Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Int J Legal Med ; 132(6): 1555-1573, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29523969

RESUMO

The GlobalFiler™ PCR Amplification Kit is a single multiplex assay that amplifies a set of 24 markers, which encompass the European Standard Set and CODIS (Combined DNA Index System) recommended composite set of loci. In addition to more loci and a 6-dye chemistry format, the Master Mix has been formulated to allow higher sample loading volume for trace DNA samples. The GlobalFiler™ Kit has been optimized to deliver high performance on casework samples, while also delivering fast thermal cycling, with an amplification time of approximately 80 min. Here, we report the results of the developmental validation study which followed the SWGDAM (Scientific Working Group on DNA Analysis Methods) guidelines and includes data for PCR-based studies, sensitivity, species specificity, stability, precision, reproducibility and repeatability, concordance, stutter, DNA mixtures, and performance on mock casework samples. The results validate the multiplex design as well as demonstrate the kit's robustness, reliability, and suitability as an assay for human identification with casework DNA samples.


Assuntos
Impressões Digitais de DNA , Repetições de Microssatélites , Reação em Cadeia da Polimerase Multiplex/instrumentação , Animais , Osso e Ossos/química , Degradação Necrótica do DNA , Frequência do Gene , Humanos , Grupos Raciais/genética , Reprodutibilidade dos Testes , Especificidade da Espécie
2.
Electrophoresis ; 37(12): 1659-68, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27059083

RESUMO

Y chromosome STR loci are used in forensics primarily for identification purposes by determining the male lineages. The Henan province in China has established a large Y-STR (>200 000 profiles) database for criminal investigations. A large proportion of the Y-STR profiles in the database were generated using either the Applied Biosystems Yfiler(ۛ) or Yfiler(ۛ) Plus PCR Amplification kits. The additional loci in the Yfiler Plus kit as compared to the Yfiler kit results in a concomitant cumulative mutation rate increase across the loci. Therefore, in those cases when two profiles have one to a few mismatched loci, it is difficult to determine if they are from the same lineage. In this study, 7405 unrelated male profiles were manually selected from the database. Analysis showed higher power of discrimination than the corresponding Yfiler haplotypes. Further, the distributions of the number of mismatched loci and the mismatched steps were generated for father-son, grandfather-grandson, uncle-nephew, and cousins (i.e. one, two, three, and four meioses, respectively) by exhaustive pairwise comparison of the unrelated profiles using a dynamic programming approach. The same distributions were generated for unrelated pairs with mutation rates of the loci. With the distributions, the false negative and false positive rates were determined. Two Yfiler profiles with ≤2 mismatched loci or ≤2 steps are more likely from the same lineage than unrelated lineages, and two Yfiler Plus profiles with ≤4 mismatched loci or ≤5 mismatched steps are more likely from the same lineage.


Assuntos
Cromossomos Humanos Y/genética , Medicina Legal/métodos , Paternidade , China , Loci Gênicos/genética , Haplótipos/genética , Humanos , Masculino , Repetições de Microssatélites , Mutação , Linhagem
3.
Sci Rep ; 13(1): 14539, 2023 09 04.
Artigo em Inglês | MEDLINE | ID: mdl-37666878

RESUMO

The YFiler Platinum Casework PCR Amplification Kit is a 6-dye multiplex assay that simultaneously amplifies a set of 38 male-specific, Y-chromosome Short Tandem Repeat (YSTR) markers (DYS576, DYS389I, DYS635, DYS389II, DYS627, DYS549, DYS593, DYS645, DYS460, DYS458, DYS19, YGATAH4, DYS448, DYS391, DYS557, DYS522, DYS456, DYS390, DYS438, DYS392, DYS518, DYS444, DYS533, DYS570, DYS437, DYS385, DYS449, DYS643, DYS596, DYS393, DYS439, DYS481, DYF387S1, DYS527, DYS447), three insertion/deletion polymorphic markers (Yindels: rs771783753, rs759551978, rs199815934), and an internal quality control (IQC) system. When compared to the YFiler Platinum PCR Amplification kit for database samples, YFiler Platinum Casework kit was developed to include an improved Primer Mix incorporating a brighter TED dye, an updated internal quality control system, better resolution of large DNA fragments in Applied Biosystems POP-4 Polymer, and reduced female DNA cross-reactivity. Here, we report the results of the developmental validation study which followed the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines and includes data for PCR-based studies, sensitivity, species specificity, stability, precision, reproducibility and repeatability, population concordance, stutter, DNA mixtures, and performance on mock casework samples. The results validate the multiplex design as well as demonstrate the kit's robustness, reliability, and suitability as an assay for human identification with casework DNA samples.


Assuntos
Platina , Receptores Proteína Tirosina Quinases , Humanos , Feminino , Masculino , Reprodutibilidade dos Testes , Fosforilação , Reação em Cadeia da Polimerase
4.
Int J Legal Med ; 125(1): 101-9, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20878415

RESUMO

The AmpFlSTR® NGM™ PCR Amplification Kit enables amplification of 15 autosomal short tandem repeat (STR) loci. The loci are the ten STRs in the SGM Plus® Kit plus the EDNAP and ENSFI recommended STRs D10S1248, D22S1045, D2S441, D1S1656, and D12S391. Allele frequency and other forensically relevant statistics data were generated for the NGM loci in three US population groups (African Americans, Caucasians, and Hispanics). The analyses support that the NGM multiplex is one of the most informative STR multiplex kits available to the forensic science community. At the population level, there are no more detectable departures from expectations of the independence of alleles within as well as between loci than would be expected due to chance, even for the two syntenic loci vWA and D12S391; however, linkage analysis in three large pedigree families shows close linkage between these two loci with a recombination fraction of 0.108. Therefore, in contrast to the practices in calculating the rarity of a DNA profile, for kinship analyses independence between the loci, vWA and D12S391 cannot be assumed.


Assuntos
Genética Populacional , Sequências de Repetição em Tandem , Impressões Digitais de DNA/métodos , Frequência do Gene , Ligação Genética , Humanos , Reação em Cadeia da Polimerase , Grupos Raciais/genética , Estados Unidos
5.
Forensic Sci Int Genet ; 53: 102494, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33740707

RESUMO

The VeriFiler™ Plus PCR Amplification Kit is a 6-dye multiplex assay that simultaneously amplifies a set of 23 autosomal markers (D3S1358, vWA, D16S539, CSF1PO, D6S1043, D8S1179, D21S11, D18S51, D5S818, D2S441, D19S433, FGA, D10S1248, D22S1045, D1S1656, D13S317, D7S820, Penta E, Penta D, TH01, D12S391, D2S1338, and TPOX), a quality indicator system, and two sex-identification markers. Combined, the markers satisfy the requirements of the Chinese National autosomal DNA database as well as expanded CODIS (Combined DNA Index System). The VeriFiler Plus kit was developed with an improved Master Mix which incorporates the brighter TED™ dye, and accommodates a higher sample loading volume thus allowing for increased sensitivity and enabling maximum information recovery from challenging casework samples including touch, degraded, and inhibited samples. Here, we report the results of the developmental validation study which followed the SWGDAM (Scientific Working Group on DNA Analysis Methods) guidelines and includes data for PCR-based studies, sensitivity, species specificity, stability, precision, reproducibility and repeatability, concordance, stutter, DNA mixtures, and performance on mock casework samples. The results validate the multiplex design as well as demonstrate the kit's robustness, reliability, and suitability as an assay for human identification with casework DNA samples.


Assuntos
Reação em Cadeia da Polimerase Multiplex/instrumentação , Animais , Degradação Necrótica do DNA , Impressões Digitais de DNA , Feminino , Genética Forense/instrumentação , Genética Populacional , Humanos , Masculino , Repetições de Microssatélites , Reprodutibilidade dos Testes , Especificidade da Espécie
6.
Forensic Sci Int Genet ; 42: 190-197, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31374458

RESUMO

The Huaxia™ Platinum Kit for short tandem repeat (STR) amplification was designed to meet the needs of the rapidly growing Chinese forensic database. This PCR multiplex allows simultaneous amplification of the following autosomal loci: D3S1358, vWA, D16S539, CSF1PO, TPOX, D8S1179, D21S11, D18S51, Penta E, D2S441, D19S433, TH01, FGA, D22S1045, D5S818, D13S317, D7S820, D6S1043, D10S1248, D1S1656, D12S391, D2S1338, Penta D and the gender-identification markers Yindel, and AMEL. The Huaxia™ Platinum Kit enables direct amplification from blood and buccal samples stored on treated and untreated paper, and features an optimized PCR protocol that yields time to results in less than 45 min. Developmental validation testing followed SWGDAM guidelines and demonstrated that this assay produces reproducible and accurate results. Studies on 798 individuals in 4 major Chinese ethnic groups produced highly concordant results with other commercially available STR genotyping kits. The validation results demonstrate that the Huaxia™ Platinum Kit is a robust and reliable identification system for forensic DNA databasing applications.


Assuntos
Etnicidade/genética , Genética Populacional , Repetições de Microssatélites , Reação em Cadeia da Polimerase Multiplex/métodos , Animais , Povo Asiático/genética , Análise Química do Sangue , China , Impressões Digitais de DNA , Frequência do Gene , Humanos , Mucosa Bucal/química , Especificidade da Espécie , Manejo de Espécimes
7.
J Forensic Sci ; 52(4): 870-3, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17553078

RESUMO

The AmpFlSTR MiniFiler polymerase chain reaction amplification kit developed by Applied Biosystems enables size reduction on eight of the larger STR loci amplified in the Identifiler kit, which will aid recovery of information from highly degraded DNA samples. The MiniFiler Kit amplifies CSF1PO, FGA, D2S1338, D7S820, D13S317, D16S539, D18S51, and D21S11 as well as the sex-typing locus amelogenin. A total of 1308 samples were evaluated with both the MiniFiler and Identifiler STR kits: 449 African American, 445 Caucasian, 207 Hispanic, and 207 Asian individuals. Full concordance between Identifiler and MiniFiler Kits was observed in 99.7% (10,437 out of 10,464) STR allele calls compared. The 27 differences seen are listed in Table 1 and encompass the loci D13S317 (n = 14) and D16S539 (n = 10) as well as D18S51 (n = 1), D7S820 (n = 1), and CSF1PO (n = 1). Genotyping discrepancies between the Identifiler and MiniFiler kits were confirmed by reamplification of the samples and further testing using the PowerPlex 16 kit in many cases. DNA sequence analysis was also performed in order to understand the nature of the genetic variations causing the allele dropout or apparent repeat unit shift.


Assuntos
Impressões Digitais de DNA/métodos , DNA/genética , Genética Forense/métodos , Repetições de Microssatélites/genética , Reação em Cadeia da Polimerase/métodos , DNA/química , Impressões Digitais de DNA/normas , Genética Forense/normas , Humanos , Masculino , Reação em Cadeia da Polimerase/normas , Análise de Sequência de DNA
8.
J Forensic Sci ; 51(5): 1069-73, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17018083

RESUMO

Stutter products generated during DNA amplification by the polymerase chain reaction (PCR) may complicate mixture interpretation. The PCR amplification of the DYS392 locus typically results in three distinct detectable PCR products: the true allele product (N), a stutter product three bases smaller (N-3), and a reproducible low-level product, three bases larger (N+3). Sequence analysis of the N+3 product demonstrated that its sequence is one TAT repeat longer than the true allele product. Our experiments demonstrated that the quantity of both N-3 and N+3 stutter increased as the allele number increased. The percent stutter also increased as the magnesium concentration was increased in the reaction, as well as when the amount of input DNA was decreased. As both stutter products behave in a similar and reproducible fashion, the same rules that apply to the interpretation of N-3 stutter products in short tandem repeat analysis, can be applied to N+3 stutters. The characterization of the DYS392 N+3 product is the first detailed published study of a stutter product larger than the true allele.


Assuntos
Cromossomos Humanos Y , Repetições de Trinucleotídeos , Primers do DNA , Medicina Legal , Humanos , Cloreto de Magnésio , Masculino , Reação em Cadeia da Polimerase
9.
J Forensic Sci ; 51(2): 344-8, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16566768

RESUMO

During an extensive multipopulation study with Y-short tandem repeat (STR) loci, amplified using the AmpFlSTR Yfiler PCR amplification kit, amplification of a 71 bp fragment was observed in 2.32% of the male samples analyzed (N = 3141). By direct sequencing of this fragment, it was determined that the primer binding sequences were identical to those of the DYS456 locus. A T to G single-nucleotide polymorphism (SNP) enabled amplification of the 71 bp fragment. The SNP is located within an X-Y homologous region at Xq21.31 and was observed with the highest frequency within the African American and Sub-Saharan African populations in our study. Presence of SNP on the X chromosome did not interfere with the reliability of typing the DYS456 locus and the other Y-STR loci typeable using the AmpFlSTR Yfiler PCR amplification kit. Full profiles in a mixture of male:female at 1:4000 were obtained using the current configuration of the AmpFlSTR Yfiler kit even in the presence of female DNA containing the G variant.


Assuntos
Cromossomos Humanos X , Impressões Digitais de DNA , Polimorfismo de Nucleotídeo Único , Sequências de Repetição em Tandem , Cromossomos Humanos Y , Primers do DNA , Feminino , Frequência do Gene , Humanos , Masculino , Mutação , Reação em Cadeia da Polimerase , Grupos Raciais/genética , Análise de Sequência de DNA
10.
J Forensic Sci ; 51(1): 64-75, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16423225

RESUMO

In the past 5 years, there has been a substantial increase in the use of Y-short tandem repeat loci (Y-STRs) in forensic laboratories, especially in cases where typing autosomal STRs has met with limited success. The AmpFlSTR Yfiler PCR amplification kit simultaneously amplifies 17 Y-STR loci including the loci in the "European minimal haplotype" (DYS19, DYS385a/b, DYS389I, DYS389II, DYS390, DYS391, DYS392, and DYS393), the Scientific Working Group on DNA Analysis Methods (SWGDAM) recommended Y-STR loci (DYS438 and DYS439), and the highly polymorphic loci DYS437, DYS448, DYS456, DYS458, Y GATA H4, and DYS635 (formerly known as Y GATA C4). The Yfiler kit was validated according to the FBI/National Standards and SWGDAM guidelines. Our results showed that full profiles are attainable with low levels of male DNA (below 125 pg) and that under optimized conditions, no detectable cross-reactive products were obtained on human female DNA, bacteria, and commonly encountered animal species. Additionally, we demonstrated the ability to detect male specific profiles in admixed male and female blood samples at a ratio of 1:1000.


Assuntos
Cromossomos Humanos Y , Impressões Digitais de DNA/métodos , Sequências de Repetição em Tandem , Animais , Gatos/genética , Impressões Digitais de DNA/normas , Primers do DNA , Cães/genética , Genética Populacional , Humanos , Masculino , Pan troglodytes/genética , Reação em Cadeia da Polimerase , Grupos Raciais/genética , Reprodutibilidade dos Testes , Especificidade da Espécie
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA