Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Anal Chem ; 95(32): 12113-12121, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37545056

RESUMO

The global prevalence of ß-lactam allergy poses a major challenge in administering first-line antibiotics, such as penicillins, to a significant portion of the population. The lack of ß-lactam IgE antibody pools with defined selectivity hampers the standardization and validation of in vitro assays for ß-lactam allergy testing. To address this limitation, this study introduces a synthetic IgE specific to ß-lactam antibiotics as a valuable tool for drug allergy research and diagnostic tests. Using phage display technology, we constructed a library of human single-chain antibody fragments (scFv) to target the primary determinant of amoxicillin, a widely used ß-lactam antibiotic. Subsequently, we produced a complete human synthetic IgE molecule using the highly efficient baculovirus expression vector system. This synthetic IgE molecule served as a standard in an in vitro chemiluminescence immunoassay for ß-lactam antibiotic allergy testing. Our results demonstrated a detection limit of 0.05 IU/mL (0.63 pM), excellent specificity (100%), and a four-fold higher clinical sensitivity (73%) compared to the in vitro reference assay when testing a cohort of 150 serum samples. These findings have significant implications for reliable interlaboratory comparison studies, accurate labeling of allergic patients, and combating the global public health threat of antimicrobial resistance. Furthermore, by serving as a valuable trueness control material, the synthetic IgE facilitates the standardization of diagnostic tests for ß-lactam allergy and demonstrates the potential of utilizing this synthetic strategy as a promising approach for generating reference materials in drug allergy research and diagnostics.


Assuntos
Hipersensibilidade a Drogas , Hipersensibilidade , Humanos , Testes Cutâneos , Antibacterianos , beta-Lactamas , Penicilinas , Hipersensibilidade a Drogas/diagnóstico , Hipersensibilidade a Drogas/epidemiologia , Monobactamas , Antibióticos beta Lactam , Imunoglobulina E
2.
Mikrochim Acta ; 190(5): 166, 2023 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-37010667

RESUMO

A high percentage of the population suffers from multiple food allergies justifying  the importance of reliable diagnostic methods. Single-analyte solutions based on the determination of specific immunoglobulins E (sIgE) are safe and fast but are generally time-consuming and expensive. Thus sustainable microanalytical methods that provide multianalyte profiling information are highly demanded. This work presents the in vitro biosensing of specific IgE levels based on a reversed-phase allergen array. The approach consists of optical biosensing supported by direct multiplex immunoassays and on-disc technology. It identifies 12 sIgE associated with food allergies in a single analysis with a low serum sample volume (25 µL). After processing captured images, specific signals for each target biomarker correlate to their concentration. The assay analytically performs well with 0.3 IU/mL and 0.41 IU/mL as the detection and quantification limits in serum, respectively. This novel method achieves excellent clinical specificity (100%) and high sensitivity (91.1%), considering the diagnosis obtained by clinical history and ImmunoCAP analysis. The results demonstrate that microanalytical systems based on allergen arrays can potentially diagnose multiple food allergies and are easily implemented in primary care laboratory settings.


Assuntos
Alérgenos , Hipersensibilidade Alimentar , Humanos , Hipersensibilidade Alimentar/diagnóstico , Imunoensaio/métodos , Análise em Microsséries , Imunoglobulina E
3.
Anal Chem ; 94(2): 1342-1349, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-34931798

RESUMO

Commonly, serological immunoassays and diagnostic kits include reference standard reagents (calibrators) that contain specific antibodies to be measured, which are used for the quantification of unknown antibodies present in the sample. However, in some cases, such as the diagnosis of allergies or autoimmune diseases, it is often difficult to have sufficient quantities of these reference standards, and there are limitations to their lot-to-lot reproducibility and standardization over time. To overcome this difficulty, this study introduces the use of surrogate recombinant calibrators formulated on the basis of two single-domain antibodies (nanobodies) combined through a short peptide linker to produce a recombinant bispecific construct. One of the nanobodies binds to the cognate analyte of the target antibody and the second is specific for the paratope of the secondary detecting antibody. The bispecific nanobody inherits the outstanding properties of stability and low-cost production by bacterial fermentation of the parent nanobodies, and once calibrated against the biological reference standard, it can be reproduced indefinitely from its sequence in a highly standardized manner. As a proof of concept, we present the generation and characterization of two bispecific calibrators with potential application for the diagnosis of allergy against the antibiotics aztreonam and amoxicillin in humans.


Assuntos
Anticorpos Biespecíficos , Anticorpos de Domínio Único , Anticorpos , Anticorpos Biespecíficos/química , Humanos , Imunoensaio , Testes Imunológicos , Reprodutibilidade dos Testes
4.
Anal Chem ; 92(21): 14608-14615, 2020 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-33089686

RESUMO

ß-lactams (BLCs) are the most widely used antibiotics and consequently the most common cause of drug allergy in the world. The diagnosis of drug allergy is complex and represents a serious challenge that includes a wide variety of methods. In vitro tests are based on the immunological determination of allergen-specific IgE, but the tests in the market lack the required sensitivity and specificity. In addition, the large sample volume, long incubation times, and single-plex configuration have brought their use into question to complement the clinical information. Here, we report a chemiluminescence immunoassay (CLIA) for multiparametric quantification of specific IgE to penicillin G, penicillin V, amoxicillin, and piperacillin, using histone H1 as a carrier. The developed CLIA allowed the determination of BLC-specific IgE below 0.1 IU/mL, thus allowing identification of allergic patients with better sensitivity, using only 25 µL of a sample (serum). The immunoassay was successfully applied in a cohort of 140 human serum samples, showing good sensitivity (64.6%) as well as specificity (100%), which significantly improve the predictive character of existing BLC-allergy in vitro tests.


Assuntos
Especificidade de Anticorpos , Imunoensaio/métodos , Imunoglobulina E/análise , Limite de Detecção , Luminescência , beta-Lactamas/imunologia , Humanos , Imunoglobulina E/sangue , Imunoglobulina E/imunologia
5.
Anal Bioanal Chem ; 411(19): 4709-4720, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30317445

RESUMO

The mechanism of self-recognition of the autoantigen TROVE2, a common biomarker in autoimmune diseases, has been studied with a quartz crystal microbalance with dissipation monitoring (QCM-D) and dual polarization interferometry (DPI). The complementarity and remarkable analytical features of both techniques has allowed new insights into the onset of systemic lupus erythematosus (SLE) to be achieved at the molecular level. The in vitro study for SLE patients and healthy subjects suggests that anti-TROVE2 autoantibodies may undergo an antibody bipolar bridging. An epitope-paratope-specific binding initially occurs to activate a hidden Fc receptor in the TROVE2 tertiary structure. This bipolar mechanism may contribute to the pathogenic accumulation of anti-TROVE2 autoantibody immune complex in autoimmune disease. Furthermore, the specific calcium-dependent protein-protein bridges point out at how the TRIM21/TROVE2 association might occur, suggesting that the TROVE2 protein could stimulate the intracellular immune signaling via the TRIM21 PRY-SPRY domain. These findings may help to better understand the origins of the specificity and affinity of TROVE2 interactions, which might play a key role in the SLE pathogenesis. This manuscript gives one of the first practical applications of two novel functions (-df/dD and Δh/molec) for the analysis of the data provided by QCM-D and DPI. In addition, it is the first time that QCM-D has been used for mapping hidden Fc receptors as well as linear epitopes in a protein tertiary structure. Graphical abstract ᅟ.


Assuntos
Autoantígenos/fisiologia , Interferometria/métodos , Lúpus Eritematoso Sistêmico/imunologia , Técnicas de Microbalança de Cristal de Quartzo , RNA Citoplasmático Pequeno/fisiologia , Ribonucleoproteínas/fisiologia , Autoanticorpos/imunologia , Autoantígenos/química , Autoantígenos/imunologia , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Conformação Proteica , RNA Citoplasmático Pequeno/química , RNA Citoplasmático Pequeno/imunologia , Ribonucleoproteínas/química , Ribonucleoproteínas/imunologia
6.
Anal Bioanal Chem ; 409(9): 2261-2268, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28078412

RESUMO

A multiplex competitive microimmunoassay for the simultaneous determination of gliadin, casein, ß-lactoglobulin, and ovalbumin is presented. The assay in microarray format is performed on a DVD where the allergens are physisorbed on the polycarbonate surface of the disc. The immunointeraction is detected using a mixture of specific gold-labeled antibodies and the signal amplified with the silver enhancement method. The optical density of the precipitate, read by a DVD drive, is related to the concentration of the four allergens in sample. An optimized protocol for the simultaneous extraction of the allergen proteins from food samples is also addressed. The suitability of the method is demonstrated for the simultaneous quantitative extraction and determination of the targeted allergens in spiked baby foods, juices, and beers. The sensitivity (EC50) of the multiplexed assay was 0.04, 0.40, 0.08, and 0.16 mg L-1 for gliadin, casein, ß-lactoglobulin, and ovalbumin, respectively, and the recovery results from the analysis of food samples ranged from 72 to 117%. A portable, easy-to-use, array-based bioanalytical method is developed for quantification of food allergens with a limit of detection below the accepted levels of the international legislations, which allows promotion of food safety and quality. Graphical abstract GLI Gliadin, CAS Casein, ß-LAC ß-lactoglobulin, OVA Ovalbumin.


Assuntos
Alérgenos/análise , Hipersensibilidade Alimentar/etiologia , Imunoensaio/métodos , Limite de Detecção
7.
Anal Bioanal Chem ; 408(17): 4523-34, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26922341

RESUMO

The idea of using disk drives to monitor molecular biorecognition events on regular optical discs has received considerable attention during the last decade. CDs, DVDs, Blu-ray discs and other new optical discs are universal and versatile supports with the potential for development of protein and DNA microarrays. Besides, standard disk drives incorporated in personal computers can be used as compact and affordable optical reading devices. Consequently, a CD technology, resulting from the audio-video industry, has been used to develop analytical applications in health care, environmental monitoring, food safety and quality assurance. The review presents and critically evaluates the current state of the art of disc-based microarrays with illustrative examples, including past, current and future developments. Special mention is made of the analytical developments that use either chemically activated or raw standard CDs where proteins, oligonucleotides, peptides, haptens or other biological probes are immobilized. The discs are also used to perform the assays and must maintain their readability with standard optical drives. The concept and principle of evolving disc-based microarrays and the evolution of disk drives as optical detectors are also described. The review concludes with the most relevant uses ordered chronologically to provide an overview of the progress of CD technology applications in the life sciences. Also, it provides a selection of important references to the current literature. Graphical Abstract High density disc-based microarrays.


Assuntos
Análise de Sequência com Séries de Oligonucleotídeos , Dispositivos Ópticos , Análise Serial de Proteínas
8.
Anal Chem ; 87(19): 9817-24, 2015 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-26390221

RESUMO

An immuno multiresidue screening assay in microarray format for the determination of complex chemical mixtures at the microgram per liter level, using antibody-functionalized gold nanoparticles, is presented. The analytical method relies on the use of a cocktail of nanogold-labeled specific antibodies, acting as recognition and detection species. The concept of multireside screening is proved by developing a multiplex assay on a compact disk support for the determination of 2-(2,4,5-trichlorophenoxy)propionic acid, 3-phenoxybenozic acid, 4-nitrophenol, alachlor, atrazine, azoxystrobin, chlorpyrifos, diazinon, diuron, endosulfan, fenthion, forchlorfenuron, imidacloprid, malathion, pentachlorophenol, pyraclostrobin, sulfasalazine, and triclosan, achieving detection limits of 0.07, 0.24, 10.9, 0.21, 0.14, 0.11, 0.11, 102, 0.36, 1.8, 1.7, 0.06, 0.08, 5.8, 1.0, 0.39, 0.003, and 12 µg/L, respectively. Due to the selectivity of the antibody-functionalized nanoparticles, the developed screening methodology allows the simultaneous determination of mixtures of water pollutants in a 10-plex configuration. The analytical performances were compared with those of reference chromatographic methods by the analysis of spiked water samples, the sensitivity and recovery results being in good agreement. The presented screening approach directly quantifies the concentration of complex chemical mixtures without sample treatment or preconcentration steps in a total time of 35 min.


Assuntos
Anticorpos Imobilizados/química , Monitoramento Ambiental/métodos , Imunoensaio/métodos , Nanopartículas/química , Rios/química , Poluentes da Água/análise
9.
Anal Chem ; 86(24): 12037-46, 2014 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-25310278

RESUMO

A new analytical system based on Thermochromic Etching Discs (TED) technology is presented. TED comprises a number of attractive features such as track independency, selective irradiation, a high power laser, and the capability to create useful assay platforms. The analytical versatility of this tool opens up a wide range of possibilities to design new compact disc-based total analysis systems applicable in chemistry and life sciences. In this paper, TED analytical implementation is described and discussed, and their analytical potential is supported by several applications. Microarray immunoassay, immunofiltration assay, solution measurement, and cell culture approaches are herein addressed in order to demonstrate the practical capacity of this system. The analytical usefulness of TED technology is herein demonstrated, describing how to exploit this tool for developing truly integrated analytical systems that provide solutions within the point of care framework.


Assuntos
Bioensaio/instrumentação , Técnicas Biossensoriais , Técnicas de Química Analítica/instrumentação , Técnicas de Química Analítica/métodos , Células Cultivadas , Humanos , Análise em Microsséries , Temperatura
10.
Biosens Bioelectron ; 251: 116131, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38367566

RESUMO

Plant health monitoring is devised as a new concept to elucidate in situ physiological processes. The need for increased food production to nourish the growing global population is inconsistent with the dramatic impact of climate change, which hinders crop health and exacerbates plant stress. In this context, wearable sensors play a crucial role in assessing plant stress. Herein, we present a low-cost 3D-printed hollow microneedle array (HMA) patch as a sampling device coupled with biosensors based on screen-printing technology, leading to affordable analysis of biomarkers in the plant fluid of a leaf. First, a refinement of the 3D-printing method showed a tip diameter of 25.9 ± 3.7 µm with a side hole diameter on the microneedle of 228.2 ± 18.6 µm using an affordable 3D printer (<500 EUR). Notably, the HMA patch withstanded the forces exerted by thumb pressing (i.e. 20-40 N). Subsequently, the holes of the HMA enabled the fluid extraction tested in vitro and in vivo in plant leaves (i.e. 13.5 ± 1.1 µL). A paper-based sampling strategy adapted to the HMA allowed the collection of plant fluid. Finally, integrating the sampling device onto biosensors facilitated the in situ electrochemical analysis of plant health biomarkers (i.e. H2O2, glucose, and pH) and the electrochemical profiling of plants in five plant species. Overall, this electrochemical platform advances precise and versatile sensors for plant health monitoring. The wearable device can potentially improve precision farming practices, addressing the critical need for sustainable and resilient agriculture in changing environmental conditions.


Assuntos
Técnicas Biossensoriais , Dispositivos Eletrônicos Vestíveis , Peróxido de Hidrogênio , Impressão Tridimensional , Biomarcadores
11.
Talanta ; 278: 126511, 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38986307

RESUMO

The application of advances in personalized medicine requires the support of in vitro diagnostic techniques aimed at the accurate, fast, sensitive, and precise determination of selected biomarkers. Herein, a novel optical centrifugal microfluidic device is developed for clinical analysis and point-of-care diagnostics. Based on compact disc technology, the integrated biophotonic system enables multiple immunoassays in miniaturized mode. The disposable microfluidic discs are made in cyclic olefin copolymer (COP), containing arrays of immobilized probes. In the developed approach, up to six patient samples can each be tested simultaneously. A portable instrument (<2 kg) controls the assay and the high-sensitive reproducible optical detection in transmission mode. Also, the instrument incorporates specific functionalities for personalized telemedicine. The device (analytical method, disc platform, reader, and software) has been validated to diagnose IgE-mediated drug allergies, such as amoxicillin and penicillin G. The total and specific IgE to ß-lactam antibiotics were determined in human serum from patients (25 µL). The excellent analytical performances (detection limit 0.24 ng/mL, standard deviation 7-20 %) demonstrated that the developed system could have the potential for a broader impact beyond the allergy field, as it applies to other IVD tests.

12.
Trends Biotechnol ; 41(10): 1299-1313, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37150668

RESUMO

In order to decentralize health care, the development of point-of-care (PoC) assays has gained significant attention in recent decades. The lateral flow immunoassay (LFIA) has emerged as a promising bioanalytical method due to its low cost and single-step detection process. However, its limited sensitivity and inability to detect disease biomarkers at clinically relevant levels have hindered its application for early diagnosis. This review explores the potential of merging different electrokinetic phenomena into paper-based assays to enhance their analytical performance, offering a versatile and affordable approach for PoC testing. The review exposes the challenges faced in integrating electrokinetic phenomena with paper-based biosensing and concludes by discussing the issues that need to be improved to maximize the potential of this technology for early diagnosis.


Assuntos
Técnicas Biossensoriais , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Imunoensaio/métodos , Tecnologia , Técnicas Biossensoriais/métodos
13.
Food Chem ; 404(Pt A): 134570, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36252370

RESUMO

The hypothesis of this study is centered around the logic that an enhanced analysis of potential allergens during the food production can lead to increased accuracy and reliability of food labeling. The development of a cost-effective and straightforward optoelectrical microanalytical system for the simultaneous quantification of the six most common food allergens (peanut, hazelnut, almond, milk, wheat, and soybean) is presented. The system uses a regular versatile disc (DVD) functionalized with highly selective antibodies in a microarray format and a DVD drive as the optical detector. The multiplexed assay reliably (RSD < 20 %) determines the level of the allergenic proteins ranging from 0.1 to 143.4 ng mL-1. The analysis of food consumables (biscuits, seafood substitutes, and probiotic foods) revealed a 100 % accuracy in identifying the allergens ingredients declared on the label. The method offers potential for application as a high throughput biosensing tool for screening multiple allergens in commercial foods.


Assuntos
Corylus , Hipersensibilidade Alimentar , Criança , Humanos , Alérgenos/análise , Reprodutibilidade dos Testes , Arachis
14.
Dalton Trans ; 52(48): 18464-18472, 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38013493

RESUMO

Colloidal lead halide perovskite nanocrystals are highly luminescent materials with great promise as fluorescent probes in biosensing as long as their intrinsic instability in aqueous media is effectively addressed. In this study, we successfully prepared stable and multicolored CsPbX3@SiO2 (X = Cl/Br, Br and I) core-shell nanoparticles through a simple method based on the water-induced transformation of Cs4PbX6 into CsPbX3, combined with sol-gel procedures. We observed that the concentration of the Cs4PbX6 precursor plays a crucial role in the formation of isolated nanospheres with uniform silica coating and in controlling the number of core-free particles. Furthermore, our research expands this approach to other halide compositions, resulting in multicolored core-shell nanoparticles with emission wavelengths ranging from 490 to 700 nm, average sizes below 30 nm, and photoluminescence quantum yields close to 60%. Unlike in previous reports, the silica coating boosts the photoluminescence quantum yields compared to uncoated counterparts and provides increased structural stability for more than four days. Moreover, a controlled thermal treatment confers water stability to the as-synthesized nanoparticles. To establish the feasibility of the developed materials as fluorescent probes, we successfully demonstrated their specific recognition of a humanized antibody (omalizumab) used in treating patients with severe allergic asthma. This work paves the way to develop in vitro tests using CsPbX3@SiO2 core-shell nanoparticles as fluorogenic probes.


Assuntos
Nanosferas , Água , Humanos , Água/química , Corantes Fluorescentes , Dióxido de Silício/química , Luminescência
15.
Biosensors (Basel) ; 12(11)2022 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-36354489

RESUMO

Quality assurance and food safety are of great concern within the food industry because of unknown quantities of allergens often present in food. Therefore, there is an ongoing need to develop rapid, sensitive, and easy to use methods that serve as an alternative to mass spectrometry and enzyme-linked immunosorbent assay (ELISA) for monitoring food safety. Lateral flow immunoassay is one of the most used point-of-need devices for clinical, environmental, and food safety applications. Compared to traditional methods, it appears to be a simple and fast alternative for detecting food allergens. However, its reliability is frequently questioned due to the lack of quantitative information. In this study, a lateral flow microimmunoassay (LFµIA) is presented that integrates up to 36 spots in microarray format in a single strip, providing semi-quantitative information about the level of allergens, positive and negative controls, internal calibration, and hook effect. The LFµIA has been evaluated for the on-site simultaneous and reliable quantification of almond and peanut allergens as a proof of concept, demonstrating high sensitivity (185 and 229 µg/kg, respectively), selectivity (77%), and accuracy (RSD 5-25%) when analyzing commercial allergen-suspicious food consumables.


Assuntos
Alérgenos , Hipersensibilidade Alimentar , Humanos , Alérgenos/análise , Reprodutibilidade dos Testes , Alimentos , Imunoensaio/métodos , Ensaio de Imunoadsorção Enzimática/métodos
16.
Chem Commun (Camb) ; 58(40): 5964-5967, 2022 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-35475490

RESUMO

We present the first synthesis of ß-lactam-derived haptens, leveraging the principles of diversity-oriented synthesis to discover compounds for drug allergy in vitro testing. We designed, synthesised, and performed in vitro immunological evaluation on 18 structurally diverse haptens derived from ß-lactam antibiotics. The antigens obtained with the synthesised haptens allow for the detection of specific anti-ß-lactam immunoglobulins G and E. Excellent diagnostic sensitivity (83%) and specificity (100%) were achieved when the panel of antigens was tested against a cohort of 31 human serum samples using a multiplexed compact disc-based in vitro testing tool. We posit that adopting this strategy could aid ß-lactam delabeling initiatives.


Assuntos
Hipersensibilidade a Drogas , beta-Lactamas , Antibacterianos/farmacologia , Estudos de Coortes , Hipersensibilidade a Drogas/diagnóstico , Haptenos , Humanos , Imunoglobulina E
17.
Anal Chim Acta ; 1214: 339940, 2022 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-35649639

RESUMO

Penicillin is one of the most widely used antibiotics to treat bacterial infections in clinical practice. The antibiotic undergoes degradation under physiological conditions to produce reactive compounds that in vivo bind self-proteins. These conjugates might elicit an immune response and trigger allergic reactions challenging to diagnose due to the complex immunogenicity. Penicillin allergy delabeling initiatives are now part of antibiotic stewardship programs and include the use of invasive and risky in vivo tests. Instead, the in vitro quantification of specific IgE is highly useful to confirm immediate allergy to penicillins. However, discrepant results associated with the low sensitivity and accuracy of penicillin allergy in vitro tests have limited their routine diagnostic use for delabeling purposes. We aimed to develop a homologous chemiluminescence-based immunochemical method for the reliable determination of specific IgE to penicillin G, using unprecedented synthetic human-like standards. The synthetic standard targets the major antigenic determinant of penicillin G and the paratope of Omalizumab, acting as human-like specific IgE. It is a potent calibrator, highly stable, easy, and inexpensive to produce, overcoming the limitations of the pooled human serum preparations. The developed method achieved a good agreement and strong positive relationship, reaching a detection limit below 0.1 IU mL-1 and excellent reproducibility (RSD <9%). The clinical sensitivity of the assay significantly increased (66%), doubling the accuracy of the reference method with an overall specificity of 100%. The new diagnostic strategy compares favorably with results obtained by the standard procedure, paving the way towards the standardization of penicillin allergy testing, and enhancing the detection sensitivity of specific IgE in serum to tackle reliably ß-lactam allergy delabeling.


Assuntos
Hipersensibilidade a Drogas , Luminescência , Antibacterianos , Hipersensibilidade a Drogas/diagnóstico , Hipersensibilidade a Drogas/tratamento farmacológico , Humanos , Imunoensaio , Imunoglobulina E , Penicilinas , Reprodutibilidade dos Testes
18.
Biosens Bioelectron ; 213: 114454, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-35696866

RESUMO

The impact of the COVID-19 pandemic has reinforced the need for rapid, cost-effective, and reliable point-of-care testing (POCT) devices for massive population screening. The co-circulation of SARS-CoV-2 with several seasonal respiratory viruses highlights the need for multiplexed biosensing approaches. Herein, we present a fast and robust all-in-one POCT device for parallel viral antigen and serological analysis. The biosensing approach consists of a functionalized polycarbonate disc-shaped surface with microfluidic structures, where specific bioreagents are immobilized in microarray format, and a portable optoelectronic analyzer. The biosensor quantifies the concentration of viral antigens and specific immunoglobulins G and M for SARS-CoV-2, influenza A/B, adenovirus, and respiratory syncytial virus, using 30 µL of a sample. The semi-automated analysis of 6 samples is performed in 30 min. Validation studies performed with 135 serum samples and 147 nasopharyngeal specimens reveal high diagnostic sensitivity (98-100%) and specificity (84-98%), achieving an excellent agreement (κ = 0.937) with commercial immunoassays, which complies with the World Health Organization criteria for POC COVID-19 diagnostic tests. The versatility of the POCT device paves the way for the detection of other pathogens and analytes in the incoming post-pandemic world, integrating specific bioreagents against different variants of concerns and interests.


Assuntos
Técnicas Biossensoriais , COVID-19 , Influenza Humana , Infecções Respiratórias , Antígenos Virais/análise , COVID-19/diagnóstico , Humanos , Influenza Humana/diagnóstico , Pandemias , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Infecções Respiratórias/diagnóstico , SARS-CoV-2 , Sensibilidade e Especificidade
19.
Bioconjug Chem ; 22(12): 2573-80, 2011 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-22044406

RESUMO

A novel DNA microarrying platform based on oxygen plasma activation of polycarbonate surface of compact disks (DVD) is presented. Carboxylic acid groups are generated in few seconds on polycarbonate in an efficient, fast, and clean way. Following this surface activation strategy, amino-modified oligonucleotide probes were covalently attached, reaching an immobilization density of 2 pmol cm(-2). Atomic force microscopy imaging revealed the nondestructive character of this treatment when applied for short times, allowing for disk scanning in standard DVD drives. DNA assays performed on oxygen plasma treated disks resulted very efficient with maximum hybridization yield of 93% and reaching a low limit of detection (200 pM) for perfect match synthetic oligonucleotide targets when reading the disk with a standard drive as detector. The approach was also evaluated by scoring single nucleotide polymorphisms with a discrimination ratio of 12.8. As proof of concept, the oxygen plasma treated interactive polycarbonate DNA microarraying platform was applied to the detection of PCR products of Salmonella spp., reaching a detection limit of 2 nM that corresponds to a DNA concentration of only 1 c.f.u./mL. The results confirm the suitability of the microarray platform for analysis of biological samples with high sensitivity.


Assuntos
DNA Bacteriano/genética , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Oxigênio/química , Cimento de Policarboxilato/química , Salmonella/genética , Desenho de Equipamento , Limite de Detecção , Reação em Cadeia da Polimerase , Propriedades de Superfície
20.
Anal Chim Acta ; 1173: 338656, 2021 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-34172156

RESUMO

The suspicion of beta-lactam allergy directly contributes to the prescription of antibiotics that diverge from the guidelines, increasing antimicrobial resistance, one of the biggest threats to global health. In vitro quantification of specific IgE is very useful for monitoring allergy, as it confirms or rules out immediate beta-lactam drug allergy and helps find safe alternative antibiotic stewardship. However, reliable in vitro quantification of specific IgE to beta-lactam antibiotics by immunoassay is challenging because of the difficulty of having selective immunoreagents, mainly beta-lactam antigens, and its low concentration levels in serum. Thus, reliable and sensitive in vitro tests for multiplex detection of allergy to different beta-lactam antibiotics is currently essential for clinical diagnosis. Nevertheless, the lack of standardization of quantitative in vitro methods makes the comparison and interpretation of the results difficult. Here, as proof of concept, we report an improved multiplex microimmunoassay for beta-lactam allergy in vitro testing standardization. The results revealed that homologous calibration allows reliable quantification of specific IgE in human serum at very low concentrations (144 ng L-1). Moreover, the reproducibility of the results increases 2-fold using an internal standard, achieving accurate quantitative information: 93% and 106% recovery for penicillin and amoxicillin, respectively. We simultaneously evaluated the reliability of the improved multiplexed in vitro method in a cohort of 40 human serum samples and achieved excellent agreement (0.99) with a currently used in vitro test.


Assuntos
Hipersensibilidade a Drogas , beta-Lactamas , Antibacterianos , Hipersensibilidade a Drogas/diagnóstico , Humanos , Técnicas In Vitro , Padrões de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA