Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Langmuir ; 39(20): 7063-7078, 2023 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-37159941

RESUMO

The adhesion between silica surfaces and epoxy resins was investigated via molecular dynamics (MD) simulations with stable atomic models of silica substrates prepared by density functional theory (DFT) calculations and reactive force field (ReaxFF) MD simulations. We aimed to develop reliable atomic models for evaluating the effect of nanoscale surface roughness on adhesion. Three consecutive simulations were performed: (i) stable atomic modeling of silica substrates; (ii) network modeling of epoxy resins by pseudo-reaction MD simulations; and (iii) virtual experiments via MD simulations with deformations. We prepared stable atomic models of OH- and H-terminated silica surfaces based on a dense surface model to consider the native thin oxidized layers on silicon substrates. Moreover, a stable silica surface grafted with epoxy molecules as well as nano-notched surface models were constructed. Cross-linked epoxy resin networks confined between frozen parallel graphite planes were prepared by pseudo-reaction MD simulations with three different conversion rates. Tensile tests using MD simulations indicated that the shape of the stress-strain curve was similar for all models up to near the yield point. This behavior indicated that the frictional force originated from chain-to-chain disentanglements when the adhesion between the epoxy network and silica surfaces was sufficiently strong. MD simulations for shear deformation indicated that the friction pressures in the steady state for the epoxy-grafted silica surface were higher than those for the OH- and H-terminated surfaces. The slope of the stress-displacement curve was steeper for surfaces with deeper notches (approximately 1 nm in depth), although the friction pressures for the examined notched surfaces were similar to those for the epoxy-grafted silica surface. Thus, nanometer-scale surface roughness is expected to have a large impact on the adhesion between polymeric materials and inorganic substrates.

2.
Circ J ; 86(2): 256-265, 2022 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-34334554

RESUMO

BACKGROUND: The use of iodine contrast agents is one possible limitation in cryoballoon ablation (CBA) for atrial fibrillation (AF). This study investigated intracardiac echography (ICE)-guided contrast-free CBA.Methods and Results:The study was divided into 2 phases. First, 25 paroxysmal AF patients (Group 1) underwent CBA, and peri-balloon leak flow velocity (PLFV) was assessed using ICE and electrical pulmonary vein (PV) lesion gaps were assessed by high-density electroanatomical mapping. Then, 24 patients (Group 2) underwent ICE-guided CBA and were compared with 25 patients who underwent conventional CBA (historical controls). In Group 1, there was a significant correlation between PLFV and electrical PV gap diameter (r=-0.715, P<0.001). PLFV was higher without than with an electrical gap (mean [±SD] 127.0±28.6 vs. 66.6±21.0 cm/s; P<0.001) and the cut-off value of PLFV to predict electrical isolation was 105.7 cm/s (sensitivity 0.700, specificity 0.929). In Group 2, ICE-guided CBA was successfully performed with acute electrical isolation of all PVs and without the need for "rescue" contrast injection. Atrial tachyarrhythmia recurrence at 6 months did not differ between ICE-guided and conventional CBA (3/24 [12.5%] vs. 5/25 [20.0%], respectively; P=0.973, log-rank test). CONCLUSIONS: PLFV predicted the presence of an electrical PV gap after CBA. ICE-guided CBA was feasible and safe, and could potentially be performed completely contrast-free without a decrease in ablation efficacy.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Ecocardiografia/métodos , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
3.
Heart Vessels ; 36(11): 1661-1669, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33830317

RESUMO

This retrospective, single-center study evaluated the patency rate and predictors of restenosis after percutaneous transluminal angioplasty (PTA) for femoropopliteal stenotic lesions using intravascular ultrasound. We assessed 78 de novo femoropopliteal stenotic lesions (64 patients; mean age, 73.6 ± 9.4 years; average lesion length, 59.8 mm) that underwent PTA under intravascular ultrasound guidance. The primary endpoint was 1-year primary patency. The 1-year primary patency rate was 63%. The frequency of insulin use was significantly greater (44% vs. 12%, p = 0.005), and lesions were significantly longer (77.8 mm vs. 49.2 mm, p = 0.047) in the restenosis group than in the non-restenosis group. The pre-intervention reference lumen area and minimum lumen area (MLA) were significantly smaller in the restenosis group (reference lumen area: 19.7 ± 6.7 mm2 vs. 23.7 ± 7.4 mm2, p = 0.017; MLA 3.9 ± 2.8 mm2 vs. 5.7 ± 3.9 mm2, p = 0.026; respectively). The MLA was significantly smaller and the maximum angle of dissection was significantly larger in the restenosis group (MLA 9.3 mm2 vs. 12.3 mm2, p = 0.013; maximum angle of dissection: 104.1° vs. 69.6°, p = 0.003; respectively) among post-intervention parameters. Multivariate analysis revealed that the independent predictors of 1-year restenosis were the large post-intervention maximum angle of dissection and insulin use. Per receiver operating curve analysis, the best cut-off value of the post-intervention maximum angle of dissection that predicted 1-year restenosis was 70.2° (sensitivity 72.4%, specificity 63.3%, area under the curve 0.70, p = 0.004). In conclusion, the 1-year primary patency rate after PTA for relatively short stenotic femoropopliteal lesions was 63%. The large post-intervention maximum angle of dissection, measured using intravascular ultrasound, and insulin use were independent predictors of restenosis after PTA.


Assuntos
Angioplastia com Balão , Insulinas , Idoso , Idoso de 80 Anos ou mais , Angioplastia/métodos , Constrição Patológica , Humanos , Pessoa de Meia-Idade , Artéria Poplítea/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos
4.
Micron ; 187: 103723, 2024 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-39342916

RESUMO

ELNES/XANES spectra can be observed using TEM or synchrotron radiation and can elucidate the unoccupied state electronic structures of an excited states. The computation of their features is usually demanding substantial computational resources due to the requisite structure optimization and electronic structure calculations. Herein, we leverage a machine learning technique alongside an atomic-coordinate-independent descriptor, SMILES, to yield the ELNES/XANES spectra, directly, with heightened precision. Moreover, our approach extends to obtain ground state electronic structure, namely PDOS at both occupied and unoccupied ground states, underscoring its viability for a ground-state spectroscopy. Our study revealed that incorporation of long-SMILES molecules into the training dataset enhances prediction accuracy for such molecular structures. This study's direct derivation of spectroscopy from SMILES strings holds promise for expediting spectroscopic inquiries.

5.
Microscopy (Oxf) ; 73(2): 208-214, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-37702250

RESUMO

We developed an in-situ shear test system suitable for transmission electron microscopy (TEM) observations, which enabled us to examine the shear deformation behaviours inside soft materials at nanoscale resolutions. This study was conducted on a nanoparticle-filled rubber to investigate its nanoscale deformation behaviour under a large shear strain. First, the shear deformation process of a large area in the specimen was accurately examined and proven to exhibit an almost perfect simple shear. At the nanoscale, voids grew along the maximum principal strain during shear deformation. In addition, the nanoscale regions with rubber and silica aggregates exhibited deformation behaviours similar to the global shear deformation of the specimen. Although the silica aggregates exhibited displacement along the shearing directions, rotational motions were also observed owing to the torque generated by the local shear stress. This in-situ shear deformation system for TEM enabled us to understand the nanoscale origins of the mechanical properties of soft materials, particularly polymer composites. Graphical Abstract.

6.
Micron ; 180: 103623, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38461563

RESUMO

The structural characterization of epoxy resins is essential to improve the understanding on their structure-property relationship for promising high-performance applications. Among all analytical techniques, scanning transmission electron microscopy-electron energy-loss spectroscopy (STEM-EELS) is a powerful tool for probing the chemical and structural information of various materials at a high spatial resolution. However, for sensitive materials, such as epoxy resins, the structural damage induced by electron-beam irradiation limits the spatial resolution in the STEM-EELS analysis. In this study, we demonstrated the extraction of the intrinsic features and structural characteristics of epoxy resins by STEM-EELS under electron doses below 1 e-/Å2 at room temperature. The reliability of the STEM-EELS analysis was confirmed by X-ray absorption spectroscopy and spectrum simulation as low- or non-damaged reference data. The investigation of the dependence of the epoxy resin on the electron dose and exposure time revealed the structural degradation associated with electron-beam irradiation, exploring the prospect of EELS for examining epoxy resin at low doses. Furthermore, the degradation mechanisms in the epoxy resin owing to electron-beam irradiation were revealed. These findings can promote the structural characterization of epoxy-resin-based composites and other soft materials.

7.
Nat Commun ; 15(1): 1898, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38459006

RESUMO

The mechanisms underlying the influence of the surface chemistry of inorganic materials on polymer structures and fracture behaviours near adhesive interfaces are not fully understood. This study demonstrates the first clear and direct evidence that molecular surface segregation and cross-linking of epoxy resin are driven by intermolecular forces at the inorganic surfaces alone, which can be linked directly to adhesive failure mechanisms. We prepare adhesive interfaces between epoxy resin and silicon substrates with varying surface chemistries (OH and H terminations) with a smoothness below 1 nm, which have different adhesive strengths by ~13 %. The epoxy resins within sub-nanometre distance from the surfaces with different chemistries exhibit distinct amine-to-epoxy ratios, cross-linked network structures, and adhesion energies. The OH- and H-terminated interfaces exhibit cohesive failure and interfacial delamination, respectively. The substrate surface chemistry impacts the cross-linked structures of the epoxy resins within several nanometres of the interfaces and the adsorption structures of molecules at the interfaces, which result in different fracture behaviours and adhesive strengths.

8.
Nat Commun ; 14(1): 5531, 2023 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-37735491

RESUMO

Semicrystalline polymers are extensively used in various forms, including fibres, films, and bottles. They exhibit remarkable properties, e.g., mechanical and thermal, that are governed by hierarchical structures comprising 10-20-nm-thick lamellar crystals. In 1957, Keller deduced that long polyethylene (PE) chains fold to form thin single lamellar crystals, with the molecular chains perpendicular to the flat faces of the crystals (the chain-folding model). Chains inclining to the perpendicular orientation in single crystals have since been reported, along with their effects on the physical properties of PE. For bulk specimens, the chain tilt angle (φ) has been investigated only for model samples with well-annealed internal structures. However, for briefly annealed specimens, the φ values of lamellae and their origins are controversial owing to the disordered lamellar morphology and orientation. Herein, we report the direct determination of molecular-chain orientations in the lamellar crystals of high-density PE using a state-of-the-art electron-diffraction-based imaging technique with nanometre-scale positional resolution and provide compelling evidence for the existence of lamellar crystals with different inner-chain orientations. Clarifying the nanoscale variation in lamellar crystals in PE can allow precise tuning of properties and expedite resource-saving material design.

9.
Microscopy (Oxf) ; 72(4): 361-367, 2023 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-36495192

RESUMO

The mechanisms of electron irradiation damage to epoxy resin samples were evaluated using their electron diffraction patterns and electron energy-loss spectra. Their electron diffraction patterns consisted of three indistinct halo rings. The halo ring corresponding to an intermolecular distance of ∼6.4 Šdegraded rapidly. Such molecular-scale collapse could have been caused by cross-linking between molecular chains. The degree of electron irradiation damage to the samples changed with the accelerating voltage. The tolerance dose limit of the epoxy resin estimated from the intensity of the halo ring was found to be improved at a higher accelerating voltage. Changes in low-loss electron energy-loss spectra indicated that the mass loss of the epoxy resin was remarkable in the early stage of electron irradiation.

10.
J Phys Chem Lett ; 14(20): 4858-4865, 2023 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-37199249

RESUMO

The core-loss spectrum reflects the partial density of states (PDOS) of the unoccupied states at the excited state and is a powerful analytical technique to investigate local atomic and electronic structures of materials. However, various molecular properties governed by the ground-state electronic structure of the occupied orbital cannot be directly obtained from the core-loss spectra. Here, we constructed a machine learning model to predict the ground-state carbon s- and p-orbital PDOS in both occupied and unoccupied states from the C K-edge spectra. We also attempted an extrapolation prediction of the PDOS of larger molecules using a model trained by smaller molecules and found that the extrapolation prediction performance can be improved by excluding tiny molecules. Besides, we found that using smoothing preprocess and training by specific noise data can improve the PDOS prediction for noise-contained spectra, which pave a way for the application of the prediction model to the experimental data.

11.
J Atheroscler Thromb ; 28(9): 954-962, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33100279

RESUMO

AIM: The predictors of restenosis after endovascular therapy (EVT) with paclitaxel drug-coated balloons (DCBs) have not been clearly established. The present study aimed to investigate the association of post-procedural dissection, as evaluated using intravascular ultrasound (IVUS), with the risk of restenosis following femoropopliteal EVT with paclitaxel DCBs. METHODS: In the present single-center retrospective study, 60 de novo femoropopliteal lesions (44 patients) that underwent EVT with DCBs, without bail-out stenting, were enrolled. The primary outcome was 1-year primary patency. Risk factors for restenosis were evaluated using a Cox proportional hazards regression model and random survival forest analysis. RESULTS: The 1-year primary patency rate was 57.2% [95% confidence interval, 45%-72%]. IVUS-evaluated post-procedural dissection was significantly associated with the risk of restenosis (P=0.002), with the best cutoff point of 64º [range, 39º-83º]. The random survival forest analysis showed that the variable importance measure of IVUS-evaluated dissection was significantly lower than that of the reference vessel diameter (P<0.001), not different from that of the lesion length (P=0.41), and significantly higher than that of any other clinical feature (all P<0.05). CONCLUSION: IVUS-evaluated post-procedural dissection was associated with 1-year restenosis following femoropopliteal EVT with DCB.


Assuntos
Procedimentos Endovasculares , Paclitaxel/uso terapêutico , Doença Arterial Periférica/terapia , Moduladores de Tubulina/uso terapêutico , Dispositivos de Acesso Vascular , Idoso , Idoso de 80 Anos ou mais , Constrição Patológica/diagnóstico , Constrição Patológica/etiologia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Paclitaxel/administração & dosagem , Doença Arterial Periférica/diagnóstico , Prognóstico , Estudos Retrospectivos , Resultado do Tratamento , Moduladores de Tubulina/administração & dosagem , Dispositivos de Acesso Vascular/efeitos adversos
12.
RSC Adv ; 9(19): 10520-10527, 2019 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-35515318

RESUMO

Ionic liquids show characteristic properties derived from them being composed of only molecular ions, and have recently been used as solvents for chemical reactions and as electrolytes for electrochemical devices. The liquid structures, i.e., ionic distributions, form when solutes are dissolved in ionic liquids and fundamentally affect the reactions and transfer efficiency in such solutions. In this study, we directly observe the liquid structure in a solution of the long-chain ionic liquid 1-octyl-3-methylimidazolium bromide (C8mim Br) and barium stearate (Ba(C17H35COO)2) using the annular dark-field method of scanning transmission electron microscopy (ADF-STEM). The ADF image shows a 10 nm-scale heterogeneity in the image intensity, which reflects the heterogeneous ionic distribution in the solution. The number density distributions of all the component ions (C8mim+, Br-, Ba2+, and C17H35COO-) were estimated from the ADF image intensity and then visualized. These ionic distribution maps depicted the spatial relationships between the ions at the sub-nanometer scale and revealed that the heterogeneity is largely derived from the large differences in size, charge distributions, and van der Waals interactions.

13.
Heart Rhythm ; 16(1): 128-139, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30075279

RESUMO

BACKGROUND: Air embolisms are serious complications during catheter ablation procedures. OBJECTIVES: The aims of the present study were to determine when air bubbles enter the left atrium (LA) during catheter ablation procedures and to identify techniques that reduce air bubble intrusion. METHODS: An ex vivo study was performed to monitor air bubbles using a silicone heart model and a high-resolution camera. In total, 280 radiofrequency catheter and cryoballoon ablation processes were tested. RESULTS: Small and large air bubbles were often observed during catheter ablation processes. Many small air bubbles arose during sheath flushing at fast speeds (15 mL/2 s) (median bubble number [quartiles]: 35 [20-53] for SL0, 35 [23-44] for Agilis, and 98 [91-100] for FlexCath) and during initial cryoballoon inflation/freezing/deflation (34 [22-47]). Large (≥1.5 mm) air bubbles were observed during Lasso catheter insertion (1 [0-1]), cryoballoon insertion (2 [1-2]), and initial inflation/freezing/deflation (1 [1-3]). Massive air bubbles were observed during Optima catheter insertion into the sheath using an inserter (10 [2-15]). Sheath flushing at slow speeds (15 mL/5 s) significantly reduced the number of air bubbles. Before cryoballoon insertion, temporary balloon inflation and air bubble removal from the inflated surface were most effective in reducing air bubble intrusions. Optima catheter insertion without an inserter significantly reduced large air bubble intrusion. CONCLUSION: Air bubbles entered the LA at specific times. Techniques such as sheath flushing at slow speeds, temporary cryoballoon inflation before insertion, inserting the Optima catheter without an inserter, and avoidance of negative pressure in the LA could reduce air bubble intrusion.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/métodos , Gravação em Vídeo/instrumentação , Ar , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Desenho de Equipamento , Átrios do Coração , Sistema de Condução Cardíaco/cirurgia , Humanos , Resultado do Tratamento
14.
Microscopy (Oxf) ; 67(suppl_1): i162-i167, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29190375

RESUMO

Understanding structures and spatial distributions of molecules in liquid phases is crucial for the control of liquid properties and to develop efficient liquid-phase processes. Here, real-space mapping of molecular distributions in a liquid was performed. Specifically, the ionic liquid 1-Ethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide (C2mimTFSI) was imaged using atomic-resolution scanning transmission electron microscopy. Simulations revealed network-like bright regions in the images that were attributed to the TFSI- anion, with minimal contributions from the C2mim+ cation. Simple visualization of the TFSI- distribution in the liquid sample was achieved by binarizing the experimental image.

15.
Sci Rep ; 8(1): 13548, 2018 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-30190483

RESUMO

Spectroscopy is indispensable for determining atomic configurations, chemical bondings, and vibrational behaviours, which are crucial information for materials development. Despite their importance, the interpretation of spectra using "human-driven" methods, such as the manual comparison of experimental spectra with reference/simulated spectra, is difficult due to the explosive increase in the number of experimental spectra to be observed. To overcome the limitations of the "human-driven" approach, we develop a new "data-driven" approach based on machine learning techniques by combining the layer clustering and decision tree methods. The proposed method is applied to the 46 oxygen-K edges of the ELNES/XANES spectra of oxide compounds. With this method, the spectra can be interpreted in accordance with the material information. Furthermore, we demonstrate that our method can predict spectral features from the material information. Our approach has the potential to provide information about a material that cannot be determined manually as well as predict a plausible spectrum from the geometric information alone.


Assuntos
Elétrons , Modelos Teóricos , Oxigênio/química , Análise Espectral/métodos
16.
Ultramicroscopy ; 178: 81-87, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27793468

RESUMO

Investigation of the local structure, ionic and molecular behavior, and chemical reactions at high spatial resolutions in liquids has become increasingly important. Improvements in these areas help to develop efficient batteries and improve organic syntheses. Transmission electron microscopy (TEM) and scanning-TEM (STEM) have excellent spatial resolution, and the electron energy-loss near edge structure (ELNES) measured by the accompanied electron energy-loss spectroscopy (EELS) is effective to analyze the liquid local structure owing to reflecting the electronic density of states. In this study, we fabricate a liquid-layer-only sample with thickness of single to tens nanometers using an ionic liquid. Because the liquid film has a thickness much less than the inelastic mean free path (IMFP) of the electron beam, the fine structure of the C-K edge electron energy loss near edge structure (ELNES) can be measured with sufficient resolution to allow meaningful analysis. The ELNES spectrum from the thin liquid film has been interpreted using first principles ELNES calculations.

17.
Sci Adv ; 3(12): e1701546, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29250598

RESUMO

Investigation of the local dynamic behavior of atoms and molecules in liquids is crucial for revealing the origin of macroscopic liquid properties. Therefore, direct imaging of single atoms to understand their motions in liquids is desirable. Ionic liquids have been studied for various applications, in which they are used as electrolytes or solvents. However, atomic-scale diffusion and relaxation processes in ionic liquids have never been observed experimentally. We directly observe the motion of individual monatomic ions in an ionic liquid using scanning transmission electron microscopy (STEM) and reveal that the ions diffuse by a cage-jump mechanism. Moreover, we estimate the diffusion coefficient and activation energy for the diffusive jumps from the STEM images, which connect the atomic-scale dynamics to macroscopic liquid properties. Our method is the only available means to observe the motion, reactions, and energy barriers of atoms/molecules in liquids.

18.
Ultramicroscopy ; 178: 88-95, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27477916

RESUMO

The effect of the van der Waals (vdW) interaction on the simulation of the electron energy-loss near edge structure (ELNES) by a first-principles band-structure calculation is reported. The effect of the vdW interaction is considered by the Tkatchenko-Scheffler scheme, and the change of the spectrum profile and the energy shift are discussed. We perform calculations on systems in the solid, liquid and gaseous states. The transition energy shifts to lower energy by approximately 0.1eV in the condensed (solid and liquid) systems by introducing the vdW effect into the calculation, whereas the energy shift in the gaseous models is negligible owing to the long intermolecular distance. We reveal that the vdW interaction exhibits a larger effect on the excited state than the ground state owing to the presence of an excited electron in the unoccupied band. Moreover, the vdW effect is found to depend on the local electron density and the molecular coordination. In addition, this study suggests that the detection of the vdW interactions exhibited within materials is possible by a very stable and high resolution observation.

19.
Ultramicroscopy ; 178: 105-111, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27106633

RESUMO

Excitonic interactions of the oxygen K-edge electron energy-loss near-edge structure (ELNES) of perovskite oxides, CaTiO3, SrTiO3, and BaTiO3, together with reference oxides, MgO, CaO, SrO, BaO, and TiO2, were investigated using a first-principles Bethe-Salpeter equation calculation. Although the transition energy of oxygen K-edge is high, strong excitonic interactions were present in the oxygen K-edge ELNES of the perovskite oxides, whereas the excitonic interactions were negligible in the oxygen K-edge ELNES of the reference compounds. Detailed investigation of the electronic structure suggests that the strong excitonic interaction in the oxygen K-edge ELNES of the perovskite oxides is caused by the directionally confined, low-dimensional electronic structure at the Ti-O-Ti bonds.

20.
Sci Rep ; 7(1): 16434, 2017 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-29234014

RESUMO

Reactions in gaseous phases and at gas/solid interfaces are widely used in industry. Understanding of the reaction mechanism, namely where, when, and how these gaseous reactions proceed, is crucial for the development of further efficient reaction systems. To achieve such an understanding, it is indispensable to grasp the dynamic behavior of the gaseous molecules at the active site of the chemical reaction. However, estimation of the dynamic behavior of gaseous molecules in specific nanometer-scale regions is always accompanied by great difficulties. Here, we propose a method for the identification of the dynamic behavior of gaseous molecules using an electron spectroscopy observed with a transmission electron microscope in combination with theoretical calculations. We found that our method can successfully identify the dynamic behavior of some gaseous molecules, such as O2 and CH4, and the sensitivity of the method is affected by the rigidity of the molecule. The method has potential to measure the local temperature of gaseous molecules as well. The knowledge obtained from this technique is fundamental for further high resolution studies of gaseous reactions using electron microscopy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA