Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Respirology ; 18(7): 1135-42, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23714281

RESUMO

BACKGROUND AND OBJECTIVE: The use of continuous positive airway pressure (CPAP) treatment in patients with obesity hypoventilation syndrome (OHS) and obstructive sleep apnoea (OSA) was evaluated, and factors that might predict CPAP treatment failure were determined. METHODS: A sleep study was performed in 29 newly diagnosed, clinically stable OHS patients. CPAP treatment was commenced if the apnoea-hypopnoea index was >15. Lung function, night-time oximetry, blood adipokine and C-reactive protein levels were assessed prospectively on enrollment and after 3 months. Treatment failure at 3 months was defined as daytime arterial partial pressure of carbon dioxide (PaCO(2)) >45 mm Hg and/or oxygen saturation (SpO(2)) <90% for >30% of the night-time oximetry study. RESULTS: All patients had severe OSA (median apnoea-hypopnoea index = 74.7 (62-100) with a nocturnal mean SpO(2) of 81.4 ± 7), and all patients were treated with CPAP. The percentage of time spent below 90% saturation improved from 8.4% (0.0-39.0%) to 0.3% (0.4-4.0%). Awake PaCO(2) decreased from 50 (47-53) mm Hg to 43 (40-45) mm Hg. Seven patients failed CPAP treatment after 3 months. PaCO(2) at 1 month and mean night-time SpO(2) during the first night of optimal CPAP were associated with treatment failure at 3 months (odds ratio 1.4 (1.03-1.98); P = 0.034 and 0.6 (0.34-0.93); P = 0.027). CONCLUSIONS: CPAP treatment improves night-time oxygenation and daytime hypoventilation in selected clinically stable OHS patients who also have OSA. Patients with worse night-time saturation while on CPAP and higher daytime PaCO(2) at 1 month were more likely to fail CPAP treatment.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Síndrome de Hipoventilação por Obesidade/terapia , Índice de Gravidade de Doença , Apneia Obstrutiva do Sono/terapia , Adipocinas/metabolismo , Idoso , Proteína C-Reativa/metabolismo , Dióxido de Carbono/metabolismo , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Síndrome de Hipoventilação por Obesidade/metabolismo , Oximetria , Oxiemoglobinas/metabolismo , Polissonografia , Estudos Prospectivos , Estudos Retrospectivos , Apneia Obstrutiva do Sono/metabolismo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA