Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Am J Vet Res ; 70(10): 1291-8, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19795945

RESUMO

OBJECTIVE: To evaluate exhaled N(2)O (eN(2)O), exhaled CO (eCO), and serum haptoglobin concentrations as diagnostic criteria for bovine respiratory disease (BRD) and determine whether a combination of biomarkers would be useful for predicting health outcomes of heifer calves. ANIMALS: 337 heifer calves newly arrived at a feedlot. PROCEDURES: Body weights, serum haptoglobin concentrations, and rumen temperatures were determined. Calves (n = 183) were randomly selected for breath sampling. Variables were compared among calves that remained healthy and those requiring treatment. RESULTS: Body weight at the time of first and second antimicrobial treatments did not differ from that at arrival, whereas body weight at the time of third antimicrobial treatment was lower. Temperature was lower at arrival, compared with that during antimicrobial treatment. Ratio of eN(2)O:eCO(2) was lowest at arrival, intermediate at the first and second antimicrobial treatments, and greatest at the third antimicrobial treatment. Ratio of eCO:eCO(2) was greater at times of antimicrobial treatment, compared with arrival. Concentration of serum haptoglobin was greatest at the time of the first antimicrobial treatment, lowest at the times of second and third treatments, and intermediate at arrival. Arrival ratios of eN(2)O: eCO(2) and eCO:eCO(2) and concentration of haptoglobin did not differ among heifers subsequently treated 1, 2, or 3 times. CONCLUSIONS AND CLINICAL RELEVANCE: Although breath analysis was successfully implemented in a research feedlot, arrival rumen temperature, eN(2)O, eCO, and haptoglobin concentration were not accurate in predicting occurrence of BRD during a preconditioning program. However, these biomarkers might support the diagnosis of BRD.


Assuntos
Testes Respiratórios , Doenças dos Bovinos/diagnóstico , Haptoglobinas/metabolismo , Infecções Respiratórias/veterinária , Animais , Biomarcadores , Bovinos , Doenças dos Bovinos/sangue , Feminino , Infecções Respiratórias/diagnóstico
2.
Appl Opt ; 46(19): 3969-75, 2007 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-17571133

RESUMO

A high-resolution liquid-nitrogen-free mid-infrared tunable diode laser absorption spectroscopy (TDLAS) system was used to perform real-time measurement of acetaldehyde concentrations in human exhaled breath following ingestion of an alcoholic beverage. Acetaldehyde absorption features were measured near 5.79 mum (1727 cm(-1)) using a IV-VI semiconductor laser, a 100 m long path optical gas cell, and second- harmonic detection coupled with wavelength modulation. Acetaldehyde levels were measured with a minimum detection limit of 80 ppb for 5 s integration time. The variations in exhaled acetaldehyde levels over time were analyzed prior to and following ingestion of two different amounts of white wine. A method to calibrate acetaldehyde measurements internally using water vapor absorption lines was investigated to eliminate the need for system calibration with gas standards. The potential of a TDLAS system to be used as a noninvasive clinical tool for measurements of large volatile compounds with possible applications in cancer detection is demonstrated.


Assuntos
Acetaldeído/análise , Testes Respiratórios , Óptica e Fotônica , Espectrofotometria , Absorção , Acetaldeído/química , Calibragem , Gases , Humanos , Lasers , Modelos Teóricos , Espectrofotometria Infravermelho , Fatores de Tempo , Água/química
3.
Nitric Oxide ; 15(2): 154-62, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16540356

RESUMO

Nitric oxide (NO) is an important biological signaling agent. The specific detection of NO represents a continuing challenge in the field of NO research. Many methods are currently employed for the detection of NO. Here, we report a qualitative but specific detection method for gaseous NO liberated in and from solution taking advantage of its low solubility. Importantly, our mid-infrared laser absorption method does not depend on any chemical derivatization of NO, and is applicable over a wide range of concentrations for both protein work and in organic-inorganic modeling work. We also apply this method to the specific detection of 15NO.


Assuntos
Gases/análise , Lasers , Óxido Nítrico/análise , Espectrofotometria Infravermelho/métodos , Isótopos de Nitrogênio/análise , Solubilidade , Soluções/química
4.
Appl Opt ; 41(28): 6018-29, 2002 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-12371564

RESUMO

We used a high-resolution mid-IR tunable-laser absorption spectroscopy (TLAS) system with a single IV-VI laser operating near 5.2 microm to measure the level of exhaled nitric oxide (eNO) in human breath. A method of internal calibration using simultaneous eNO and exhaled CO2 measurements eliminated the need for system calibration with gas standards. The results observed from internally calibrating the instrument for eNO measurements were compared with measurements of eNO calibrated to gas standards and were found to be similar. Various parameters of the TLAS system for eNO breath testing were examined and include gas cell pressure, exhalation time, and ambient NO concentrations. A reduction in eNO from elevated concentrations (approximately 44 parts in 10(9)) to near-normal levels (<20 parts in 10(9)) from an asthmatic patient was observed after the patient had received treatment with an inhaled glucocorticoid anti-inflammatory medication. Such measurements can help in evaluating airway inflammation and in monitoring the effectiveness of anti-inflammatory therapies.


Assuntos
Asma/fisiopatologia , Testes Respiratórios/instrumentação , Testes Respiratórios/métodos , Lasers , Óxido Nítrico , Absorção , Dióxido de Carbono , Humanos , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA