Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Lett ; 40(7): 1342-5, 2015 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-25831328

RESUMO

Monitoring of radiocarbon (C14) in carbon dioxide is demonstrated using mid-infrared spectroscopy and a quantum cascade laser. The measurement is based on cavity ring-down spectroscopy, and a high sensitivity is achieved with a simple setup. The instrument was tested using a standardized sample containing elevated levels of radiocarbon. Radiocarbon dioxide could be detected from samples with an isotopic ratio C14/C as low as 50 parts-per-trillion, corresponding to an activity of 5 kBq/m(3) in pure CO(2), or 2 Bq/m(3) in air after extraction of the CO(2) from an air sample. The instrument is simple, compact, and robust, making it the ideal tool for on-site measurements. It is aimed for monitoring radioactive gaseous emissions in a nuclear power environment, during the operation and decommissioning of nuclear power plants. Its high sensitivity also makes it the ideal tool for the detection of leaks in radioactive waste repositories.

2.
Opt Lett ; 40(8): 1822-5, 2015 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-25872083

RESUMO

Future transportable optical clocks require compact and reliable light sources. Here, broadband, unpolarized repumper and state clearout sources for Sr+ single-ion optical clocks are reported. These turn-key devices require no frequency stabilization or external modulators. They are fiber based, inexpensive, and compact. Key characteristics for clock operation are presented, including optical spectra, induced light shifts, and required extinction ratios. Tests with an operating single-ion standard show a clearout efficiency of 100%. Compared to a laser-based repumper, the achievable fluorescence rates for ion detection are a few tens of percent lower. The resulting ion kinetic temperature is 1-1.5 mK, near the Doppler limit of the ion system. Similar repumper light sources could be made for Ca+ (866 nm) and Ba+ (650 nm) using semiconductor gain media.

3.
Opt Express ; 17(6): 4890-6, 2009 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-19293920

RESUMO

We report an optical single-frequency synthesizer at the 1.55 microm telecommunications band. Output from a continuous-wave external cavity diode laser is frequency doubled and phase locked to a predetermined component of a Ti:S laser frequency comb. The synthesizer is capable of generating a single user-specified frequency from an atomic time base within the 192-196 THz gain bandwidth of an erbium-doped fiber amplifier. By tuning the repetition rate of the femtosecond laser the synthesized optical frequency can be swept with sub-kilohertz step size. Frequency sweeps of several GHz are realized by automatically re-locking the diode laser to adjacent comb components during frequency sweep. We demonstrate the operation of the device by presenting results of Doppler-free spectroscopy on acetylene using synthesized frequencies.

4.
Opt Lett ; 34(17): 2619-21, 2009 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-19724510

RESUMO

An optical frequency synthesizer is used for saturation spectroscopy of acetylene near 1540 nm. In the synthesizer, a user-specified frequency is generated from an atomic time base by phase locking the second harmonic of a cw near-IR external-cavity diode laser (ECDL) to a Ti:sapphire frequency comb. By stepping the repetition rate of the frequency comb, the ECDL frequency is swept over an acetylene transition in a saturated absorption spectroscopy setup. Hence, a spectral lineshape is measured with an absolute frequency scale. Line-center frequencies determined by fitting theoretical line profiles to the measured data are in good agreement with values measured with the ECDL stabilized to acetylene by third-harmonic locking and with the values recommended by the International Committee for Weights and Measures (CIPM).

5.
Artigo em Inglês | MEDLINE | ID: mdl-26863657

RESUMO

We used precise point positioning, a well-established GPS carrier-phase frequency transfer method to perform a direct remote comparison of two optical frequency standards based on single laser-cooled [Formula: see text] ions operated at the National Physical Laboratory (NPL), U.K. and the Physikalisch-Technische Bundesanstalt (PTB), Germany. At both institutes, an active hydrogen maser serves as a flywheel oscillator which is connected to a GPS receiver as an external frequency reference and compared simultaneously to a realization of the unperturbed frequency of the (2)S1/2(F=0)-(2)D3/2(F=2) electric quadrupole transition in [Formula: see text] via an optical femtosecond frequency comb. To profit from long coherent GPS-link measurements, we extrapolate the fractional frequency difference over the various data gaps in the optical clock to maser comparisons which introduces maser noise to the frequency comparison but improves the uncertainty from the GPS-link instability. We determined the total statistical uncertainty consisting of the GPS-link uncertainty and the extrapolation uncertainties for several extrapolation schemes. Using the extrapolation scheme with the smallest combined uncertainty, we find a fractional frequency difference [Formula: see text] of -1.3×10(-15) with a combined uncertainty of 1.2×10(-15) for a total measurement time of 67 h. This result is consistent with an agreement of the frequencies realized by both optical clocks and with recent absolute frequency measurements against caesium fountain clocks within the corresponding uncertainties.

6.
Appl Radiat Isot ; 81: 255-60, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23582494

RESUMO

In 2011 the joint research project Metrology for Radioactive Waste Management (MetroRWM)(1) of the European Metrology Research Programme (EMRP) started with a total duration of three years. Within this project, new metrological resources for the assessment of radioactive waste, including their calibration with new reference materials traceable to national standards will be developed. This paper gives a review on national, European and international strategies as basis for science-based metrological requirements in clearance and acceptance of radioactive waste.


Assuntos
Guias como Assunto , Proteção Radiológica/legislação & jurisprudência , Proteção Radiológica/normas , Resíduos Radioativos/legislação & jurisprudência , Resíduos Radioativos/prevenção & controle , Gerenciamento de Resíduos/legislação & jurisprudência , Gerenciamento de Resíduos/normas , Descontaminação/legislação & jurisprudência , Descontaminação/normas , Internacionalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA