Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 119(20): 205001, 2017 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-29219375

RESUMO

The propagation dynamics of resonant magnetic perturbation fields in KSTAR H-mode plasmas with injection of small edge perturbations produced by a supersonic molecular beam injection is reported for the first time. The results show that the perturbation field first excites a plasma response on the q=3 magnetic surface and then propagates inward to the q=2 surface with a radially averaged propagation velocity of resonant magnetic perturbations field equal to 32.5 m/ s. As a result, the perturbation field brakes the toroidal rotation on the q=3 surface first causing a momentum transport perturbation that propagates both inward and outward. A higher density fluctuation level is observed. The propagation velocity of the resonant magnetic perturbations field is larger than the radial propagation velocity of the perturbation in the toroidal rotation.

2.
Phys Rev Lett ; 109(3): 035004, 2012 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-22861864

RESUMO

Edge localized modes (ELMs) in high-confinement mode plasmas were completely suppressed in KSTAR by applying n=1 nonaxisymmetric magnetic perturbations. Initially, the ELMs were intensified with a reduction of frequency, but completely suppressed later. The electron density had an initial 10% decrease followed by a gradual increase as ELMs were suppressed. Interesting phenomena such as a saturated evolution of edge T(e) and broadband changes of magnetic fluctuations were observed, suggesting the change of edge transport by the applied magnetic perturbations.

3.
Rev Sci Instrum ; 92(4): 043559, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243393

RESUMO

Major parts of an IR-visible two-color interferometer (TCI) on KSTAR have been upgraded for the multi-chord operation: (1) a diode-pumped-solid-state (DPSS) laser (660 nm) replacing the former HeNe laser (633 nm), (2) vacuum-compatible vibration isolator with titanium retro-reflectors, and (3) full digital phase comparator for multi-chord real-time density signals. The commercial compact DPSS laser suits the multiple chord configuration with its strong beam power (500 mW) and long coherent length (>100 m). Ti retro-reflectors are mounted on vacuum-compatible vibration isolators. The isolators are essential for the visible beams to avoid any fringe skips due to their short wavelength, considering the speed of the mechanical vibration (up to hundreds of µm). Field-programmable-gate-array (FPGA) modules count the entire fringes fast enough with a signal output rate up to 1.25 MHz, solving the fringe skip issues. The FPGA module enables the full digital processing of the phase comparator with a CORDIC algorithm after the sampling rate of 160 MS/s for the 40 MHz intermediate frequency of each beam. The full digital signals are transferred to the main plasma control system in real-time. Stable single-input-single-output operation of the KSTAR density control was demonstrated with the TCI. The real-time density profile control is also promising in the near future, with multiple actuators such as pellets and gas puffings.

4.
Rev Sci Instrum ; 92(4): 043504, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243446

RESUMO

A fast-ion Dα (FIDA) diagnostics system was installed for core and edge measurements on KSTAR. This system has two tangential FIDA arrays that cover both blue- and redshifted Dα lines (cold: 656.09 nm) in active views along the neutral beam 1 A centerline. The spectral band is 647-662.5 nm, and it covers the Doppler shift of the emission from the maximum energy of the neutral beam (100 keV). A curved filter strip with a motorized stage adequately prevents saturation of the electron multiplying charge-coupled device signal by the cold Dα line from the plasma edge. From comparisons of the measured spectra and FIDASIM modeling code, the FIDA spectra are well matched quantitatively. Moreover, the first measurements show that the FIDA radiance agrees with the neutron rate in the time trace during external heating and perturbation. In addition, responses are observed in the core FIDA radiance during the edge-localized mode cycle.

5.
Rev Sci Instrum ; 89(10): 10B111, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399651

RESUMO

A fringe jump compensation algorithm has been developed for a phase measurement that measures the phase within a single fringe. The algorithm is extremely useful in the case of the time-averaging zero-crossing phase detector on noisy environments. When the noise level on the measurements is not sufficiently suppressed, the signals near the fringe jump show a negative slope instead of a sharp drop. The slope brings an ambiguity over the compensation process. An algorithm with an additional channel that measures the phase of a half fringe shift has been applied in the millimeter-wave interferometer on the Korea Superconducting Tokamak Advanced Research device. These techniques removed the ambiguity in most cases. The algorithm can provide a most simple, robust, and cost-effective solution for the phase measurement system in various fields.

6.
Rev Sci Instrum ; 89(1): 013503, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29390651

RESUMO

A 60 keV neutral lithium beam system was designed and built up for beam emission spectroscopy measurement of edge plasma on the KSTAR and EAST tokamaks. The electron density profile and its fluctuation can be measured using the accelerated lithium beam-based emission spectroscopy system. A thermionic ion source was developed with a SiC heater to emit around 4-5 mA ion current from a 14 mm diameter surface. The ion optic is following the 2 step design used on other devices with small modifications to reach about 2-3 cm beam diameter in the plasma at about 4 m from the ion source. A newly developed recirculating sodium vapour neutralizer neutralizes the accelerated ion beam at around 260-280 °C even during long (<20 s) discharges. A set of new beam diagnostic and manipulation techniques are applied to allow optimization, aiming, cleaning, and beam modulation. The maximum 60 keV beam energy with 4 mA ion current was successfully reached at KSTAR and at EAST. Combined with an efficient observation system, the Li-beam diagnostic enables the measurement of the density profile and fluctuations on the plasma turbulence time scale.

7.
Rev Sci Instrum ; 87(4): 043501, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-27131668

RESUMO

The design characteristics of a multi-channel collective (or coherent) scattering system for small scale turbulence study in Korea Superconducting Tokamak Advanced Research (KSTAR), which is planned to be installed in 2017, are given in this paper. A few critical issues are discussed in depth such as the Faraday and Cotton-Mouton effects on the beam polarization, radial spatial resolution, probe beam frequency, polarization, and power. A proper and feasible optics with the 300 GHz probe beam, which was designed based on these issues, provides a simultaneous measurement of electron density fluctuations at four discrete poloidal wavenumbers up to 24 cm(-1). The upper limit corresponds to the normalized wavenumber kθρe of ∼0.15 in nominal KSTAR plasmas. To detect the scattered beam power and extract phase information, a quadrature detection system consisting of four-channel antenna/detector array and electronics will be employed.

8.
Rev Sci Instrum ; 87(11): 11E131, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910476

RESUMO

The 2015 KSTAR experimental campaign was the first year of routine measurement with a far infrared interferometer (FIRI) utilizing 118.87 µm CH3OH lasers at maximum 200 mW CW beam power. By using rtEFIT reconstruction, the path lengths of interferometers can be calculated and so the line-averaged electron densities n¯e from the FIRI and a millimeter-wave interferometer were in excellent agreement. In this way, the number of successfully diagnosed discharges is counted: 1003 shots or 83.7% of sustained discharges, defined as shots of plasma current IP ≥ 0.3 MA with pulse lengths tf ≥ 2.0 s, have good-quality FIRI data within a few fringe jump errors. In addition, real-time H-mode density feedback control based on the FIRI was also successfully achieved with supersonic molecular beam injection as an actuator. Both constant density and controlled linear increment with a ramp-up rate of 1.0 × 1019 m-3 s-1 were achieved.

9.
Rev Sci Instrum ; 86(7): 073501, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26233377

RESUMO

A novel beam emission spectroscopy observation system was designed, built, and installed onto the Korea Superconducting Tokamak Advanced Research tokamak. The system is designed in a way to be capable of measuring beam emission either from a heating deuterium or from a diagnostic lithium beam. The two beams have somewhat complementary capabilities: edge density profile and turbulence measurement with the lithium beam and two dimensional turbulence measurement with the heating beam. Two detectors can be used in parallel: a CMOS camera provides overview of the scene and lithium beam light intensity distribution at maximum few hundred Hz frame rate, while a 4 × 16 pixel avalanche photo-diode (APD) camera gives 500 kHz bandwidth data from a 4 cm × 16 cm region. The optics use direct imaging through lenses and mirrors from the observation window to the detectors, thus avoid the use of costly and inflexible fiber guides. Remotely controlled mechanisms allow adjustment of the APD camera's measurement location on a shot-to-shot basis, while temperature stabilized filter holders provide selection of either the Doppler shifted deuterium alpha or lithium resonance line. The capabilities of the system are illustrated by measurements of basic plasma turbulence properties.

10.
Rev Sci Instrum ; 85(11): 11D858, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430271

RESUMO

A Doppler reflectometer has been designed to measure the poloidal propagation velocity on the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak. It has the operating frequency range of V-band (50-75 GHz) and the monostatic antenna configuration with extraordinary mode (X-mode). The single sideband modulation with an intermediate frequency of 50 MHz is used for the heterodyne measurement with the 200 MHz in-phase and quadrature (I/Q) phase detector. The corrugated conical horn antenna is used to approximate the Gaussian beam propagation and it is installed together with the oversized rectangular waveguides in the vacuum vessel. The first commissioning test of the Doppler reflectometer system on the KSTAR tokamak is planned in the 2014 KSTAR experimental campaign.

11.
Rev Sci Instrum ; 85(11): 11E434, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430341

RESUMO

Beam emission spectroscopy (BES) system in Korea Superconducting Tokamak Advanced Research (KSTAR) has recently been upgraded. The background intensity was reduced from 30% to 2% by suppressing the stray lights. This allows acquisition of the relative electron density profiles on the plasma edge without background subtraction from the beam power modulation signals. The KSTAR BES system has its spatial resolution of 1 cm, the temporal resolution of 2 MHz, and a total 32 channel (8 radial × 4 poloidal) avalanche photo diode array. Most measurements were done on the plasma edge, r/a ∼ 0.9, with 8 cm radial measurement width that covers the pedestal range. High speed density profile measurements reveal temporal behaviors of fast transient events, such as the precursors of edge localized modes and the transitions between confinement modes. Low background level also allows analysis of the edge density fluctuation patterns with reduced background fluctuations. Propagation of the density structures can be investigated by comparing the phase delays between the spatially distributed channels.

12.
Rev Sci Instrum ; 83(10): 10D531, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126870

RESUMO

A beam emission spectroscopy (BES) system based on direct imaging avalanche photodiode (APD) camera has been designed for Korea Superconducting Tokamak Advanced Research (KSTAR) and a trial system has been constructed and installed for evaluating feasibility of the design. The system contains two cameras, one is an APD camera for BES measurement and another is a fast visible camera for position calibration. Two pneumatically actuated mirrors were positioned at front and rear of lens optics. The front mirror can switch the measurement between edge and core region of plasma and the rear mirror can switch between the APD and the visible camera. All systems worked properly and the measured photon flux was reasonable as expected from the simulation. While the measurement data from the trial system were limited, it revealed some interesting characteristics of KSTAR plasma suggesting future research works with fully installed BES system. The analysis result and the development plan will be presented in this paper.

13.
Rev Sci Instrum ; 83(11): 113501, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23206056

RESUMO

One of the main diagnostic tools for measuring electron density profiles and the characteristics of long wavelength turbulent wave structures in fusion plasmas is beam emission spectroscopy (BES). The increasing number of BES systems necessitated an accurate and comprehensive simulation of BES diagnostics, which in turn motivated the development of the Rate Equations for Neutral Alkali-beam TEchnique (RENATE) simulation code that is the topic of this paper. RENATE is a modular, fully three-dimensional code incorporating all key features of BES systems from the atomic physics to the observation, including an advanced modeling of the optics. Thus RENATE can be used both in the interpretation of measured signals and the development of new BES systems. The most important components of the code have been successfully benchmarked against other simulation codes. The primary results have been validated against experimental data from the KSTAR tokamak.

14.
Rev Sci Instrum ; 81(10): 10D510, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033865

RESUMO

A 280 GHz single-channel horizontal millimeter-wave interferometer system has been installed for plasma electron density measurements on the Korea Superconducting Tokamak Advanced Research (KSTAR) device. This system has a triangular beam path that does not pass through the plasma axis due to geometrical constraints in the superconducting tokamak. The term line density on KSTAR has a different meaning from the line density of other tokamaks. To estimate the peak density and the mean density from the measured line density, information on the position of the plasma is needed. The information has been calculated from tangentially viewed visible images using the toroidal symmetry of the plasma. Interface definition language routines have been developed for this purpose. The calculated plasma position data correspond well to calculation results from magnetic analysis. With the position data and an estimated plasma profile, the peak density and the mean density have been obtained from the line density. From these results, changes of plasma density themselves can be separated from effects of the plasma movements, so they can give valuable information on the plasma status.

15.
Rev Sci Instrum ; 81(9): 093505, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20886980

RESUMO

Images of plasma from a fast-framing camera are the most intuitive and reliable data to understand the status of tokamak plasmas. Generation, movement, size variation, and disruptions of plasmas can be clearly observed from these images. However, it is not a simple task to obtain the exact positions and sizes of plasmas using these images because measured two-dimensional images inevitably lose the three-dimensional position information of their targets. In this paper, the exact positions and sizes of plasmas have been calculated from tangentially viewed images using the toroidal symmetry of the plasma in the Korea Superconducting Tokamak Advanced Research (KSTAR) device. The positions and sizes of the plasmas have been manually determined with displayed cursors on images and automatically determined using a correlation factor with calculated virtual plasma images as well. These two results correspond well with each other. The estimated positions have also been compared with those obtained from magnetic diagnostics analysis.

16.
Rev Sci Instrum ; 81(10): 10E107, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033972

RESUMO

Within the scope of long term research on imaging diagnostics for steady-state plasmas and understanding of edge plasma physics through diagnostics with conventional spectroscopic methods, we have constructed a linear electron cyclotron resonance (ECR) plasma device named Research on Advanced Plasma Imaging and Dynamics (RAPID). It has a variety of axial magnetic field profiles provided by eight water-cooled magnetic coils and two dc power supplies. The positions of the magnetic coils are freely adjustable along the axial direction and the power supplies can be operated with many combinations of electrical wiring to the coils. Here, a 6 kW 2.45 GHz magnetron is used to produce steady-state hydrogen, helium, and argon plasmas with central magnetic fields of 875 and/or 437.5 G (second harmonic). In order to achieve the highest possible plasma performance within the limited input parameters, wall conditioning experiments were carried out. Chamber bake-out was achieved with heating coils that were wound covering the vessel, and long-pulse electron cyclotron heating discharge cleaning was also followed after 4 days of bake-out. A uniform bake-out temperature (150 °C) was achieved by wrapping the vessel in high temperature thermal insulation textile and by controlling the heating coil current using a digital control system. The partial pressure changes were observed using a residual gas analyzer, and a total system pressure of 5×10(-8) Torr was finally reached. Diagnostic systems including a millimeter-wave interferometer, a high resolution survey spectrometer, a Langmuir probe, and an ultrasoft x-ray detector were used to provide the evidence that the plasma performance was improved as we desired. In this work, we present characterization of the RAPID device for various system conditions and configurations.

17.
Rev Sci Instrum ; 81(6): 063502, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20590236

RESUMO

The first plasma with target values of the plasma current and the pulse duration was finally achieved on June 13, 2008 in the Korea Superconducting Tokamak Advanced Research (KSTAR). The diagnostic systems played an important role in achieving successful first plasma operation for the KSTAR tokamak. The employed plasma diagnostic systems for the KSTAR first plasma including the magnetic diagnostics, millimeter-wave interferometer, inspection illuminator, H(alpha), visible spectrometer, filterscope, and electron cyclotron emission (ECE) radiometer have provided the main plasma parameters, which are essential for the plasma generation, control, and physics understanding. Improvements to the first diagnostic systems and additional diagnostics including an x-ray imaging crystal spectrometer, reflectometer, ECE radiometer, resistive bolometer, and soft x-ray array are scheduled to be added for the next KSTAR experimental campaign in 2009.

18.
Rev Sci Instrum ; 80(10): 103503, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19895060

RESUMO

The research on advanced plasma imaging and dynamics (RAPID) device is a newly developed linear electron cyclotron resonance (ECR) plasma device. It has a variety of axial magnetic field profiles provided by eight water-cooled magnetic coils and two dc power supplies. The positions of the magnetic coils are freely adjustable along the axial direction and the power supplies can be operated with many combinations of electrical wiring to the coils. A 6 kW 2.45 GHz magnetron is used to produce steady-state ECR plasmas with central magnetic fields of 875 and/or 437.5 G (second harmonic). The cylindrical stainless steel vacuum chamber is 300 mm in diameter and 750 mm in length and has eight radial and ten axial ports including 6-in. and 8-in. viewing windows for heating and diagnostics. Experimental observation of ECR plasma heating has been recently carried out during the initial plasma operation. The main diagnostic systems including a 94 GHz heterodyne interferometer, a high-resolution 25 channel one-dimensional array spectrometer, a single channel survey spectrometer, and an electric probe have been also prepared. The RAPID device is a flexible simulator for the understanding of tokamak edge plasma physics and new diagnostic system development. In this work, we describe the RAPID device and initial operation results.

19.
Rev Sci Instrum ; 79(10): 10E705, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19044523

RESUMO

A 280 GHz single-channel horizontal millimeter-wave interferometer system has been fabricated and installed for plasma electron density measurements on the Korea Superconducting Tokamak Advanced Research (KSTAR). A retractable cassette system has been adopted for deep positioning of the interferometer system on large cryostat. The cassette system contains a pneumatic vacuum window shutter and a beam focusing module. The focusing module consists of antennas and aluminum concave mirrors, where an incident beam is reflected on a specially designed carbon inner-wall tile. The module enhances receiving beam power and reduces phase errors due to unexpected beam reflections on a vacuum vessel. Microwave components such as oscillators and mixers are located 2 m away from cryostat with a shielding box. Intermediate frequency signals generated by mixers are transmitted to a diagnostics room, and the phase difference between these signals is measured using a multifringe counting phase comparator. A beam path analysis has been performed for a triangular beam path geometry. An effective line-integrated density can be deduced from measured line-integrated density with these results. A beam path length error due to plasma refraction effect has been determined with various plasma conditions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA