Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
J Radiol Prot ; 41(1)2021 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-33264760

RESUMO

The study of low dose and low-dose rate exposure is of central importance in understanding the possible range of health effects from prolonged exposures to radiation. The One Million Person Study of Radiation Workers and Veterans (MPS) of low-dose health effects was designed to evaluate radiation risks among healthy American workers and veterans. The MPS is evaluating low-dose and dose-rate effects, intakes of radioactive elements, cancer and non-cancer outcomes, as well as differences in risks between women and men. Medical radiation workers make up a large group of individuals occupationally exposed to low doses of radiation from external x-ray/gamma exposures. For the MPS, about 100 000 United States medical radiation workers have been selected for study. The approach to the complex dosimetry circumstances for such workers over three to four decades of occupation were initially and broadly described in National Council on Radiation Protection and Measurements (NCRP) Report No. 178. NCRP Commentary No. 30 provides more detail and describes an optimum approach for using personal monitoring data to estimate lung and other organ doses applicable to the cohort and provides specific precautions/considerations applicable to the dosimetry of medical radiation worker organ doses for use in epidemiologic studies. The use of protective aprons creates dosimetric complexity. It is recommended that dose values from dosimeters worn over a protective apron be reduced by a factor of 20 for estimating mean organ doses to tissues located in the torso and that 15% of the marrow should be assumed to remain unshielded for exposure scenarios when aprons are worn. Conversion coefficients relating personal dose equivalent,Hp(10) in mSv, to mean absorbed doses to organs and tissues,DTin mGy, for females and males for six exposure scenarios have been determined and presented for use in the MPS. This Memorandum summarises several key points in NCRP Commentary No. 30.


Assuntos
Exposição Ocupacional , Proteção Radiológica , Feminino , Humanos , Masculino , Exposição Ocupacional/análise , Roupa de Proteção , Doses de Radiação , Radiometria , Estados Unidos
2.
Science ; 173(3994): 320-2, 1971 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-17809214

RESUMO

Heat and steam from the crater fumaroles have melted over 5700 feet (1737 meters) of cave passage in the ice-filled east crater of Mount Rainier. The caves are in approximate balance with the present geothermal heat release. Future changes in the thermal activity of the summit cone will cause corresponding changes in cave passage dimensions, location, and ceiling and wall ablation features.

3.
Science ; 280(5369): 1576-80, 1998 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-9616115

RESUMO

High-resolution spectroscopy of Mars' atmosphere with the Hubble Space Telescope revealed the deuterium Lyman alpha line at an intensity of 23 +/- 6 rayleighs. This measured intensity corresponds to HD/H2 = 1.5 +/- 0.6 x 10(-4), which is smaller by a factor of 11 than HDO/H2O. This indicates that fractionation of HD/H2 relative to that of HDO/H2O is not kinetically controlled by the rates of formation and destruction of H2 and HD but is thermodynamically controlled by the isotope exchange HD + H2O left and right arrow HDO + H2. Molecular hydrogen is strongly depleted in deuterium relative to water on Mars because of the very long lifetime of H2 (1200 years). The derived isotope fractionation corresponds to an estimate of a planetwide reservoir of water ice about 5 meters thick that is exchangeable with the atmosphere.


Assuntos
Deutério/análise , Meio Ambiente Extraterreno , Hidrogênio/análise , Marte , Água , Atmosfera , Gelo , Temperatura
4.
Science ; 232(4757): 1523-8, 1986 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-17773501

RESUMO

Gaseous, neutral H(2)O was detected in the coma of comet Halley on 22.1 and 24.1 December 1985 Universal Time. Nine spectral lines of thev(3) band (2.65 micrometers) were found by means of a Fourier transform spectrometer (lambda/triangle uplambda approximately 10(5)) on the NASA-Kuiper Airborne Observatory. The water production rate was approximately 6 x 10(28) molecules per second on 22.1 December and 1.7 x 10(29) molecules per second on 24.1 December UT. The numbers of spectral lines and their intensities are in accord with nonthermal-equilibrium cometary models. Rotational populations are derived from the observed spectral line intensities and excitation conditions are discussed. The ortho-para ratio was found to be 2.66+/-0.13, corresponding to a nuclear-spin temperature of 32 K (+5 K, -2 K), possibly indicating that the observed water vapor originated from a low-temperature ice.

5.
Science ; 272(5266): 1310-4, 1996 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-8650540

RESUMO

The saturated hydrocarbons ethane (C2H6) and methane (CH4) along with carbon monoxide (CO) and water (H2O) were detected in comet C/1996 B2 Hyakutake with the use of high-resolution infrared spectroscopy at the NASA Infrared Telescope Facility on Mauna Kea, Hawaii. The inferred production rates of molecular gases from the icy, cometary nucleus (in molecules per second) are 6.4 X 10(26) for C2H6, 1.2 X 10(27) for CH4, 9.8 X 10(27) for CO, and 1.7 X 10(29) for H2O. An abundance of C2H6 comparable to that of CH4 implies that ices in C/1996 B2 Hyakutake did not originate in a thermochemically equilibrated region of the solar nebula. The abundances are consistent with a kinetically controlled production process, but production of C2H6 by gas-phase ion molecule reactions in the natal cloud core is energetically forbidden. The high C2H6/CH4 ratio is consistent with production of C2H6 in icy grain mantles in the natal cloud, either by photolysis of CH4-rich ice or by hydrogen-addition reactions to acetylene condensed from the gas phase.


Assuntos
Monóxido de Carbono/análise , Etano/análise , Meteoroides , Metano/análise , Água/análise , Meio Ambiente Extraterreno , Gelo , Análise Espectral
6.
Science ; 212(4490): 45-9, 1981 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-17747630

RESUMO

Fully resolved intensity profiles of various lines in the carbon dioxide band at 10.4 micrometers have been measured on Mars with an infrared heterodyne spectrometer. Analysis of the line shapes shows that the Mars atmosphere exhibits positive gain in these lines. The detection of natural optical gain amplification enables identification of these lines as a definite natural laser.

7.
Science ; 221(4607): 268-71, 1983 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-17815195

RESUMO

A ground-based search for stratospheric chlorine monoxide was carried out during May and October 1981 with an infrared heterodyne spectrometer in the solar absorption mode. Lines due to stratospheric nitric acid and tropospheric carbonyl sulfide were detected at about 0.2 percent absorptance levels, but the expected 0.1 percent lines of chlorine monoxide in this same region were not seen. Stratospheric chlorine monoxide is less abundant by at least a factor of 7 than is indicated by in situ measurements, and the upper limit for the integrated vertical column density of chlorine monoxide is 2.3 x 10(13) molecules per square centimeter at the 95 percent confidence level. These results imply that the release of chlorofluorocarbons may be significantly less important for the destruction of stratospheric ozone than is currently thought.

8.
Science ; 277(5331): 1488-91, 1997 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-9278508

RESUMO

An image of comet Hale-Bopp (C/1995 O1) in soft x-rays reveals a central emission offset from the nucleus, as well as an extended emission feature that does not correlate with the dust jets seen at optical wavelengths. Neon was found to be depleted in the cometary ice by more than a factor of 25 relative to solar abundance, which suggests that ices in Hale-Bopp formed at (or later experienced) temperatures higher than 25 kelvin. A helium line emission at a wavelength of 584 angstroms was detected and may be attributable to charge transfer of solar wind alpha particles in the cometary coma. Ionized oxygen and another helium line contribute to an emission observed at 538 angstroms.


Assuntos
Hélio/análise , Meteoroides , Neônio/análise , Oxigênio/análise , Poeira Cósmica , Gelo , Temperatura , Raios X
9.
Science ; 292(5520): 1334-9, 2001 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-11359002

RESUMO

In the current paradigm, Oort cloud comets formed in the giant planets' region of the solar nebula, where temperatures and other conditions varied greatly. The measured compositions of four such comets (Halley, Hyakutake, Hale-Bopp, and Lee) are consistent with formation from interstellar ices in the cold nebular region beyond Uranus. The composition of comet C/1999 S4 (LINEAR) differs greatly, which suggests that its ices condensed from processed nebular gas, probably in the Jupiter-Saturn region. Its unusual organic composition may require reevaluation of the prebiotic organic material delivered to the young Earth by comets.

10.
Science ; 348(6231): 218-21, 2015 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-25745065

RESUMO

We measured maps of atmospheric water (H2O) and its deuterated form (HDO) across the martian globe, showing strong isotopic anomalies and a significant high deuterium/hydrogen (D/H) enrichment indicative of great water loss. The maps sample the evolution of sublimation from the north polar cap, revealing that the released water has a representative D/H value enriched by a factor of about 7 relative to Earth's ocean [Vienna standard mean ocean water (VSMOW)]. Certain basins and orographic depressions show even higher enrichment, whereas high-altitude regions show much lower values (1 to 3 VSMOW). Our atmospheric maps indicate that water ice in the polar reservoirs is enriched in deuterium to at least 8 VSMOW, which would mean that early Mars (4.5 billion years ago) had a global equivalent water layer at least 137 meters deep.


Assuntos
Marte , Água , Atmosfera , Deutério/análise , Óxido de Deutério , Evolução Planetária , Meio Ambiente Extraterreno , Gelo
11.
Am J Cardiol ; 65(5): 377-82, 1990 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-2137281

RESUMO

Doppler analysis of mitral flow provides a means of analyzing left ventricular (LV) diastolic function. While experimental studies have suggested that changes in left atrial pressure may affect the normal pattern of early diastolic filling, the effect of such changes on abnormal patterns of filling is unknown. Accordingly, the Doppler pattern of LV filling was analyzed in 20 subjects with LV hypertrophy (mean age 59 +/- 13 years, +/- standard deviation), in 25 healthy normal subjects (29 +/- 6 years) and in 11 elderly subjects (68 +/- 5 years). All underwent Doppler examination of LV inflow at rest and immediately after postural changes. In all 3 groups, head-down positioning increased early diastolic flow velocity (E) (p less than 0.001), and raised the E to late diastolic flow velocity (A) ratio (p less than 0.01). However, an abnormal E/A ratio never approached a normal resting value. Likewise, although E and the E/A ratio decreased significantly in normal subjects with head-up positioning, it did not become abnormal. The magnitude of change in E, A and E/A ratio did not differ among the 3 groups in response to postural changes. Thus, alterations of LV loading conditions alter the pattern of LV filling, whether normal or abnormal at baseline. The magnitude of change appears to be independent of the resting flow pattern. Although loading conditions may affect the Doppler pattern of filling, simple changes in venous return do not "normalize" an abnormal pattern, nor do they "abnormalize" a normal pattern.


Assuntos
Cardiomegalia/fisiopatologia , Ecocardiografia Doppler , Contração Miocárdica/fisiologia , Adulto , Idoso , Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Coronária/fisiologia , Humanos , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Postura/fisiologia , Manobra de Valsalva
12.
J Occup Environ Med ; 43(7): 635-40, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11464395

RESUMO

From the 1950s to the 1980s, hexavalent chromium compounds were used as additives at certain water-cooling towers at three southern California gas compressor facilities. Claims of potential residential chromium exposure prompted the examination of age-adjusted mortality rates during 1989 to 1998 for lung cancer, all cancer, and all deaths for neighborhoods near versus distant from the plants. Differences in the rates between areas tended to be small and not statistically significant. The only significant difference was a lower, rather than higher, rate of total cancer among women in the potentially exposed areas. Study limitations preclude a definitive assessment of risk, but similar to previous investigations of cancer in relation to environmental chromium exposure in other locations, this study found no evidence of a cancer hazard among residents living near these California gas compressor facilities.


Assuntos
Cromo/efeitos adversos , Exposição Ambiental/estatística & dados numéricos , Neoplasias/induzido quimicamente , Neoplasias/mortalidade , Poluição Química da Água/efeitos adversos , California/epidemiologia , Exposição Ambiental/efeitos adversos , Feminino , Humanos , Neoplasias Pulmonares/induzido quimicamente , Neoplasias Pulmonares/mortalidade , Masculino , Distribuição por Sexo
13.
Icarus ; 218(1): 644-653, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32675835

RESUMO

We present spectral and spatial information for major volatile species in Comet 10P/Tempel 2, based on high-dispersion infrared spectra acquired on UT 2010 July 26 (heliocentric distance R h = 1.44 AU) and September 18 (R h = 1.62 AU), following the comet's perihelion passage on UT 2010 July 04. The total production rate for water on July 26 was (1.90 ± 0.12) × 1028 molecules s-1, and abundances of six trace gases (relative to water) were: CH3OH (1.58% ± 0.23%), C2H6 (0.39% ± 0.04%), NH3 (0.83% ± 0.20%), and HCN (0.13% ± 0.02%). A detailed analysis of intensities for water emission lines provided a rotational temperature of 35 ± 3 K. The mean OPR is consistent with nuclear spin populations in statistical equilibrium (OPR = 3.01 ± 0.18), and the (1σ) lower bound corresponds to a spin temperature >38 K. Our measurements were contemporaneous with a jet-like feature observed at optical wavelengths. The spatial profiles of four primary volatiles display strong enhancements in the jet direction, which favors release from a localized vent on the nucleus. The measured IR continuum is much more sharply peaked and is consistent with a dominant contribution from the nucleus itself. The peak intensities for H2O, CH3OH, and C2H6 are offset by ~200 km in the jet direction, suggesting the possible existence of a distributed source, such as the release of icy grains that subsequently sublimed in the coma. On UT September 18, no obvious emission lines were present in our spectra, nevertheless we obtained a 3σ upper limit Q(H2O) < 2.86 × 1027 molecules s-1.

16.
Icarus ; 79: 362-81, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-11542163

RESUMO

Observations of Comets Halley and Wilson reveal an emission feature peaking near 3.4 micrometers, characteristic of C-H stretching in hydrocarbons. We have previously (Chyba and Sagan 1987a, Nature (London) 330, 350-353) fit this feature with a simple two-component thermal emission model for dust in the cometary coma (one component corresponding to large, cool, optically thick particles, the other due to smaller, hotter, organic grains) by employing laboratory spectra of the organic residue produced by the irradiation of carbon-bearing ices. This procedure yields optical depths in agreement with limits from spacecraft data. One remarkable result of such modeling is that at approximately 1 AU emission features at wavelengths longer than 3.4 micrometers are largely overwhelmed (or "diluted") by continuum emission. The large particle optical depth is approximately 10(2) times that of the emitting organics, so that, relative to the continuum, only near the continuum minimum can the emitting organics make a significant contribution. At approximately 1 AU, the 3.4-micrometers feature is the sole feature near that minimum, lying at the intersection of the curves for particle thermal emission and scattered sunlight. Thus, since as a comet moves away from perihelion the intersection of the scattered solar spectrum and the comet's thermal emission spectrum will move to longer wavelengths, we predicted (Chyba and Sagan 1987a) that the 3.4-micrometers feature is diluted while those at longer wavelengths are progressively revealed--so long as the comet retains its coma. We now quantitatively develop this model and find agreement with observational data for Comet Halley for certain plausible values of optical constants. Thus the observed heliocentric evolution of the 3.4-micrometers feature provides information on the composition, and perhaps structure, of the organic grains in Comet Halley. In addition, we argue that the heliocentric evolution of organic features will differ in the cases of thermal emission from small grains and gas-phase fluorescence. Therefore observations of cometary spectral evolution can in principle distinguish between solid or gas-phase origins for these features.


Assuntos
Meteoroides , Modelos Teóricos , Espectrofotometria Infravermelho , Poeira Cósmica/análise , Fluorescência , Hidrocarbonetos/análise , Gelo/análise , Tamanho da Partícula , Astronave
17.
Appl Opt ; 32(12): 2117-21, 1993 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-20820356

RESUMO

A novel tunable diode laser spectrometer operating at 8 < lambda < 28 microm is described. A blocked impurity band Si:As chip is employed as detector. This device operates in this wavelength range with high detectivity and adequate frequency response for the high-sensitivity techniques used. A combination of sweep averaging and second-harmonic detection at 22 kHz yielded signal-to-noise ratios of 1200 at lambda > 20 microm. The sensitivity and spectral resolution achieved are 1 order of magnitude better than those of Fourier instruments in this range, with an improvement in instrument time response of ~ 3000. Several molecular bands of CO(2) and N(2)O are observed for what is, to our knowledge, the first time with this instrument. Examples of spectral line measurements are presented.

18.
Appl Opt ; 15(2): 427-36, 1976 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-20164986

RESUMO

The sensitivity of an ideal heterodyne spectrometer approaches the quantum detection limit provided the local oscillator power is sufficiently large and the shot noise dominates all other sources of noise. The postintegration minimum-detectable-number of photons/sec for an ideal heterodyne system is (B/tau)((1/2)), where B is the IF bandwidth, and tau is the integration time. For astronomical observations, however, a number of factors (Delta(i)) tend to degrade the sensitivity, a fact that becomes significant particularly when the laser power is insufficient. A discussion and an evaluation of the degradation in sensitivity are given for a heterodyne spectrometer employing a HgCdTe photodiode mixer and tunable diode lasers. The minimum detectable source brightness is considered as a function of the mixer parameters, transmission coefficient of the beam splitter, and local oscillator emission powers. The degradation in the minimum detectable line source brightness that results from the bandwidth being a fraction of the line width is evaluated and plotted as a function of the wavelength and bandwidth for various temperature to mass ratios. It is shown that the minimum achievable degradation [pi(i)(Delta(i))] in the sensitivity of a practical astronomical heterodyne spectrometer is ~30. Estimates of SNR's with which ir line emission from astronomical sources of interest may be detected are given.

19.
Appl Opt ; 21(2): 253-9, 1982 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-20372438

RESUMO

A diode-laser based ultrahigh resolution IR heterodyne spectrometer for laboratory and field use has been developed for operation between 7.5 and 8.5 microm. The local oscillator is a PbSe tunable diode laser kept continuously at operating temperatures of 12-60 K using a closed-cycle cooler. The laser output frequency is controlled and stabilized using a high-precision diode current supply, constant temperature controller, and a shock isolator mounted between the refrigerator cold tip and the diode mount. The system largely employs reflecting optics to minimize losses from internal reflection and absorption and to eliminate chromatic effects. Spectral analysis of the diode-laser output between 0 and 1 GHz reveals excess noise at many diode current settings, which limits the IR spectral regions over which useful heterodyne operation can be achieved. Observations have been made of atmospheric N(2)O, O(3), and CH(4) between 1170 and 1200 cm(-1) using both a single-frequency swept IF channel and a 64-channel rf spectral line receiver with a total IF coverage of 1600 MHz.

20.
J Electrocardiol ; 23 Suppl: 164-8, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2090737

RESUMO

Rapid ventricular tachycardia is poorly tolerated, and estimation of maximum ventricular tachycardia rate prior to programmed ventricular stimulation is difficult. A method to estimate maximum ventricular tachycardia rate using late potential duration from the signal-averaged ECG and ventricular functional refractory period is described. Late potentials recorded in patients with ventricular tachycardia may represent delayed conduction through arrhythmogenic ventricular myocardium. This delay may be rate limiting in determining the minimum cycle length of reentrant ventricular tachycardia originating from these areas. Using the ratio of ventricular activation time (VAT), which equals QRS plus late potential duration, to unfiltered QRS duration (QRS) as estimate of this delay, the following relationship is proposed: Minimum ventricular tachycardia cycle length = (FRP 400 - 12.5 ms) (VAT/QRS). Twenty patients with late potentials who had sustained, monomorphic ventricular tachycardia at programmed stimulation were evaluated. Predicted cycle lengths ranged from 326 to 214 ms. Predicted and observed cycle lengths were significantly correlated (r = 0.91, SEE = 11.9 ms, p less than 0.0005), with predicted and observed cycle lengths differing by less than 3.5%. Predicted cycle lengths were more accurate than cycle lengths estimated using FRP alone (p less than 0.01). Accurate prediction of minimum ventricular tachycardia cycle length using this relationship suggests that late potential duration is proportional to the conduction delay occurring in arrhythmogenic ventricular myocardium.


Assuntos
Estimulação Cardíaca Artificial , Eletrocardiografia/métodos , Processamento de Sinais Assistido por Computador , Taquicardia/diagnóstico , Doença das Coronárias/diagnóstico , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA