Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Clin Exp Dent ; 15(4): e298-e303, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37152501

RESUMO

Background: Mini-implants are devices used to provide absolute and temporary anchorage for tooth movement. Objectives: The present study was carried out to compare the use of periapical radiographs and computed tomography (CT) for planning mini-implants performed by orthodontists. Material and Methods: Five radiographs and five CT scans of premolars and molars regions. These were analyzed by ten Orthodontists. Initially (T1), the evaluators indicated the preferred location for the insertion of a mini-implant, as well as the diameter and length of the device, using only a periapical radiograph. After 30 days (T2), the same evaluation was performed. Sixty days later (T3), the orthodontists reassessed the radiographs in association with the CT scans. Finally, after 90 days (T4), the evaluation was performed with the same exams. The comparison of the chosen diameter and length of the mini-implants was performed using the Student's t-test. The evaluation of the chosen insertion sites was analyzed by the Wilcoxon test. For both tests, the level of significance was 5%. The kappa concordance test was also performed for the intra- and inter-examiner evaluations. Results: The results of the study showed substantial or perfect intra-examiner and reasonable to perfect inter-examiner agreement. Considering the length and diameter of the mini-implants, no statistical difference was found between the groups. Regarding the insertion site, more than 20% of the treatment plans were changed when the CT scan was associated. Conclusions: The results showed that the association of a CT scan with radiography frequently leads the professional to change the insertion point for the installation of mini-implants. Key words:Orthodontic anchorage procedures. Mini Dental Implants. Bone Screws. Cone-beam computed tomography. Periapical radiography.

2.
Artigo em Inglês | LILACS, BBO | ID: biblio-1550590

RESUMO

ABSTRACT Objective: To guide professionals about the criteria for replacing amalgam restorations and inform them about the new guidelines regarding the use/indication of this (amalgam) material after the Minamata Convention - COP-4. Material and Methods: The articles were selected from the databases (PubMed, Scielo, Bireme), and relevant articles on the subject between the years 2003-2021 were selected. Recently, social media have been flooded with dental treatments that aim to perform restorations only with composite resins or other types of esthetic material and completely replace all dental amalgam restorations, irrespective of their time in place, size, and functionality. Results: Although improperly, it has been noted that this information reaches patients, and they are led to believe in the inaccurate data that is passed on, such as, for example, (that amalgam leads to) permanent contamination by mercury, causing systemic problems and the loss of the tooth. Conclusion: The "phase down" of amalgam in research and teaching has previously been observed in several countries worldwide; however, its use is still necessary given particular circumstances, which, theoretically, make it a material with exact indication.


Assuntos
Amálgama Dentário/química , Materiais Dentários , Restauração Dentária Permanente , Efeitos Adversos de Longa Duração , Estudos Longitudinais , Resinas Compostas
3.
RGO (Porto Alegre) ; 70: e20220043, 2022. tab
Artigo em Inglês | LILACS-Express | LILACS, BBO | ID: biblio-1406502

RESUMO

ABSTRACT Introduction: Composite resins are an extensively used esthetic material that has excellent adaptation, reproduces the characteristics of the tooth structure and is suitable for the conditions of the oral environment. However, this material is also very susceptible to staining due to pigmentation coming from the diet and habits of the patient. Objectives: To evaluate the staining of two brands of composite resin, one nanoparticle and a nanohybrid type (Filtek Z350XT® and IPS Empress Direct®), in direct contact with the acid pH of beverages. Methods: In total 40 specimens were made, 20 of each type of resin studied. After being inserted into a Teflon matrix and light activated, the samples were removed, stored in containers with 2 ml of artificial saliva and kept in the refrigerator. Every day 20 of these samples were placed in direct contact with 2 ml Gatorade, and the other 20 samples, in 2 ml of wine, each set for 30 minutes. After 30 minutes, the acid pH substances were removed, and 2 ml of artificial saliva was again placed in the container. This process was repeated every day for 10 days. Results: The results showed that the nanoparticle resin (Filtek Z350XT) was more susceptible to staining than the nanohybrid type (Empress Direct®) when in contact with the wine. When wine and Gatorade were compared, the solution with higher staining capacity was shown to be wine. Conclusion: The two resins tested were susceptible to staining in a 10-day period. Mottling and more staining was visibly detected after samples were immersed in the solution with the higher pH, and nanoparticulate resin was more susceptible to staining.


RESUMO Introdução: As resinas compostas são altamente utilizadas por serem um material estético, com excelente adaptação, reproduz as características da estrutura dental e se adequa ao meio bucal. Porém, este material é muito susceptível à pigmentação por corantes vindos da dieta e de hábitos do paciente. Objetivos: Avaliar o manchamento de duas marcas comerciais de resina composta: Nanoparticulada e Nanohíbrida, em contato direto com bebidas de pH ácido (Filtek Z350XT® e IPS Empress Direct®). Métodos: Foram confeccionados 40 corpos de prova, 20 de cada tipo de resina estudada, depois de inseridas em matriz de teflon e fotoativados, os corpos de prova foram removidos, armazenados em recipientes com 2ml de saliva artificial e mantidos na geladeira. Diariamente 20 dos mesmos eram colocados em contato direto com 20mL Gatorade e os outros 20mL de vinho durante 30 minutos cada. Passados os 30 minutos, as substâncias de pH ácido eram retiradas e novamente, 2 mL de saliva artificial eram colocadas no recipiente. Este processo foi repetido todos os dias durante 10 dias. Resultado: Os resultados mostraram que a resina nanoparticulada (Filtek Z350XT®) é mais susceptível ao manchamento que a nanohíbrida (Empress Direct®) quando em contato com o vinho. Quando comparados vinho e Gatorade, a solução com maior teor de manchamento é o vinho. Conclusão: As duas resinas testadas foram sensíveis ao manchamento num período de 10 dias, esse manchamento foi visivelmente detectado, a solução com o pH mais elevado manchou mais e a resina nanoparticulada é mais susceptível ao manchamento.

4.
Braz. j. oral sci ; 21: e226202, jan.-dez. 2022. ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1393187

RESUMO

Aim: Resin modified glass ionomer (RMGI) is class of material that can be used as sealant for preventing and arresting the progression of caries in pits and fissures. As these are hybrid materials, their properties can be affected by factors related to the polymerization process. Therefore, this study aimed to evaluate the influence of different generations of LED curing units (Elipar DeepCure-L and VALO Grand) on Knoop microhardness values (KHN) of RMGI sealants (Clinpro XT and Vitremer). Methods: Forty cylindrical specimens (6mm ø x 1 mm high) were prepared according to the manufacturer's instructions and divided into four groups (n=10) according to the type of RMGI and LED used. The KHN of the top surface of each sample was calculated 7 days after light-curing. Data were submitted to two-way ANOVA (α = 0.05). Results: Vitremer had higher KHN values than Clinpro XT after using both LEDs (p<0.0001), but especially when light-cured with the use of VALO Grand (p<0.0001). Whereas the KHN value of Clinpro was not influenced by the LED device (p>0.05). Conclusions: Top surface microhardness values of RGMI sealants were affected by both material composition and generations of LED curing units used. Third generation LED curing units seemed to be more efficient for the polymerization of RMGI-based sealants


Assuntos
Selantes de Fossas e Fissuras , Lâmpadas de Polimerização Dentária , Polimerização , Dureza
5.
Compend Contin Educ Dent ; 33(10): E130-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23631532

RESUMO

Anterior teeth fractures are frequently encountered in clinical practice. The reattachment of dental fragments, if possible, is a conservative and effective technique, which is utilized in this case. This case presentation concerns an 18-year-old male patient with a root-crown fracture of the left maxillary central incisor, which involves the periodontal biologic space. The treatment was the reattachment of the dental fragment with a composite resin and adhesive, in association with periodontal surgery. The reattachment technique described in this case report is simple, but it provides long-lasting esthetics and improved function via a very conservative approach.


Assuntos
Restauração Dentária Permanente/métodos , Estética Dentária , Incisivo/lesões , Fraturas dos Dentes/terapia , Adolescente , Resinas Compostas/química , Colagem Dentária/métodos , Esmalte Dentário/lesões , Dentina/lesões , Humanos , Masculino , Maxila , Periodonto/cirurgia , Agentes de Capeamento da Polpa Dentária e Pulpectomia/uso terapêutico , Cimentos de Resina/química , Retalhos Cirúrgicos/cirurgia , Coroa do Dente/lesões , Raiz Dentária/lesões
6.
Braz Oral Res ; 25(2): 168-73, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21537643

RESUMO

The aim of this in vitro study was to evaluate the effect of different mouthwashes on superficial roughness and Knoop hardness of two resin composites. Eighty specimens (6 mm Ø and 2 mm height) were prepared and divided into eight experimental groups (n = 10) according to the resin composites (4 Seasons and Esthet X), and storage solutions (G1 - Distilled water; G2 - Colgate Plax Overnight; G3 - Colgate Plax Alcohol Free; and G4 - Colgate Plax Whitening). The initial hardness and roughness readings (T1) were measured and then the specimens were stored in 2 mL of mouthwash for 12 h (T2) and 24 h (T3). The data were analyzed with repeat-measures two-way ANOVA and Tukey's test (α = 5%). Regardless of the type of solution and time of exposure, there was no statistical difference for roughness between the resins (p = 0.44). G4 and G8 presented higher roughness means than G1, G3, G5 and G7, after 12 and 24 hours of immersion. For Knoop microhardness analysis, there was a significant reduction for all groups after 12 hours and 24 hours. We conclude that the mouthwashes containing hydrogen peroxide and/or alcohol decrease the microhardness of the resins tested; however, the mouthwash containing hydrogen peroxide had a higher deleterious effect on roughness.


Assuntos
Resinas Compostas/química , Antissépticos Bucais/farmacologia , Análise de Variância , Testes de Dureza , Humanos , Peróxido de Hidrogênio/química , Imersão , Teste de Materiais , Estatísticas não Paramétricas , Propriedades de Superfície/efeitos dos fármacos , Fatores de Tempo
7.
J. res. dent ; 2(2): 176-188, 2014. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: lil-715033

RESUMO

AIM: This study aimed to evaluate the enamel microhardness, surface roughness, and chemical composition after microabrasion technique, followed by polishing and different immersion times in artificial saliva. Materials and methods: Ninety enamel blocks (25mm2) from bovine incisors were divided into two groups (G1 and G2), and then subdivided in five subgroups (n = 9) according to their microabrasion treatment and polishing with a diamond paste: 35% phosphoric acid and pumice (H3PO4+Pum) and polishing; just H3PO4+Pum; 6.6% hydrochloric acid and silica (HCl+Sil) and polishing; just HCl+Sil; and control (no treatment). For G1, roughness and microhardness analyses were performed before (L1) and after (L2) microabrasion. After 15 (L3) and 30 (L4) days of immersion in artificial saliva, microhardness analysis was also performed. After (L4) analysis, the specimens were subjected to SEM analysis. G2 was used for the chemical analysis using energy dispersion testing (EDS). The data was subjected to statistical analysis (α = 5%). For roughness, L2 presented higher values than L1, except for the polished groups. For microhardness, L2 presented higher values than L1, except for unpolished groups. The L3 and L4 did not differ and were higher than L1. RESULTS: No changes were observed in the phosphorus concentrations of the microabrasioned enamel. However, the specimens treated with HCl+Sil were observed as having decreased calcium and increased chlorine and silica on the EDS test. Conclusion: Microabrasion followed by polishing and immersion in artificial saliva for 15 days is enough to increase the microhardness of microabrasioned enamel surfaces, although the microabrasion procedure can alter the mineral content of the enamel.


Assuntos
Ácido Clorídrico/química , Esmalte Dentário/fisiologia , Microabrasão do Esmalte , Incisivo , Timol
8.
Braz. oral res ; 25(2): 168-173, Mar.-Apr. 2011. tab
Artigo em Inglês | LILACS | ID: lil-583852

RESUMO

The aim of this in vitro study was to evaluate the effect of different mouthwashes on superficial roughness and Knoop hardness of two resin composites. Eighty specimens (6 mm Ø and 2 mm height) were prepared and divided into eight experimental groups (n = 10) according to the resin composites (4 Seasons and Esthet X), and storage solutions (G1 - Distilled water; G2 - Colgate Plax Overnight; G3 - Colgate Plax Alcohol Free; and G4 - Colgate Plax Whitening). The initial hardness and roughness readings (T1) were measured and then the specimens were stored in 2 mL of mouthwash for 12 h (T2) and 24 h (T3). The data were analyzed with repeat-measures two-way ANOVA and Tukey's test (α = 5 percent). Regardless of the type of solution and time of exposure, there was no statistical difference for roughness between the resins (p = 0.44). G4 and G8 presented higher roughness means than G1, G3, G5 and G7, after 12 and 24 hours of immersion. For Knoop microhardness analysis, there was a significant reduction for all groups after 12 hours and 24 hours. We conclude that the mouthwashes containing hydrogen peroxide and/or alcohol decrease the microhardness of the resins tested; however, the mouthwash containing hydrogen peroxide had a higher deleterious effect on roughness.


Assuntos
Humanos , Resinas Compostas/química , Antissépticos Bucais/farmacologia , Análise de Variância , Testes de Dureza , Peróxido de Hidrogênio/química , Imersão , Teste de Materiais , Estatísticas não Paramétricas , Propriedades de Superfície/efeitos dos fármacos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA