Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Paediatr Anaesth ; 34(2): 167-174, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37955042

RESUMO

INTRODUCTION/BACKGROUND: Unmet need for seasonal influenza vaccination administration to pediatric patients exists at national and local levels. Vaccination during the perioperative period remains controversial, though opportunity exists to meet vaccination need through perioperative programs. The initial SMART Aim of this quality improvement initiative was to establish and increase seasonal influenza vaccination rate in eligible patients during in person preoperative clinic visits in a pediatric perioperative surgical home (PSH) to 10%. Informed by each prior season's experience, we increased our SMART Aim target for vaccinations in seasons two and three to 15 and 18%, respectively. METHODS: Following the Model for Improvement methodology, the PSH team developed and implemented a perioperative pediatric influenza vaccination program. Across three influenza seasons, key interventions included updates to organizational perioperative vaccination policy, obtaining material influenza vaccination supplies, development of EHR tools, PSH staff education, and communication with patient-families. Rate of eligible patients receiving influenza vaccination at their PSH clinic appointment was tracked over time. Influenza vaccination rates were reported monthly during Season 1, then weekly during seasons two and three. The balancing measure was same day surgery case cancellations related to influenza vaccination given at PSH clinic appointment. Statistical analysis methods utilized include Shewart's control chart and statistical process control (SPC) standards. Special cause variation was determined by eight or more consecutive data points above or below the centerline. RESULTS: The influenza vaccination rates in each of the three influenza seasons exceeded vaccination rate goals of 10, 15, and 18%, respectively. A total of 695 vaccines have been administered since program inception. No same day surgical case cancellations were observed as balancing measure. CONCLUSIONS: Over three consecutive influenza vaccination seasons, we safely established and met vaccination rate goals of 10, 15, and 18% to eligible patients during preoperative clinic visits within a pediatric PSH system. Through iterative PDSA cycles, we continue to identify opportunities for future improvement. This suggests that the perioperative period presents opportunity for seasonal influenza vaccination with potential program expansion to include routine vaccines of childhood.


Assuntos
Vacinas contra Influenza , Influenza Humana , Criança , Humanos , Influenza Humana/prevenção & controle , Melhoria de Qualidade , Vacinação , Estações do Ano
2.
Front Neurorobot ; 13: 80, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31632261

RESUMO

Stroke is a leading cause of long-term disability worldwide and often impairs walking ability. To improve recovery of walking function post-stroke, researchers have investigated the use of treatments such as fast functional electrical stimulation (FastFES). During FastFES treatments, individuals post-stroke walk on a treadmill at their fastest comfortable speed while electrical stimulation is delivered to two muscles of the paretic ankle, ideally to improve paretic leg propulsion and toe clearance. However, muscle selection and stimulation timing are currently standardized based on clinical intuition and a one-size-fits-all approach, which may explain in part why some patients respond to FastFES training while others do not. This study explores how personalized neuromusculoskeletal models could potentially be used to enable individual-specific selection of target muscles and stimulation timing to address unique functional limitations of individual patients post-stroke. Treadmill gait data, including EMG, surface marker positions, and ground reactions, were collected from an individual post-stroke who was a non-responder to FastFES treatment. The patient's gait data were used to personalize key aspects of a full-body neuromusculoskeletal walking model, including lower-body joint functional axes, lower-body muscle force generating properties, deformable foot-ground contact properties, and paretic and non-paretic leg neural control properties. The personalized model was utilized within a direct collocation optimal control framework to reproduce the patient's unstimulated treadmill gait data (verification problem) and to generate three stimulated walking predictions that sought to minimize inter-limb propulsive force asymmetry (prediction problems). The three predictions used: (1) Standard muscle selection (gastrocnemius and tibialis anterior) with standard stimulation timing, (2) Standard muscle selection with optimized stimulation timing, and (3) Optimized muscle selection (soleus and semimembranosus) with optimized stimulation timing. Relative to unstimulated walking, the optimal control problems predicted a 41% reduction in propulsive force asymmetry for scenario (1), a 45% reduction for scenario (2), and a 64% reduction for scenario (3), suggesting that non-standard muscle selection may be superior for this patient. Despite these predicted improvements, kinematic symmetry was not noticeably improved for any of the walking predictions. These results suggest that personalized neuromusculoskeletal models may be able to predict personalized FastFES training prescriptions that could improve propulsive force symmetry, though inclusion of kinematic requirements would be necessary to improve kinematic symmetry as well.

3.
PLoS One ; 12(7): e0179698, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28700708

RESUMO

Neuromusculoskeletal disorders affecting walking ability are often difficult to manage, in part due to limited understanding of how a patient's lower extremity muscle excitations contribute to the patient's lower extremity joint moments. To assist in the study of these disorders, researchers have developed electromyography (EMG) driven neuromusculoskeletal models utilizing scaled generic musculoskeletal geometry. While these models can predict individual muscle contributions to lower extremity joint moments during walking, the accuracy of the predictions can be hindered by errors in the scaled geometry. This study presents a novel EMG-driven modeling method that automatically adjusts surrogate representations of the patient's musculoskeletal geometry to improve prediction of lower extremity joint moments during walking. In addition to commonly adjusted neuromusculoskeletal model parameters, the proposed method adjusts model parameters defining muscle-tendon lengths, velocities, and moment arms. We evaluated our EMG-driven modeling method using data collected from a high-functioning hemiparetic subject walking on an instrumented treadmill at speeds ranging from 0.4 to 0.8 m/s. EMG-driven model parameter values were calibrated to match inverse dynamic moments for five degrees of freedom in each leg while keeping musculoskeletal geometry close to that of an initial scaled musculoskeletal model. We found that our EMG-driven modeling method incorporating automated adjustment of musculoskeletal geometry predicted net joint moments during walking more accurately than did the same method without geometric adjustments. Geometric adjustments improved moment prediction errors by 25% on average and up to 52%, with the largest improvements occurring at the hip. Predicted adjustments to musculoskeletal geometry were comparable to errors reported in the literature between scaled generic geometric models and measurements made from imaging data. Our results demonstrate that with appropriate experimental data, joint moment predictions for walking generated by an EMG-driven model can be improved significantly when automated adjustment of musculoskeletal geometry is included in the model calibration process.


Assuntos
Eletromiografia/métodos , Caminhada/fisiologia , Idoso , Humanos , Articulações/fisiologia , Masculino , Modelos Teóricos , Músculo Esquelético/fisiologia
4.
Artigo em Inglês | MEDLINE | ID: mdl-27790612

RESUMO

Researchers have explored a variety of neurorehabilitation approaches to restore normal walking function following a stroke. However, there is currently no objective means for prescribing and implementing treatments that are likely to maximize recovery of walking function for any particular patient. As a first step toward optimizing neurorehabilitation effectiveness, this study develops and evaluates a patient-specific synergy-controlled neuromusculoskeletal simulation framework that can predict walking motions for an individual post-stroke. The main question we addressed was whether driving a subject-specific neuromusculoskeletal model with muscle synergy controls (5 per leg) facilitates generation of accurate walking predictions compared to a model driven by muscle activation controls (35 per leg) or joint torque controls (5 per leg). To explore this question, we developed a subject-specific neuromusculoskeletal model of a single high-functioning hemiparetic subject using instrumented treadmill walking data collected at the subject's self-selected speed of 0.5 m/s. The model included subject-specific representations of lower-body kinematic structure, foot-ground contact behavior, electromyography-driven muscle force generation, and neural control limitations and remaining capabilities. Using direct collocation optimal control and the subject-specific model, we evaluated the ability of the three control approaches to predict the subject's walking kinematics and kinetics at two speeds (0.5 and 0.8 m/s) for which experimental data were available from the subject. We also evaluated whether synergy controls could predict a physically realistic gait period at one speed (1.1 m/s) for which no experimental data were available. All three control approaches predicted the subject's walking kinematics and kinetics (including ground reaction forces) well for the model calibration speed of 0.5 m/s. However, only activation and synergy controls could predict the subject's walking kinematics and kinetics well for the faster non-calibration speed of 0.8 m/s, with synergy controls predicting the new gait period the most accurately. When used to predict how the subject would walk at 1.1 m/s, synergy controls predicted a gait period close to that estimated from the linear relationship between gait speed and stride length. These findings suggest that our neuromusculoskeletal simulation framework may be able to bridge the gap between patient-specific muscle synergy information and resulting functional capabilities and limitations.

5.
Evolution ; 70(3): 687-95, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26867502

RESUMO

The coevolution of interacting species can lead to codependent mutualists. Little is known about the effect of selection on partners within verses apart from the association. Here, we determined the effect of selection on bacteria (Xenorhabdus nematophila) both within and apart from its mutualistic partner (a nematode, Steinernema carpocapsae). In nature, the two species cooperatively infect and kill arthropods. We passaged the bacteria either together with (M+), or isolated from (M-), nematodes under two different selection regimes: random selection (S-) and selection for increased virulence against arthropod hosts (S+). We found that the isolated bacteria evolved greater virulence under selection for greater virulence (M-S+) than under random selection (M-S-). In addition, the response to selection in the isolated bacteria (M-S+) caused a breakdown of the mutualism following reintroduction to the nematode. Finally, selection for greater virulence did not alter the evolutionary trajectories of bacteria passaged within the mutualism (M+S+ = M+S-), indicating that selection for the maintenance of the mutualism was stronger than selection for increased virulence. The results show that selection on isolated mutualists can rapidly breakdown beneficial interactions between species, but that selection within a mutualism can supersede external selection, potentially generating codependence over time.


Assuntos
Rabditídios/microbiologia , Simbiose , Xenorhabdus/fisiologia , Animais , Evolução Biológica
6.
Artigo em Inglês | MEDLINE | ID: mdl-26388740

RESUMO

Driven by the increasing channel count of neural probes, there is much effort being directed to creating increasingly scalable electrophysiology data acquisition (DAQ) systems. However, all such systems still rely on personal computers for data storage, and thus are limited by the bandwidth and cost of the computers, especially as the scale of recording increases. Here we present a novel architecture in which a digital processor receives data from an analog-to-digital converter, and writes that data directly to hard drives, without the need for a personal computer to serve as an intermediary in the DAQ process. This minimalist architecture may support exceptionally high data throughput, without incurring costs to support unnecessary hardware and overhead associated with personal computers, thus facilitating scaling of electrophysiological recording in the future.


Assuntos
Eletrofisiologia/instrumentação , Neurônios/fisiologia , Conversão Análogo-Digital , Animais , Computadores , Eletrofisiologia/métodos , Desenho de Equipamento , Internet , Masculino , Camundongos Endogâmicos C57BL , Software , Córtex Somatossensorial/fisiologia
7.
J Orthop Res ; 31(6): 921-9, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23280647

RESUMO

Mechanical loading is believed to be a critical factor in the development and treatment of knee osteoarthritis. However, the contact forces to which the knee articular surfaces are subjected during daily activities cannot be measured clinically. Thus, the ability to predict internal knee contact forces accurately using external measures (i.e., external knee loads and muscle electromyographic [EMG] signals) would be clinically valuable. We quantified how well external knee load and EMG measures predict internal knee contact forces during gait. A single subject with a force-measuring tibial prosthesis and post-operative valgus alignment performed four gait patterns (normal, medial thrust, walking pole, and trunk sway) to induce a wide range of external and internal knee joint loads. Linear regression analyses were performed to assess how much of the variability in internal contact forces was accounted for by variability in the external measures. Though the different gait patterns successfully induced significant changes in the external and internal quantities, changes in external measures were generally weak indicators of changes in total, medial, and lateral contact force. Our results suggest that when total contact force may be changing, caution should be exercised when inferring changes in knee contact forces based on observed changes in external knee load and EMG measures. Advances in musculoskeletal modeling methods may be needed for accurate estimation of in vivo knee contact forces.


Assuntos
Marcha , Articulação do Joelho/fisiologia , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Eletromiografia , Humanos , Masculino , Análise de Regressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA