Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Radiol Prot ; 44(1)2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38295404

RESUMO

Radioactive seed localization (RSL) provides a precise and efficient method for removing non-palpable breast lesions. It has proven to be a valuable addition to breast surgery, improving perioperative logistics and patient satisfaction. This retrospective review examines the lessons learned from a high-volume cancer center's RSL program after 10 years of practice and over 25 000 cases. We provide an updated model for assessing the patient's radiation dose from RSL seed implantation and demonstrate the safety of RSL to staff members. Additionally, we emphasize the importance of various aspects of presurgical evaluation, surgical techniques, post-surgical management, and regulatory compliance for a successful RSL program. Notably, the program has reduced radiation exposure for patients and medical staff.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Mastectomia Segmentar/métodos , Radioisótopos do Iodo , Mama , Estudos Retrospectivos
2.
J Radiol Prot ; 43(3)2023 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-37413983

RESUMO

The goal of this study is to investigate the effect of the location and width of a single lead shield on the dose rate of staff and caregivers in a hospital room with an I-131 patient. The best orientation of the patient and caregiver relative to the shield was determined based on minimizing staff and caregiver radiation dose rates. Shielded and unshielded dose rates were simulated using a Monte Carlo computer simulation and validated using real-world ionisation chamber measurements. Based on a radiation transport analysis using an adult voxel phantom published by the International Commission on Radiological Protection, placing the shield near the caregiver yielded the lowest dose rates. However, this strategy reduced the dose rate in only a tiny area of the room. Furthermore, positioning the shield near the patient in the caudal direction provided a modest dose rate reduction while shielding a large room area. Finally, increased shield width was associated with decreasing dose rates, but only a four-fold dose-rate reduction was observed for standard width shields. The recommendations of this case study may be considered as potential candidate room configurations where radiation dose rates are minimized, however these findings must be weighed against additional clinical, safety, and comfort considerations.


Assuntos
Cuidadores , Compostos Radiofarmacêuticos , Adulto , Humanos , Doses de Radiação , Radioisótopos do Iodo/uso terapêutico , Simulação por Computador , Imagens de Fantasmas
3.
Radiat Prot Dosimetry ; 192(3): 321-327, 2020 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-33320204

RESUMO

This paper summarizes the dose to the eye lens of workers of Memorial Sloan Kettering Cancer Center, a high-volume US oncologic and associated diseases facility. The doses presented in this report were collected from personal dosemeter readings using optically stimulated luminescence badges to estimate Hp(3). Doses were collected for 5950 clinical and research workers between January 2012 and December 2017. The median eye lens dose for all monitored workers was 0.23 mSv y-1. Workers performing, or supporting, fluoroscopy procedures received the highest unprotected eye lens dose of all workers with a median eye dose of 10 mSv. The use of leaded glasses by this group reduced the actual doses to the lens. Nurses and technicians involved in positron emission tomography injections received median eye lens dose of 1.2 mSv.


Assuntos
Cristalino , Exposição Ocupacional , Proteção Radiológica , Humanos , Exposição Ocupacional/análise , Doses de Radiação , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA