Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Alzheimer Dis Assoc Disord ; 38(2): 160-167, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38748658

RESUMO

INTRODUCTION: Enrolling individuals from underrepresented ethnoracial groups in aging research is often a challenge. METHODS: We sought a diverse sample of older adults from a small-town area for a longitudinal aging study. We employed an intensive community engagement approach encompassing a range of recruitment strategies. RESULTS: Over 4 years a steady trickle of individuals, 66% self-identifying as Black, signed up for study information; the proportion of those who eventually enroll in the study has been rising each year, from 68% to 94%. Community events, word-of-mouth referrals, and mailed postcards brought in the most contacts. The highest percentage of contacts who ultimately enrolled were from postcards, flyers, and word-of-mouth. Significantly more word-of-mouth referrals were endorsed by Black individuals than White and by Black men than other race/sex groups. CONCLUSIONS: We have had some success in building relationships and trust with the local community, enrolling Black study participants in a proportion equal to their representation in the target community using a variety of recruitment methods. Patience, immersion in the community, and partnerships with key community members alongside traditional advertisements, and the utilization of study participants as recruiters are critical to designing optimal, targeted, recruitment strategies.


Assuntos
Envelhecimento , Seleção de Pacientes , Humanos , Estudos Longitudinais , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes
2.
J Stroke Cerebrovasc Dis ; 33(6): 107700, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38570060

RESUMO

OBJECTIVES: With the rising global burden of stroke-related morbidity, and increased focus on patient-centered healthcare, patient reported outcome measures (PROMs) are increasingly used to inform healthcare decision-making. Some stroke patients with cognitive or motor impairments are unable to respond to PROMs, so proxies may respond on their behalf; the reliability of which remains unclear. The aim of the study is to update a 2010 systematic review to investigate the inter-rater reliability of proxy respondents answering PROMs for stroke patients. MATERIALS AND METHODS: Studies on the reliability of proxy respondents in stroke were searched within CINAHL, Embase, PsycInfo, and WoS databases (01/07/22, 08/07/22). Fifteen studies were included for review. ICC and k-statistic were extracted for PROMs scales and categorized as poor (0.80). Bias was assessed using the CCAT. RESULTS: Five studies reported PROMs with inter-rater reliability scores ranging from 0.80. Two studies reported activities of daily living (ADLs) scores ranging from 0.41 to 0.80 and 8 studies reported quality of life (QoL) measures with scores ranging from 0.80. Subcategories of these scales included physical (ICC/k-statistic 0.41- >0.8), cognitive (ICC/k-statistic 0.40-0.80), communication (ICC/k-statistic <0.4-0.80,) and psychological (ICC/k-statistic <0.40-0.60) measures. CONCLUSIONS: Proxy respondents are reliable sources for PROM reports on physical domains in ADLs, PROMs and QoL scales. Proxy reports for measures of communication and psychological domains had greater variability in reliability scores, ranging from poor to substantial; hence, caution should be applied when interpreting proxy reports for these domains.


Assuntos
Atividades Cotidianas , Medidas de Resultados Relatados pelo Paciente , Procurador , Acidente Vascular Cerebral , Humanos , Avaliação da Deficiência , Variações Dependentes do Observador , Valor Preditivo dos Testes , Qualidade de Vida , Reprodutibilidade dos Testes , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/terapia , Acidente Vascular Cerebral/psicologia , Acidente Vascular Cerebral/fisiopatologia , Resultado do Tratamento
3.
Magn Reson Med ; 89(2): 577-593, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36161727

RESUMO

PURPOSE: To develop and validate a method for B 0 $$ {B}_0 $$ mapping for knee imaging using the quantitative Double-Echo in Steady-State (qDESS) exploiting the phase difference ( Δ Î¸ $$ \Delta \theta $$ ) between the two echoes acquired. Contrary to a two-gradient-echo (2-GRE) method, Δ Î¸ $$ \Delta \theta $$ depends only on the first echo time. METHODS: Bloch simulations were applied to investigate robustness to noise of the proposed methodology and all imaging studies were validated with phantoms and in vivo simultaneous bilateral knee acquisitions. Two phantoms and five healthy subjects were scanned using qDESS, water saturation shift referencing (WASSR), and multi-GRE sequences. Δ B 0 $$ \Delta {B}_0 $$ maps were calculated with the qDESS and the 2-GRE methods and compared against those obtained with WASSR. The comparison was quantitatively assessed exploiting pixel-wise difference maps, Bland-Altman (BA) analysis, and Lin's concordance coefficient ( ρ c $$ {\rho}_c $$ ). For in vivo subjects, the comparison was assessed in cartilage using average values in six subregions. RESULTS: The proposed method for measuring Δ B 0 $$ \Delta {B}_0 $$ inhomogeneities from a qDESS acquisition provided Δ B 0 $$ \Delta {B}_0 $$ maps that were in good agreement with those obtained using WASSR. Δ B 0 $$ \Delta {B}_0 $$ ρ c $$ {\rho}_c $$ values were ≥ $$ \ge $$ 0.98 and 0.90 in phantoms and in vivo, respectively. The agreement between qDESS and WASSR was comparable to that of a 2-GRE method. CONCLUSION: The proposed method may allow B0 correction for qDESS T 2 $$ {T}_2 $$ mapping using an inherently co-registered Δ B 0 $$ \Delta {B}_0 $$ map without requiring an additional B0 measurement sequence. More generally, the method may help shorten knee imaging protocols that require an auxiliary Δ B 0 $$ \Delta {B}_0 $$ map by exploiting a qDESS acquisition that also provides T 2 $$ {T}_2 $$ measurements and high-quality morphological imaging.


Assuntos
Joelho , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Joelho/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Água
4.
J Magn Reson Imaging ; 58(3): 951-962, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36583628

RESUMO

BACKGROUND: Diffusion-weighted imaging (DWI) may allow for breast cancer screening MRI without a contrast injection. Multishot methods improve prone DWI of the breasts but face different challenges in the supine position. PURPOSE: To establish a multishot DWI (msDWI) protocol for supine breast MRI and to evaluate the performance of supine vs. prone msDWI. STUDY TYPE: Prospective. POPULATION: Protocol optimization: 10 healthy women (ages 22-56), supine vs. prone: 24 healthy women (ages 22-62) and five women (ages 29-61) with breast tumors. FIELD STRENGTH/SEQUENCE: 3-T, protocol optimization msDWI: free-breathing (FB) 2-shots, FB 4-shots, respiratory-triggered (RT) 2-shots, RT 4-shots, supine vs. prone: RT 4-shot msDWI, T2-weighted fast-spin echo. ASSESSMENT: Protocol optimization and supine vs. prone: three observers performed an image quality assessment of sharpness, aliasing, distortion (vs. T2), perceived SNR, and overall image quality (scale of 1-5). Apparent diffusion coefficients (ADCs) in fibroglandular tissue (FGT) and breast tumors were measured. STATISTICAL TESTS: Effect of study variables on dichotomized ratings (4/5 vs. 1/2/3) and FGT ADCs were assessed with mixed-effects logistic regression. Interobserver agreement utilized Gwet's agreement coefficient (AC). Lesion ADCs were assessed by Bland-Altman analysis and concordance correlation (ρc ). P value <0.05 was considered statistically significant. RESULTS: Protocol optimization: 4-shots significantly improved sharpness and distortion; RT significantly improved sharpness, aliasing, perceived SNR, and overall image quality. FGT ADCs were not significantly different between shots (P = 0.812), FB vs. RT (P = 0.591), or side (P = 0.574). Supine vs. prone: supine images were rated significantly higher for sharpness, aliasing, and overall image quality. FGT ADCs were significantly higher supine; lesion ADCs were highly correlated (ρc  = 0.92). DATA CONCLUSION: Based on image quality, supine msDWI outperformed prone msDWI. Lesion ADCs were highly correlated between the two positions, while FGT ADCs were higher in the supine position. EVIDENCE LEVEL: 2. TECHNICAL EFFICACY: Stage 1.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Humanos , Feminino , Estudos Prospectivos , Decúbito Ventral , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Neoplasias da Mama/diagnóstico por imagem , Imagem Ecoplanar/métodos
5.
Med Teach ; 45(1): 40-48, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36214365

RESUMO

BACKGROUND: Medical students have reported high prevalence of mental health difficulties and burnout. However, there are limited investigations examining the association between resilience and these difficulties. We investigated: (1) depression, anxiety, personal and professional burnout, and comorbidity; (2) demographic and education characteristics associated with these outcomes; (3) the association between resilience and these outcomes; and (4) whether these results were attributable to sampling bias. METHODS: Participants were n = 521 medical students from RCSI University of Medicine and Health Sciences. Outcomes were measured using validated scales. We report descriptive statistics, and risk factors for the difficulties were investigated using generalized linear modelling. RESULTS: One-in-three students reported incidence of depression or anxiety (24.5% co-morbidity). 8.9% of students reported all four difficulties. Difficulties were more common in female students and those in middle years of the programme. Resilience was negatively correlated with all outcomes and stable across demographic and educational variables. Weighting the data for sampling bias did not affect these results. CONCLUSIONS: Our results emphasise the high incidence of depression, anxiety, burnout, and comorbidity in students. We advocate for further investigation into the role of resilience as a modifiable factor that may ameliorate the incidence of depression, anxiety, and burnout in medical students.


Assuntos
Esgotamento Profissional , Estudantes de Medicina , Humanos , Feminino , Estudantes de Medicina/psicologia , Saúde Mental , Estudos Transversais , Depressão/epidemiologia , Ansiedade/epidemiologia , Esgotamento Profissional/epidemiologia
6.
Magn Reson Med ; 85(2): 709-720, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32783339

RESUMO

PURPOSE: To accelerate and improve multishot diffusion-weighted MRI reconstruction using deep learning. METHODS: An unrolled pipeline containing recurrences of model-based gradient updates and neural networks was introduced for accelerating multishot DWI reconstruction with shot-to-shot phase correction. The network was trained to predict results of jointly reconstructed multidirection data using single-direction data as input. In vivo brain and breast experiments were performed for evaluation. RESULTS: The proposed method achieves a reconstruction time of 0.1 second per image, over 100-fold faster than a shot locally low-rank reconstruction. The resultant image quality is comparable to the target from the joint reconstruction with a peak signal-to-noise ratio of 35.3 dB, a normalized root-mean-square error of 0.0177, and a structural similarity index of 0.944. The proposed method also improves upon the locally low-rank reconstruction (2.9 dB higher peak signal-to-noise ratio, 29% lower normalized root-mean-square error, and 0.037 higher structural similarity index). With training data from the brain, this method also generalizes well to breast diffusion-weighted imaging, and fine-tuning further reduces aliasing artifacts. CONCLUSION: A proposed data-driven approach enables almost real-time reconstruction with improved image quality, which improves the feasibility of multishot DWI in a wide range of clinical and neuroscientific studies.


Assuntos
Algoritmos , Imagem de Difusão por Ressonância Magnética , Artefatos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Reprodutibilidade dos Testes
7.
J Magn Reson Imaging ; 53(5): 1594-1605, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33382171

RESUMO

The image quality limitations of echo-planar diffusion-weighted imaging (DWI) are an obstacle to its widespread adoption in the breast. Steady-state DWI is an alternative DWI method with more robust image quality but its contrast for imaging breast cancer is not well-understood. The aim of this study was to develop and evaluate diffusion-weighted double-echo steady-state imaging with a three-dimensional cones trajectory (DW-DESS-Cones) as an alternative to conventional DWI for non-contrast-enhanced MRI in the breast. This prospective study included 28 women undergoing clinically indicated breast MRI and six asymptomatic volunteers. In vivo studies were performed at 3 T and included DW-DESS-Cones, DW-DESS-Cartesian, DWI, and CE-MRI acquisitions. Phantom experiments (diffusion phantom, High Precision Devices) and simulations were performed to establish framework for contrast of DW-DESS-Cones in comparison to DWI in the breast. Motion artifacts of DW-DESS-Cones were measured with artifact-to-noise ratio in volunteers and patients. Lesion-to-fibroglandular tissue signal ratios were measured, lesions were categorized as hyperintense or hypointense, and an image quality observer study was performed in DW-DESS-Cones and DWI in patients. Effect of DW-DESS-Cones method on motion artifacts was tested by mixed-effects generalized linear model. Effect of DW-DESS-Cones on signal in phantom was tested by quadratic regression. Correlation was calculated between DW-DESS-Cones and DWI lesion-to-fibroglandular tissue signal ratios. Inter-observer agreement was assessed with Gwet's AC. Simulations predicted hyperintensity of lesions with DW-DESS-Cones but at a 3% to 67% lower degree than with DWI. Motion artifacts were reduced with DW-DESS-Cones versus DW-DESS-Cartesian (p < 0.05). Lesion-to-fibroglandular tissue signal ratios were not correlated between DW-DESS-Cones and DWI (r = 0.25, p = 0.38). Concordant hyperintensity/hypointensity was observed between DW-DESS-Cones and DWI in 11/14 lesions. DW-DESS-Cones improved sharpness, distortion, and overall image quality versus DWI. DW-DESS-Cones may be able to eliminate motion artifacts in the breast allowing for investigation of higher degrees of steady-state diffusion weighting. Malignant breast lesions in DW-DESS-Cones demonstrated hyperintensity with respect to surrounding tissue without an injection of contrast. LEVEL OF EVIDENCE: 2. TECHNICAL EFFICACY STAGE: 1.


Assuntos
Neoplasias da Mama , Imagem de Difusão por Ressonância Magnética , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Imagem Ecoplanar , Feminino , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos
8.
J Magn Reson Imaging ; 53(3): 807-817, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33067849

RESUMO

BACKGROUND: Diffusion-weighted imaging (DWI) has shown promise to screen for breast cancer without a contrast injection, but image distortion and low spatial resolution limit standard single-shot DWI. Multishot DWI methods address these limitations but introduce shot-to-shot phase variations requiring correction during reconstruction. PURPOSE: To investigate the performance of two multishot DWI reconstruction methods, multiplexed sensitivity encoding (MUSE) and shot locally low-rank (shot-LLR), compared to single-shot DWI in the breast. STUDY TYPE: Prospective. POPULATION: A total of 45 women who consented to have multishot DWI added to a clinically indicated breast MRI. FIELD STRENGTH/SEQUENCES: Single-shot DWI reconstructed by parallel imaging, multishot DWI with four or eight shots reconstructed by MUSE and shot-LLR, 3D T2 -weighted imaging, and contrast-enhanced MRI at 3T. ASSESSMENT: Three blinded observers scored images for 1) general image quality (perceived signal-to-noise ratio [SNR], ghosting, distortion), 2) lesion features (discernment and morphology), and 3) perceived resolution. Apparent diffusion coefficient (ADC) of the lesion was also measured and compared between methods. STATISTICAL TESTS: Image quality features and perceived resolution were assessed with a mixed-effects logistic regression. Agreement among observers was estimated with a Krippendorf's alpha using linear weighting. Lesion feature ratings were visualized using histograms, and correlation coefficients of lesion ADC between different methods were calculated. RESULTS: MUSE and shot-LLR images were rated to have significantly better perceived resolution (P < 0.001), higher SNR (P < 0.005), and a lower level of distortion (P < 0.05) with respect to single-shot DWI. Shot-LLR showed reduced ghosting artifacts with respect to both MUSE (P < 0.001) and single-shot DWI (P < 0.001). Eight-shot DWI had improved perceived SNR and perceived resolution with respect to four-shot DWI (P < 0.005). DATA CONCLUSION: Multishot DWI enables increased resolution and improved image quality with respect to single-shot DWI in the breast. Shot-LLR reconstructs multishot DWI with minimal ghosting artifacts. The improvement of multishot DWI in image quality increases with an increased number of shots. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Artefatos , Feminino , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Reprodutibilidade dos Testes
9.
Magn Reson Med ; 84(1): 170-181, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31782557

RESUMO

PURPOSE: To develop a near-silent and distortionless DWI (sd-DWI) sequence using magnetization-prepared rotating ultrafast imaging sequence. METHODS: A rotating ultrafast imaging sequence was modified with driven-equilibrium diffusion preparation, including eddy-current compensation methods. To compensate for the T1 recovery during readout, a phase-cycling method was used. Both compensation methods were validated in phantoms. The optimized sequence was compared with an EPI diffusion sequence for image distortion, contrast, ADC, and acoustic noise level in phantoms. The sequence was evaluated in 1 brain volunteer, 5 prostate volunteers, and 10 pediatric patients with joint diseases. RESULTS: Combination of several eddy-current compensation methods reduced the artifact to an acceptable level. Phase cycling reduced T1 recovery contamination during readout. In phantom scans, the optimized sequence generated similar image contrast to the EPI diffusion sequence, and ADC maps between the sequences were comparable; sd-DWI had significantly lower acoustic noise (P < .05). In vivo brain scan showed reduced image distortion in sd-DWI compared with the EPI diffusion, although residual motion artifact remains due to brain pulsation. The prostate scans showed that sd-DWI can provide similar ADC compared with EPI diffusion, with no image distortion. Patient scans showed that the sequence can clearly depict joint lesions. CONCLUSION: An sd-DWI sequence was developed and optimized. Compared with conventional EPI diffusion, sd-DWI provided similar diffusion contrast, accurate ADC measurement, improved image quality, and minimal ambient scanning noise. The sequence showed the ability to obtain in vivo diffusion contrast in relatively motion-free body regions, such as prostate and joint.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Artefatos , Encéfalo/diagnóstico por imagem , Criança , Humanos , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes
10.
Magn Reson Med ; 81(2): 1181-1190, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30346058

RESUMO

PURPOSE: The goal of this work is to propose a motion robust reconstruction method for diffusion-weighted MRI that resolves shot-to-shot phase mismatches without using phase estimation. METHODS: Assuming that shot-to-shot phase variations are slowly varying, spatial-shot matrices can be formed using a local group of pixels to form columns, in which each column is from a different shot (excitation). A convex model with a locally low-rank constraint on the spatial-shot matrices is proposed. In vivo brain and breast experiments were performed to evaluate the performance of the proposed method. RESULTS: The proposed method shows significant benefits when the motion is severe, such as for breast imaging. Furthermore, the resulting images can be used for reliable phase estimation in the context of phase-estimation-based methods to achieve even higher image quality. CONCLUSION: We introduced the shot-locally low-rank method, a reconstruction technique for multishot diffusion-weighted MRI without explicit phase estimation. In addition, its motion robustness can be beneficial to neuroimaging and body imaging.


Assuntos
Encéfalo/diagnóstico por imagem , Mama/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Artefatos , Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Análise de Fourier , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Movimento (Física) , Reprodutibilidade dos Testes
14.
Brain ; 141(6): 1691-1702, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29718139

RESUMO

See Roberts and Breakspear (doi:10.1093/brain/awy136) for a scientific commentary on this article.Neurological and psychiatric practice frequently lack diagnostic probes that can assess mechanisms of neuronal communication non-invasively in humans. In N-methyl-d-aspartate (NMDA) receptor antibody encephalitis, functional molecular assays are particularly important given the presence of NMDA antibodies in healthy populations, the multifarious symptomology and the lack of radiological signs. Recent advances in biophysical modelling techniques suggest that inferring cellular-level properties of neural circuits from macroscopic measures of brain activity is possible. Here, we estimated receptor function from EEG in patients with NMDA receptor antibody encephalitis (n = 29) as well as from encephalopathic and neurological patient controls (n = 36). We show that the autoimmune patients exhibit distinct fronto-parietal network changes from which ion channel estimates can be obtained using a microcircuit model. Specifically, a dynamic causal model of EEG data applied to spontaneous brain responses identifies a selective deficit in signalling at NMDA receptors in patients with NMDA receptor antibody encephalitis but not at other ionotropic receptors. Moreover, though these changes are observed across brain regions, these effects predominate at the NMDA receptors of excitatory neurons rather than at inhibitory interneurons. Given that EEG is a ubiquitously available clinical method, our findings suggest a unique re-purposing of EEG data as an assay of brain network dysfunction at the molecular level.


Assuntos
Encefalite Antirreceptor de N-Metil-D-Aspartato/patologia , Mapeamento Encefálico , Encéfalo/fisiopatologia , Eletroencefalografia , Modelos Neurológicos , Dinâmica não Linear , Adolescente , Adulto , Idoso , Encefalite Antirreceptor de N-Metil-D-Aspartato/imunologia , Encefalite Antirreceptor de N-Metil-D-Aspartato/fisiopatologia , Autoanticorpos/metabolismo , Encéfalo/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Vias Neurais/fisiopatologia , Receptores de N-Metil-D-Aspartato/imunologia , Adulto Jovem
15.
Am J Respir Crit Care Med ; 195(10): 1333-1343, 2017 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-27409253

RESUMO

RATIONALE: Objective adherence to inhaled therapy by patients with chronic obstructive pulmonary disease (COPD) has not been reported. OBJECTIVES: To objectively quantify adherence to preventer Diskus inhaler therapy by patients with COPD with an electronic audio recording device (INCA). METHODS: This was a prospective observational study. On discharge from hospital patients were given a salmeterol/fluticasone inhaler with an INCA device attached. Analysis of this audio quantified the frequency and proficiency of inhaler use. MEASUREMENTS AND MAIN RESULTS: Patients with COPD (n = 244) were recruited. The mean age was 71 years, mean FEV1 was 1.3 L, and 59% had evidence of mild/moderate cognitive impairment. By combining time of use, interval between doses, and critical technique errors, thus incorporating both intentional and unintentional nonadherence, a measure "actual adherence" was calculated. Mean actual adherence was 22.6% of that expected if the doses were taken correctly and on time. Six percent had an actual adherence greater than 80%. Hierarchical clustering found three equally sized well-separated clusters corresponding to distinct patterns. Cluster 1 (34%) had low inhaler use and high error rates. Cluster 2 (25%) had high inhaler use and high error rates. Cluster 3 (36%) had overall good adherence. Poor lung function and comorbidities were predictive of poor technique, whereas age and cognition with poor lung function distinguished those with poor adherence and frequent errors in technique. CONCLUSIONS: These data may inform clinicians in understanding why a prescribed inhaler is not effective and to devise strategies to promote adherence in COPD.


Assuntos
Broncodilatadores/administração & dosagem , Nebulizadores e Vaporizadores , Cooperação do Paciente/estatística & dados numéricos , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Administração por Inalação , Idoso , Broncodilatadores/uso terapêutico , Combinação de Medicamentos , Feminino , Fluticasona/administração & dosagem , Humanos , Masculino , Estudos Prospectivos , Xinafoato de Salmeterol/administração & dosagem , Xinafoato de Salmeterol/uso terapêutico
16.
Magn Reson Med ; 78(6): 2136-2148, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28074498

RESUMO

PURPOSE: To develop a radial, double-echo steady-state (DESS) sequence with ultra-short echo-time (UTE) capabilities for T2 measurement of short-T2 tissues along with simultaneous rapid, signal-to-noise ratio (SNR)-efficient, and high-isotropic-resolution morphological knee imaging. METHODS: THe 3D radial UTE readouts were incorporated into DESS, termed UTEDESS. Multiple-echo-time UTEDESS was used for performing T2 relaxometry for short-T2 tendons, ligaments, and menisci; and for Dixon water-fat imaging. In vivo T2 estimate repeatability and SNR efficiency for UTEDESS and Cartesian DESS were compared. The impact of coil combination methods on short-T2 measurements was evaluated by means of simulations. UTEDESS T2 measurements were compared with T2 measurements from Cartesian DESS, multi-echo spin-echo (MESE), and fast spin-echo (FSE). RESULTS: UTEDESS produced isotropic resolution images with high SNR efficiency in all short-T2 tissues. Simulations and experiments demonstrated that sum-of-squares coil combinations overestimated short-T2 measurements. UTEDESS measurements of meniscal T2 were comparable to DESS, MESE, and FSE measurements while the tendon and ligament measurements were less biased than those from Cartesian DESS. Average UTEDESS T2 repeatability variation was under 10% in all tissues. CONCLUSION: The T2 measurements of short-T2 tissues and high-resolution morphological imaging provided by UTEDESS makes it promising for studying the whole knee, both in routine clinical examinations and longitudinal studies. Magn Reson Med 78:2136-2148, 2017. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Tecido Adiposo/diagnóstico por imagem , Adulto , Algoritmos , Feminino , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Articulação do Joelho/diagnóstico por imagem , Ligamentos/diagnóstico por imagem , Masculino , Meniscos Tibiais/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído , Tendões/diagnóstico por imagem
19.
J Magn Reson Imaging ; 41(3): 616-23, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24585455

RESUMO

PURPOSE: To investigate the diagnostic accuracy and clinical usefulness of the rim sign in breast lesions observed in diffusion-weighted magnetic resonance imaging (DWI). MATERIALS AND METHODS: The magnetic resonance imaging (MRI) findings of 98 pathologically confirmed lesions (62 malignant and 36 benign) in 84 patients were included. Five breast radiologists were asked to independently review the breast MRI results, to grade the degree of high peripheral signal, the "rim sign," in the DWI, and to confirm the mean apparent diffusion coefficient (ADCmean ) values. We analyzed the diagnostic accuracy and compared the consensus (when ≥ 4 of 5 independent reviewers agreed) results of the rim sign with the ADCmean values. Additionally, we evaluated the correlation between the dynamic contrast-enhanced (DCE)-MRI morphologic appearance and DWI rim sign. RESULTS: According to the consensus results, the rim sign in DWI was observed on 59.7% of malignant lesions and 19.4% of benign lesions. The sensitivity, specificity, and area under the curve (AUC) value for the rim sign in DWI were 59.7%, 80.6%, and 0.701, respectively. The sensitivity, specificity, and AUC value for the ADCmean value (criteria ≤ 1.46 × 10(-3) mm(2) /sec) were 82.3%, 63.9%, and 0.731, respectively. Based on consensus, no correlation was observed between the DCE-MRI and DWI rim signs. CONCLUSION: In DWI, a high-signal rim is a valuable morphological feature for improving specificity in DWI.


Assuntos
Neoplasias da Mama/diagnóstico , Imagem de Difusão por Ressonância Magnética , Interpretação de Imagem Assistida por Computador/métodos , Adulto , Idoso , Mama/patologia , Meios de Contraste , Feminino , Gadolínio , Humanos , Aumento da Imagem , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
20.
Magn Reson Med ; 71(1): 95-104, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23504943

RESUMO

Radial trajectories facilitate high-resolution balanced steady state free precession (bSSFP) because the efficient gradients provide more time to extend the trajectory in k-space. A number of radial bSSFP methods that support fat-water separation have been developed; however, most of these methods require an environment with limited B0 inhomogeneity. In this work, high-resolution bSSFP with fat-water separation is achieved in more challenging B0 environments by combining a 3D radial trajectory with the IDEAL chemical species separation method. A method to maintain very high resolution within the timing constraints of bSSFP and IDEAL is described using a dual-pass pulse sequence. The sampling of a unique set of radial lines at each echo time is investigated as a means to circumvent the longer scan time that IDEAL incurs as a multiecho acquisition. The manifestation of undersampling artifacts in this trajectory and their effect on chemical species separation are investigated in comparison to the case in which each echo samples the same set of radial lines. This new bSSFP method achieves 0.63 mm isotropic resolution in a 5-min scan and is demonstrated in difficult in vivo imaging environments, including the breast and a knee with ACL reconstruction hardware at 1.5 T.


Assuntos
Algoritmos , Lesões do Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/patologia , Mama/anatomia & histologia , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Ligamento Cruzado Anterior/cirurgia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA