Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Transpl Infect Dis ; 26(3): e14271, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38605533

RESUMO

In this case, a 64-year-old male with a history of simultaneous orthotopic liver transplant and cadaveric renal transplant presented five years prior presented with persistent fevers two days after a positive SARS-CoV-2 nasal PCR. A CT scan of the chest on hospital day nine revealed innumerable 1-2 mm nodules in a miliary pattern throughout the lung. (1,3)-ß-D-glucan on hospital day 11 was 133 pg/mL. In this article, the approach, diagnostic and management strategies for patients with persistent fevers after diagnosis of COVID-19 in a transplant recipient are discussed.


Assuntos
COVID-19 , Febre , Transplante de Rim , Transplante de Fígado , SARS-CoV-2 , Humanos , Masculino , Transplante de Rim/efeitos adversos , Transplante de Fígado/efeitos adversos , COVID-19/diagnóstico , COVID-19/complicações , Pessoa de Meia-Idade , Febre/etiologia , Transplantados , Tomografia Computadorizada por Raios X , beta-Glucanas/sangue , Pulmão/diagnóstico por imagem , Pulmão/patologia , Pulmão/virologia
2.
Transpl Infect Dis ; 24(5): e13900, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35785460

RESUMO

BACKGROUND: Although infections are a significant potential complication among patients undergoing left ventricular assist device (LVAD) implantation, standardized surgical infection prophylaxis (SIP) regimens are not well defined. At Montefiore Medical Center, a 4-drug SIP regimen containing fluconazole, ciprofloxacin, rifampin, and vancomycin was previously utilized. In January 2020, the antimicrobial stewardship program implemented a 2-drug SIP regimen of vancomycin and cefazolin to limit exposure to broad-spectrum antibiotics. This study evaluated LVAD-associated infection rates prior to and following the SIP revision. METHODS: A retrospective review of patients who underwent LVAD implantation from 1/2018 to 4/2021 was performed. Infections were classified using the International Society for Heart and Lung Transplantation definitions. Infection rates at 2 weeks, 30 days, and 90 days post-implantation in the 4-drug SIP regimen (1/2018-12/2019) and the 2-drug SIP regimen (1/2020 to 4/2021) were compared. RESULTS: A total of 71 patients were included. The number of patients with LVAD-associated infections (including surgical site infections) was not significantly different in either SIP group at 2 weeks (9% vs. 4%, p = .64), 30 days (9% vs. 11%, p = .99), or 90 days (19% vs. 14%, p = .75). There was no statistically significant difference in 30 or 90-day mortality. LVAD-associated gram-negative (7% vs. 7%; p > .99) and fungal (5% vs. 0%; p = .51) infections were uncommon. The most common organism isolated was Staphylococcus aureus, and the most common type of infection was pneumonia in both SIP groups. CONCLUSION: No significant difference in LVAD-associated infections or infection-related mortality was observed with de-escalation of perioperative antibiotics. Additional studies with larger sample sizes are needed to endorse the findings of this study.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Antibacterianos/uso terapêutico , Antibioticoprofilaxia , Cefazolina , Ciprofloxacina , Fluconazol/uso terapêutico , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Rifampina , Resultado do Tratamento , Vancomicina/uso terapêutico
3.
Transpl Infect Dis ; 20(6): e12995, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30199584

RESUMO

INTRODUCTION: Left ventricular assist device (LVAD) infections are common, and the consequences of LVAD infections on orthotopic heart transplantation (OHT) outcomes are not well described. AIMS: The aim of this study was to describe clinical characteristics and evaluate risk factors for developing LVAD infections, and examine outcomes of LVAD-specific infections (VSI) after OHT. METHODS: We retrospectively investigated the records of 74 consecutive patients at two institutions who had undergone LVAD placement and subsequent OHT between January 2007 and December 2012. RESULTS: Forty-six of 74 (62%) LVAD recipients who underwent OHT had pre-transplant infections, and 18 (24%) had LVAD-specific infection (VSI), of which 71% were caused by gram-negative organisms. Of pre-transplant non-LVAD infections, Clostridium difficile infection (CDI) was the most common (26%) followed by urinary tract infection (UTI, 16%) and pneumonia (PNA 15%). Univariate analysis comparing subjects with VSI to those without VSI showed a significant association with time spent outside the hospital prior to transplantation (median 231.8 days vs 142.2 days, P < 0.03) and total time between VAD placement and OHT (244.0 days and 150.5 days, P < 0.002). Logistic regression was performed and significant predictors for VAD-related infection were age and the presence of diabetes, with type of device as an effect modifier. Six months post-OHT survival was not significantly affected by the presence of VSI prior to transplant. There was a trend toward an association between the presence of any infection and post-transplant rejection (P < 0.09). There were 10 post-transplant deaths by 6 months. Of these deaths, 4/10 (40%) were cardiopulmonary and 6/10 (60%) were related to infections. CONCLUSIONS: Advanced age and presence of diabetes were predictors of VSI, as well as type of VAD device, although device choice is likely affected by many clinical factors including age and comorbidities, as well as institution-specific preferences. VSI was not associated with a decrease in 6-month post-OHT survival. However, infections remain the major causes of death by 6 months post-transplant. Certain infections are associated with an increased risk of rejection, which merits further investigation.


Assuntos
Rejeição de Enxerto/epidemiologia , Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Coração Auxiliar/efeitos adversos , Infecções/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Adulto , Fatores Etários , Diabetes Mellitus/epidemiologia , Feminino , Humanos , Infecções/microbiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento
4.
P T ; 40(5): 353-60, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25987824

RESUMO

BACKGROUND: Patients with human immunodeficiency virus (HIV) infection on antiretroviral (ARV) therapy are at increased risk for medication errors during transitions of care between the outpatient and inpatient settings. This can lead to treatment failure or toxicity. Previous studies have emphasized the prevalence of medication errors in such patients, but few have reported initiatives to prevent errors from occurring. METHODS: The study was conducted in a 1,400-bed health care center with a state-designated Acquired Immunodeficiency Syndrome (AIDS) Center in the Bronx, New York. The antimicrobial stewardship team and HIV specialists developed customized order-entry sets (COES) to guide ARV prescribing and retrospectively reviewed their effect on error rates of initial ARV orders for inpatients before reconciliation. Patient records were reviewed in six-month periods before and after intervention. The student's t-test or Mann-Whitney U test was used to compare continuous variables; chi-square or Fisher's exact test was used for categorical variables. RESULTS: A total of 723 and 661 admissions were included in the pre-intervention and post-intervention periods, respectively. Overall, error rates decreased by 35% (38.0% to 24.8%, P < 0.01) with COES. Wrong doses and drug interactions decreased by more than 40% (P < 0.005). Error reductions were observed in protease inhibitor (PI)-based (43.6% versus 28.7%, P < 0.01) and non-PI-based (38.0% versus 24.4%, P = 0.02) regimens with COES. A shift in predominant drug-class errors was observed as there was a trend toward increased usage of non-PI regimens post-intervention. Admission in the pre-intervention period (adjusted odds ratio [AOR], 1.79; 95% confidence interval [CI], 1.39-2.31) and use of PI-based regimens (AOR, 2.03; 95% CI, 1.53-2.70) remained significantly associated with ARV prescribing errors after controlling for confounding factors. CONCLUSION: Detailed COES improved ARV prescribing habits, reduced the potential for prescribing incorrect regimens, and can prove useful and cost-effective where HIV-specific medication reconciliation is unavailable.

5.
ASAIO J ; 67(7): 746-751, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33196482

RESUMO

Our institution employs gallium-67 single-photon emission computed tomography low-dose CT (Ga-SPECT-CT) to determine the presence and extent of left ventricular assist device (LVAD) infections. We present a retrospective single-center study of 41 LVAD recipients who underwent Ga-SPECT-CT from January 2011 to June 2018 to determine whether Ga-SPECT-CT led to changes in antimicrobial therapy, LVAD revision or exchange, or application for 1A exception. The average age was 56.6 years, predominantly male (80.5%) and diabetic (68.3%), divided between ischemic (48.8%) and nonischemic (51.2%) cardiomyopathy. The majority had HeartMate II devices (82.9%). Device-related infections were classified as possible (12.2%), probable (36.6%), proven (36.6%), or rejected (14.6%). Sensitivity was 68.6% and specificity was 100%. Most VAD-specific infections were percutaneous deep driveline infections (DRIs) (34.1%), and VAD-related infections were primarily bloodstream infections (31.7%). Staphylococcus aureus was the major pathogen isolated. Gallium-67 single-photon emission computed tomography low-dose CT resulted in changes in management in more than half (53.7%) of patients: starting (24.4%) or stopping (17.1%) antimicrobial therapy, LVAD revision (22.0%) or exchange (12.2%), and the application for 1A exception for transplant listing (17.1%). We conclude that Ga-SPECT-CT is an effective modality for determining the presence and extent of LVAD DRIs, and contributed to a change in management in more than half of cases.


Assuntos
Coração Auxiliar , Feminino , Radioisótopos de Gálio , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/etiologia , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único
6.
J Thorac Dis ; 9(1): 205-210, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28203425

RESUMO

Left ventricular assist devices (LVADs) have been successfully used in patients with heart failure. However, LVADs may trigger immune activation, leading to higher frequencies of autoantibodies. We describe the clinical, epidemiological, and laboratory characteristics of LVAD recipients with false positive hepatitis C (FPHC) serology among 39 consecutive adult LVAD recipients who bridged to heart transplantation from January 2007 to January 2013 at Montefiore Medical Center. FPHC patients were identified as those with post-LVAD positive hepatitis C ELISA antibody tests and negative confirmatory testing with hepatitis C RNA PCR and/or radioimmunoblot assay. Ten (26%) patients previously seronegative for hepatitis C were found to have FPHC after device placement. Of the 39 patients, 32 had HeartMate II devices. The mean age at LVAD placement was 55 years. FPHC correlated with older age at the time of LVAD implantation and with receipt of packed red blood cell transfusions, but not with gender, fresh frozen plasma transfusions, panel reactive antibodies, globulin fraction, rheumatoid factor, or anticardiolipin antibodies. Clinicians should be aware of this increased risk of FPHC in older LVAD patients and those more heavily transfused in order to avoid unnecessary apprehension and possible delay in transplantation. Further studies should be done to evaluate the possible relationship between transfused blood products and immunomodulation.

7.
ASAIO J ; 61(1): e5-10, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25419830

RESUMO

Infection remains a well-established complication after the placement of left ventricular assist devices (LVADs). Defining the extent of infection is a challenging task as there are few effective imaging modalities and no standardized guidelines regarding imaging in the diagnosis of device-related infections (DRIs). The use of gallium with single photon emission tomography-computed tomography (Ga-SPECT-CT) has not been previously reported in localizing DRIs. We reviewed the charts and images of five patients with LVADs who underwent Ga-SPECT-CT for the diagnosis of various types of DRIs. Gallium SPECT-CT further clarified the extent of infections among LVAD patients, allowing for patient-specific tailored treatments including surgical debridement. Gallium SPECT-CT is a useful tool when diagnosing LVAD infections and could potentially be the imaging modality of choice in the near future. With improved imaging studies, such as Ga-SPECT-CT, allowing for earlier and more accurate diagnoses of DRIs, the outcome of such infections is likely to improve.


Assuntos
Coração Auxiliar/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/etiologia , Adulto , Idoso , Bacteriemia/diagnóstico por imagem , Bacteriemia/etiologia , Radioisótopos de Gálio , Humanos , Masculino , Staphylococcus aureus Resistente à Meticilina , Pessoa de Meia-Idade , Infecções Estafilocócicas/diagnóstico por imagem , Infecções Estafilocócicas/etiologia , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA