RESUMO
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).
Assuntos
Arritmias Cardíacas , Bradicardia , Morte Súbita Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Bradicardia/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/efeitos adversos , Desenho de Equipamento , Seguimentos , Marca-Passo Artificial/efeitos adversos , Tecnologia sem Fio , Arritmias Cardíacas/complicações , Arritmias Cardíacas/terapiaRESUMO
INTRODUCTION: The Centers for Medicare & Medicaid Services (CMS) required a shared decision-making (SDM) interaction, with an "independent" physician, before left atrial appendage closure (LAAC). The purpose of this study is to better understand how this requirement is implemented in clinical practice. METHODS: We surveyed LAAC-performing centers. The characteristics of respondent and nonrespondent hospitals were compared using the CMS Provider of Services File for 2017. RESULTS: We received 86 responses out of 269 surveys mailed (32%). Respondent and nonrespondent hospital affiliations were similar: mean hospital size 525 beds, 15% for-profit, and 34% teaching hospitals. Thirty-four respondents (39.5%) stated that the implanting physician conducts some or all of the SDM interactions. The percentage of patients who decide not to undergo LAAC after the SDM interaction was estimated at 8.1%. Out of 72 responses to an open-ended question about the benefit of the SDM interaction, 44 (61%) described the requirement in negative terms, of which most felt the requirement was burdensome for patients and providers. Only 28 respondents (39%) described the requirement in positive or mixed terms. CONCLUSION: In violation of the letter of the CMS policy for LAAC, implanting physicians perform the SDM interaction at nearly 40% of responding hospitals. Most respondents felt the SDM requirement was burdensome for patients. More detailed guidance from CMS on how to comply with the policy may result in better alignment between the intent of the policy and how it is implemented.
Assuntos
Apêndice Atrial , Fibrilação Atrial , Tomada de Decisão Clínica , Tomada de Decisão Compartilhada , Humanos , Apêndice Atrial/cirurgia , Apêndice Atrial/fisiopatologia , Estados Unidos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Medicare , Pesquisas sobre Atenção à Saúde , Participação do Paciente , Padrões de Prática Médica , Centers for Medicare and Medicaid Services, U.S. , Procedimentos Cirúrgicos Cardíacos , Resultado do Tratamento , Oclusão do Apêndice Atrial EsquerdoRESUMO
BACKGROUND: Early guidance recommended a bolus of intravenous heparin at the beginning of leadless pacemaker (LP) implantation procedures. However, due to concern about bleeding complications, more recent practice has tended toward omitting the bolus and only running a continuous heparin infusion through the introducer sheath. The impact of omitting the heparin bolus on procedural outcomes is not clear. METHODS: We reviewed all Medtronic Micra LP implants at our institution from 9/2014 to 9/2022. The decision to bolus with heparin was at operator discretion. RESULTS: Among 621 LP implants, 326 received an intravenous heparin bolus, 243 did not, and 52 patients were excluded because heparin bolus status could not be confirmed. There was a trend toward more frequent omission of the heparin bolus with more recent implants. Median follow-up after LP implant was 14.3 (interquartile range [IQR]: 8.4-27.9) months. There was no difference between heparin bolus and no bolus groups in the number of device deployments/recaptures (1.42 ± 0.81 vs. 1.31 ± 0.66, p = .15). Implant-related adverse events were also similar between heparin bolus and no bolus groups: access-site hematoma requiring intervention (7 vs. 5, p = .99), pseudoaneurysm (1 vs. 1, p = .99), cardiac perforation (1 vs. 1, p = .99), intraprocedural device thrombus formation (2 vs. 4, p = .41), 30-day rehospitalization (21 vs. 15, p = .98), and 30-day all-cause mortality (16 vs. 14, p = .70). There was one additional nonfatal cardiac perforation in a patient who was excluded due to unknown heparin bolus status. Regarding device electrical parameters between heparin bolus and no bolus groups, there were no significant differences at the time of implant: pacing capture threshold 0.5 ± 0.4 vs. 0.5 ± 0.3, p = .10; pacing impedance 739.9 ± 226.4 vs. 719.1 ± 215.4, p = .52; R wave sensing 11.7 ± 5.7 vs. 12.0 ± 5.4, p = .34). Long-term device performance was also similar between groups. CONCLUSION: Omission of the systemic heparin bolus at the time of LP implantation appears safe in appropriately selected patients. Heparin bolus may still be considered in long cases requiring multiple device deployments or in patients at high risk for thrombotic complications.
Assuntos
Anticoagulantes , Estimulação Cardíaca Artificial , Heparina , Marca-Passo Artificial , Humanos , Heparina/administração & dosagem , Heparina/efeitos adversos , Masculino , Idoso , Feminino , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Resultado do Tratamento , Estudos Retrospectivos , Fatores de Tempo , Fatores de Risco , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Esquema de Medicação , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos , Desenho de PróteseRESUMO
INTRODUCTION: Transvenous leads have been implicated in tricuspid valve (TV) dysfunction, but limited data are available regarding the effect of extracting leads across the TV on valve regurgitation. The aim of this study is to quantify tricuspid regurgitation (TR) before and after lead extraction and identify predictors of worsening TR. METHODS: We studied 321 patients who had echocardiographic data before and after lead extraction. TR was graded on a scale (0 = none/trivial, 1 = mild, 2 = moderate, 3 = severe). A change of >1 grade following extraction was considered significant. RESULTS: A total of 321 patients underwent extraction of a total of 338 leads across the TV (1.05 ± 0.31 leads across the TV per patient). There was no significant difference on average TR grade pre- and postextraction (1.18 ± 0.91 vs. 1.15 ± 0.87; p = 0.79). TR severity increased after extraction in 84 patients, but was classified as significantly worse (i.e., >1 grade change in severity) in only 8 patients (2.5%). Use of laser lead extraction was associated with a higher rate of worsening TR postextraction (44.0% vs. 31.6%, p = 0.04). CONCLUSION: In our single-center analysis, extraction of leads across the TV did not significantly affect the extent of TR in most patients. Laser lead extraction was associated with a higher rate of worsening TR after extraction.
Assuntos
Remoção de Dispositivo , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/diagnóstico , Masculino , Feminino , Remoção de Dispositivo/efeitos adversos , Idoso , Resultado do Tratamento , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Desfibriladores Implantáveis , Fatores de Tempo , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Dispositivos de Terapia de Ressincronização CardíacaRESUMO
INTRODUCTION: To evaluate the cost and efficiency of suture-mediated percutaneous closure (SMC) compared to manual compression (MC) after atrial fibrillation (AF) ablation. SMC has been demonstrated to be efficacious in reducing hemostasis and bedrest times after AF ablation. To date, randomized data comparing the direct and indirect cost between the two techniques have not been described. METHODS: We conducted a 1:1 randomized trial comparing SMC to MC following AF ablation. The primary endpoints have been previously published. However, secondary endpoints pertinent to indirect cost including complication rates, hospital utilization (i.e., delays in discharge, additional patient encounters, nursing utilization), pain, patient reported outcomes, as well as the direct costs of care associated with AF ablation were collected. We also performed secondary analysis of the primary endpoint to evaluate for a learning curve, and subgroups analysis comparing efficacy across different numbers of access sites and compared to those in the MC group with a figure-of-eight suture (Fo8), that could potentially have impacted the relative efficiency of the procedure. RESULTS: A total of 107 patients were randomized and included: 53 in the SMC group and 54 in MC. A learning curve was observed in the SMC group between the first and second half of the study group (p = 0.037), with no such difference in the MC group. After accounting for the number of access sites, time to hemostasis remained shorter in the SMC Group (p = 0.002). Compared to those in the Fo8 arm (n = 37), the time to hemostasis remained shorter in the SMC group (p = 0.001). Among those planned for same-day discharge, there were more delays in the MC group (31.5% vs. 11.3%, p = 0.0144). Rates of major and minor complications were similar between SMC and MC groups at discharge (p = 0.243) and 30 days (p = 1.00), as were nursing utilization, self-reported pain, and overall patient reported outcomes. The overall cost of care related to the procedure was similar between the MC and SMC groups ($56 533.65 [$45 699.47, $66 987.64] vs. $57 050.44 [$47 251.40, $66 426.34], p = 0.601). CONCLUSION: SMC has been shown to decrease time to hemostasis and ambulation and facilitate earlier same-day discharge after AF ablation without an increase in direct or indirect costs.
RESUMO
BACKGROUND: Most studies of device-detected atrial fibrillation (AF) have recommended indefinite anticoagulation once a patient crosses a particular threshold for AF duration or burden. However, durations and burdens are known to fluctuate over time, but little is known about the magnitude of spontaneous fluctuations and the potential impact on anticoagulation decisions. OBJECTIVE: To quantify spontaneous fluctuations in AF duration and burden in patients with implantable loop recorders (ILRs) METHODS: We reviewed all ILR interrogations for patients with non-permanent AF at our institution from 2018 to 2023. We excluded patients treated with rhythm control. The duration of longest AF episode at each interrogation was classified as < 6, 6-24, and > 24 h, and the AF burden reported at each interrogation was classified as < 2%, 2%-11.4%, and > 11.4%. RESULTS: Out of 156 patients, the mean age at ILR implant was 70.9 ± 12.5 years, CHA2DS2-VASc score was 4.2 ± 1.8, duration of ILR follow-up was 23.4 ± 11.2 months, and number of ILR interrogations per patient was 18.0 ± 8.9. The duration of longest AF episode at any point during follow-up was < 6 , 6-24 , and > 24 h in 110, 30, and 16 patients, respectively. Among the 30 patients with a longest AF episode of 6-24 h at some point during follow-up, out of 594 total ILR interrogations, only 75 (12%) showed a longest episode of 6-24 h. In the remaining 519 interrogations, the longest episode was < 6 h. In patients with a longest episode of > 24 h at any point during follow-up (n = 16), only 47 out of 320 total ILR interrogations (15%) showed an episode of > 24 h. When evaluating AF burden, 96, 38, and 22 patients had maximum reported AF burdens of < 2%, 2%-11.4%, and > 11.4% at any point during ILR follow-up. Among those with a maximum burden of 2%-11.4% at some point during follow-up (n = 38), out of 707 ILR interrogations, only 76 (11%) showed a burden of 2%-11.4%. In the remaining 631 interrogations, the burden was < 2%. In the 22 patients with a burden > 11.4% at some point during follow-up, only 80 out of 480 interrogations (17%) showed a burden of > 11.4%. In 65% of interrogations, the burden was < 2%. CONCLUSION: Significant, spontaneous fluctuations in AF burden and duration are common in patients with ILRs. Even in patients with AF episodes of 6-24 h or > 24 h at some point during follow-up, the vast majority of interrogations show episodes of < 6 h. Similarly, in patients with burdens of 2%-11.4% or > 11.4% at some point during follow-up, the vast majority of interrogations show burdens of < 2%. More data are needed to determine whether crossing an AF burden or duration threshold once is sufficient to merit lifelong anticoagulation or whether spontaneous fluctuations in AF burden and duration should impact anticoagulation decisions.
RESUMO
INTRODUCTION: Hemodynamic decompensation during catheter ablation occurs due to prolonged procedure time and irrigant delivery directly into the cardiac chambers. Real-time hemodynamic monitoring of patients undergoing catheter ablation procedures may identify patients at risk of decompensation; we set out to assess the feasibility of a novel, real-time, intracardiac pressure monitoring system using a standard irrigated ablation catheter. METHODS: We studied 13 consecutive who underwent pressure measurement of the left atrium (LA) and left ventricle (LV) via transeptal access with a Swan Ganz (SG) catheter followed by two commercially available irrigated ablation catheters. Pressure waveform data was extracted to compare LA peak pressure, LV peak systolic pressure, LV end-diastolic pressure, and waveform analysis. RESULTS: Comparison between the SG and ablation catheters (AblA; AblB) demonstrated that LV systolic pressure (0.61-16.8 mmHg; 1.32-18.2 mmHg), and LV end-diastolic pressure (-3.4 to 2.8 mmHg; -3.0 to 3.35 mmHg) were well correlated and had accepted repeatability. Ablation waveforms demonstrated an 89.9 ± 6.4% correlation compared to SG waveforms. CONCLUSION: Pressure measurements derived from an irrigated ablation catheter are accurate and reliable when compared to an SG catheter. Further studies are needed to determine how real-time pressure monitoring can improve outcomes during ablation procedures.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Hemodinâmica , Átrios do Coração/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Catéteres , Resultado do TratamentoRESUMO
INTRODUCTION: Permanent pacing indications are common after cardiac surgery and transcatheter structural valve interventions. Leadless pacemakers (LPs) have emerged as a useful alternative to transvenous pacemakers. However, current commercially available LPs are unable to provide atrial pacing or cardiac resynchronization and relatively little is known about LP outcomes after cardiac surgery and transcatheter valve interventions. METHODS: This retrospective study included patients who received a Micra VR (MicraTM MC1VR01) or Micra AV (MicraTM MC1AVR1) (Medtronic) leadless pacemaker following cardiac surgery or transcatheter structural valve intervention between September 2014 and September 2022. Device performance and clinical outcomes, including ventricular pacing burden, ejection fraction, and need for conversion to transvenous pacing systems, were evaluated during follow-up. RESULTS: A total of 78 patients were included, of whom 40 received a Micra VR LP implant, and 38 received a Micra AV LP implant. The mean age of the cohort was 65.9 ± 17.9 years, and 48.1% were females. The follow-up duration for the entire cohort was 1.3 ± 1.1 years: 1.6 ± 1.3 years for the Micra VR group and 0.8 ± 0.5 years for the Micra AV group. Among the cohort, 50 patients had undergone cardiac surgery and 28 underwent transcatheter structural valve interventions. Device electrical performance was excellent during follow-up, with a small but clinically insignificant increase in ventricular pacing threshold and a slight decrease in pacing impedance. The mean right ventricle pacing (RVP) burden significantly decreased over time in the entire cohort (74.3% ± 37.2% postprocedure vs. 47.7% ± 40.6% at last follow-up, p < .001), and left ventricle ejection fraction (LVEF) showed a modest but significant downward trend during follow-up (55.0% ± 10.6% vs. 51.5% ± 11.2% p < .001). Patients with Micra VR implants had significantly reduced LVEF during follow-up (54.1% ± 11.9% vs. 48.8% ± 11.9%, p = .003), whereas LVEF appeared stable in the Micra AV group during follow-up (56.1% ± 9.0% vs. 54.6% ± 9.7%, p = .06). Six patients (7.7%) required conversion to transvenous pacing systems, four who required cardiac resynchronization for drop in LVEF with high RVP burden and two who required dual-chamber pacemakers for symptomatic sinus node dysfunction. CONCLUSION: Leadless pacemakers provide a useful alternative to transvenous pacemakers in appropriately selected patients after cardiac surgery and transcatheter structural valve interventions. Device performance is excellent over medium-term follow-up. However, a significant minority of patients require conversion to transvenous pacing systems for cardiac resynchronization or atrial pacing support, demonstrating the need for close electrophysiologic follow-up in this cohort.
Assuntos
Procedimentos Cirúrgicos Cardíacos , Marca-Passo Artificial , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Estudos Retrospectivos , Lipopolissacarídeos , Resultado do Tratamento , Desenho de Equipamento , Estimulação Cardíaca Artificial/efeitos adversosRESUMO
INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.
Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgiaRESUMO
AIMS: The mechanisms of transition from regular rhythms to ventricular fibrillation (VF) are poorly understood. The concordant to discordant repolarization alternans pathway is extensively studied; however, despite its theoretical centrality, cannot guide ablation. We hypothesize that complex repolarization dynamics, i.e. oscillations in the repolarization phase of action potentials with periods over two of classic alternans, is a marker of electrically unstable substrate, and ablation of these areas has a stabilizing effect and may reduce the risk of VF. To prove the existence of higher-order periodicities in human hearts. METHODS AND RESULTS: We performed optical mapping of explanted human hearts obtained from recipients of heart transplantation at the time of surgery. Signals recorded from the right ventricle endocardial surface were processed to detect global and local repolarization dynamics during rapid pacing. A statistically significant global 1:4 peak was seen in three of six hearts. Local (pixel-wise) analysis revealed the spatially heterogeneous distribution of Periods 4, 6, and 8, with the regional presence of periods greater than two in all the hearts. There was no significant correlation between the underlying restitution properties and the period of each pixel. CONCLUSION: We present evidence of complex higher-order periodicities and the co-existence of such regions with stable non-chaotic areas in ex vivo human hearts. We infer that the oscillation of the calcium cycling machinery is the primary mechanism of higher-order dynamics. These higher-order regions may act as niduses of instability and may provide targets for substrate-based ablation of VF.
Assuntos
Ventrículos do Coração , Coração , Humanos , Arritmias Cardíacas , Fibrilação Ventricular/cirurgia , Potenciais de Ação/fisiologiaRESUMO
AIMS: Single-connector (DF4) defibrillator leads have become the predominantly implanted transvenous implantable cardioverter-defibrillator lead. However, data on their long-term performance are derived predominantly from manufacturer product performance reports. METHODS AND RESULTS: We reviewed medical records in 5289 patients with DF4 leads between 2011 and 2023 to determine the frequency of lead-related abnormalities. We defined malfunction as any single or combination of electrical abnormalities requiring revision including a sudden increase (≥2×) in stimulation threshold, a discrete jump in high-voltage impedance, or sensing of non-physiologic intervals or noise. We documented time to failure, predictors of failure, and management strategies. Mean follow-up after implant was 4.15 ± 3.6 years (median = 3.63), with 37% of leads followed for >5 years. A total of 80 (1.5%) leads demonstrated electrical abnormalities requiring revision with an average time to failure of 4 ± 2.8 years (median = 3.5). Of the leads that malfunctioned, 62/80 (78%) were extracted and replaced with a new lead and in the other 18 cases, malfunctioned DF4 leads were abandoned, and a new lead implanted. In multivariable models, younger age at implant (OR 1.03 per year; P < 0.001) and the presence of Abbott/St. Jude leads increased the risk of malfunction. CONCLUSION: DF4 defibrillator leads demonstrate excellent longevity with >98.3% of leads followed for at least 5 years still functioning normally. Younger age at implant and lead manufacturer are associated with an increased risk of DF4 lead malfunction. The differences in lead survival between manufacturers require further investigation.
Assuntos
Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Falha de Equipamento , Estudos RetrospectivosRESUMO
BACKGROUND: Shared decision-making using a decision aid is required for patients undergoing implantation of primary prevention implantable cardioverter-defibrillators (ICD). It is unknown how much this process has impacted patients' experiences or choices. Effective shared decision-making requires an understanding of how patients make ICD decisions. A qualitative key informant study was chosen to capture the breadth of patients' experiences making ICD decisions in the context of required shared decision-making. METHODS AND RESULTS: We conducted in-depth interviews with 20 patients referred to electrophysiology clinics for the consideration of primary prevention ICD implantation. Purposeful sampling from a prior survey study evaluating mandated shared decision-making was based on patient characteristics and responses to the initial survey questions. Qualitative descriptive analysis of the interviews was performed using a multilevel coding strategy. Patients' paths to an ICD decision often involved multiple visits with multiple clinicians. However, the decision aid was almost exclusively provided to the patient during electrophysiology clinic visits. Some patients used the numeric data in the decision aid to make an ICD decision based on the risk-benefit profile; others made decisions based on other data or based on trust in clinicians' recommendations. Patients highlighted information related to living with the device as particularly important in helping them to make their ICD decisions. Some patients struggled with the emotional aspects of making an ICD decision. CONCLUSIONS: Patients' ICD decision-making paths poses a challenge to episodic shared decision-making and may make tools such as decision aids perfunctory if used solely during the electrophysiology visit. Understanding patients' ICD decision-making paths, especially in the context of encounters with primary cardiologists, can inform the implementation strategies of shared decision-making help to enhance its impact. Components of decision aids focusing on the experience of living with an ICD rather than probabilistic data may also be more impactful, although the nature of their impact will differ.
Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Tomada de Decisões , Tomada de Decisão Compartilhada , Humanos , Prevenção Primária , Medição de Risco , Inquéritos e QuestionáriosRESUMO
BACKGROUND: As targeted treatments for amyloid transthyretin cardiomyopathy (ATTR-CM) are becoming available, we aim to characterize the rates of ventricular arrhythmias (VAs), implantable cardioverter-defibrillator (ICD) utilization, and their impact on survival. METHODS: This is a retrospective cohort study of 130 patients with ATTR-CM diagnosed at Emory University's Cardiac Amyloidosis Center between April 2012 and September 2020. VAs were defined as nonsustained or sustained ventricular tachycardia and ventricular fibrillation. RESULTS: Of 130 patients, 42 had wild-type disease (wtATTR) and 88 had hereditary variants (hATTR), most commonly Val122Ile (89%). At ATTR-CM diagnosis, 80 (62%) patients had EF ≤ 40% consistent with systolic heart failure. Of the 69 (53%) patients with documented VAs significantly higher rates occurred among those with EF ≤ 40% compared with EF > 40% (67% vs. 28%, p = .001). Thirty-two patients (25 hATTR, 7 wtATTR) had primary prevention ICDs implanted. Eight (25%) of these patients received appropriate ICD therapy while two (6%) experienced inappropriate therapy. Comparing patients with EF ≤ 35% with and without ICDs did not reveal any survival difference (3.3 ± 0.5 vs. 2.8 ± 0.4 years, p = .699). CONCLUSIONS: High rates of VAs and appropriate ICD therapy were found among a unique cohort of largely hereditary ATTR-CM patients with a high rate of systolic heart failure.
Assuntos
Amiloidose , Desfibriladores Implantáveis , Taquicardia Ventricular , Amiloidose/diagnóstico , Arritmias Cardíacas , Morte Súbita Cardíaca/prevenção & controle , Humanos , Pré-Albumina , Estudos RetrospectivosRESUMO
BACKGROUND: In 2018, the Centers for Medicare and Medicaid Services (CMS) mandated that patients considering implantation of an implantable cardioverter-defibrillator (ICD) for primary prevention of sudden cardiac death undergo shared decision-making (SDM) using a decision-aid. OBJECTIVE: To observe the impact of the CMS's mandate on core measures of SDM using a natural experiment. RESEARCH DESIGN, SUBJECTS, AND MEASURES: Patients who underwent implantation of a primary prevention ICD within the Emory Healthcare system between 2017-2019 (pre and post SDM mandate) were surveyed. Survey domains included knowledge about the ICD, decisional conflict, values-choice concordance, and engagement in decision-making. Patients who had an ICD implant after the mandate were also asked about their views of the decision aid (DA). Responses of patients who had ICD implanted prior to the mandate were compared to those after the mandate using either Student t test or Chi-Squared tests. RESULTS: Of 101 patients who completed the survey, 45 had an ICD placed before the mandate and 56 had an ICD placed after. There were no major differences between knowledge, decisional conflict, values choice concordance, or patient engagement. Compared to patients with ICDs placed before the mandate, patients with ICDs after the mandate were more likely to subjectively feel more informed about the benefits of the procedure but were less likely to be able to correctly identify the frequency of complications. CONCLUSIONS: Policy effects to promote SDM that solely focus on a decision-aid may not substantively impact patient centered care.
Assuntos
Morte Súbita Cardíaca/prevenção & controle , Tomada de Decisão Compartilhada , Desfibriladores Implantáveis , Prevenção Primária , Idoso , Centers for Medicare and Medicaid Services, U.S. , Técnicas de Apoio para a Decisão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Estados UnidosRESUMO
BACKGROUND: Whether insurance status influences practice patterns in implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy (CRT) defibrillators, when indicated, is not known. METHODS AND RESULTS: We analyzed the NCDR ICD Registry to evaluate associations of insurance status with guidelines-based receipt of CRT, as well as device-type, complication rates, and use of optimal medical therapy defined by guidelines. Among 798,028 patients with de novo ICD implants, we included only patients < 65 years (those older have Medicare) and excluded those admitted before 2006 (n=1,835) or with insurance coverage other than Medicare, Medicaid or private insurance (n=25,695) leaving 286,556 for analysis. Inverse probability of treatment weighting was used to control for imbalances between groups. Mean age was 53 years, 29% were female. Patients with private insurance and Medicare were more likely to receive CRT-D when indicated (79.6%, OR 1.19 95% CI 1.09-1.28, P <.001 and 78.5%, OR 1.11 95% CI 1.01-1.21 Pâ¯=â¯.03, respectively) compared to the uninsured (76.7%). The uninsured were also more likely than other groups to receive a single-chamber device. Complication rates did not differ. Uninsured patients were, however, more likely to receive optimal medical therapy, particularly in the subgroup receiving the implant for primary prevention. CONCLUSIONS: In propensity-weighted analysis, uninsured patients are less likely to receive CRT when indicated but more likely to be receiving optimal medical therapy at discharge. Reasons for differences in device implantation practices based on insurance status require further study.
Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/economia , Insuficiência Cardíaca/terapia , Cobertura do Seguro/economia , Prevenção Primária/métodos , Sistema de Registros , Feminino , Insuficiência Cardíaca/economia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos RetrospectivosRESUMO
Micra leadless pacemaker has progressed from a single chamber pacemaker that can deliver VVIR pacing to a pacing device that can provide atrio-ventricular (AV) synchrony via a unique pacing algorithm that relies on identifying mechanical atrial contraction. This novel algorithm has its own limitations and intricacies. In this paper, we review this algorithm, suggest steps for troubleshooting and programming these devices and provide clinical examples of Micra AV cases that required changes in programming for adequate tracking of atrial activity.
Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial , Algoritmos , Átrios do Coração , Ventrículos do Coração/diagnóstico por imagem , HumanosRESUMO
BACKGROUND: Data on the management of Micra transcatheter pacing system (TPS) at the time of an upgrade or during battery depletion is limited. OBJECTIVE: We sought to evaluate the management patterns of patients implanted with a Micra TPS during long-term follow-up. METHODS: We retrospectively identified patients who underwent Micra implantation from April 2014 to November 2019. We identified patients who underwent extraction (n = 11) or had an abandoned Micra (n = 12). RESULTS: We identified 302 patients who received a Micra during the period of the study. Mean age was 72.7 ± 15.4 years, 54.6% were men, and left ventricular ejection fraction was 51.9 ± 5.2%. Mean follow-up was 1105.5 ± 529.3 days. Procedural complications included pericardial tamponade (n = 1) treated with pericardiocentesis, significant rise in thresholds (n = 6) treated with reimplantation (n = 4), and major groin complications (n = 2). Indications for extraction included an upgrade to cardiac resynchronization therapy (CRT) device (n = 3), bridging after extraction of an infected transvenous system (n = 3), elevated thresholds (n = 3), and non-Micra-related bacteremia (n = 2). The median time from implantation to extraction was 78 days (interquartile range: 14-113 days), with the longest extraction occurring at 1442 days. All extractions were successful, with no procedural or long-term complications. Indications for abandonment included the need for CRT (n = 6), battery depletion (n = 2), increasing thresholds/failure to capture (n = 3), and pacemaker syndrome (n = 1). All procedures were successful, with no procedural or long-term complications. CONCLUSION: In this large single-center study, 6% of patients implanted with a Micra required a system modification during long-term follow-up, most commonly due to the requirement for CRT pacing. These patients were managed successfully with extraction or abandonment.
Assuntos
Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Animais , Desenho de Equipamento , Humanos , Estágios do Ciclo de Vida , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular EsquerdaRESUMO
Pacing induced cardiomyopathy (PICM) is most commonly defined as a drop in left ventricle ejection fraction (LVEF) in the setting of chronic, high burden right ventricle (RV) pacing. Recent data suggest, however, that some individuals may experience the onset of heart failure symptoms more acutely after pacemaker implantation. Definitions of PICM which emphasize drop in LVEF may underestimate the incidence of deleterious effects from RV pacing. Treatment of PICM has primarily focused on upgrade to cardiac resynchronization therapy (CRT) when LVEF has dropped. However, emerging data suggest that conduction system pacing (CSP) may offer an opportunity to prevent PICM in the first place.
Assuntos
Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Cardiomiopatias/etiologia , Volume Sistólico , Função Ventricular Esquerda , Animais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Cardiomiopatias/diagnóstico , Cardiomiopatias/fisiopatologia , Cardiomiopatias/prevenção & controle , Humanos , Fatores de Risco , Resultado do Tratamento , Função Ventricular DireitaRESUMO
BACKGROUND: Women undergoing atrial fibrillation catheter ablation (AFCA) have higher rates of vascular complications and major bleeding. However, most studies have been underpowered to detect differences in rarer complications such as stroke/transient ischemic attack (TIA) and procedural mortality. METHODS: We performed a systematic review of databases (PubMed, World of Science, and Embase) to identify studies published since 2010 reporting AFCA complications by sex. Six complications of interest were (1) vascular/groin complications; (2) pericardial effusion/tamponade; (3) stroke/TIA; (4) permanent phrenic nerve injury; (5) major bleeding; and (6) procedural mortality. For meta-analysis, random effects models were used when heterogeneity between studies was ≥50% (vascular complications and major bleeding) and fixed effects models for other endpoints. RESULTS: Of 5716 citations, 19 studies met inclusion criteria, comprising 244,353 patients undergoing AFCA, of whom 33% were women. Women were older (65.3 ± 11.2 vs. 60.4 ± 13.2 years), more likely hypertensive (60.6% vs. 55.5%) and diabetic (18.3% vs. 16.5%), and had higher CHA2 DS2 -VASc scores (3.0 ± 1.8 vs. 1.4 ± 1.4) (p < .0001 for all comparisons). The rates of all six complications were significantly higher in women. However, despite statistically significant differences, the overall incidences of major complications were very low in both sexes: stroke/TIA (women 0.51% vs. men 0.39%) and procedural mortality (women 0.25% vs. men 0.19%). CONCLUSION: Women experience significantly higher rates of AFCA complications. However, the incidence of major procedural complications is very low in both sexes. The higher rate of complications in women may be partially attributable to older age and a higher prevalence of comorbidities at the time of ablation. More detailed studies are needed to better define the mechanisms of increased risk in women and to identify strategies for closing the sex gap.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Hemorragia , Humanos , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/epidemiologia , Ataque Isquêmico Transitório/etiologia , Masculino , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologiaRESUMO
BACKGROUND: There are limited data on cardiac implantable electronic device implantation (CIED) in patients with persistent left superior vena cava (PLSVC). OBJECTIVE: To describe the outcomes of implanting CIEDs with a focus on cardiac resynchronization therapy (CRT) in patients with PLSVC. METHODS: We identified all patients with a PLSVC that underwent CIED implantation from December 2008 until February 2019 at our institution by querying the electronic medical record (n = 34). We then identified controls in a 3:1 fashion (n = 102) by matching on device type (CRT vs non-CRT). Procedure success, complications, fluoroscopy and procedural time were recorded. Outcomes were compared using a two-way analysis of variance test and conditional regression modeling for continuous and categorical variables, respectively. RESULTS: A total of 34 patients with PLSVC underwent 38 procedures. Four patients underwent dual chamber system implantation followed by a subsequent upgrade to CRT. Thirteen patients underwent CRT implantation: one was implanted via the right subclavian while the rest were implanted via the PLSVC. Left ventricular (P = .06). Procedure and fluoroscopy times were significantly higher in the PLSVC as compared with the control group (97.7 vs 66.1 minute, P < .001 and 18.1 minute vs 8.7 minutes, P = .005, respectively). CONCLUSION: CIED implant in patients with PLSVC is feasible but technically more challenging and appears to be associated with higher risk of right ventricular lead dislodgment.