Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
J Cardiovasc Electrophysiol ; 34(1): 90-98, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36217994

RESUMO

INTRODUCTION: Phrenic nerve (PN) injury is a rare but severe complication of radiofrequency (RF) pulmonary vein isolation (PVI). The objective of this study was to characterize the typical intracardiac course of the PN with a three-dimensional electroanatomic mapping system, to quantify the need for modification of the ablation trajectory to avoid delivering an ablation lesion on sites with PN capture, and to identify very circumscribed areas of common PNC on the routine ablation trajectory of a RF-PVI, allowing fast and effective PN screening for everyday usage. METHODS: We enrolled 137 consecutive patients (63 ± 9 years, 64% men) undergoing PVI. A detailed high output (20 mA) pace-mapping protocol was performed in the right (RA) and left atrium (LA) and adjacent vasculature. RESULTS: The right PN was most commonly captured in the superior vena cava at a lateral (50%) or posterolateral (23%) position before descending along the RA either straight (29%) or with a posterolateral bend (20%). In the LA, beginning deep within the right superior pulmonary vein (RSPV), the right PN is most frequently detectable anterolateral (31%), then descends to the lateral proximal RSPV (23%), and further towards the lateral antral region (15%) onto the medial LA wall (12%). To avoid delivering an ablation lesion on sites with PN capture, modification of ablation trajectory was necessary in 23% of cases, most commonly in the lateral RSPV antrum (81%). No PN injury occurred. CONCLUSION: PN mapping frequently reveals the close proximity of the PN to the ablation trajectory during PVI, particularly in the lateral RSPV antrum. Routine PN pacing should be considered during RF PVI procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Traumatismos dos Nervos Periféricos , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Nervo Frênico/lesões , Veias Pulmonares/cirurgia , Veia Cava Superior/cirurgia , Átrios do Coração/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Traumatismos dos Nervos Periféricos/diagnóstico , Traumatismos dos Nervos Periféricos/etiologia , Traumatismos dos Nervos Periféricos/prevenção & controle
2.
Europace ; 25(1): 65-73, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35852306

RESUMO

AIMS: The cornerstone of pulmonary vein (PV) isolation (PVI) is a wide-area circumferential ablation (WACA) resulting in an antral PVI area. Pulsed-field ablation (PFA) is a new nonthermal 'single-shot' PVI technique resulting in well-characterized posterior isolation areas. However, information on circumferential PVI area is lacking. Thus, we sought to characterize the circumferential antral PVI areas after PFA-PVI. METHODS AND RESULTS: Atrial fibrillation (AF) patients underwent fluoroscopy-guided PVI with a pentaspline PFA catheter. Ultra-high-density voltage maps using a 20-polar circular mapping catheter were created before and immediately after PVI to identify and quantify (i) insufficient isolation areas per antral PV segment (10-segment model) and (ii) enlarged left atrial (LA) isolation areas (beyond the antral PV segments) per LA region (8-region model). The PFA-PVI with pre- (5469 ± 1822 points) and post-mapping (6809 ± 2769 points) was performed in 40 consecutive patients [age 62 ± 6 years, 25/40 (62.5%) paroxysmal AF]. Insufficient isolation areas were located most frequently in the anterior antral PV segments of the left PVs (62.5-77.5% of patients) with the largest extent (median ≥0.4 cm2) located in the same segments (segments 2/5/8). Enlarged LA isolation areas were located most frequently and most extensively on the posterior wall and roof region (89.5-100% of patients; median 1.1-2.7 cm2 per region). CONCLUSION: Fluoroscopy-guided PFA-PVI frequently results in insufficient isolation areas in the left anterior antral PV segments and enlarged LA isolation areas on the posterior wall/roof, which both may be extensive. To optimize the procedure, full integration of PFA catheter visualization into three-dimensional-mapping systems is needed.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Pessoa de Meia-Idade , Idoso , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Catéteres , Resultado do Tratamento
3.
Europace ; 25(3): 1126-1134, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36610064

RESUMO

AIMS: Transseptal puncture (TP) for left-sided catheter ablation procedures is routinely performed under fluoroscopic or echocardiographic guidance [transoesophageal echocardiography (TEE) or intracardiac echocardiography (ICE)], although three-dimensional (3D) mapping systems are readily available in most electrophysiology laboratories. Here, we sought to assess the feasibility and safety of a right atrial (RA) 3D map-guided TP. METHODS AND RESULTS: In 104 patients, 3D RA mapping was performed to identify the fossa ovalis (FO) using the protrusion technique. The radiofrequency transseptal needle was visualized and navigated to the desired potential FO-TP site. Thereafter, the interventionalist was unblinded to TEE and the potential FO-TP site was reassessed regarding its convenience and safety. After TP, the exact TP site was documented using a 17-segment-FO model. Reliable identification of the FO was feasible in 102 patients (98%). In these, 114 3D map-guided TP attempts were performed, of which 96 (84%) patients demonstrated a good position and 18 (16%) an adequate position after TEE unblinding. An out-of-FO or dangerous position did not occur. A successful 3D map-guided TP was performed in 110 attempts (97%). Four attempts (3%) with adequate positions were aborted in order to seek a more convenient TP site. The median time from RA mapping until the end of the TP process was 13 (12-17) min. No TP-related complications occurred. Ninety-eight TP sites (85.1%) were in the central portion or in the inner loop of the FO. CONCLUSION: A 3D map-guided TP is feasible and safe. It may assist to decrease radiation exposure and the need for TEE/ICE during left-sided catheter ablation procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Estudos de Viabilidade , Cateterismo Cardíaco/métodos , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Punções , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Resultado do Tratamento
4.
Medicina (Kaunas) ; 59(11)2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-38004016

RESUMO

Background and Objectives: Patients with chronic total occlusions of the coronary arteries are either treated with PCI or referred for surgical revascularization. We analyzed the patients with chronic occluded coronary arteries that were surgically treated and aimed to describe the anatomical characteristics, revascularization rates, and in-hospital outcomes achieved with coronary artery bypass grafting. Methods: Angiographic data of 2005 patients with coronary artery disease treated in our institution between January 2005 and December 2014 were retrospectively analyzed. A total of 1111 patients with at least one coronary total occlusion were identified. We reviewed the preoperative coronary angiograms and surgical protocols to determine the presence, localization, and revascularization of coronary occlusions. We also evaluated the perioperative data and in-hospital outcomes. Results: The median age of the study population was 68 years (25th-75th percentiles, 61.0-74.0). Three-vessel disease was present in 94.8% of patients and the rest (5.8%) had a two-vessel disease. The localizations of the occlusions were as follows: 68.4% in the RCA system, 26.4% in the LAD, and 28.5% in the LCX system. Multiple occlusions were present in 22.6% of the patients. Complete coronary total occlusion revascularization was achieved in 86.1% of the patients. The overall in-hospital mortality was 2.3%. The median in-hospital stay was 14.0 days. After logistic regression analysis, age (odds ratio 3.44 [95% confidence interval, 1.81-6.53], p < 0.001, for a 10-year increase) and the presence of peripheral artery disease (odds ratio 3.32 [1.39-7.93], p = 0.007) were the only statistically significant independent predictors of in-hospital mortality. Conclusions: A high revascularization rate and favorable in-hospital outcomes are achieved with coronary artery bypass surgery in patients with multi-vessel diseases and coronary total occlusions. Older age and the presence of peripheral artery disease are independent predictors of in-hospital mortality. A long-term follow-up and the type of graft (arterial vs. venous) used would bring more useful data for this type of revascularization.


Assuntos
Doença da Artéria Coronariana , Oclusão Coronária , Intervenção Coronária Percutânea , Doença Arterial Periférica , Humanos , Idoso , Oclusão Coronária/cirurgia , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Resultado do Tratamento , Doença da Artéria Coronariana/cirurgia , Hospitais , Doença Arterial Periférica/etiologia , Fatores de Risco
5.
Europace ; 24(7): 1102-1111, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35298612

RESUMO

AIMS: Atrial cardiomyopathy (ACM) is associated with increased arrhythmia recurrence rates after pulmonary vein isolation (PVI). We compare the most common left atrial (LA) late gadolinium enhancement magnetic resonance imaging (LGE-MRI)-methods [Utah-method and image intensity ratio (IIR)-methods] and endocardial voltage mapping for ACM-detection and outcome prediction after PVI for atrial fibrillation (AF). METHODS AND RESULTS: In this prospective observational study, 37 ablation-naive patients (66 ± 9 years, 84% male) with persistent AF underwent LA-LGE-MRI and high-definition voltage and activation mapping (2129 ± 484 sites) in sinus rhythm prior to PVI. The MRI-post-processing-analyses were performed by two independent expert laboratories. Arrhythmia recurrence was recorded within 12 months following PVI. The global ACM-extent was highly variable: median LA low-voltage substrate (LA-LVS) was 12.9% at <1.0 mV and 2.7% at <0.5 mV; median LA-LGE-extent using the Utah-method was 18.3% and 0.03-93.1% using the IIR-methods. The LA activation time was significantly correlated with LA-LVS (r = 0.76 at <0.5 mV and r = 0.82 at <1.0 mV, both P < 0.0001), but not with LA-LGE-extent. The highest regional matching between LA-LVS <0.5 mV and LA-LGE was found for the anterior wall in 57% of patients using the Utah-method and in 59% using IIR 1.20. The corresponding values for the posterior wall were 19% and 38%, respectively. Arrhythmia recurrence occurred in 15(41%) patients. Freedom from arrhythmia was significantly lower in those with LA-LVS ≥2 cm2 at 0.5 mV but not in those with LGE ≥20% (Utah-stages III and IV): 43% vs. 81%, P = 0.009 and 50% vs. 67%, P = 0.338, respectively. CONCLUSION: Comparison of the most common LA-LGE-MRI methods and endocardial voltage mapping revealed large discrepancies in global and regional ACM-extent.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Meios de Contraste , Feminino , Gadolínio , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino
6.
Europace ; 23(12): 2010-2019, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34463710

RESUMO

AIMS: Atrial cardiomyopathy (ACM) is associated with new-onset atrial fibrillation, arrhythmia recurrence after pulmonary vein isolation (PVI) and increased risk for stroke. At present, diagnosis of ACM is feasible by endocardial contact mapping of left atrial (LA) low-voltage substrate (LVS) or late gadolinium-enhanced magnetic resonance imaging, but their complexity limits a widespread use. The aim of this study was to assess non-invasive body surface electrocardiographic imaging (ECGI) as a novel clinical tool for diagnosis of ACM compared with endocardial mapping. METHODS AND RESULTS: Thirty-nine consecutive patients (66 ± 9 years, 85% male) presenting for their first PVI for persistent atrial fibrillation underwent ECGI in sinus rhythm using a 252-electrode-array mapping system. Subsequently, high-density LA voltage and biatrial activation maps (mean 2090 ± 488 sites) were acquired in sinus rhythm prior to PVI. Freedom from arrhythmia recurrence was assessed within 12 months follow-up. Increased duration of total atrial conduction time (TACT) in ECGI was associated with both increased atrial activation time and extent of LA-LVS in endocardial contact mapping (r = 0.77 and r = 0.66, P < 0.0001 respectively). Atrial cardiomyopathy was found in 23 (59%) patients. A TACT value of 148 ms identified ACM with 91.3% sensitivity and 93.7% specificity. Arrhythmia recurrence occurred in 15 (38%) patients during a follow-up of 389 ± 55 days. Freedom from arrhythmia was significantly higher in patients with a TACT <148 ms compared with patients with a TACT ≥148 ms (82.4% vs. 45.5%, P = 0.019). CONCLUSION: Analysis of TACT in non-invasive ECGI allows diagnosis of patients with ACM, which is associated with a significantly increased risk for arrhythmia recurrence following PVI.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
7.
Pacing Clin Electrophysiol ; 44(2): 240-246, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33372688

RESUMO

OBJECTIVES: We sought to assess the safety of a restrictive permanent pacemaker implantation (PPI) strategy after transcatheter aortic valve implantation (TAVI) as compared to a liberal strategy. BACKGROUND: Conduction disturbances resulting in PPI are common after TAVI. However, conduction disturbances may be transient and PPI may be superfluous in some patients. METHODS: Until August 2015, we performed PPI in all patients with new complete left bundle branch block (LBBB, QRS > 120 milliseconds) or higher degree atrioventricular (AV) blocks (liberal strategy). From September 2015 onwards, LBBB established an indication for PPI only in the presence of new-onset AV block (PQ > 200 milliseconds) (restrictive strategy). We analyzed the impact of the restrictive strategy on pacemaker implantation rate, duration of hospital stay, and 1-year mortality. RESULTS: Between January 2014 and December 2016, 383 consecutive, pacemaker-naive patients underwent TAVI with the liberal PPI strategy and subsequently 384 with the restrictive strategy. The restrictive strategy significantly reduced the percentage of patients undergoing PPI before discharge (17.2% vs. 38.1%, p < .001) and length of hospital stay (intensive care unit 52 ± 55 vs. 60 ± 52 hours, p < .001; general ward 10.6 ± 5.7 vs. 11.5 ± 5.7 days, p = .001). One-year all-cause mortality was not significantly different between groups (14.1% vs. 11.7%, log-rank p = .28). However, sudden death was more frequent in the restrictive group (3.4% vs. 1.3%, log-rank p = .049). CONCLUSIONS: As compared to a liberal indication for PPI, a restrictive indication reduced PPI rate and length of hospital stay without significantly affecting all-cause mortality. The observed increase in the risk of sudden death with the restrictive PPI indication deserves further investigation.


Assuntos
Bloqueio de Ramo/mortalidade , Bloqueio de Ramo/terapia , Marca-Passo Artificial , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Implantação de Prótese/métodos , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Retrospectivos
8.
Europace ; 22(5): 732-738, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32142124

RESUMO

AIMS: Transseptal puncture (TP) for left atrial (LA) catheter ablation procedures is routinely performed under fluoroscopic guidance. To decrease radiation exposure and increase safety alternative techniques are desirable. The aim of this study was to assess whether right atrial (RA) electroanatomic 3D mapping can reliably identify the fossa ovalis (FO) in preparation of TP. METHODS AND RESULTS: Between May 2019 and August 2019, electroanatomic RA mapping was performed before TP in 61 patients with paroxysmal or persistent atrial fibrillation. Three electroanatomic methods for FO identification, mapping catheter-induced FO protrusion, electroanatomic-guided analysis, and voltage mapping, were evaluated and compared with transoesophageal echocardiography (TOE). Mapping catheter-induced FO protrusion was feasible in 60 patients (98%) with a mean displacement of 6.8 ± 2.5 mm, confirmed by TOE, and proofed to be the most valuable and easiest marker for FO identification. Electroanatomic-guided analysis localized the FO midpoint consistently in the lower half (43 ± 7%) and posterior (18.2 ± 4.4 mm) to a line between coronary sinus and vena cava superior. Analysis of RA voltage maps during sinus rhythm (n = 40, low-voltage cut-off value 1.0 and 1.5 mV) allowed secure FO recognition in 33% and 18%, only. A step-by-step approach, combining FO protrusion (first step) with anatomy criteria in case of protrusion failure (second step) would have allowed for the correct localization of a TP site within the FO in all patients. CONCLUSION: Right atrial electroanatomic 3D mapping prior to TP proofed to be a simple tool for FO identification and may potentially be of use in the safe and radiation-free performance of TP prior to LA ablation procedures.


Assuntos
Fibrilação Atrial , Septo Interatrial , Ablação por Cateter , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Septo Interatrial/diagnóstico por imagem , Septo Interatrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Projetos Piloto , Punções , Resultado do Tratamento
9.
Europace ; 21(6): 871-878, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-31157388

RESUMO

AIMS: Sinus rhythm restoration (SRR) in patients with atrial fibrillation (AF) and heart failure may improve systolic function and impact on consecutive clinical management, but time course and potential predictors of response to SRR are uncertain. METHODS AND RESULTS: We prospectively studied 50 consecutive patients who presented in heart failure with reduced ejection fraction (EF) and concomitant AF. After exclusion of valvular and coronary artery disease patients underwent electrical cardioversion. Serial echocardiography, cardiac magnetic resonance imaging (cMRI), and 24-h electrocardiograms were performed at baseline, and on Days 3 and 40 following SRR. Baseline left ventricular EF of the study population (76% male, age 69 ± 11 years) was 30 ± 7%. Sustained SRR (≥3 days) significantly improved EF (Day 3: 43 ± 7%, n = 46; Day 40: 53 ± 9%, n = 34; P < 0.001) as quantified by echocardiography. Comparable results were obtained using cMRI (baseline: 29 ± 8%; Day 3: 42 ± 9%). Three patients showed no response to SRR (EF improvement <15%). The percentage of patients meeting current criteria for implantable cardioverter-defibrillator (ICD) implantation for primary prevention dropped from 76% (n = 38) to 11% (n = 3) on Day 40 following SRR. No specific clinical or echocardiographic factor predicting improved EF after SRR could be identified. CONCLUSION: The majority of patients presenting with non-ischaemic, non-valvular heart failure with reduced EF and concomitant AF show a significant and rapid improvement in EF following SRR. An attempt at SRR and reassessment of the need for ICD implantation after 40 days may be warranted in all such patients.


Assuntos
Fibrilação Atrial/terapia , Cardiomiopatias/terapia , Cardioversão Elétrica , Disfunção Ventricular Esquerda/terapia , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico por imagem , Eletrocardiografia , Feminino , Humanos , Masculino , Estudos Prospectivos , Volume Sistólico , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico por imagem
10.
Europace ; 21(10): 1484-1493, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31280323

RESUMO

AIMS: Atrial fibrosis contributes to arrhythmogenesis in atrial fibrillation and can be detected by MRI or electrophysiological mapping. The current study compares the spatial correlation between delayed enhancement (DE) areas to low-voltage areas (LVAs) and to arrhythmogenic areas with spatio-temporal dispersion (ST-Disp) or continuous activity (CA) in atrial fibrillation (AF). METHODS AND RESULTS: Sixteen patients with persistent AF (nine long-standing) underwent DE-magnetic resonance imaging (1.25 mm × 1.25 mm × 2.5 mm) prior to pulmonary vein isolation. Left atrial (LA) voltage mapping was acquired in AF and the regional activation patterns of 7680 AF wavelets were analysed. Sites with ST-Disp or CA were characterized (voltage, duration) and their spatial relationship to DE areas and LVAs <0.5 mV was assessed. Delayed enhancement areas and LVAs covered 55% and 24% (P < 0.01) of total LA surface, respectively. Delayed enhancement area was present at 61% of LVAs, whereas low voltage was present at 28% of DE areas. Most DE areas (72%) overlapped with atrial high-voltage areas (>0.5 mV). Spatio-temporal dispersion and CA more frequently co-localized with LVAs than with DE areas (78% vs. 63%, P = 0.02). Regional bipolar voltage of ST-Disp vs. CA was 0.64 ± 0.47 mV vs. 0.58 ± 0.51 mV. All 28 ST-Disp and 56 CA areas contained electrograms with prolonged duration (115 ± 14 ms) displaying low voltage (0.34 ± 0.11 mV). CONCLUSION: A small portion of DE areas and LVAs harbour the arrhythmogenic areas displaying ST-Disp or CA. Most arrhythmogenic activities co-localized with LVAs, while there was less co-localization with DE areas. There is an important mismatch between DE areas and LVAs which needs to be considered when used as target for catheter ablation.


Assuntos
Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo/fisiologia , Átrios do Coração/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Meglumina/farmacologia , Miocárdio/patologia , Compostos Organometálicos/farmacologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Meios de Contraste/farmacologia , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Fibrose/patologia , Gadolínio , Átrios do Coração/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
11.
Europace ; 20(2): 279-287, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28011800

RESUMO

Aims: The number of pulmonary vein isolation (PVI) ablation procedures is steadily increasing worldwide resulting in a substantial radiation exposure to patients and operators. The aim of our study was to reduce radiation exposure during these procedures to a critical amount without compromising patient safety. Methods and results: First, we assessed radiation exposure for primary PVI procedures over time (2005-2015) at the University Heart Center Freiburg-Bad Krozingen. Second, we prospectively evaluated in 52 patients, the efficacy and safety of a novel radiation reduction program (particularly applying an enhanced fluoroscopy pulse dose-reduction and optimized 3D-mapping system use). In 2035 primary PVI procedures, radiation exposure, assessed as estimated effective dose (eED in mSv, dose area product * 0.002 * conversion factor for females), fluoroscopy-time, and procedure-time decreased significantly from 2005 to 2015 (e.g. eED decreased from 9.3 (interquartile range (IQR) 6.4-13.4) mSv to 0.9 (IQR 0.5-1.6) mSv, p for trend <0.001). Importantly, application of the enhanced radiation reduction program further reduced eED to 0.4 mSv (IQR 0.3-0.6, P < 0.001 vs. control), a value not significantly different from slow-pathway ablation procedures (P = 0.41). Multiple linear regression analysis identified the radiation reduction program as the only independent variable associated with a decrease in radiation exposure. Conclusion: Radiation exposure during PVI decreased over the last decade and can further be reduced significantly by the implementation of an enhanced radiation reduction program.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Programas e Projetos de Saúde , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
12.
Echocardiography ; 35(6): 777-784, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29522643

RESUMO

AIM: Two-dimensional, transthoracic echocardiography does not account for the noncircular anatomy of the left ventricular outflow tract (LVOT) and may therefore underestimate LVOT area. Fusion of computed tomography (CT)-derived LVOT area and Doppler-derived flow data has been proposed to improve assessment of aortic valve area (AVA) and classification of aortic stenosis severity. For hemodynamic reasons, effective AVA has to be smaller than anatomic AVA. The aim of the study was to test the "fusion approach" by comparing effective CT-derived AVA with anatomic AVA from CT planimetry. METHODS AND RESULTS: Data of 244 consecutive patients (mean age 81 ± 5 years, 61% female) with aortic stenosis were retrospectively analyzed comparing effective AVA (calculated from the continuity equation using CT-LVOT and transthoracic Doppler measurements) with anatomic AVA based on CT planimetry. Substituting the LVOT area from transthoracic echocardiography (TTE) by the CT-LVOT resulted in an increase in AVA from 0.74 ± 0.15 to 0.92 ± 0.18cm² (P < .01), which was larger than anatomic AVA (0.82 ± 0.15cm²). Similar results were obtained based on planimetry from transesophageal echocardiography (TEE; AVA 0.79 ± 0.14cm², P < .01 vs CT-LVOT) and in the subgroup presenting with low-gradient severe aortic stenosis and preserved ejection fraction (n = 67, AVA from TTE 0.76 ± 0.09; from CT-LVOT 0.97 ± 0.14; CT planimetry 0.86 ± 0.12; TEE planimetry 0.82 ± 0.13cm²). CONCLUSION: Fusion of CT-derived LVOT area with Doppler echocardiography results in a calculated effective AVA that is larger than the corresponding anatomic AVA. Therefore, adjustment of partition values may be warranted when using this approach.


Assuntos
Valva Aórtica/diagnóstico por imagem , Ecocardiografia Doppler/métodos , Ecocardiografia Tridimensional , Ventrículos do Coração/diagnóstico por imagem , Hemodinâmica/fisiologia , Tomografia Computadorizada por Raios X/métodos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/fisiopatologia , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
13.
Eur Heart J ; 35(6): 365-75, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23821402

RESUMO

AIMS: Several high-sensitivity cardiac troponin (hs-cTn) assays have recently been developed. It is unknown which hs-cTn provides the most accurate prognostic information and to what extent early changes in hs-cTn predict mortality. METHODS AND RESULTS: In a prospective, international multicentre study, cTn was simultaneously measured with three novel [high-sensitivity cardiac Troponin T (hs-cTnT), Roche Diagnostics; hs-cTnI, Beckman-Coulter; hs-cTnI, Siemens] and a conventional assay (cTnT, Roche Diagnostics) in a blinded fashion in 1117 unselected patients with acute chest pain. Patients were followed up 2 years regarding mortality. Eighty-two (7.3%) patients died during the follow-up. The 2-year prognostic accuracy of hs-cTn was most accurate for hs-cTnT [area under the receivers operating characteristic curve (AUC) 0.78 (95% CI: 0.73-0.83) and outperformed both hs-cTnI (Beckman-Coulter, 0.71 (95% CI: 0.65-0.77; P = 0.001 for comparison), hs-cTnI (Siemens) 0.70 (95% CI: 0.64-0.76; P < 0.001 for comparison)] and cTnT 0.67 (95% CI: 0.61-0.74; P < 0.001 for comparison). Absolute changes of hs-cTnT were more accurate than relative changes in predicting mortality, but inferior to presentation values of hs-cTnT. Combining changes of hs-cTnT within the first 6 h with their presentation values did not further improve prognostic accuracy. Similar results were obtained for both hs-cTnI assays regarding the incremental value of changes. Hs-cTn concentrations remained predictors of death in clinically challenging subgroups such as patients with pre-existing coronary artery disease, impaired renal function, and patients older than 75 years. CONCLUSION: High-sensitivity cardiac Troponin T is more accurate than hs-cTnI in the prediction of long-term mortality. Changes of hs-cTn do not seem to further improve risk stratification beyond initial presentation values.


Assuntos
Angina Instável/diagnóstico , Dor no Peito/etiologia , Infarto do Miocárdio/diagnóstico , Troponina T/sangue , Idoso , Angina Instável/mortalidade , Área Sob a Curva , Biomarcadores/sangue , Dor no Peito/mortalidade , Creatina Quinase Forma MB/sangue , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Mioglobina/sangue , Prognóstico , Estudos Prospectivos , Medição de Risco/métodos , Sensibilidade e Especificidade
14.
J Cardiovasc Electrophysiol ; 25(3): 266-70, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24172190

RESUMO

BACKGROUND: Thrombi form mainly in the left rather than the right atria of patients with atrial fibrillation (AF), the reason of this predilection being unknown. OBJECTIVE: The purpose of this study was to investigate whether atrial-specific differences in endothelial damage, leukocyte activation, platelet stimulation, and tissue factor activity occur in patients with AF. METHODS: Twenty-two patients (16 men, 6 women; age 56 ± 8 years; 16 paroxysmal AF, 6 persistent AF) with AF undergoing pulmonary vein isolation were investigated. Blood samples from the left and the right atrium were obtained at the start of the procedure. Microparticles (MPs) released by apoptotic/stimulated cells were measured by capture assays. Their procoagulant abilities were quantified by functional prothrombinase and tissue factor assays and their cellular origin were determined (endothelium, platelet, leukocyte). Platelet reactivity was evaluated by whole blood flow cytometry for expression of platelet P-selectin (CD62P), active glycoprotein IIb/IIIa receptor (PAC-1). Platelet aggregation was evaluated using ADP, TRAP and collagen-induced whole blood aggregometry. RESULTS: There were no atrial-specific differences in the levels of total procoagulant MPs, leukocyte-derived-MPs or platelet-derived MPs. Conversely, endothelial-derived MPs and tissue factor activity and collagen-induced platelet aggregation were slightly elevated in the right atrium (P < 0.05). CONCLUSIONS: Our data show no evidence for increased thrombogenic status in the left atrium that would account for its greater propensity for thrombus formation in patients with AF.


Assuntos
Fibrilação Atrial/diagnóstico , Endotélio Vascular/patologia , Átrios do Coração/patologia , Ativação Plaquetária/fisiologia , Trombose/diagnóstico , Fibrilação Atrial/sangue , Micropartículas Derivadas de Células/metabolismo , Micropartículas Derivadas de Células/patologia , Endotélio Vascular/metabolismo , Feminino , Átrios do Coração/metabolismo , Humanos , Leucócitos/metabolismo , Leucócitos/patologia , Masculino , Pessoa de Meia-Idade , Tromboplastina/metabolismo , Trombose/sangue
15.
J Clin Med ; 13(8)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38673658

RESUMO

Background: The goal of our study is to evaluate a method to quantify aortic valve calcification (AVC) in contrast-enhanced computed tomography for patients with suspected severe aortic stenosis pre-interventionally. Methods: A total of sixty-five patients with aortic stenosis underwent both a native and a contrast-enhanced computed tomography (CECT) scan of the aortic valve (45 in the training cohort and 20 in the validation cohort) using a standardized protocol. Aortic valve calcification was semi-automatically quantified via the Agatston score method for the native scans and was used as a reference. For contrast-enhanced computed tomography, a calcium threshold of the Hounsfield units of the aorta plus four times the standard deviation was used. Results: For the quantification of aortic valve calcification in contrast-enhanced computed tomography, a conversion formula (691 + 1.83 x AVCCECT) was derived via a linear regression model in the training cohort. The validation in the second cohort showed high agreement for this conversion formula with no significant proportional bias (Bland-Altman, p = 0.055) and with an intraclass correlation coefficient in the validation cohort of 0.915 (confidence interval 95% 0.786-0.966) p < 0.001. Conclusions: Calcium scoring in patients with aortic valve stenosis can be performed using contrast-enhanced computed tomography with high validity. Using a conversion factor led to an excellent agreement, thereby obviating an additional native computed tomography scan. This might contribute to a decrease in radiation exposure.

16.
Circulation ; 123(8): 887-95, 2011 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-21321152

RESUMO

BACKGROUND: Retrospective studies have suggested that patients with a low transvalvular gradient in the presence of an aortic valve area < 1.0 cm² and normal ejection fraction may represent a subgroup with an advanced stage of aortic valve disease, reduced stroke volume, and poor prognosis requiring early surgery. We therefore evaluated the outcome of patients with low-gradient "severe" stenosis (defined as aortic valve area < 1.0 cm² and mean gradient ≤ 40 mm Hg) in the prospective Simvastatin and Ezetimibe in Aortic Stenosis (SEAS) study. METHODS AND RESULTS: Outcome in patients with low-gradient "severe" aortic stenosis was compared with outcome in patients with moderate stenosis (aortic valve area 1.0 to 1.5 cm²; mean gradient 25 to 40 mm Hg). The primary end point of aortic valve events included death from cardiovascular causes, aortic valve replacement, and heart failure due to aortic stenosis. Secondary end points were major cardiovascular events and cardiovascular death. In 1525 asymptomatic patients (mean age, 67 ± 10 years; ejection fraction, ≥ 55%), baseline echocardiography revealed low-gradient severe stenosis in 435 patients (29%) and moderate stenosis in 184 (12%). Left ventricular mass was lower in patients with low-gradient severe stenosis than in those with moderate stenosis (182 ± 64 versus 212 ± 68 g; P < 0.01). During 46 months of follow-up, aortic valve events occurred in 48.5% versus 44.6%, respectively (P = 0.37; major cardiovascular events, 50.9% versus 48.5%, P = 0.58; cardiovascular death, 7.8% versus 4.9%, P = 0.19). Low-gradient severe stenosis patients with reduced stroke volume index (≤ 35 mL/m²; n = 223) had aortic valve events comparable to those in patients with normal stroke volume index (46.2% versus 50.9%; P = 0.53). CONCLUSIONS: Patients with low-gradient "severe" aortic stenosis and normal ejection fraction have an outcome similar to that in patients with moderate stenosis.


Assuntos
Estenose da Valva Aórtica/tratamento farmacológico , Estenose da Valva Aórtica/fisiopatologia , Azetidinas/uso terapêutico , Índice de Gravidade de Doença , Sinvastatina/uso terapêutico , Volume Sistólico/fisiologia , Idoso , Anticolesterolemiantes/uso terapêutico , Estenose da Valva Aórtica/mortalidade , Progressão da Doença , Eletrocardiografia , Ezetimiba , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
17.
J Clin Med ; 11(8)2022 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-35456350

RESUMO

BACKGROUND: The impact of transcatheter heart valve (THV) position on the occurrence of paravalvular leakage and permanent pacemaker implantation caused by new-onset conduction disturbances is well described. The purpose of this study was to investigate the influence of the geometry of the thoracic aorta on the implantation depth after TAVI (transcatheter heart valve implantation) using self-expanding valve (SEV) types. METHODS: We evaluated three-dimensional geometry of the thoracic aorta based on computed tomography angiography (CTA) in 104 subsequently patients receiving TAVI with SEV devices (Evolut R). Prosthesis position was determined using the fusion imaging method of pre- and post-procedural CTA. An implantation depth of ≥4 mm was defined as the cut-off value for low prosthesis position. RESULTS: The mean implantation depth of the THV in the whole cohort was 4.3 ± 3.0 mm below annulus plane. THV position was low in 66 (63.5%) patients and high in 38 (36.5%) patients. After multivariate adjustment none of the aortic geometry characteristics showed an independent influence on the prosthesis position-neither the Sinus of Valsalva area (p = 0.335) nor the proximal aortic arch diameter (p = 0.754) or the distance from annulus to descending aorta (p = 0.309). CONCLUSION: The geometry of the thoracic aorta showed no influence on the positioning of self-expanding TAVI valve types.

18.
JACC Cardiovasc Interv ; 15(11): 1113-1122, 2022 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-35680190

RESUMO

BACKGROUND: Early hypoattenuated leaflet thickening (HALT) occurs in at least 10% of all transcatheter aortic valve replacement (TAVR) patients. The long-term prognostic impact of HALT is uncertain. OBJECTIVES: The aim of this study was to assess the long-term risk of early HALT post-TAVR. METHODS: We report outcome data from our prospective observational registry with post-TAVR computed tomography angiography performed between May 2012 and December 2017. The outcomes were survival, cardiovascular mortality, ischemic cerebrovascular events, and symptomatic hemodynamic valve deterioration. RESULTS: Early HALT was diagnosed in 115 (16.0%) of 804 patients. During a median follow-up of 3.25 years, survival rates did not differ significantly between patients with and without HALT (Kaplan-Meier 3-year estimates for survival 70.1% vs 74.0%, P = 0.597). The 3-year cardiovascular mortality rate was 13.2% versus 11.3% (with vs without HALT, P = 0.733). The 3-year event rate for cerebrovascular events was 2.0% versus 4.4% (with vs without HALT, P = 0.246), and the 3-year event rate of symptomatic hemodynamic valve deterioration was 9.4% versus 1.5% (with vs without HALT, P < 0.001). Multivariable analysis revealed the following predictors of symptomatic hemodynamic valve deterioration: HALT (HR: 6.10; 95% CI: 2.59-14.29; P < 0.001), the mixed valve-type group (HR: 6.51; 95% CI: 2.38-17.81; P < 0.001), and prosthesis diameter (HR valve size per 3 mm [HR: 0.37; 95% CI: 0.17-0.79]; P = 0.011). CONCLUSIONS: During a median follow-up of more than 3 years, HALT was not associated with mortality or cerebrovascular events. However, we observed an association of HALT with symptomatic hemodynamic valve deterioration.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Seguimentos , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
19.
J Clin Med ; 11(7)2022 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-35407425

RESUMO

(1) Background: Early hypo-attenuated leaflet thickening (HALT) is diagnosed by computed tomography angiography (CTA) in approximately 15% of patients undergoing transcatheter aortic valve replacement (TAVR). We sought to investigate the diagnostic performance of CTA for the diagnosis of HALT, focusing on timing data assessment within the cardiac cycle. (2) Methods: The study enrolled 50 patients with and 50 without HALT with available post-TAVR-CTA. The primary objective was to compare the diagnostic performance of CTA readings at specific intervals and time points during the cardiac cycle (entire systole, entire diastole, end-systole, and mid-diastole) versus gold standard (consensus reading by two observers based on multiphase full cardiac cycle data sets). (3) Results: 100 CTAs were independently analysed by two observers blinded to clinical characteristics of the study population and the results from the gold standard reading. Sensitivity and specificity for the diagnosis of HALT were 84%/94% in systole, 87%/92% in diastole, 78%/95% at end-systole, and 80%/94% at mid-diastole. End-systole had the highest positive predictive value (0.88) and positive likelihood ratio (36). Cohen's kappa for interobserver reliability was 0.715 in systole, 0.578 in diastole, 0.650 at end-systole, and 0.517 at mid-diastole. (4) Conclusion: Limiting CTA reading to distinct intervals or time points during the cardiac cycle has good specificity but lowers sensitivity. For a reliable diagnosis of HALT, data sets from a multiphase CTA covering the entire cardiac cycle should be analysed. A double reader approach would be desirable in further studies investigating HALT.

20.
J Clin Med ; 11(19)2022 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-36233773

RESUMO

Aims: Exercise stress testing can stratify specific populations of heart failure patients for mortality risk, but is not universally applied. The aim of the present study was to investigate the prognostic capabilities of invasive exercise testing in a real-world cohort of suspected heart failure patients in whom non-cardiac causes of dyspnea were excluded. Methods: We retrospectively analyzed the survival of 682 patients who underwent right heart catheterization at rest and during exercise between 2007 and 2017 for dyspnea and expected heart failure. Pulmonary capillary wedge pressure (PCWP) at rest and the PCWP response to exercise, expressed as the ratio of PCWP at peak exercise to workload normalized to body weight (PCWL (mmHg/W/kg)), were determined. Mortality data were retrieved from the official German death registry. Results: Over a median follow-up period of 8.5 years, PCWL is a stronger predictor of all-cause mortality than PCWP. Patients featuring a reduced left ventricular ejection fraction (LVEF; <50%), but favorable response to exercise (PCWL <34.7 mmHg/W/kg), have a similar mortality risk to patients with a normal LVEF and low PCWL (hazard ratio (HR) 1.180, 95% CI 0.48−2.91, p = 0.719). Irrespective of LVEF, an increased PCWL during exercise was associated with a significantly increased mortality (HR 1.950 with preserved LVEF, 95% CI 1.12−3.34, p = 0.018; and HR 3.212 with impaired LVEF, 95% CI 1.75−5.70, p < 0.001). Conclusions: In patients with clinical heart failure, invasive exercise testing improves the prediction of mortality. Subjects with a favorable response to exercise have a relatively low mortality irrespective of left ventricular systolic function.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA