Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur J Radiol ; 176: 111483, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38705051

RESUMO

BACKGROUND: The pathological mechanisms following aneurysmal subarachnoid hemorrhage (SAH) are poorly understood. Limited clinical evidence exists on the association between cerebrospinal fluid (CSF) volume and the risk of delayed cerebral ischemia (DCI) or cerebral vasospasm (CV). In this study, we raised the hypothesis that the amount of CSF or its ratio to hemorrhage blood volume, as determined from non-contrast Computed Tomography (NCCT) images taken on admission, could be a significant predictor for CV and DCI. METHODS: The pilot study included a retrospective analysis of NCCT scans of 49 SAH patients taken shortly after an aneurysm rupture (33 males, 16 females, mean age 56.4 ± 15 years). The SynthStrip and Slicer3D software tools were used to extract radiological factors - CSF, brain, and hemorrhage volumes from the NCCT images. The "pure" CSF volume (VCSF) was estimated in the range of [-15, 15] Hounsfield units (HU). RESULTS: VCSF was negatively associated with the risk of CV occurrence (p = 0.0049) and DCI (p = 0.0069), but was not associated with patients' outcomes. The hemorrhage volume (VSAH) was positively associated with an unfavorable outcome (p = 0.0032) but was not associated with CV/DCI. The ratio VSAH/VCSF was positively associated with, both, DCI (p = 0.031) and unfavorable outcome (p = 0.002). The CSF volume normalized by the brain volume showed the highest characteristics for DCI prediction (AUC = 0.791, sensitivity = 0.80, specificity = 0.812) and CV prediction (AUC = 0.769, sensitivity = 0.812, specificity = 0.70). CONCLUSION: It was demonstrated that "pure" CSF volume retrieved from the initial NCCT images of SAH patients (including CV, Non-CV, DCI, Non-DCI groups) is a more significant predictor of DCI and CV compared to other routinely used radiological biomarkers. VCSF could be used to predict clinical course as well as to personalize the management of SAH patients. Larger multicenter clinical trials should be performed to test the added value of the proposed methodology.


Assuntos
Hemorragia Subaracnóidea , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/líquido cefalorraquidiano , Hemorragia Subaracnóidea/complicações , Pessoa de Meia-Idade , Projetos Piloto , Estudos Retrospectivos , Líquido Cefalorraquidiano/diagnóstico por imagem , Vasoespasmo Intracraniano/diagnóstico por imagem , Vasoespasmo Intracraniano/líquido cefalorraquidiano , Vasoespasmo Intracraniano/etiologia , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/líquido cefalorraquidiano , Isquemia Encefálica/complicações , Idoso , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/complicações , Aneurisma Roto/líquido cefalorraquidiano , Valor Preditivo dos Testes , Adulto , Sensibilidade e Especificidade
2.
Sci Rep ; 11(1): 4736, 2021 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-33637806

RESUMO

Intracranial pressure (ICP) monitoring is important in managing neurosurgical, neurological, and ophthalmological patients with open-angle glaucoma. Non-invasive two-depth transcranial Doppler (TCD) technique is used in a novel method for ICP snapshot measurement that has been previously investigated prospectively, and the results showed clinically acceptable accuracy and precision. The aim of this study was to investigate possibility of using the ophthalmic artery (OA) as a pressure sensor for continuous ICP monitoring. First, numerical modeling was done to investigate the possibility, and then a pilot clinical study was conducted to compare two-depth TCD-based non-invasive ICP monitoring data with readings from an invasive Codman ICP microsensor from patients with severe traumatic brain injury. The numerical modeling showed that the systematic error of non-invasive ICP monitoring was < 1.0 mmHg after eliminating the intraorbital and blood pressure gradient. In a clinical study, a total of 1928 paired data points were collected, and the extreme data points of measured differences between invasive and non-invasive ICP were - 3.94 and 4.68 mmHg (95% CI - 2.55 to 2.72). The total mean and SD were 0.086 ± 1.34 mmHg, and the correlation coefficient was 0.94. The results show that the OA can be used as a linear natural pressure sensor and that it could potentially be possible to monitor the ICP for up to 1 h without recalibration.


Assuntos
Lesões Encefálicas Traumáticas/diagnóstico por imagem , Pressão Intracraniana , Artéria Oftálmica/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/métodos , Adulto , Velocidade do Fluxo Sanguíneo , Lesões Encefálicas Traumáticas/fisiopatologia , Feminino , Humanos , Masculino , Modelos Teóricos , Monitorização Fisiológica/métodos , Projetos Piloto
3.
Int J Numer Method Biomed Eng ; 35(6): e3194, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30817080

RESUMO

The advanced constitutive material models of artery wall require the definition of the mean collagen fiber directions in the material configuration. There are several proposed methods; however, it is unclear how much does the fiber structures obtained by these methods differ one from the other and how much this difference may affect the results of the structural analysis of a clinically relevant scenario. Therefore, in this paper, we address this issue by presenting the results of the comparative study of our developed and currently state-of-the-art fiber definition methods. In addition, we present the verification of our developed numerical model that incorporates the extended Holzapfel-Gasser-Ogden (HGO) constitutive material model and the generalized prestressing algorithm (GPA). In the case of the patient-specific internal carotid artery (ICA), the percentage error of the mean fiber directions defined by different methods does not exceed 17.73% (at least 0.05%, at most 81.82%) and has negligible effect on the stress levels, as the percentage error of the mean circumferential Cauchy stress does not exceed 0.1%. Both fiber definition methods produce comparable fiber structure, but our proposed method has an advantage, as it does not depend on method and software used to model the arterial wall mechanics.


Assuntos
Artérias/anatomia & histologia , Análise Numérica Assistida por Computador , Algoritmos , Fenômenos Biomecânicos , Artéria Carótida Interna/anatomia & histologia , Simulação por Computador , Humanos , Imageamento por Ressonância Magnética , Modelos Cardiovasculares , Estresse Mecânico
5.
Comput Biol Med ; 84: 79-88, 2017 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28346876

RESUMO

Accurate and clinically safe measurements of intracranial pressure (ICP) are crucial for secondary brain damage prevention. There are two methods of ICP measurement: invasive and noninvasive. Invasive methods are clinically unsafe; therefore, safer noninvasive methods are being developed. One of the noninvasive ICP measurement methods implements the balance principle, which assumes that if the velocity of blood flow in both ophthalmic artery segments - the intracranial (IOA) and extracranial (EOA) - is equal, then the acting ICP on the IOA and the external pressure (Pe) on the EOA are also equal. To investigate the assumption of the balance principle, a generalized computational model incorporating a fluid-structure interaction (FSI) module was created and used to simulate noninvasive ICP measurement by accounting for the time-dependent behavior of the elastic internal carotid (ICA) and ophthalmic (OA) arteries and their interaction with pulsatile blood flow. It was found that the extra balance pressure term, which incorporates the hydrodynamic pressure drop between measurement points, must be added into the balance equation, and the corrections on a difference between the velocity of blood flow in the IOA and EOA must be made, due to a difference in the blood flow rate.


Assuntos
Artéria Carótida Interna/fisiologia , Pressão Intracraniana/fisiologia , Modelos Biológicos , Artéria Oftálmica/fisiologia , Biologia Computacional , Humanos , Hidrodinâmica , Exame Físico , Fluxo Pulsátil/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA