Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Opt Lett ; 49(12): 3420-3423, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38875635

RESUMO

The development of efficient multilayer mirrors for the water window (a spectral region between absorption edges of carbon and oxygen, from 284 to 543 eV) remains a challenge. As the best candidate, the Cr/Sc multilayer provides maximum theoretical reflectivity of about 60% at near-normal incidence around the Sc L2,3 absorption edge (397 eV). However, the maximum measured peak reflectance published so far just slightly exceeds 20%. We report on a new (to the best of our knowledge) approach to design more efficient Cr/Sc-based multilayer coatings using the process of nitridation of chromium during deposition and adding boron carbide as a third material in the multilayer structure. We discuss our strategy of optimization of the CrN/B4C/Sc multilayer system based on experimental studies. The peak reflectance as high as 32% at 396 eV was measured with this type of coating, which is of main interest for various water window applications such as x-ray microscopy.

2.
J Synchrotron Radiat ; 28(Pt 3): 778-789, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33949986

RESUMO

Synchrotron radiation can induce sample damage, whether intended or not. In the case of sensitive samples, such as biological ones, modifications can be significant. To understand and predict the effects due to exposure, it is necessary to know the ionizing radiation dose deposited in the sample. In the case of aqueous samples, deleterious effects are mostly induced by the production of reactive oxygen species via water radiolysis. These species are therefore good indicators of the dose. Here the application of a microfluidic cell specifically optimized for low penetrating soft X-ray radiation is reported. Sodium benzoate was used as a fluorescent dosimeter thanks to its specific detection of hydroxyl radicals, a radiolytic product of water. Measurements at 1.28 keV led to the determination of a hydroxyl production yield, G(HO.), of 0.025 ±â€…0.004 µmol J-1. This result is in agreement with the literature and confirms the high linear energy transfer behavior of soft X-rays. An analysis of the important parameters of the microfluidic dosimetry cell, as well as their influences over dosimetry, is also reported.


Assuntos
Microfluídica , Síncrotrons , Dosímetros de Radiação , Radiometria , Raios X
3.
J Synchrotron Radiat ; 27(Pt 6): 1577-1589, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33147182

RESUMO

The impressive progress in the performance of synchrotron radiation sources is nowadays driven by the so-called `ultimate storage ring' projects which promise an unprecedented improvement in brightness. Progress on the detector side has not always been at the same pace, especially as far as soft X-ray 2D detectors are concerned. While the most commonly used detectors are still based on microchannel plates or CCD technology, recent developments of CMOS (complementary metal oxide semiconductor)-type detectors will play an ever more important role as 2D detectors in the soft X-ray range. This paper describes the capabilities and performance of a camera equipped with a newly commercialized backside-illuminated scientific CMOS (sCMOS-BSI) sensor, integrated in a vacuum environment, for soft X-ray experiments at synchrotron sources. The 4 Mpixel sensor reaches a frame rate of up to 48 frames s-1 while matching the requirements for X-ray experiments in terms of high-intensity linearity (>98%), good spatial homogeneity (<1%), high charge capacity (up to 80 ke-), and low readout noise (down to 2 e- r.m.s.) and dark current (3 e- per second per pixel). Performance evaluations in the soft X-ray range have been carried out at the METROLOGIE beamline of the SOLEIL synchrotron. The quantum efficiency, spatial resolution (24 line-pairs mm-1), energy resolution (<100 eV) and radiation damage versus the X-ray dose (<600 Gy) have been measured in the energy range from 40 to 2000 eV. In order to illustrate the capabilities of this new sCMOS-BSI sensor, several experiments have been performed at the SEXTANTS and HERMES soft X-ray beamlines of the SOLEIL synchrotron: acquisition of a coherent diffraction pattern from a pinhole at 186 eV, a scattering experiment from a nanostructured Co/Cu multilayer at 767 eV and ptychographic imaging in transmission at 706 eV.

4.
J Phys Chem A ; 124(10): 1896-1902, 2020 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-32118425

RESUMO

The description of the biological effects of ionizing radiation requires a good knowledge of the dose deposition processes at both the cellular and molecular scales. However, experimental studies on the energy deposition specificity of sub-keV electrons, produced by most radiations, including high-energy photons and heavy ions, are scarce. Soft X-rays (0.2-2 keV) are here used to probe the physical and physico-chemical events occurring upon exposure of liquid water to sub-keV electrons. Liquid water samples were irradiated with a monochromatic photon beam at the SOLEIL synchrotron. Hydroxyl radical quantification was conducted through HO• scavenging using benzoate to form fluorescent hydroxybenzoate. The yields of HO• radicals exhibit a minimum around 1.5 keV, in good agreement with indirect observation. Moreover, they are relatively independent of the benzoate concentration in the range investigated, which corresponds to scavenging times of 170 ns to 170 ps. These results provide evidence that sub-keV electrons behave as high linear energy transfer particles, since they are able to deposit tens to hundreds of electronvolts in nanometric volumes.

5.
J Synchrotron Radiat ; 25(Pt 2): 413-418, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29488920

RESUMO

This paper presents the performance of a single-photon-counting hybrid pixel X-ray detector with synchrotron radiation. The camera was evaluated with respect to time-resolved experiments, namely pump-probe-probe experiments held at SOLEIL. The UFXC camera shows very good energy resolution of around 1.5 keV and allows the minimum threshold setting to be as low as 3 keV keeping the high-count-rate capabilities. Measurements of a synchrotron characteristic filling mode prove the proper separation of an isolated bunch of photons and the usability of the detector in time-resolved experiments.

6.
Biochem J ; 473(12): 1805-19, 2016 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-27099340

RESUMO

The control protein Factor H (FH) is a crucial regulator of the innate immune complement system, where it is active on host cell membranes and in the fluid phase. Mutations impairing the binding capacity of FH lead to severe autoimmune diseases. Here, we studied the solution structure of full-length FH, in its free state and bound to the C3b complement protein. To do so, we used two powerful techniques, hydroxyl radical protein footprinting (HRPF) and chemical cross-linking coupled with mass spectrometry (MS), to probe the structural rearrangements and to identify protein interfaces. The footprint of C3b on the FH surface matches existing crystal structures of C3b complexed with the N- and C-terminal fragments of FH. In addition, we revealed the position of the central portion of FH in the protein complex. Moreover, cross-linking studies confirmed the involvement of the C-terminus in the dimerization of FH.


Assuntos
Fator H do Complemento/química , Fator H do Complemento/metabolismo , Radical Hidroxila/química , Pegadas de Proteínas/métodos , Humanos , Ligação Proteica , Multimerização Proteica , Estrutura Terciária de Proteína
7.
Opt Express ; 23(22): 28479-90, 2015 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-26561119

RESUMO

An interferogram conditioning procedure, for subsequent phase retrieval by Fourier demodulation, is presented here as a fast iterative approach aiming at fulfilling the classical boundary conditions imposed by Fourier transform techniques. Interference fringe patterns with typical edge discontinuities were simulated in order to reveal the edge artifacts that classically appear in traditional Fourier analysis, and were consecutively used to demonstrate the correction efficiency of the proposed conditioning technique. Optimization of the algorithm parameters is also presented and discussed. Finally, the procedure was applied to grating-based interferometric measurements performed in the hard X-ray regime. The proposed algorithm enables nearly edge-artifact-free retrieval of the phase derivatives. A similar enhancement of the retrieved absorption and fringe visibility images is also achieved.

8.
J Synchrotron Radiat ; 21(Pt 3): 497-501, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24763638

RESUMO

High-efficiency nanofocusing of hard X-rays using stacked multilevel Fresnel zone plates with a smallest zone width of 200 nm is demonstrated. The approach is to approximate the ideal parabolic lens profile with two-, three-, four- and six-level zone plates. By stacking binary and three-level zone plates with an additional binary zone plate, the number of levels in the optical transmission function was doubled, resulting in four- and six-level profiles, respectively. Efficiencies up to 53.7% focusing were experimentally obtained with 6.5 keV photons using a compact alignment apparatus based on piezoelectric actuators. The measurements have also been compared with numerical simulations to study the misalignment of the two zone plates.

9.
J Synchrotron Radiat ; 20(Pt 2): 293-9, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23412486

RESUMO

A distributed fast-acquisition system for synchronized multi-technique experiments is presented, in which the collection of metadata and the asynchronous merging of large data volumes from multiple detectors are managed as part of the data collection process. This fast continuous scanning scheme, named FLYSCAN, enables measurement of microscopy data on a timescale of milliseconds per pixel. Proof-of-principle multi-technique experiments, namely scanning X-ray fluorescence spectrometry combined with absorption, differential phase contrast and dark-field imaging, have been performed on biological and geological samples.


Assuntos
Microscopia de Varredura por Sonda/métodos , Espectrometria por Raios X/métodos , Síncrotrons , Animais , Diagnóstico por Imagem , Fósseis , França , Microscopia de Varredura por Sonda/instrumentação , Mariposas/ultraestrutura , Síncrotrons/instrumentação
10.
J Phys Chem B ; 127(19): 4277-4285, 2023 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-37140453

RESUMO

Soft X-rays behave like particles with high linear energy transfer, as they deposit a large amount of their energy in the nanometric range, triggered by inner-shell ionization. In water, this can lead to the formation of a doubly ionized water molecule (H2O2+) and the emission of two secondary electrons (photoelectron and Auger electron). Our focus lies on detecting and quantifying the superoxide (HO2°) production via the direct pathway, i.e., from the reaction between the dissociation product of H2O2+, i.e., the oxygen atom (∼4 fs), and the °OH radicals present in the secondary electron tracks. The HO2° yield for 1620 eV photons, via this reaction pathway, was found to be 0.005 (±0.0007) µmol/J (formed within the ∼ps range). Experiments were also performed to determine the yield of HO2° production via another (indirect) pathway, involving solvated electrons. The indirect HO2° yield, measured experimentally as a function of photon energy (from 1700 to 350 eV), resulted in a steep decrease at around 1280 eV and a minimum close to zero at 800 eV. This behavior in contradiction with the theoretical prediction reveals the complexity hidden in the intratrack reactions.

11.
J Synchrotron Radiat ; 19(Pt 3): 323-31, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22514165

RESUMO

The XPAD3S-CdTe, a CdTe photon-counting pixel array detector, has been used to measure the energy and the intensity of the white-beam diffraction from a lysozyme crystal. A method was developed to calibrate the detector in terms of energy, allowing incident photon energy measurement to high resolution (approximately 140 eV), opening up new possibilities in energy-resolved X-ray diffraction. In order to demonstrate this, Laue diffraction experiments were performed on the bending-magnet beamline METROLOGIE at Synchrotron SOLEIL. The X-ray energy spectra of diffracted spots were deduced from the indexed Laue patterns collected with an imaging-plate detector and then measured with both the XPAD3S-CdTe and the XPAD3S-Si, a silicon photon-counting pixel array detector. The predicted and measured energy of selected diffraction spots are in good agreement, demonstrating the reliability of the calibration method. These results open up the way to direct unit-cell parameter determination and the measurement of high-quality Laue data even at low resolution. Based on the success of these measurements, potential applications in X-ray diffraction opened up by this type of technology are discussed.


Assuntos
Cristalografia por Raios X/métodos , Muramidase/química , Animais , Calibragem , Galinhas , Fótons , Síncrotrons/instrumentação
12.
Opt Lett ; 36(8): 1398-400, 2011 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-21499369

RESUMO

We present in this Letter a type of quadriwave lateral shearing interferometer for x-ray phase imaging. This device is based on a phase chessboard, and we take advantage of the large spectrum of the source to produce interferograms with a propagation-invariant contrast. Such a grating has been created for hard x-ray interferometry and experimentally tested on a synchrotron beamline at Soleil.

13.
J Synchrotron Radiat ; 15(Pt 2): 134-9, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18296778

RESUMO

The recent development of short-wavelength optics (X/EUV, synchrotrons) requires improved metrology techniques in terms of accuracy and curvature dynamic range. In this article a stitching Shack-Hartmann head dedicated to be mounted on translation stages for the characterization of X-ray mirrors is presented. The principle of the instrument is described and experimental results for an X-ray toroidal mirror are presented. Submicroradian performances can be achieved and systematic comparison with a classical long-trace profiler is presented. The accuracy and wide dynamic range of the Shack-Hartmann long-trace-profiler head allow two-dimensional characterizations of surface figure and curvature with a submillimeter spatial resolution.

14.
Opt Lett ; 31(2): 199-201, 2006 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-16441029

RESUMO

We present what we believe to be the first automatic alignment of a synchrotron beamline by the Hartmann technique. Experiments were performed, in the soft-x-ray range (E=3 keV, lambda=0.414 nm), by using a four-actuator Kirkpatrick-Baez (KB) active optic. A system imaging the KB focal spot and a soft-x-ray Hartmann wavefront sensor were used alternatively to control the KB optic. The beam corrected with the help of the imaging system was used to calibrate the wavefront sensor. With both closed loops, we focused the beam into a 6.8 microm x 9 microm FWHM focal spot.

15.
Opt Lett ; 28(17): 1534-6, 2003 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-12956370

RESUMO

We report, for the first time to our knowledge, experimental demonstration of wave-front analysis via the Hartmann technique in the extreme ultraviolet range. The reference wave front needed to calibrate the sensor was generated by spatially filtering a focused undulator beam with 1.7- and 0.6-microm-diameter pinholes. To fully characterize the sensor, accuracy and sensitivity measurements were performed. The incident beam's wavelength was varied from 7 to 25 nm. Measurements of accuracy better than lambdaEUV/120 (0.11 nm) were obtained at lambdaEUV = 13.4 nm. The aberrations introduced by an additional thin mirror, as well as wave front of the spatially unfiltered incident beam, were also measured.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA