Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Endoscopy ; 53(4): 346-353, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32663877

RESUMO

BACKGROUND: Flexible endoscopic myotomy has been increasingly performed for Zenker's diverticulum using various endoscopic techniques and devices. The main aims of this study were to assess practice patterns and compare outcomes of endoscopic myotomy for Zenker's diverticulum. METHODS: Procedures performed at 12 tertiary endoscopy centers from 1/2012 to 12/2018 were reviewed. Patients (≥ 18 years) with Zenker's diverticulum who had dysphagia and/or regurgitation and underwent endoscopic myotomy were included. Outcomes assessed included technical success, clinical success, and adverse events. RESULTS: 161 patients were included. Traditional endoscopic septotomy was performed most frequently (137/161, 85.1 %) followed by submucosal dissection of the septum and myotomy (24/161, 14.9 %). The hook knife (43/161, 26.7 %) and needle-knife (33/161, 20.5 %) were used most frequently. Overall, technical and clinical success rates were 98.1 % (158/161) and 78.1 % (96/123), respectively. Adverse events were noted in 13 patients (8.1 %). There was no significant difference in technical and clinical success between traditional septotomy and submucosal dissection groups (97.1 % vs. 95.8 %, P = 0.56 and 75.2 % vs. 90.9 %, P  = 0.16, respectively). Clinical success was higher with the hook knife (96.7 %) compared with the needle-knife (76.6 %) and insulated tip knife (47.1 %). Outcomes were similar between centers performing > 20, 11 - 20, and ≤ 10 procedures. CONCLUSIONS: Flexible endoscopic myotomy is an effective therapy for Zenker's diverticulum, with a low rate of adverse events. There was no significant difference in outcomes between traditional septotomy and a submucosal dissection approach, or with centers with higher volume, though clinical success was higher with the hook knife.


Assuntos
Transtornos de Deglutição , Miotomia , Divertículo de Zenker , Transtornos de Deglutição/etiologia , Esofagoscopia , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Divertículo de Zenker/cirurgia
2.
Am J Gastroenterol ; 114(2): 305-314, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30730859

RESUMO

OBJECTIVES: National societies provide little guidance regarding which colonoscopy bowel preps are best tolerated and most effective; this reflects a lack of comparative effectiveness studies that directly evaluate the available preps in a "real-world" setting. To address this gap, we conducted a prospective, commercially unfunded comparative effectiveness study of currently available bowel preps and measured their impact on bowel cleansing. METHODS: We included patients aged ≥18 years, who presented for an outpatient colonoscopy at a large medical center serving more than 70 academic and community-based endoscopists who are free to prescribe the bowel prep of their choice. The primary outcome was bowel cleansing quality as measured by the Boston Bowel Preparation Scale. We performed regression models with random effects on the outcomes to adjust for confounding. RESULTS: Approximately 4,339 colonoscopies were performed by 75 endoscopists. Magnesium citrate, MiraLAX with Gatorade, MoviPrep, OsmoPrep, Prepopik/Clenpiq, and Suprep all had significantly higher prep tolerability compared with GoLYTELY (all P < 0.05). For bowel cleansing, Suprep (7.28 ± 1.66; P < 0.001), MoviPrep (7.11 ± 1.62; P = 0.004), and MiraLAX with Gatorade (7.09 ± 1.64; P < 0.001) had higher total Boston Bowel Preparation Scale scores compared with GoLYTELY (6.67 ± 1.87); there were no significant differences among the remaining preps. Split-prep dosing was associated with better cleansing; however, men, opioid and tricyclic antidepressent users, and patients with diabetes and cirrhosis had worse cleansing (all P < 0.05). CONCLUSIONS: In this prospective, real-world comparative effectiveness study of available bowel preps, we found that MiraLAX with Gatorade, MoviPrep, and Suprep were prospectively associated with superior tolerability and bowel cleansing.


Assuntos
Catárticos/uso terapêutico , Colonoscopia/métodos , Adolescente , Adulto , Idoso , Ácido Cítrico , Eletrólitos , Feminino , Humanos , Soluções Isotônicas , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Polietilenoglicóis , Estudos Prospectivos , Adulto Jovem
4.
BMJ Case Rep ; 12(11)2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31791992

RESUMO

Gastrointestinal stromal tumours (GISTs) only account for a small percentage of gastrointestinal malignancies with a wide range of clinical presentations depending on the location and size of the tumour. Herein, we present the case of a 55-year-old woman with occult gastrointestinal bleeding (GIB) despite imaging and two separate oesophagogastroduodenoscopy colonoscopies. On double-balloon enteroscopy, an oozing diverticular-appearing lesion in the ileum was identified which on laparoscopy was connected to a large pelvic GIST. This case highlights the importance of considering GISTs in patients with occult GIB, as a high index of suspicion is required for diagnosis.


Assuntos
Divertículo/diagnóstico , Hemorragia Gastrointestinal/diagnóstico , Neoplasias Gastrointestinais/diagnóstico , Tumores do Estroma Gastrointestinal/diagnóstico , Diagnóstico Diferencial , Enteroscopia de Duplo Balão , Feminino , Humanos , Pessoa de Meia-Idade
5.
J Vis Exp ; (83): e3298, 2014 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-24429915

RESUMO

In the present work, we demonstrate a method for concurrent collection of EEG/fMRI data. In our setup, EEG data are collected using a high-density 256-channel sensor net. The EEG amplifier itself is contained in a field isolation containment system (FICS), and MRI clock signals are synchronized with EEG data collection for subsequent MR artifact characterization and removal. We demonstrate this method first for resting state data collection. Thereafter, we demonstrate a protocol for EEG/fMRI data recording, while subjects listen to a tape asking them to visualize that their left hand is immersed in a cold-water bath and referred to, here, as the cold glove paradigm. Thermal differentials between each hand are measured throughout EEG/fMRI data collection using an MR compatible temperature sensor that we developed for this purpose. We collect cold glove EEG/fMRI data along with simultaneous differential hand temperature measurements both before and after hypnotic induction. Between pre and post sessions, single modality EEG data are collected during the hypnotic induction and depth assessment process. Our representative results demonstrate that significant changes in the EEG power spectrum can be measured during hypnotic induction, and that hand temperature changes during the cold glove paradigm can be detected rapidly using our MR compatible differential thermometry device.


Assuntos
Eletroencefalografia/métodos , Imageamento por Ressonância Magnética/métodos , Termografia/métodos , Sensação Térmica/fisiologia , Temperatura Baixa , Eletroencefalografia/instrumentação , Mãos/fisiologia , Humanos , Hipnose/métodos , Imageamento por Ressonância Magnética/instrumentação , Termografia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA