RESUMO
OBJECTIVES: The aim of this study is to improve the reliability of subjective IQ assessment using a pairwise comparison (PC) method instead of a Likert scale method in abdominal CT scans. METHODS: Abdominal CT scans (single-center) were retrospectively selected between September 2019 and February 2020 in a prior study. Sample variance in IQ was obtained by adding artificial noise using dedicated reconstruction software, including reconstructions with filtered backprojection and varying iterative reconstruction strengths. Two datasets (each n = 50) were composed with either higher or lower IQ variation with the 25 original scans being part of both datasets. Using in-house developed software, six observers (five radiologists, one resident) rated both datasets via both the PC method (forcing observers to choose preferred scans out of pairs of scans resulting in a ranking) and a 5-point Likert scale. The PC method was optimized using a sorting algorithm to minimize necessary comparisons. The inter- and intraobserver agreements were assessed for both methods with the intraclass correlation coefficient (ICC). RESULTS: Twenty-five patients (mean age 61 years ± 15.5; 56% men) were evaluated. The ICC for interobserver agreement for the high-variation dataset increased from 0.665 (95%CI 0.396-0.814) to 0.785 (95%CI 0.676-0.867) when the PC method was used instead of a Likert scale. For the low-variation dataset, the ICC increased from 0.276 (95%CI 0.034-0.500) to 0.562 (95%CI 0.337-0.729). Intraobserver agreement increased for four out of six observers. CONCLUSION: The PC method is more reliable for subjective IQ assessment indicated by improved inter- and intraobserver agreement. CLINICAL RELEVANCE STATEMENT: This study shows that the pairwise comparison method is a more reliable method for subjective image quality assessment. Improved reliability is of key importance for optimization studies, validation of automatic image quality assessment algorithms, and training of AI algorithms. KEY POINTS: ⢠Subjective assessment of diagnostic image quality via Likert scale has limited reliability. ⢠A pairwise comparison method improves the inter- and intraobserver agreement. ⢠The pairwise comparison method is more reliable for CT optimization studies.
Assuntos
Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Tomografia Computadorizada por Raios X/métodos , Reprodutibilidade dos Testes , Pessoa de Meia-Idade , Estudos Retrospectivos , Variações Dependentes do Observador , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Algoritmos , SoftwareRESUMO
OBJECTIVES: To determine whether coronary computed tomography angiography (CCTA) can improve the diagnostic work-up of patients with acute chest pain and inconclusively high-sensitivity troponins (hs-troponin). METHODS: We conducted a prospective, blinded, observational, multicentre study. Patients aged 30-80 years presenting to the emergency department with acute chest pain and inconclusively elevated hs-troponins were included and underwent CCTA. The primary outcome was the diagnostic accuracy of ≥ 50% stenosis on CCTA to identify patients with type-1 non-ST-segment elevation acute coronary syndrome (NSTE-ACS). RESULTS: A total of 106 patients (mean age 65 ± 10, 29% women) were enrolled of whom 20 patients (19%) had an adjudicated diagnosis of type-1 NSTE-ACS. In 45 patients, CCTA revealed non-obstructive coronary artery disease (CAD) or no CAD. Sensitivity, specificity, negative predictive value (NPV), positive predictive value and area-under-the-curve (AUC) of ≥ 50% stenosis on CCTA to identify patients with type 1 NSTE-ACS, was 95% (95% confidence interval: 74-100), 56% (45-68), 98% (87-100), 35% (29-41) and 0.83 (0.73-0.94), respectively. When only coronary segments with a diameter ≥ 2 mm were considered for the adjudication of type 1 NSTE-ACS, the sensitivity and NPV increased to 100%. In 8 patients, CCTA enabled the detection of clinically relevant non-coronary findings. CONCLUSION: The absence of ≥ 50% coronary artery stenosis on CCTA can be used to rule out type 1 NSTE-ACS in acute chest pain patients with inconclusively elevated hs-troponins. Additionally, CCTA can help improve the diagnostic work-up by detecting other relevant conditions that cause acute chest pain and inconclusively elevated hs-troponins. CLINICAL RELEVANCE STATEMENT: Coronary CTA (CCTA) can safely rule out type 1 non-ST-segment elevation acute coronary syndrome (NSTE-ACS) in patients presenting to the ED with acute chest pain and inconclusively elevated hs-troponins, while also detecting other relevant non-coronary conditions. TRIAL REGISTRATION: Clinicaltrials.gov (NCT03129659). Registered on 26 April 2017 KEY POINTS: Acute chest discomfort is a common presenting complaint in the emergency department. CCTA achieved very high negative predictive values for type 1 NSTE-ACS in this population. CCTA can serve as an adjunct for evaluating equivocal ACS and evaluates for other pathology.
RESUMO
AIMS: Although electrical activity of the normal human heart is well characterized by the electrocardiogram, detailed insights into within-subject and between-subject variations of ventricular activation and recovery by noninvasive electroanatomic mapping are lacking. We characterized human epicardial activation and recovery within and between normal subjects using non-invasive electrocardiographic imaging (ECGI) as a basis to better understand pathology. METHODS AND RESULTS: Epicardial activation and recovery were assessed by ECGI in 22 normal subjects, 4 subjects with bundle branch block (BBB) and 4 with long-QT syndrome (LQTS). We compared characteristics between the ventricles [left ventricle (LV) and right ventricle (RV)], sexes, and age groups (<50/≥50years). Pearson's correlation coefficient (CC) was used for within-subject and between-subject comparisons. Age of normal subjects averaged 49 ± 14 years, 6/22 were male, and no structural/electrical heart disease was present. The average activation time was longer in LV than in RV, but not different by sex or age. Electrical recovery was similar for the ventricles, but started earlier and was on average shorter in males. Median CCs of between-subject comparisons of the ECG signals, activation, and recovery patterns were 0.61, 0.32, and 0.19, respectively. Within-subject beat-to-beat comparisons yielded higher CCs (0.98, 0.89, and 0.82, respectively). Activation and/or recovery patterns of patients with BBB or LQTS contrasted significantly with those found in the normal population. CONCLUSION: Activation and recovery patterns vary profoundly between normal subjects, but are stable individually beat to beat, with a male preponderance to shorter recovery. Individual characterization by ECGI at baseline serves as reference to better understand the emergence, progression, and treatment of electrical heart disease.
Assuntos
Potenciais de Ação , Bloqueio de Ramo , Eletrocardiografia , Síndrome do QT Longo , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/diagnóstico , Síndrome do QT Longo/fisiopatologia , Síndrome do QT Longo/diagnóstico , Frequência Cardíaca , Valor Preditivo dos Testes , Idoso , Estudos de Casos e Controles , Fatores de Tempo , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Fatores Etários , Mapeamento EpicárdicoRESUMO
Photon-counting detector computed tomography (PCD-CT) has emerged as a revolutionary technology in CT imaging. PCD-CT offers significant advancements over conventional energy-integrating detector CT, including increased spatial resolution, artefact reduction and inherent spectral imaging capabilities. In cardiac imaging, PCD-CT can offer a more accurate assessment of coronary artery disease, plaque characterisation and the in-stent lumen. Additionally, it might improve the visualisation of myocardial fibrosis through qualitative late enhancement imaging and quantitative extracellular volume measurements. The use of PCD-CT in cardiac imaging holds significant potential, positioning itself as a valuable modality that could serve as a one-stop-shop by integrating both angiography and tissue characterisation into a single examination. Despite its potential, large-scale clinical trials, standardisation of protocols and cost-effectiveness considerations are required for its broader integration into clinical practice. This narrative review provides an overview of the current literature on PCD-CT regarding the possibilities and limitations of cardiac imaging.
RESUMO
BACKGROUND: Patients with stable chest pain suspected of coronary artery disease (CAD) usually undergo multiple diagnostic tests to confirm or rule out obstructive CAD. Some tests may not effectively assess the presence of CAD, precluding optimal treatment. A diagnostic strategy of upfront computed tomography coronary angiography (CTCA) combined with optimal medical therapy (OMT) tailored to the extent of CAD may be superior to standard care in preventing major adverse cardiac events. STUDY DESIGN: The CLEAR-CAD trial is a prospective, open-label, multicentre, randomised, superiority trial of an upfront CTCA-guided strategy in 6444 patients presenting in an outpatient setting with suspected CAD compared with standard care, in approximately 30 participating centres in the Netherlands. The upfront CTCA-guided strategy consists of an initial CTCA which is assessed using the Coronary Artery Disease-Reporting and Data System (CAD-RADS 2.0). In patients without CAD (CAD-RADS 0) no specific cardiac medication is mandated. Patients with non-obstructive CAD (CAD-RADS 1-2) are treated with preventive OMT. Patients with obstructive CAD (CAD-RADS ≥â¯3) are treated with preventive and anti-anginal OMT; in the presence of pharmacologically refractory symptoms patients undergo selective revascularisation after non-invasive functional imaging for myocardial ischaemia (≥â¯10%). Patients with significant left main or proximal left anterior descending coronary artery stenosis on CTCA undergo direct invasive coronary angiography and subsequent revascularisation. The primary endpoint is the composite of all-cause death and myocardial infarction. CONCLUSION: The CLEAR-CAD trial is the first randomised study to investigate the efficacy of a combined upfront CTCA-guided medical and selective revascularisation strategy in an outpatient setting with suspected CAD compared with standard care.
RESUMO
AIMS: To illustrate the practical and technical challenges along with the safety aspects when performing MRI-guided electrophysiological procedures in a pre-existing diagnostic magnetic resonance imaging (MRI) environment. METHODS AND RESULTS: A dedicated, well-trained multidisciplinary interventional cardiac MRI team (iCMR team), consisting of electrophysiologists, imaging cardiologists, radiologists, anaesthesiologists, MRI physicists, electrophysiological (EP) and MRI technicians, biomedical engineers, and medical instrumentation technologists is a prerequisite for a safe and feasible implementation of CMR-guided electrophysiological procedures (iCMR) in a pre-existing MRI environment. A formal dry run "mock-up" to address the entire spectrum of technical, logistic, and safety issues was performed before obtaining final approval of the Board of Directors. With this process we showed feasibility of our workflow, safety protocol, and bailout procedures during iCMR outside the conventional EP lab. The practical aspects of performing iCMR procedures in a pre-existing MRI environment were addressed and solidified. Finally, the influence on neighbouring MRI scanners was evaluated, showing no interference. CONCLUSION: Transforming a pre-existing diagnostic MRI environment into an iCMR suite is feasible and safe. However, performing iCMR procedures outside the conventional fluoroscopic lab, poses challenges with technical, practical, and safety aspects that need to be addressed by a dedicated multi-disciplinary iCMR team.
Assuntos
Ablação por Cateter , Imagem por Ressonância Magnética Intervencionista , Fluoroscopia , Coração , Humanos , Imageamento por Ressonância Magnética/efeitos adversosRESUMO
OBJECTIVE: The aim of this study was to evaluate whether magnetic resonance imaging (MRI) can accurately identify poor responders after chemoradiotherapy (CRT) who will need to go straight to surgery, and to evaluate whether results are reproducible among radiologists with different levels of expertise. METHODS: Seven independent readers with different levels of expertise retrospectively evaluated the restaging MRIs (T2-weighted + diffusion-weighted imaging [T2W + DWI]) of 62 patients and categorized them as (1) poor responders - highly suspicious of tumor; (2) intermediate responders - tumor most likely; and (3) good - potential (near) complete responders. The reference standard was histopathology after surgery (or long-term follow-up in the case of a watch-and-wait program). RESULTS: Fourteen patients were complete responders and 48 had residual tumor. The median percentage of patients categorized by the seven readers as 'poor', 'intermediate', and 'good' responders was 21% (range 11-37%), 50% (range 23-58%), and 29% (range 23-42%), respectively. The vast majority of poor responders had histopathologically confirmed residual tumor (73% ypT3-4), with a low rate (0-5%) of 'missed complete responders'. Of the 14 confirmed complete responders, a median percentage of 71% were categorized in the MR-good response group and 29% were categorized in the MR-intermediate response group. CONCLUSIONS: Radiologists of varying experience levels should be able to use MRI to identify the ± 20% subgroup of poor responders who will definitely require surgical resection after CRT. This may facilitate more selective use of endoscopy, particularly in general settings or in centers with limited access to endoscopy.
Assuntos
Neoplasias , Preservação de Órgãos , Quimiorradioterapia , Humanos , Imageamento por Ressonância Magnética , Terapia Neoadjuvante , Neoplasias/diagnóstico por imagem , Neoplasias/cirurgia , Neoplasias/terapia , Seleção de Pacientes , Estudos Retrospectivos , Resultado do TratamentoRESUMO
BACKGROUND: Pericardial fat (PF) has been suggested to directly act on cardiomyocytes, leading to diastolic dysfunction. The aim of this study was to investigate whether a higher PF volume is associated with a lower diastolic function in healthy subjects. METHODS: 254 adults (40-70 years, BMI 18-35 kg/m2, normal left ventricular ejection fraction), with (a)typical chest pain (otherwise healthy) from the cardiology outpatient clinic were retrospectively included in this study. All patients underwent a coronary computed tomographic angiography for the measurement of pericardial fat volume, as well as a transthoracic echocardiography for the assessment of diastolic function parameters. To assess the independent association of PF and diastolic function parameters, multivariable linear regression analysis was performed. To maximize differences in PF volume, the group was divided in low (lowest quartile of both sexes) and high (highest quartile of both sexes) PF volume. Multivariable binary logistic analysis was used to study the associations within the groups between PF and diastolic function, adjusted for age, BMI, and sex. RESULTS: Significant associations for all four diastolic parameters with the PF volume were found after adjusting for BMI, age, and sex. In addition, subjects with high pericardial fat had a reduced left atrial volume index (p = 0.02), lower E/e (p < 0.01) and E/A (p = 0.01), reduced e' lateral (p < 0.01), reduced e' septal p = 0.03), compared to subjects with low pericardial fat. CONCLUSION: These findings confirm that pericardial fat volume, even in healthy subjects with normal cardiac function, is associated with diastolic function. Our results suggest that the mechanical effects of PF may limit the distensibility of the heart and thereby directly contribute to diastolic dysfunction. Trial registration NCT01671930.
Assuntos
Tecido Adiposo/fisiopatologia , Adiposidade , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda , Tecido Adiposo/diagnóstico por imagem , Adulto , Idoso , Doenças Assintomáticas , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estudos Transversais , Diástole , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologiaRESUMO
AIMS: An appropriate left ventricular (LV) lead position is a pre-requisite for response to cardiac resynchronization therapy (CRT) and is highly patient-specific. The purpose of this study was to develop a non-invasive pre-procedural CRT-roadmap to guide LV lead placement to a coronary vein in late-activated myocardium remote from scar. METHODS AND RESULTS: Sixteen CRT candidates were prospectively included. Electrocardiographic imaging (ECGI), computed tomography angiography (CTA), and delayed enhancement cardiac magnetic resonance imaging (DE-CMR) were integrated into a 3D cardiac model (CRT-roadmap) using anatomic landmarks from CTA and DE-CMR. Electrocardiographic imaging was performed using 184 electrodes and a CT-based heart-torso geometry. Coronary venous anatomy was visualized using a designated CTA protocol. Focal scar was assessed from DE-CMR. Cardiac resynchronization therapy-roadmaps were constructed for all 16 patients [left bundle branch block: n = 6; intraventricular conduction disturbance: n = 8; narrow-QRS (ablate and pace strategy); n = 1; right bundle branch block: n = 1]. The number of coronary veins ranged between 3 and 4 per patient. The CRT-roadmaps showed no (n = 5), 1 (n = 6), or 2 (n = 5) veins per patient located outside scar in late-activated myocardium [≥50% QRS duration (QRSd)]. Final LV lead position was outside scar in late-activated myocardium in 11 out of 14 implanted patients, while a LV lead in scar was unavoidable in the remaining three patients. CONCLUSION: A non-invasive pre-implantation CRT-roadmap was feasible to develop in a case series by integration of coronary venous anatomy, myocardial-scar localization, and epicardial electrical activation patterns, anticipating on clinically relevant features.
Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Doença do Sistema de Condução Cardíaco/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Imagem Cinética por Ressonância Magnética/métodos , Implantação de Prótese , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca , Feminino , Ventrículos do Coração , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos ProspectivosRESUMO
PURPOSE: To evaluate image quality using reduced contrast media (CM) volume in pre-TAVI assessment. METHODS: Forty-seven consecutive patients referred for pre-TAVI examination were evaluated. Patients were divided into two groups: group 1 BMI < 28 kg/m(2) (n = 29); and group 2 BMI > 28 kg/m(2) (n = 18). Patients received a combined scan protocol: retrospective ECG-gated helical CTA of the aortic root (80kVp) followed by a high-pitch spiral CTA (group 1: 70 kV; group 2: 80 kVp) from aortic arch to femoral arteries. All patients received one bolus of CM (300 mgI/ml): group 1: volume = 40 ml; flow rate = 3 ml/s, group 2: volume = 53 ml; flow rate = 4 ml/s. Attenuation values (HU) and contrast-to-noise ratio (CNR) were measured at the levels of the aortic root (helical) and peripheral arteries (high-pitch). Diagnostic image quality was considered sufficient at attenuation values > 250HU and CNR > 10. RESULTS: Diagnostic image quality for TAVI measurements was obtained in 46 patients. Mean attenuation values and CNR (HU ± SD) at the aortic root (helical) were: group 1: 381 ± 65HU and 13 ± 8; group 2: 442 ± 68HU and 10 ± 5. At the peripheral arteries (high-pitch), mean values were: group 1: 430 ± 117HU and 11 ± 6; group 2: 389 ± 102HU and 13 ± 6. CONCLUSION: CM volume can be substantially reduced using low kVp protocols, while maintaining sufficient image quality for the evaluation of aortic root and peripheral access sites. KEY POINTS: ⢠Image quality could be maintained using low kVp scan protocols. ⢠Low kVp protocols reduce contrast media volume by 34-67 %. ⢠Less contrast media volume lowers the risk of contrast-induced nephropathy.
Assuntos
Aorta/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos RetrospectivosRESUMO
PURPOSE: Ionizing radiation and iodinated contrast media are potential drawbacks to repetitive follow-up CT angiography in current practice. The aim of the present study was to optimize radiation dose and contrast agent volume by using individualized CT angiography protocols. MATERIALS AND METHODS: Eighty consecutive patients referred for CT angiography of the whole aorta were prospectively evaluated. Patients were divided into groups of patients with a body mass index (BMI) < 28 kg/m(2) (group 1; n = 50) and those with a BMI ≥ 28 kg/m(2) (group 2; n = 30). A control group consisted of 50 consecutive patients who were retrospectively evaluated. CT angiography parameters on a second-generation dual-source scanner were 128 × 0.6-mm collimation, pitch of 0.9, rotation time of 0.33 seconds, tube voltages of 80/100/120 kVp (group 1/group 2/control), reference tube current of 400 mA, and image reconstruction at 1-mm/0.8-mm slice thickness (kernels, B30f [control] and I30f/strength 3 [groups 1/2]). The control group received 120 mL of contrast agent (300 mgI/mL) at 4.8 mL/s; groups 1 and 2 received 44 mL and 53 mL at 3.3 mL/s and 4 mL/s, respectively. Effective dose was evaluated for each patient. Image quality was determined by qualitative image analysis at the levels of the thoracic, abdominal, and pelvic aorta as nondiagnostic, diagnostic, good, or excellent, and quantitative image analysis was performed, including attenuation values and contrast-to-noise ratio (CNR). RESULTS: Mean effective radiation dose values for CT angiography of the aorta were 3.7 mSv ± 0.7 in group 1, 6.7 mSv ± 1.4 in group 2, and 8.7 mSv ± 1.9 in the control group (P < .001). Mean attenuation values and CNR levels were 334 HU ± 66 and 16 ± 8, respectively, in group 1, 277 HU ± 56 and 14 ± 5 in group 2, and 305 HU ± 77 and 11 ± 4 in the control group. CONCLUSIONS: Iterative reconstruction algorithms resulted in 23%-57% less radiation in combination with 55%-63% less contrast agent volume compared with standard CT protocols.
Assuntos
Aorta/diagnóstico por imagem , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Idoso , Algoritmos , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Humanos , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-RuídoAssuntos
Doenças da Aorta/diagnóstico por imagem , Isquemia Encefálica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Cardiopatias/diagnóstico por imagem , Embolia Intracraniana/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Acidente Vascular Cerebral/diagnóstico por imagem , Trombose/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Doenças da Aorta/complicações , Apêndice Atrial/diagnóstico por imagem , Isquemia Encefálica/etiologia , Isquemia Encefálica/cirurgia , Procedimentos Endovasculares , Feminino , Coração/diagnóstico por imagem , Cardiopatias/complicações , Próteses Valvulares Cardíacas , Humanos , Embolia Intracraniana/etiologia , Embolia Intracraniana/cirurgia , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/complicações , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/cirurgia , Trombose/complicaçõesRESUMO
OBJECTIVES: To determine the optimal imaging time point for transcatheter aortic valve implantation (TAVI) therapy planning by comprehensive evaluation of the aortic root. METHODS: Multidetector-row CT (MDCT) examination with retrospective ECG gating was retrospectively performed in 64 consecutive patients referred for pre-TAVI assessment. Eighteen different parameters of the aortic root were evaluated at 11 different time points in the cardiac cycle. Time points at which maximal (or minimal) sizes were determined, and dimension differences to other time points were evaluated. Theoretical prosthesis sizing based on different measurements was compared. RESULTS: Largest dimensions were found between 10 and 20% of the cardiac cycle for annular short diameter (10%); mean diameter (10%); effective diameter and circumference-derived diameter (20%); distance from the annulus to right coronary artery ostium (10%); aortic root at the left coronary artery level (20%); aortic root at the widest portion of coronary sinuses (20%); and right leaflet length (20%). Prosthesis size selection differed depending on the chosen measurements in 25-75% of cases. CONCLUSION: Significant changes in anatomical structures of the aortic root during the cardiac cycle are crucial for TAVI planning. Imaging in systole is mandatory to obtain maximal dimensions. KEY POINTS: ⢠Most aortic root structures undergo significant dimensional changes throughout the cardiac cycle. ⢠The largest dimensions of aortic parameters should be determined to optimize TAVI. ⢠Circumference-derived diameter showed maximum dimension at 20% of the cardiac cycle.
Assuntos
Aorta Torácica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/patologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Tamanho do Órgão , Desenho de Prótese , Estudos Retrospectivos , SístoleRESUMO
OBJECTIVE: The purpose of this study was to systematically investigate radiation dose reduction using automated tube voltage selection during CT angiography (CTA) and to evaluate the impact of contrast medium (CM) injection protocols on dose reduction. MATERIALS AND METHODS: A circulation phantom containing the thoracic and abdominal vasculature was used. Four different concentrations of CM (iopromide 300 and 370 mg I/mL and iomeprol 350 and 400 mg I/mL) were administered while maintaining an identical iodine delivery rate (1.8 g I/s) and total iodine load (20.0 g). Three different scanning protocols for CTA of the thoracoabdominal aorta were used: protocol A, no dose modulation; protocol B, automated tube current modulation (CARE Dose4D); and protocol C, automated tube voltage selection (CARE kV). The dose-length product was recorded to calculate the effective dose. Attenuation values (in Hounsfield units), image noise levels, and signal-to-noise ratios (SNRs) in six predefined intravascular sites (three thoracic and three abdominal) were measured by two readers. All values were analyzed using the Kruskal-Wallis test and two-way ANOVA. RESULTS: There was a significant reduction in the effective dose (in millisieverts) for protocols B (mean ± SD, 2.03 ± 0.1 mSv) and C (1.00 ± 0.0 mSv) compared with protocol A (4.34 ± 0.0 mSv). The dose was reduced by 53% for protocol B and by 77% for protocol C. No significant differences were found in the effective dose among the different CM injection protocols within the scanning protocols; all p values were > 0.05. The attenuation values and SNRs were comparable among all the different CM injection protocols; all p values were > 0.05. CONCLUSION: A large radiation dose reduction (77%) can be achieved using automated tube voltage selection independent of the CM injection protocol.
Assuntos
Aortografia/métodos , Meios de Contraste/administração & dosagem , Iohexol/análogos & derivados , Iopamidol/análogos & derivados , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Aortografia/instrumentação , Humanos , Iohexol/administração & dosagem , Iopamidol/administração & dosagem , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/instrumentaçãoRESUMO
BACKGROUND: Previous research on the necessity to reduce the viscosity of contrast media (CM) by either prewarming CM before injection during computed tomography (CT) or by using less concentrated CM has yielded conflicting results. In addition, there is limited evidence on patient comfort. OBJECTIVES: The aim of the study was to examine if prewarming CM, with varying CM concentrations, is superior to CM at room temperature, with respect to patient comfort and safety in CT. MATERIALS AND METHODS: All elective patients scheduled for contrast-enhanced CT scans at Maastricht University Medical Center+ between October 27, 2021 and October 31, 2022 were eligible for inclusion when a questionnaire evaluating patient comfort was completed. This 1-year period was divided into 4 intervals (4 groups): group 1 (370 mg I/mL, 37°C), group 2 (370 mg I/mL, room temperature), group 3 (300 mg I/mL, 37°C), and group 4 (300 mg I/mL, room temperature). All CT scans were performed using state of the art equipment (Siemens Healthineers; SOMATOM Force and SOMATOM Definition AS, Forchheim, Germany). Contrast media injections were performed using a dual-head power injector (Stellant; Bayer Healthcare, Berlin, Germany) and individualized to body weight and/or tube voltage, depending on the CM protocols. After the CT scan, patients completed a questionnaire covering the primary outcomes comfort, pain, and adverse events such as feelings of heat, nausea, vomiting, itchiness, urticaria, difficulty breathing, dizziness, goosebumps, or an odd taste. Technicians were asked to report any adverse events, including extravasation and allergic-like reactions. The secondary outcome involved attenuation (in Hounsfield unit, HU), which was evaluated by assessing the HU of the coronary arteries for vascular CT, and liver enhancement in portal venous CT. The Kruskal-Wallis test was used for continuous scale outcomes and χ 2 tests for examining adverse events. RESULTS: Results showed no significant differences examining comfort score ( P = 0.054), pain sensation ( P = 0.469), extravasation ( P = 0.542), or allergic-like reaction ( P = 0.253). Significant differences among the 4 groups were found with respect to heat sensation and dizziness ( P = 0.005 and P = 0.047, respectively), showing small effect sizes. All other adverse effects showed no significant results. No significant differences were observed in coronary attenuation among the 4 groups in coronary CT angiography ( P = 0.113). When analyzing attenuation in portal venous CT scans, significant differences were found among the 4 groups ( P = 0.008). CONCLUSIONS: Administrating prewarmed CM is nonsuperior compared with CM at room temperature in relation to patient comfort and safety, regardless of CM concentration. These findings suggest that prewarming CM before usage is unnecessary, which will improve the efficiency of daily clinical workflow and brings environmentally friendly benefits.
Assuntos
Meios de Contraste , Conforto do Paciente , Temperatura , Tomografia Computadorizada por Raios X , Humanos , Masculino , Meios de Contraste/efeitos adversos , Feminino , Pessoa de Meia-Idade , Idoso , Inquéritos e Questionários , Viscosidade , Adulto , Segurança do Paciente , Estudos ProspectivosRESUMO
BACKGROUND: Dark-blood late gadolinium enhancement (LGE) cardiac magnetic resonance (CMR) has better correlation with bipolar voltage (BiV) to define ablation scar in the left atrium (LA) compared to conventional bright-blood LGE CMR. OBJECTIVES: This study sought to determine the optimal signal intensity threshold of dark-blood LGE CMR to identify LA ablation scar. METHODS: In 54 patients scheduled for atrial fibrillation ablation, image intensity ratios (IIRs) were derived from preprocedural dark-blood LGE CMR. In 26 patients without previous ablation, the upper limit of normal was derived from the 95th and 98th percentiles of pooled IIR values. In 28 patients with previous atrial fibrillation ablation, BiV was compared with the corresponding IIR. Receiver-operating characteristics analyses were employed to determine the optimal IIR threshold (ie, the point with the smallest distance to the upper left corner of the receiver-operating characteristics) for LA ablation scar (BiV ≤0.15 mV). RESULTS: Upper limit of normal corresponded to IIR values 1.16 and 1.21, yielding low sensitivities of 0.32 and 0.09 to detect LA ablation scar. Receiver-operating characteristics analysis of IIR and BiV comparison achieved a median area under the curve of 0.77. Median optimal IIR threshold for LA ablation scar was 1.09, with an average sensitivity of 0.73, specificity of 0.75, and accuracy of 0.71. Median IIR thresholds of 1.00 and 1.10 corresponded to 80% sensitivity and 80% specificity, respectively. There was considerable interpatient variability: optimal IIR thresholds per patient ranged from 1.01 to 1.22. CONCLUSIONS: The optimal IIR threshold to identify LA ablation scar by dark-blood LGE CMR is 1.09. Because of interpatient variability, the investigators recommend using a lower (1.00) and upper (1.10) threshold to prevent over- or underestimation of ablation scar.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Cicatriz , Átrios do Coração , Humanos , Feminino , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Masculino , Cicatriz/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Gadolínio , Imageamento por Ressonância Magnética , Meios de Contraste , Curva ROCRESUMO
PURPOSE: Pericardial fat (PF) and epicardial adipose tissue (EAT) may enhance the proinflammatory response in corona virus-19 (COVID-19) patients. Higher PF and EAT volumes might result in multiorgan failure and explain unfavorable trajectories.The aim of this study was to examine the association between the volume of PF and EAT and multiorgan failure over time. MATERIALS AND METHODS: All mechanically ventilated COVID-19 patients with an available chest computed tomography were prospectively included (March-June 2020). PF and EAT volumes were quantified using chest computed tomography scans. Patients were categorized into sex-specific PF and EAT tertiles. Variables to calculate Sequential Organ Failure Assessment (SOFA) scores were collected daily to indicate multiorgan failure. Linear mixed-effects regression was used to investigate the association between tertiles for PF and EAT volumes separately and serial SOFA scores over time. All models were adjusted. RESULTS: Sixty-three patients were divided into PF and EAT tertiles, with median PF volumes of 131.4 mL (IQR [interquartile range]: 115.7, 143.2 mL), 199.8 mL (IQR: 175.9, 221.6 mL), and 318.8 mL (IQR: 281.9, 376.8 mL) and median EAT volumes of 69.6 mL (IQR: 57.0, 79.4 mL), 107.9 mL (IQR: 104.6, 115.1 mL), and 163.8 mL (IQR: 146.5, 203.1 mL). Patients in the highest PF tertile had a statistically significantly lower SOFA score over time (1.3 [-2.5, -0.1], P =0.033) compared with the lowest PF tertile. EAT tertiles were not significantly associated with SOFA scores over time. CONCLUSION: A higher PF volume is associated with less multiorgan failure in mechanically ventilated COVID-19 patients. EAT volumes were not associated with multiorgan failure.
RESUMO
BACKGROUND: Coronary artery calcification (CAC) is associated with poor outcome in critically ill patients. A deterioration in cardiac conduction and loss of myocardial tissue could be an underlying cause. Vectorcardiography (VCG) and cardiac biomarkers provide insight into these underlying causes. The aim of this study was to investigate whether a high degree of CAC is associated with VCG-derived variables and biomarkers, including high-sensitivity troponin-T (hs-cTnT) and N-terminal pro-B-type natriuretic peptide (NT-proBNP). METHODS: Mechanically ventilated coronavirus-19 (COVID-19) patients with an available chest computed tomography (CT) and 12-lead electrocardiogram (ECG) were studied. CAC scores were determined using chest CT scans. Patients were categorized into 3 sex-specific tertiles: low, intermediate, and high CAC. Daily 12 leads-ECGs were converted to VCGs. Daily hs-cTnT and NT-proBNP levels were determined. Linear mixed-effects regression models examined the associations between CAC tertiles and VCG variables, and between CAC tertiles and hs-cTnT or NT-proBNP levels. RESULTS: In this study, 205 patients (73.2% men, median age 65 years [IQR 57.0; 71.0]) were included. Compared to the lowest CAC tertile, the highest CAC tertile had a larger QRS area at baseline (6.65 µVs larger [1.50; 11.81], p = 0.012), which decreased during admission (- 0.27 µVs per day [- 0.43; - 0.11], p = 0.001). Patients with the highest CAC tertile also had a longer QRS duration (12.02 ms longer [4.74; 19.30], p = 0.001), higher levels of log hs-cTnT (0.79 ng/L higher [0.40; 1.19], p < 0.001) and log NT-proBNP (0.83 pmol/L higher [0.30; 1.37], p = 0.002). CONCLUSION: Patients with a high degree of CAC had the largest QRS area and higher QRS amplitude, which decreased more over time when compared to patients with a low degree of CAC. These results suggest that CAC might contribute to loss of myocardial tissue during critical illness. These insights could improve risk stratification and prognostication of patients with critical illness.
RESUMO
Background: Delayed enhancement cardiac magnetic resonance (DE-CMR) is the reference standard for the non-invasive assessment of myocardial fibrosis. DE-CMR is able to distinguish ischaemic from non-ischaemic aetiologies based on differences in hyperenhancement distribution patterns. Hyperenhancement caused by ischaemic injury typically involves the endocardium, while hyperenhancement confined to the mid- and epicardial layers of the myocardium suggests a non-ischaemic aetiology. Case summary: This is a case of a 20-year-old male with an unremarkable medical history with an acute ST-elevation myocardial infarction. DE-CMR revealed two distinct patterns of hyperenhancement: (i) a 'normal' wavefront-ischaemic pattern, and (ii) multiple atypical mid-wall and epicardial areas of focal hyperenhancement. Invasive coronary angiography (ICA) and coronary computed tomographic angiography (CCTA) showed multiple intracoronary thrombi and distal emboli in the left anterior descending, ramus circumflexus, and in smaller branches of the LCA. All hyperenhancement patterns observed on DE-CMR perfectly matched the distribution territories of the affected coronary arteries. Discussion: This case with an acute myocardial infarction showed intracoronary thrombi and emboli on ICA and CCTA. Interestingly, DE-CMR showed two different patterns of hyperenhancement in the same territories of the coronary thrombi. This observation may challenge the concept that these non-endocardial areas of hyperenhancement on DE-CMR are always of non-ischaemic aetiology. It is hypothesized that occlusion of smaller distal branches of the coronary arteries may result in mid-wall or epicardial fibrosis as opposed to subendocardial fibrosis commonly found in patients with a large epicardial coronary occlusion. Clinicians should be aware of these atypical patterns to be able to initiate adequate medical therapy.