Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Eur Radiol ; 30(6): 3188-3197, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32060711

RESUMO

OBJECTIVES: When increasing the PET acquisition time to match the longer MRI protocol in simultaneous PET/MR, the injected PET tracer dose can possibly be lowered to reduce radiation exposure. Moreover, applying new commercially available time-of-flight (TOF) block sequential regularized expectation maximization (BSREM)-based reconstruction algorithms could allow for further dose reductions. The purpose of this study was to find the minimal dose of the tracer targeting the prostate specific membrane antigen (68Ga-PSMA-11) for a dedicated 15-min pelvic PET/MR scan that still matches the image quality of a reference 3-min scan at 100% (150 MBq) dose. METHODS: In this retrospective analysis, 25 patients were included. PET emission datasets were edited to simulate stepwise reductions of injected tracer dose. Reference TOF ordered subset expectation maximum (OSEM) and new TOF BSREM reconstructions were performed and differences in the resulting PET images were visually and quantitatively assessed. RESULTS: Visually, TOF BSREM reconstructions with relatively high regularization parameter (ß) values are preferred. Quantitatively, however, high ß-values result in lower lesion maximum standardized uptake values (SUVmax) compared to the reference. A ß-value of 550 was considered the optimal compromise for the lowest possible 10% dose reconstructions, resulting in comparable visual assessment and lesion SUVmax. CONCLUSIONS: This study indicates that the injected 68Ga-PSMA-11 tracer dose for a standard 3-min PET scan can be reduced to approximately 10% (15 MBq) when the PET acquisition time is matched to the 15-min pelvic MRI protocol, and when reconstructed with TOF BSREM using ß = 550. This decreases the effective dose from 3.54 to 0.35 mSv. KEY POINTS: • Low-dose dedicated pelvic68Ga-PSMA-11 PET/MR reduces radiation exposure for patients. • Retrospective study investigating the minimal dose needed for adequate image quality for 15-min PET frames over the pelvis showed using quantitative and qualitative analysis that a substantial dose reduction is possible without significant loss of image quality when using the TOF BSREM reconstruction algorithm. • With the introduction of low-dose pelvic68Ga-PSMA-11 PET/MR, new potential applications of68Ga-PSMA-11 PET for local staging or investigation of equivocal MRI findings could become applicable, even for patients without confirmed prostate cancer.


Assuntos
Radioisótopos de Gálio/administração & dosagem , Glicoproteínas de Membrana/administração & dosagem , Compostos Organometálicos/administração & dosagem , Pelve/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Próstata/diagnóstico por imagem , Idoso , Algoritmos , Antígenos de Superfície , Isótopos de Gálio , Glutamato Carboxipeptidase II , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/diagnóstico por imagem , Doses de Radiação , Estudos Retrospectivos
2.
Eur J Nucl Med Mol Imaging ; 45(1): 20-30, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29032394

RESUMO

PURPOSE: Sensitive visualization of recurrent prostate cancer foci is a challenge in patients with early biochemical recurrence (EBR). The recently established 68Ga-PSMA-11 PET/CT has significantly improved the detection rate with published values of up to 55% for patients with a serum PSA concentration between 0.2-0.5 ng/mL. The increased soft tissue contrast in the pelvis using simultaneous 68Ga-PSMA-11 PET/MRI might further improve the detection rate in patients with EBR and low PSA values over PET/CT. METHODS: We retrospectively analyzed a cohort of 56 consecutive patients who underwent a 68Ga-PSMA-11 PET/MRI for biochemical recurrence in our institution between April and December 2016 with three readers. Median PSA level was 0.99 ng/mL (interquartile range: 3.1 ng/mL). Detection of PSMA-positive lesions within the prostate fossa, local and distant lymph nodes, bones, or visceral organs was recorded. Agreement among observers was evaluated with Fleiss's kappa (k). RESULTS: Overall, in 44 of 56 patients (78.6%) PSMA-positive lesions were detected. In four of nine patients (44.4%) with a PSA < 0.2 ng/mL, suspicious lesions were detected (two pelvic and one paraaortic lymph nodes, and two bone metastases). In eight of 11 patients (72.7%) with a PSA between 0.2 and < 0.5 ng/mL, suspicious lesions were detected (two local recurrences, six lymph nodes, and one bone metastasis). Five out of 20 patients with a PSA < 0.5 ng/mL had extrapelvic disease. In 12 of 15 patients (80.0%) with a PSA between 0.5 and < 2.0 ng/mL, suspicious lesions were detected (four local recurrences, nine lymph nodes, and four bone metastases). In 20 of 21 patients (95.2%) with a PSA >2.0 ng/mL, suspicious lesions were detected. The overall interreader agreement for cancer detection was excellent (κ = 0.796, CI 0.645-0.947). CONCLUSIONS: Our data show that 68Ga-PSMA-11 PET/MRI has a high detection rate for recurrent prostate cancer even at very low PSA levels <0.5 ng/mL. Furthermore, even at those low levels extrapelvic disease can be localized in 25% of the cases and local recurrence alone is seen only in 10%.


Assuntos
Ácido Edético/análogos & derivados , Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Oligopeptídeos , Tomografia por Emissão de Pósitrons/métodos , Neoplasias da Próstata/diagnóstico por imagem , Compostos Radiofarmacêuticos , Idoso , Idoso de 80 Anos ou mais , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/métodos , Imagem Multimodal/normas , Recidiva Local de Neoplasia/patologia , Tomografia por Emissão de Pósitrons/normas , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia
3.
Eur J Nucl Med Mol Imaging ; 45(8): 1335-1343, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29523924

RESUMO

PURPOSE: Given the good correlation between PSMA expression and intraglandular tumour aggressiveness based on immunohistochemistry, there is increasing interest in 68Ga-PSMA-11 PET/MRI for staging prostate cancer (PCA). Therefore, accurate knowledge of prostate anatomy as well as normal distribution of PSMA within the prostate gland is becoming essential. The aim of this study was to investigate the physiological intraprostatic distribution of 68Ga-PSMA-11. METHODS: We retrospectively analysed all patients who underwent a staging 68Ga-PSMA-11 PET/MRI scan between June 2016 and January 2018 for high-risk PCA, underwent radical prostatectomy in our institution, and gave written consent for further data analysis. In each patient, standardized volumes of interest (VOIs) were placed bilaterally in the central, transition and peripheral zones within the zonal anatomy according to T2 weighted sequences in the axial and coronal planes. VOIs were only placed if they were safely within healthy tissue without spillover from the PCA. SUVmax and SUVmean were determined and their differences among the regions were assessed using the Wilcoxon signed-ranks test. RESULTS: Of 283 consecutive patients scanned with 68Ga-PSMA-11 PET/MR, 31 were analysed. A total of 133 VOIs were placed, 46 in the central zone, 41 in the transition zone and 46 in the peripheral zone. Differences in SUVmax between the central zone (mean 3.9 ± 0.58) and transition zone (mean 3.2 ± 0.59) and between the central zone and peripheral zone (mean 2.7 ± 0.54) were statistically significant (both p < 0.001). CONCLUSION: Our results suggest that higher 68Ga-PSMA-11 accumulation in the central zone than in the transition and peripheral zones is normal, and leads to a pattern resembling "Mickey Mouse ears" on 68Ga-PSMA-11 PET. This pattern could be helpful in avoiding false-positive interpretations of PET scans.


Assuntos
Ácido Edético/análogos & derivados , Oligopeptídeos/farmacocinética , Neoplasias da Próstata/diagnóstico por imagem , Ácido Edético/farmacocinética , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Antígeno Prostático Específico , Prostatectomia , Neoplasias da Próstata/cirurgia , Estudos Retrospectivos
4.
Oncologist ; 22(6): 749-753, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28559410

RESUMO

Checkpoint inhibitors are increasingly being used in the treatment of malignant melanoma and other cancers. With the use of such therapies, autoimmune-mediated adverse events in the central and peripheral nervous system are likely to occur more frequently. We report a unique case of brainstem encephalitis with a sudden lethal outcome following ipilimumab and pembrolizumab therapy in a patient with malignant melanoma. The autopsy showed a diffuse nodular activation of microglia in the whole encephalon with prominent intraparenchymal and perivascular lymphocytic infiltration of the brainstem. Non-infectious brainstem encephalitis is a well-recognized subset of paraneoplastic encephalitis. Brainstem involvement is usually accompanied by a wide spectrum of signs and symptoms, which were not observed in this case. The timing of the clinical symptoms as well as the histopathological findings suggest an autoimmune-adverse event of ipilimumab and pembrolizumab administration rather than a paraneoplastic disorder. In the presence of neurological symptoms, immediate cessation of the immunotherapy and immunosuppressive therapy may lead to successful therapeutic intervention, as described in previous reports. Therefore, it is crucial that physicians are aware of the possible side effects of immunotherapies on the nervous system. IMPLICATIONS FOR PRACTICE: Metastatic melanoma patients treated with the anti-CTLA-4 inhibitor ipilimumab have a high utilization of various types of health care services, such as inpatient hospital stays or doctor visits. There are differences across countries regarding patterns of health care utilization and economic burden of the disease. Health care services are used more frequently after patients experience progression of their disease. The study highlights that better therapies leading to durable response in patients with metastatic melanoma have the potential to decrease health care costs and patient burden in terms of hospitalizations and other health care services.


Assuntos
Anticorpos Monoclonais/efeitos adversos , Encefalite/fisiopatologia , Ipilimumab/efeitos adversos , Melanoma/tratamento farmacológico , Anticorpos Monoclonais/administração & dosagem , Tronco Encefálico/efeitos dos fármacos , Tronco Encefálico/patologia , Encefalite/induzido quimicamente , Feminino , Humanos , Imunoterapia , Ipilimumab/administração & dosagem , Melanoma/complicações , Melanoma/patologia , Pessoa de Meia-Idade
5.
PLoS One ; 15(10): e0239990, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33031379

RESUMO

BACKGROUND: Brown adipose tissue (BAT) is a specialized form of adipose tissue, able to increase energy expenditure by heat generation in response to various stimuli. Recently, its pathological activation has been implicated in the pathogenesis of cancer cachexia. To establish a causal relationship, we retrospectively investigated the longitudinal changes in BAT and cancer in a large FDG-PET/CT cohort. METHODS: We retrospectively analyzed 13 461 FDG-PET/CT examinations of n = 8 409 patients at our institution from the winter months of 2007-2015. We graded the activation strength of BAT based on the anatomical location of the most caudally activated BAT depot into three tiers, and the stage of the cancer into five general grades. We validated the cancer grading by an interreader analysis and correlation with histopathological stage. Ambient temperature data (seven-day average before the examination) was obtained from a meteorological station close to the hospital. Changes of BAT, cancer, body mass index (BMI) and temperature between the different examinations were examined with Spearman's test and a mixed linear model for correlation, and with a causal inference algorithm for causality. RESULTS: We found n = 283 patients with at least two examinations and active BAT in at least one of them. There was no significant interaction between the changes in BAT activation, cancer burden or BMI. Temperature changes exhibited a strong negative correlation with BAT activity (ϱ = -0.57, p<0.00001). These results were confirmed with the mixed linear model. Causal inference revealed a link of Temperature ➜ BAT in all subjects and also of BMI ➜ BAT in subjects who had lost weight and increased cancer burden, but no role of cancer and no causal links of BAT ➜ BMI. CONCLUSIONS: Our data did not confirm the hypothesis that BAT plays a major role in cancer-mediated weight loss. Temperature changes are the main driver of incidental BAT activity on FDG-PET scans.


Assuntos
Tecido Adiposo Marrom/metabolismo , Neoplasias/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tecido Adiposo Marrom/diagnóstico por imagem , Adulto , Idoso , Índice de Massa Corporal , Temperatura Corporal , Caquexia , Estudos de Coortes , Feminino , Fluordesoxiglucose F18/química , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Neoplasias/diagnóstico por imagem , Estudos Retrospectivos
6.
EJNMMI Res ; 8(1): 70, 2018 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-30054750

RESUMO

BACKGROUND: In contrast to ordered subset expectation maximization (OSEM), block sequential regularized expectation maximization (BSREM) positron emission tomography (PET) reconstruction algorithms can run until full convergence while controlling image quality and noise. Recent studies with BSREM and 18F-FDG PET reported higher signal-to-noise ratios and higher standardized uptake values (SUV). In this study, we investigate the optimal regularization parameter (ß) for clinical 68Ga-PSMA PET/MR reconstructions in the pelvic region applying time-of-flight (TOF) BSREM in comparison to TOF OSEM. Two-minute emission data from the pelvic region of 25 patients who underwent 68Ga-PSMA PET/MR were retrospectively reconstructed. Reference OSEM reconstructions had 28 subsets and 2 iterations. BSREM reconstructions were performed with 15 ß values between 150 and 1200. Regions of interest (ROIs) were drawn around lesions and in uniform background. Background SUVmean (average) and SUVstd (standard deviation), and lesion SUVmax (average of 5 hottest voxels) were calculated. Differences were analyzed using the Wilcoxon matched pairs signed-rank test. RESULTS: A total of 40 lesions were identified in the pelvic region. Background noise (SUVstd) and lesions SUVmax decreased with increasing ß. Image reconstructions with ß values lower than 400 have higher (p < 0.01) background noise, compared to the reference OSEM reconstructions, and are therefore less useful. Lesions with low activity on images reconstructed with ß values higher than 600 have a lower (p < 0.05) SUVmax compared to the reference. These reconstructions are likely visually appealing due to the lower background noise, but the lower SUVmax could possibly render small low-uptake lesions invisible. CONCLUSIONS: In our study, we showed that PET images reconstructed with TOF BSREM in combination with the 68Ga-PSMA tracer result in lower background noise and higher SUVmax values in lesions compared to TOF OSEM. Our study indicates that a ß value between 400 and 550 might be the optimal compromise between high SUVmax and low background noise.

7.
EJNMMI Res ; 8(1): 68, 2018 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-30054768

RESUMO

Unfortunately, after publication of this article [1], it was noticed that the name of Urs J. Muehlematter was incorrectly displayed as Urs J. Mühlematter. The corrected author list can be seen above and the original article has been corrected to reflect this.

8.
EJNMMI Res ; 8(1): 41, 2018 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-29855728

RESUMO

BACKGROUND: Accurate attenuation correction (AC) is an inherent problem of positron emission tomography magnetic resonance imaging (PET/MRI) systems. Simulation studies showed that time-of-flight (TOF) detectors can reduce PET quantification errors in MRI-based AC. However, its impact on lesion detection in a clinical setting with 18F-choline has not yet been evaluated. Therefore, we compared TOF and non-TOF 18F-choline PET for absolute and relative difference in standard uptake values (SUV) and investigated the detection rate of metastases in prostate cancer patients. RESULTS: Non-TOF SUV was significantly lower compared to TOF in all osseous structures, except the skull, in primary lesions of the prostate, and in pelvic nodal and osseous metastasis. Concerning lymph node metastases, both experienced readers detected 16/19 (84%) on TOF PET, whereas on non-TOF PET readers 1 and 2 detected 11 (58%), and 14 (73%), respectively. With TOF PET readers 1 and 2 detected 14/15 (93%) and 11/15 (73%) bone metastases, respectively, whereas detection rate with non-TOF PET was 73% (11/15) for reader 1 and 53% (8/15) for reader 2. The interreader agreement was good for osseous metastasis detection on TOF (kappa 0.636, 95% confidence interval [CI] 0.453-0.810) and moderate on non-TOF (kappa = 0.600, CI 0.438-0.780). CONCLUSION: TOF reconstruction for 18F-choline PET/MRI shows higher SUV measurements compared to non-TOF reconstructions in physiological osseous structures as well as pelvic malignancies. Our results suggest that addition of TOF information has a positive impact on lesion detection rate for lymph node and bone metastasis in prostate cancer patients.

9.
Eur J Radiol ; 91: 41-46, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28629569

RESUMO

PURPOSE: To evaluate the interreader agreement of a three-tier craniocaudal grading system for brown fat activation and investigate the accuracy of the distinction between the three grades. MATERIALS AND METHODS: After IRB approval, 340 cases were retrospectively selected from patients undergoing (18)FDG-PET/CT between 2007 and 2015 at our institution, with 85 cases in each grade and 85 controls with no active brown fat. Three readers evaluated all cases independently. Furthermore standardized uptake values (SUV) measurements were performed by two readers in a subset of 53 cases. Agreement between the readers was assessed with Cohen's Kappa (k), the concordance correlation coefficient (CCC) and the intraclass correlation coefficient (ICC). Accuracy was assessed with Bland-Altman and receiver operating characteristics (ROC) analysis. A Bonferroni-corrected two-tailed p<0.016 was considered statistically significant. RESULTS: Agreement for BAT grade was excellent by all three metrics with k=0.83-0.89, CCC=0.83-0.89 and ICC=0.91-0.94. Bland-Altman analysis revealed only slight average over- or underestimation (-0.01-0.14) with the majority of disagreements within one grade. ROC analysis yielded slightly less accurate classification between higher vs. lower grades (Area under the ROC curves 0.78-0.84 vs. 0.88-0.92) but no significant differences between readers. Agreement was also excellent for the maximum SUV and the total brown fat volume (k=0.90 and 0.94, CCC=0.93 and 0.99, ICC=0.96 and 0.99), but Bland-Altman plots revealed a tendency to underestimate activity by one of the readers. CONCLUSION: Grading the activation of brown fat by assessment of the most caudally activated depots results in excellent interreader agreement, comparable to SUV measurements.


Assuntos
Tecido Adiposo Marrom/diagnóstico por imagem , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos
10.
Phys Rev E ; 93(5): 052112, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27300835

RESUMO

Driven diffusive systems such as the zero-range process (ZRP) and the pair-factorized steady states (PFSS) stochastic transport process are versatile tools that lend themselves to the study of transport phenomena on a generic level. While their mathematical structure is simple enough to allow significant analytical treatment, they offer a variety of interesting phenomena. With appropriate dynamics, the ZRP and PFSS models feature a condensation transition where, for a supercritical density, the translational symmetry breaks spontaneously and excess particles form a single-site or spatially extended condensate, respectively. In this paper we numerically study the typical time scales of the two stages of this condensation process: Nucleation and coarsening. Nucleation is the first stage of condensation where the bulk system relaxes to its stationary distribution and droplet nuclei form in the system. These droplets then gradually grow or evaporate in the coarsening regime to coalesce in a single condensate when the system finally relaxes to the stationary state. We use the ZRP condensation model to discuss the choice of the estimation method for the nucleation time scale and present scaling exponents for the ZRP and PFSS condensation models with respect to the choice of the typical droplet nuclei mass. We then proceed to present scaling exponents in the coarsening regime of the ZRP for partially asymmetric dynamics and the PFSS model for symmetric and asymmetric dynamics.

11.
PLoS One ; 11(2): e0149458, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26901352

RESUMO

BACKGROUND: Recent advances in obesity research suggest that BAT activity, or absence thereof, may be an important factor in the growing epidemic of obesity and its manifold complications. It is thus important to assess larger populations for BAT-activating and deactivating factors. 18FDG-PET/CT is the standard method to detect and quantify metabolic BAT activity, however, the manual measurement is not suitable for large studies due to its time-consuming nature and poor reproducibility across different software and devices. METHODOLOGY/MAIN FINDINGS: In a retrospective study, 1060 consecutive scans of 1031 patients receiving a diagnostic 18FDG-PET/CT were examined for the presence of active BAT. Patients were classified according to a 3-tier system (supraclavicular, mediastinal, infradiaphragmatic) depending on the anatomical location of their active BAT depots, with the most caudal location being the decisive factor. The metabolic parameters (maximum activity, total volume and total glycolysis) were measured on a standard PET/CT workstation. Mean age of the population was 60±14.6y. 41.61% of patients were female. Metabolically active BAT was found in 53 patients (5.1%). Female, younger and leaner patients tended to have more active BAT, higher metabolic activity and more caudally active BAT. In total, 15 patients showed only supraclavicular, 27 additional mediastinal, and 11 infradiaphragmal activity. Interestingly, the activation of BAT always followed a cranio-caudal gradient. This anatomical pattern correlated with age and BMI as well as with all metabolic parameters, including maximum and total glycolysis (p<0.001). CONCLUSION: Based on our data we propose a simple method to grade or quantify the degree of BAT amount/activity in patients based on the most caudally activated depot. As new modalities for BAT visualization may arise in the future, this system would allow direct comparability with other modalities, in contrary to the PET-metrics, which are restricted to 18FDG-PET/CT.


Assuntos
Tecido Adiposo Marrom/diagnóstico por imagem , Tecido Adiposo Marrom/metabolismo , Glucose-6-Fosfato/análogos & derivados , Obesidade/diagnóstico por imagem , Obesidade/mortalidade , Tomografia por Emissão de Pósitrons , Adulto , Idoso , Feminino , Glucose-6-Fosfato/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia
12.
Artigo em Inglês | MEDLINE | ID: mdl-23848714

RESUMO

From a coarse-grained perspective, the motif of a self-activating species, activating a second species that acts as its own repressor, is widely found in biological systems, in particular in genetic systems with inherent oscillatory behavior. Here we consider a specific realization of this motif as a genetic circuit, termed the bistable frustrated unit, in which genes are described as directly producing proteins. Upon an improved resolution in time, we focus on the effect that inherent time scales on the underlying scale can have on the bifurcation patterns on a coarser scale. Time scales are set by the binding and unbinding rates of the transcription factors to the promoter regions of the genes. Depending on the ratio of these rates to the decay times of both proteins, the appropriate averaging procedure for obtaining a coarse-grained description changes and leads to sets of deterministic equations, which considerably differ in their bifurcation structure. In particular, the desired intermediate range of regular limit cycles fades away when the binding rates of genes are not fast as compared to the decay time of the proteins. Our analysis illustrates that the common topology of the widely found motif alone does not imply universal features in the dynamics.


Assuntos
Relógios Biológicos/genética , Redes Reguladoras de Genes/genética , Modelos Genéticos , Motivos de Nucleotídeos/genética , Fatores de Transcrição/genética , Ativação Transcricional/genética , Simulação por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA