Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(20)2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37896473

RESUMO

The necessity of early warning systems to ensure people's safety requires the usage of real-time monitoring instrumentation. To meet the required real-time monitoring performance, in-place inclinometer systems represent one of the most common solutions to obtain accurate measures over time. This paper presents the results of a laboratory tests campaign performed on the prototypes and preproduction samples of an in-place inclinometer chain for structural and geotechnical monitoring applications. First, each element sensor has been calibrated to reach a proper level of measure accuracy. Eventually, laboratory tests are carried out on both a single instrument (element) and on the complete measurement chain (system). The adopted centering device, obtained as a combination of a Cardan joint and four spring plungers avoids bending of elements by preventing fictitious displacement measurements and permits the creation of a kinematic chain that accommodates the displacements of a grooveless tube. A specially designed and constructed test set-up that permits assigning a movement to each node has been employed to test a specifically designed centering device and check the system stability over time. Different scenarios have been investigated to determine the accuracy and repeatability of the measures in replicating real cases. The results demonstrated the necessity of validating a measurement chain by analyzing its overall behavior and not limiting the study on the performances of a single element.

2.
Materials (Basel) ; 13(14)2020 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-32698358

RESUMO

The complex failure mechanisms of glass laminates under in-plane loading conditions is modelled within the framework of phase-field strategy. Laminated glass is widely used for structural purposes due to its safe post-glass-breakage response. In fact, the combination of several glass plies bonded together with polymeric interlayers allows overcoming the brittleness of the glass and to reach a pseudo-ductile response. Moreover, the post-breakage behaviour of the laminate is strictly correlated by the mechanical properties of the constituents. Ruptures may appear as cracks within the layers or delamination of the bonding interface. The global response of a glass laminate, validated against experimental results taken from the literature, is carried out by investigating a simplified layup of two glass plies connected by cohesive interfaces through an interlayer. Delamination of the adhesive interface is described, and crack patterns within the materials are fully described. Finally, the proposed approach put the basis for future comparisons with results of experimental campaign and real-life applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA