Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Clin Chem ; 27(6): 896-900, 1981 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-7237770

RESUMO

A method is described for separating antibody-bound from free fractions in ligand assays by column affinity chromatography, and its application to radioimmunoassay of choriomammotropin. In the method, 70 x 10 mm (i.d.) polypropylene columns containing about 150 mg of immunosorbent (goat anti-rabbit gamma-globulins covalently linked to Sepharose CL-4B) are used. Standards or unknowns, tracer and antiserum, pipetted into bottom-capped columns, are kept separated from the immunosorbent bed by a porous polyethylene disc and allowed to react for 15 min at room temperature. The reaction mixture is then allowed to pass through the columns by removing the bottom caps. Free antigen is eluted by washing the column, and discarded; antibody-bound fractions remain bound to the immunosorbent. The radioactivity in the columns is counted. The major advantages of the present technique, arising from the liquid-phase reaction combined with the solid-phase separation by column affinity chromatography, are the very low nonspecific binding (less than 1%), good sensitivity (0.02 mg/L), good precision (CV 3.4%), and simple and fast (30-min) assay. For 50 clinical samples so assayed (gamma) and compared with a polyethylene glycol precipitation technique (x), the regression equation was: y - 0.14 + 0.98x (r = 0.994). The assay method was clinical validated by 3493 determinations.


Assuntos
Lactogênio Placentário/sangue , Cromatografia de Afinidade/métodos , Feminino , Humanos , Imunoadsorventes , Ligantes , Lactogênio Placentário/isolamento & purificação , Gravidez , Radioimunoensaio/métodos
2.
Dig Dis Sci ; 44(1): 155-62, 1999 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9952237

RESUMO

We evaluated the agreement between wedged hepatic vein pressure (WHVP), portal vein pressure (PVP), and its relationship with portal hemodynamics in 21 patients with HCV-related cirrhosis with esophageal varices. Direct measurements of the portohepatic gradient (HVPG) were obtained by ultrasound-guided fine needle puncture of the right hepatic and the portal veins. In five cases PVP was 6.4-10.4 mm Hg higher than WHVP. In 12 cases measurements were similar (WHVP - PVP < or = 3 mm Hg). In the remaining four cases WHVP was 3.6-9.6 mm Hg higher than PVP. WHVP and PVP agreement was not related to HVPG mean value, Child-Pugh score, or grading of esophageal varices. By contrast, the difference between WHVP and PVP was inversely related to the portal flow velocity (P = 0.053) and directly related to the portal vascular resistance (P = 0.02). Whereas the portal branches were visualized in patients with WHVP lower or similar to PVP, a predominant left portosystemic collateral flow was observed in patients with WHVP > PVP. Our data point out that, in patients with cirrhosis due to hepatitis C virus infection, discrepant HVPG values reflect true hemodynamic differences.


Assuntos
Hemodinâmica/fisiologia , Veias Hepáticas/fisiopatologia , Hepatite C/complicações , Cirrose Hepática/etiologia , Cirrose Hepática/fisiopatologia , Sistema Porta/fisiopatologia , Veia Porta/fisiopatologia , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Circulação Colateral , Varizes Esofágicas e Gástricas/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resistência Vascular , Pressão Venosa/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA