). CONCLUSION: For both IOS systems, group M provided the lowest scanning times. For trueness and precision of complete-arch scans, group M was the dominant scanning strategy in Primescan, while there was no dominant strategy in Omnicam. Group M had the best scanning time for both IOS systems.


Assuntos
Técnica de Moldagem Odontológica , Modelos Dentários , Desenho Assistido por Computador , Arco Dental , Humanos , Imageamento Tridimensional
2.
J Prosthodont Res ; 66(3): 509-513, 2022 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-34789607

RESUMO

PURPOSE: This technical procedure describes the accuracy of "cut-out-rescan" and "data exchange by over scanning" on cast areas using computer-aided design and computer-aided manufacturing software and two intraoral scanners (IOSs). METHODS: A customized cast was used as a reference standard and scanned using an ATOS Triple Scan digitizer. Two IOS setups were used in three scanning groups, namely, the control, cut-out-rescan, and data exchange by over scanning groups. Sixty digital files (n = 10 per group) were obtained and converted into the standard tessellation language format. A metrology program was used to evaluate the difference in accuracy between the control group and the other groups using Welch's unequal variances t-test. CONCLUSION: For trueness and precision of complete arch scans, the present technique provides statistical evidence that using data exchange by over scanning and a Primescan IOS results in higher accuracy scans compared to using cut-out-rescan and a Primescan IOS. The cut-out-rescan procedure provides scans with higher accuracy when using an Omnicam IOS. This technique is simple and saves time in workflows using a Primescan IOS.


Assuntos
Técnica de Moldagem Odontológica , Modelos Dentários , Desenho Assistido por Computador , Imageamento Tridimensional , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA