RESUMO
PURPOSE: Rapid on-site-evaluation (ROSE) is a technique aimed at improving the diagnostic performance of computed tomography (CT)-guided core needle biopsy (CNB) in lung cancer. The aim of this retrospective study was to investigate the impact of ROSE on the rate of nondiagnostic specimens and on accuracy computed on diagnostic specimens. MATERIALS AND METHODS: During a 3-year period, 417 CT-guided CNBs were performed at our center. The biopsies were retrospectively classified into 2 groups: 141 procedures were assisted by ROSE and 276 were not. All of them were reviewed for clinical, procedural, and pathological data. Pathology results were classified as diagnostic (positive or negative for malignancy) or nondiagnostic. The results were compared with the final diagnosis after surgery or clinical follow-up. Nondiagnostic rate, sensitivity/specificity/negative predictive value/positive predictive value for the ROSE and non-ROSE groups were calculated. Finally, procedural complications and the adequacy of the specimens for the molecular analysis were recorded. RESULTS: The study evaluated 417 CNBs (mean patients' age 71 years, 278 men). Nondiagnostic rates with and without ROSE were 4% (6/142) and 11% (29/276), respectively ( P = 0.028). Sensitivity/specificity/negative predictive value/positive predictive value with and without ROSE did not show statistically significant differences, and no difference in major/minor complication rates was observed between the 2 groups. The adequacy of specimen for subsequent molecular analysis was 100% with (42/42) and 82% without ROSE (51/62). CONCLUSIONS: Rapid on-site-evaluation reduced the rate of nondiagnostic specimens by 50% with no change in complication rates or accuracy and increased by 20% the chances of a successful subsequent molecular analysis.
Assuntos
Biópsia Guiada por Imagem , Neoplasias Pulmonares , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Feminino , Idoso , Estudos Retrospectivos , Biópsia com Agulha de Grande Calibre/métodos , Biópsia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X/métodos , Pessoa de Meia-Idade , Avaliação Rápida no Local , Idoso de 80 Anos ou mais , Radiografia Intervencionista/métodos , Reprodutibilidade dos Testes , Adulto , Pulmão/diagnóstico por imagem , Pulmão/patologiaRESUMO
OBJECTIVE: Magnetic resonance (MR) relaxometry is an absolute and reproducible quantitative method, compared with signal intensity for the evaluation of liver biliary function. This is obtainable by the T1 reduction rate (T1RR), as it carries a smaller systematic error than the pre/post contrast agent T1 measurement. We aimed to develop and test an MR T1 relaxometry tool tailored for the evaluation of liver T1RR after gadolinium ethoxybenzyl-diethylenetriaminepentaacetic acid administration on 1.5T MR. METHODS: In vitro/vivo (liver) T1RR values with two 3D FLASH variable-flip-angle sequences were calculated by a MATLAB algorithm. In vitro measurements were done by 2 physicists, in consensus. The prospective in vivo study was approved by the local ethical committee and performed on 13 normal/26 cirrhotic livers. A supplemental test in 5 normal/5 cirrhotic livers, out of the studied series, was done to compare the results of our method (without B1 inhomogeneity correction) and those of a standardized commercial tool (with B1 inhomogeneity correction). All in vivo evaluations were performed by 2 radiologists with 7 years of experience in abdominal imaging. Open-source Java-based software ImageJ was used to draw the free-hand regions of interest on liver section and for the measurement of hepatic T1RR values. The T1RR values of each group of patients were compared to assess statistically significant differences. All statistical analyses were performed with IBM-SPSS Statistics. In vivo evaluations, the intrareader and interreader reliability was assessed by intraclass correlation coefficient. RESULTS: Our method showed good accuracy in evaluating in vitro T1RR with a maximum percentage error of 9% (constant at various time points) with T1 values in the 200- to 1400-millisecond range. In vivo, a high concordance between the T1RR evaluated with the proposed method and that calculated from the standardized commercial software was verified ( P < 0.05). The median T1RRs were 74.8, 67.9, and 52.1 for the normal liver, Child-Pugh A, and Child-Pugh B cirrhotic groups, respectively. A very good agreement was found, both within intrareader and interreader reliability, with intraclass correlation coefficient values ranging from 0.88 to 0.95 and from 0.85 to 0.90, respectively. CONCLUSIONS: The proposed method allowed accurate reliable in vitro/vivo T1RR assessment evaluation of the liver biliary function after gadolinium ethoxybenzyl-diethylenetriaminepentaacetic acid administration.
Assuntos
Meios de Contraste , Gadolínio DTPA , Fígado , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Fígado/diagnóstico por imagem , Adulto , Idoso , Reprodutibilidade dos Testes , Algoritmos , Cirrose Hepática/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodosRESUMO
The histologic definition of peripheral pulmonary lesion (PPL) is critical for a correct diagnosis and appropriate therapy. Non-invasive techniques for PPL biopsy are imaging-guided, using endobronchial ultrasound (EBUS), computed tomography (CT), and electromagnetic navigation bronchoscopy (ENB). To assess the diagnostic accuracy of PPL biopsy and provide a framework for reporting data for accuracy studies of PPL biopsy. A systematic review was conducted on PubMed, Scopus, and Web of Science to identify all the articles assessing the accuracy of EBUS, CT, and ENB between January 2000 and June 2023 basing search queries on keywords emerging from PICO question. Only studies investigating biopsy of PPL and reporting accuracy or necessary data to calculate it independently were included. Risk of bias was based on QUADAS-2 tool. In total, 81 studies were included. Median accuracy was 0.78 (range=0.51-0.94) in the EBUS group, 0.91 (range=0.73-0.97) in the CT group, 0.72 (range=0.59-0.97) in the ENB group, and 0.77 (range=0.61-0.92) in the combined group. Sensitivity and NPV ranges were 0.35-0.94 and 0.26-0.88 in the EBUS group, 0.71-0.97 and 0.46-1.00 in the CT group, 0.55-0.96 and 0.32-0.90 in the ENB group, and 0.70-0.90 and 0.28-0.79 in the combined group. Specificity and PPV were 1.00 in almost all studies. Overall complication rate was 3%, 30%, 8%, and 5% in the EBUS, CT, ENB, and combined groups. CT-guided biopsy was the most accurate technique, although with the highest complication rate. When calculating accuracy, indeterminate results must be considered false negatives according to the "intention-to-diagnose" principle.
Assuntos
Broncoscopia , Biópsia Guiada por Imagem , Humanos , Biópsia Guiada por Imagem/métodos , Broncoscopia/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Tomografia Computadorizada por Raios X/métodos , Sensibilidade e Especificidade , Pneumopatias/diagnóstico por imagem , Pneumopatias/patologia , Reprodutibilidade dos TestesRESUMO
OBJECTIVE: Apical periodontitis (AP) is one of the most common pathologies of the oral cavity. An early and accurate diagnosis of AP lesions is crucial for proper management and planning of endodontic treatments. This study investigated the diagnostic accuracy of periapical radiography (PR) and panoramic radiography (PAN) in the detection of clinically/surgically/histopathologically confirmed AP lesions. METHOD: A systematic literature review was conducted in accordance with the PRISMA guidelines. The search strategy was limited to English language articles via PubMed, Embase and Web of Science databases up to June 30, 2023. Such articles provided diagnostic accuracy values of PR and/or PAN in the detection of AP lesions or alternatively data needed to calculate them. RESULTS: Twelve studies met inclusion criteria and were considered for the analysis. The average value of diagnostic accuracy in assessing AP lesions was 71% for PR and 66% for PAN. According to different accuracy for specific anatomical areas, it is recommended to use PR in the analysis of AP lesions located in the upper arch and lower incisor area, whereas lower premolar and molar areas may be investigated with the same accuracy with PR or PAN. CONCLUSIONS: Two-dimensional imaging must be considered the first-level examination for the diagnosis of AP lesions. PR had an overall slightly higher diagnostic accuracy than PAN. Evidence from this review provided a useful tool to support radiologists and dentists in their decision-making when inflammatory periapical bone lesions are suspected to achieve the best clinical outcome for patients, improving the quality of clinical practice.
RESUMO
INTRODUCTION: The sustentaculum tali is displaced in almost half of calcaneal fractures and during surgical fixation represents one of the main reference points upon which the other bone has to be reduced. The purpose of this study was to investigate which subtalar joint fracture pattern is more frequently associated with sustentaculum tali involvement. Furthermore, correlation between postoperative clinical outcome and sustentaculum tali integrity was performed. MATERIAL AND METHODS: Patients with isolated calcaneal fractures were analyzed. Sanders-type fracture and involvement of both sustentaculum tali and calcaneocuboid joint were detected on computed tomography imaging; postoperative AOFAS scores were analyzed according to sustentacular involvement. RESULTS: Fifty calcaneus fractures in 47 patients were included in the final analysis. The sustentaculum tali was fractured in 18 cases (36.0%), thus contradicting its supposed constant position. Sanders type 3 and 4 fractures were more frequently associated with fractured sustentaculum than type 2 (p = 0.012). Sanders type 4 fractures were associated with displaced sustentacular fragment significantly more than type 2 and 3 (p = 0.043). Patients with intact sustentaculum tali reported significantly higher (p < 0.001) mean AOFAS scores than the uninjured group (84.4 ± 9.1 and 74.3 ± 9.5, respectively). CONCLUSION: Sanders type 3 and 4 fractures were more frequently associated with sustentaculum tali and/or calcaneocuboid joint involvement than simpler fractures. Injury of sustentaculum tali was related to significant worse postoperative clinical outcomes, underlying the relevance of this fragment on clinical course.
Assuntos
Traumatismos do Tornozelo , Calcâneo , Fraturas Ósseas , Humanos , Calcâneo/diagnóstico por imagem , Calcâneo/cirurgia , Calcâneo/lesões , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Parafusos Ósseos , Fraturas Ósseas/complicações , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Pé , Resultado do TratamentoRESUMO
BACKGROUND: Peliosis hepatis (PH) is a rare benign condition, characterized by hepatic sinusoidal dilatation and blood-filled cystic cavities, often found incidentally, with still challenging diagnosis by imaging due to polymorphic appearance. PURPOSE: Based on a retrospective analysis of our series (12 patients) and systematic literature review (1990-2022), to organize data about PH and identify features to improve characterization. STUDY TYPE: Retrospective case series and systematic review. POPULATION: Twelve patients (mean age 48 years, 55% female) with pathology-proven PH and 49 patients (mean age 52 years, 67% female) identified in 33 studies from the literature (1990-2022). FIELD STRENGTH/SEQUENCE: 1,5-T; T1-weighted (T1W), T2-weighted (T2W), diffusion-weighted (DW), contrast-enhanced (CE) T1W imaging. ASSESSMENT: We compared our series and literature data in terms of demographic (gender/age/ethnicity), clinical characteristics (symptoms/physical examination/liver test), associated conditions (malignancies/infectious/hematologic/genetic or chronic disorders/drugs or toxic exposure) percentage. On magnetic resonance imaging lesion numbers/shape/mean maximum diameter/location/mass effect/signal intensity were compared. PH pathological type/proposed imaging diagnosis/patient follow-up were also considered. STATISTICAL TESTS: Joanna Briggs Institute (JBI) Critical Appraisal Checklist for Case Reports/Series quality assessment. Intraclass correlation and Cohen's kappa coefficients for levels of inter/intrareader agreement in our experience. RESULTS: Patients were mainly asymptomatic (92% vs. 70% in our study and literature) with associated conditions (83% vs. 80%). Lesions showed homogeneous T1W-hypointensity (58% vs. 65%) and T2W-hyperintensity (58% vs. 66%). Heterogeneous nonspecific (25% vs. 51%), centrifugal (34% vs. 8%), or rim-like centripetal (25% vs. 23%) patterns of enhancement were most frequent, with hypointensity on the hepatobiliary phase (HBP), without restricted diffusivity. Good inter- and intrareader agreement was observed in our experience. Concerning JBI Checklist, 19 out of 31 case reports met at least 7 out of 8 criteria, whereas 2 case series fulfilled 5 and 6 out of 10 items respectively. DATA CONCLUSION: A homogeneous, not well-demarcated T1W-hypointense and T2W-hyperintense mass, with heterogeneous nonspecific or rim-like centripetal or centrifugal pattern of enhancement, and hypointensity on HBP, may be helpful for PH diagnosis. Among associated conditions, malignancies and drug exposures were the most frequent. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 2.
Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Peliose Hepática , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Peliose Hepática/diagnóstico por imagem , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Meios de ContrasteRESUMO
BACKGROUND: COVID-19 is a pandemic disease affecting predominantly the respiratory apparatus with clinical manifestations ranging from asymptomatic to respiratory failure. Chest CT is a crucial tool in diagnosing and evaluating the severity of pulmonary involvement through dedicated scoring systems. Nonetheless, many questions regarding the relationship of radiologic and clinical features of the disease have emerged in multidisciplinary meetings. The aim of this retrospective study was to explore such relationship throughout an innovative and alternative approach. MATERIALS AND METHODS: This study included 550 patients (range 25-98 years; 354 males, mean age 66.1; 196 females, mean age 70.9) hospitalized for COVID-19 with available radiological and clinical data between 1 March 2021 and 30 April 2022. Radiological data included CO-RADS, chest CT score, dominant pattern, and typical/atypical findings detected on CT examinations. Clinical data included clinical score and outcome. The relationship between such features was investigated through the development of the main four frequently asked questions summarizing the many issues arisen in multidisciplinary meetings, as follows 1) CO-RADS, chest CT score, clinical score, and outcomes; 2) the involvement of a specific lung lobe and outcomes; 3) dominant pattern/distribution and severity score for the same chest CT score; 4) additional factors and outcomes. RESULTS: 1) If CT was suggestive for COVID, a strong correlation between CT/clinical score and prognosis was found; 2) Middle lobe CT involvement was an unfavorable prognostic criterion; 3) If CT score < 50%, the pattern was not influential, whereas if CT score > 50%, crazy paving as dominant pattern leaded to a 15% increased death rate, stacked up against other patterns, thus almost doubling it; 4) Additional factors usually did not matter, but lymph-nodes and pleural effusion worsened prognosis. CONCLUSIONS: This study outlined those radiological features of COVID-19 most relevant towards disease severity and outcome with an innovative approach.
Assuntos
COVID-19 , Masculino , Feminino , Humanos , Idoso , COVID-19/diagnóstico por imagem , SARS-CoV-2 , Estudos Retrospectivos , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodosRESUMO
OBJECTIVE: Identifying MRI texture parameters able to distinguish inflammation, fibrosis, and residual cancer in patients with naso-oropharynx carcinoma after radiochemotherapy (RT-CHT). MATERIAL AND METHODS: In this single-centre, observational, retrospective study, texture analysis was performed on ADC maps and post-gadolinium T1 images of patients with histological diagnosis of naso-oropharyngeal carcinoma treated with RT-CHT. An initial cohort of 99 patients was selected; 57 of them were later excluded. The final cohort of 42 patients was divided into 3 groups (inflammation, fibrosis, and residual cancer) according to MRI, 18F-FDG-PET/CT performed 3-4 months after RT-CHT, and biopsy. Pre-RT-CHT lesions and the corresponding anatomic area post-RT-CHT were segmented with 3D slicer software from which 107 textural features were derived. T-Student and Wilcoxon signed-rank tests were performed, and features with p-value < 0.01 were considered statistically significant. Cut-off values-obtained by ROC curves-to discriminate post-RT-CHT non-tumoural changes from residual cancer were calculated for the parameters statistically associated to the diseased status at follow-up. RESULTS: Two features-Energy and Grey Level Non-Uniformity-were statistically significant on T1 images in the comparison between 'positive' (residual cancer) and 'negative' patients (inflammation and fibrosis). Energy was also found to be statistically significant in both patients with fibrosis and residual cancer. Grey Level Non-Uniformity was significant in the differentiation between residual cancer and inflammation. Five features were statistically significant on ADC maps in the differentiation between 'positive' and 'negative' patients. The reduction in values of such features between pre- and post-RT-CHT was correlated with a good response to therapy. CONCLUSIONS: Texture analysis on post-gadolinium T1 images and ADC maps can differentiate residual cancer from fibrosis and inflammation in early follow-up of naso-oropharyngeal carcinoma treated with RT-CHT.
Assuntos
Carcinoma , Neoplasias Orofaríngeas , Humanos , Estudos Retrospectivos , Gadolínio , Neoplasia Residual , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Imageamento por Ressonância Magnética/métodos , Fibrose , Carcinoma/diagnóstico por imagem , Carcinoma/terapia , QuimiorradioterapiaRESUMO
OBJECTIVE: The aim of this study was to identify the main CT features that may help in distinguishing a progression of interstitial lung disease (ILD) secondary to SSc from COVID-19 pneumonia. METHODS: This multicentric study included 22 international readers grouped into a radiologist group (RADs) and a non-radiologist group (nRADs). A total of 99 patients, 52 with COVID-19 and 47 with SSc-ILD, were included in the study. RESULTS: Fibrosis inside focal ground-glass opacities (GGOs) in the upper lobes; fibrosis in the lower lobe GGOs; reticulations in lower lobes (especially if bilateral and symmetrical or associated with signs of fibrosis) were the CT features most frequently associated with SSc-ILD. The CT features most frequently associated with COVID- 19 pneumonia were: consolidation (CONS) in the lower lobes, CONS with peripheral (both central/peripheral or patchy distributions), anterior and posterior CONS and rounded-shaped GGOs in the lower lobes. After multivariate analysis, the presence of CONs in the lower lobes (P < 0.0001) and signs of fibrosis in GGOs in the lower lobes (P < 0.0001) remained independently associated with COVID-19 pneumonia and SSc-ILD, respectively. A predictive score was created that was positively associated with COVID-19 diagnosis (96.1% sensitivity and 83.3% specificity). CONCLUSION: CT diagnosis differentiating between COVID-19 pneumonia and SSc-ILD is possible through a combination of the proposed score and radiologic expertise. The presence of consolidation in the lower lobes may suggest COVID-19 pneumonia, while the presence of fibrosis inside GGOs may indicate SSc-ILD.
Assuntos
COVID-19 , Doenças Pulmonares Intersticiais , Escleroderma Sistêmico , COVID-19/complicações , COVID-19/diagnóstico por imagem , Teste para COVID-19 , Fibrose , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Doenças Pulmonares Intersticiais/complicações , Doenças Pulmonares Intersticiais/etiologia , Escleroderma Sistêmico/complicações , Escleroderma Sistêmico/diagnóstico por imagem , Escleroderma Sistêmico/patologia , Tomografia Computadorizada por Raios XRESUMO
The sphenoid bone is an unpaired bone that contributes to the formation of the skull base. Despite the enormous progress in transnasal endoscopic visualisation, imaging techniques remain the cornerstones to characterise any pathological condition arising in this area. In the present review, we offer a bird's-eye view of the developmental, inflammatory, and neoplastic alterations affecting the sphenoid body and clivus, with the aim to propose a practical diagnostic aid for radiologists based on clinico-epidemiological, computed tomography, and magnetic resonance imaging features.
Assuntos
Fossa Craniana Posterior , Base do Crânio , Fossa Craniana Posterior/diagnóstico por imagem , Fossa Craniana Posterior/patologia , Humanos , Imageamento por Ressonância Magnética/métodos , Osso Esfenoide/diagnóstico por imagem , Osso Esfenoide/patologia , Tomografia Computadorizada por Raios X/métodosRESUMO
BACKGROUND: Chest radiography (CR) patterns for the diagnosis of COVID-19 have been established. However, they were not ideated comparing CR features with those of other pulmonary diseases. PURPOSE: To create the most accurate COVID-19 pneumonia pattern comparing CR findings of COVID-19 and non-COVID-19 pulmonary diseases and to test the model against the British Society of Thoracic Imaging (BSTI) criteria. MATERIAL AND METHODS: CR of COVID-19 and non-COVID-19 pulmonary diseases, admitted to the emergency department, were evaluated. Assessed features were interstitial opacities, ground glass opacities, and/or consolidations and the predominant lung alteration. We also assessed uni-/bilaterality, location (upper/middle/lower), and distribution (peripheral/perihilar), as well as pleural effusion and perihilar vessels blurring. A binary logistic regression was adopted to obtain the most accurate CR COVID-19 pattern, and sensitivity and specificity were computed. The newly defined pattern was compared to BSTI criteria. RESULTS: CR of 274 patients were evaluated (146 COVID-19, 128 non-COVID-19). The most accurate COVID-19 pneumonia pattern consisted of four features: bilateral alterations (Expß=2.8, P=0.002), peripheral distribution of the predominant (Expß=2.3, P=0.013), no pleural effusion (Expß=0.4, P=0.009), and perihilar vessels' contour not blurred (Expß=0.3, P=0.002). The pattern showed 49% sensitivity, 81% specificity, and 64% accuracy, while BSTI criteria showed 51%, 77%, and 63%, respectively. CONCLUSION: Bilaterality, peripheral distribution of the predominant lung alteration, no pleural effusion, and perihilar vessels contour not blurred determine the most accurate COVID-19 pneumonia pattern. Lower field involvement, proposed by BSTI criteria, was not a distinctive finding. The BSTI criteria has lower specificity.
Assuntos
COVID-19 , Derrame Pleural , Humanos , COVID-19/diagnóstico por imagem , SARS-CoV-2 , Diagnóstico Diferencial , Tomografia Computadorizada por Raios X/métodos , Radiografia , Pulmão/diagnóstico por imagem , Radiografia Torácica/métodos , Estudos RetrospectivosRESUMO
BACKGROUND AND PURPOSE: Morphologic magnetic resonance imaging (MRI) for characterization of salivary gland tumors has limited utility, and the use of perfusion MRI data in the clinical setting is controversial. We examined the potential of tissue-normalized dynamic contrast-enhanced (DCE) MRI pharmacokinetic parameters of salivary gland tumors as imaging biomarkers for characterization and differentiation between benign and malignant lesions. MATERIALS AND METHODS: DCE-MR images acquired from 60 patients with parotid and submandibular gland tumors were retrospectively reviewed. Pharmacokinetic parameters as transfer constant (Ktrans), rate constant (Kep), extracellular space volume (Ve), fractional plasma volume (Vp), and AEC (area of all times enhancement curve) were measured on both the lesion and the normal contralateral salivary gland parenchyma. Lesion/parenchyma ratio (L/P) for each parameter was calculated. RESULTS: Five groups of lesions were identified (reference: histopathology): pleomorphic adenomas(n = 20), Warthin tumors(n = 16), other benign entities(n = 4), non-Hodgkin lymphomas(n = 4), and malignancies(n = 16). Significant differences were seen for mean values of L/PKtrans (higher in malignancies), L/PKep (lower in adenomas than Warthin tumors), L/PVe (lower in Warthin tumors and lymphomas), L/PVp (higher in Warthin tumors and malignancies than adenomas), and L/PAEC (higher in malignancies). Significant differences were found between benign and malignant (non-lymphoproliferative) lesions in mean value of L/PKtrans (0.485 and 1.581), L/PVp (1.288 and 2.834), and L/PAEC (0.682 and 1.910). ROC analysis demonstrated the highest AUC (0.96) for L/PAEC, with sensitivity and specificity for malignancy of 93.8% and 97.5% (cutoff value = 1.038). CONCLUSION: Lesion/parenchyma ratio of DCE-MRI pharmacokinetic data could be helpful for recognizing the principal types of salivary gland tumors; L/PAEC seems a valuable biomarker for differentiating benign from malignant tumors.
Assuntos
Meios de Contraste/farmacocinética , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias das Glândulas Salivares/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Glândulas Salivares/diagnóstico por imagem , Sensibilidade e EspecificidadeRESUMO
OBJECTIVES: Pleuroparenchymal fibroelastosis (PPFE) is characterized by predominantly upper lobe pleural and subjacent parenchymal fibrosis; PPFE features were described in patients with rheumatic autoimmune diseases (RAID). A systematic literature review was performed to investigate the prevalence, prognosis and potential association of PPFE with previous immunosuppression in RAID. METHODS: EMBASE, Web of Science and PubMed databases were questioned from inception to 1 September 2019. Articles published in English and addressing PPFE in patients with RAID were selected. RESULTS: Twenty out of 794 papers were selected with a total of 76 cases of RAID-PPFE patients (20 SSc, 9 RA, 6 IIM6 primary SS, 5 overlap syndromes, 3 ANCA-associated vasculitides, 2 granulomatosis with polyangiitis, 1 microscopic polyangiitis, 1 UCTD, 1 SLE, 1 GCA and 21 patients with non-specified RAID). Dyspnoea was the most frequently reported symptom (37/48 patients, 77%). Patients frequently presented with a restrictive pattern and decline in diffusing lung capacity for carbon monoxide. During the follow-up, 7/12 patients had progression at imaging, 22/39 presented a generic clinical worsening, 19/38 had a functional deterioration and 15/43 remained stable. CONCLUSION: The present systematic literature review confirms that PPFE features are present in RAID. Rheumatologists should be aware of this new radiological pattern that holds a bad prognosis.
Assuntos
Doenças Autoimunes/complicações , Doenças Pleurais/etiologia , Fibrose Pulmonar/etiologia , Doenças Reumáticas/complicações , Humanos , Doenças Pleurais/diagnóstico , Doenças Pleurais/terapia , Fibrose Pulmonar/diagnóstico , Fibrose Pulmonar/terapia , Doenças Reumáticas/imunologiaRESUMO
INTRODUCTION: This study aimed to evaluate the accuracy of both digital complete and small portion of panoramic radiography (PAN) in the detection of clinically/surgically confirmed asymptomatic apical periodontitis (AP) lesions with and without endodontic treatment. METHODS: A total of 480 patients/teeth including 120 AP with and without endodontic treatment, and 120 healthy periapex with and without endodontic treatment were detected via CBCT using the periapical index system. Each diseased and healthy patient underwent PAN first and a CBCT scan within 40 days. All 480 cases were assessed by four different methods, as follows: complete PAN with clinical examination of each tooth available and not available, respectively, and small portion of PAN in which a root with crown and root without crown were displayed, respectively. Periapical index system was also used to assess AP by PAN. Accuracy for both complete and small portion of PAN with respect to CBCT was analyzed. RESULTS: The overall accuracy of the four methods for teeth with endodontic treatment (73.4) was higher than teeth without endodontic treatment (66.6). Accuracy of complete PAN and portion of PAN was 71.3 and 68.7, respectively. As regards teeth without endodontic treatment, accuracy was higher for complete PAN in the upper/lower incisive area and for small portion of PAN in the upper molar area. No difference was found in teeth with endodontic treatment. CONCLUSION: Complete and small portion of PAN showed greater accuracy in the upper/lower incisive area and upper molar area of untreated teeth, respectively, whereas no difference was found in treated teeth.
Assuntos
Tomografia Computadorizada de Feixe Cônico , Periodontite Periapical/diagnóstico por imagem , Intensificação de Imagem Radiográfica , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Panorâmica , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Periodontite Periapical/terapiaRESUMO
OBJECTIVES: To evaluate the association of magnetic resonance diffusion-weighted imaging (DwI) and dynamic contrast-enhanced perfusion-weighted imaging (DCE-PwI) with a temporal resolution of 5 s, wash-in < 120 s, and wash-out ratio > 30% in the evaluation of salivary glands neoplasms. METHODS: DwI and DCE-PwI of 92 salivary glands neoplasms were assessed. The apparent diffusion coefficient (ADC) was calculated by drawing three regions of interest with an average area of 0.30-0.40 cm2 on three contiguous axial sections. The time/intensity curve was generated from DCE-PwI images by drawing a region of interest that included at least 50% of the largest lesion section. Vessels, calcifications, and necrotic/haemorrhagic or cystic areas within solid components were excluded. The association of ADC ≥ 1.4 × 10-3 mm2/s with type A curves (progressive wash-in) and ADC 0.9-1.4 × 10-3 mm2/s with type C curves (rapid wash-in/slow wash-out) were tested as parameters of benignity and malignancy, respectively. Type B curve (rapid wash-in/rapid wash-out) was not used as a reference parameter. RESULTS: ADC ≥ 1.4 × 10-3 mm2/s and type A curves were observed only in benign neoplasms. ADC of 0.9-1.4 × 10-3 mm2/s and type C curves association showed specificity of 94.9% and positive predictive value of 81.8% for epithelial malignancies. The association of ADC < 0.9 × 10-3 mm2/s with type B and C curves showed diagnostic accuracy of 94.6% and 100% for Warthin tumour and lymphoma, respectively. CONCLUSIONS: ADC ≥ 1.4 × 10-3 mm2/s and type A curves association was indicative of benignity. Lymphomas exhibited ADC < 0.7 × 10-3 mm2/s and type C curves. The association of ADC < 0.9 × 10-3 mm2/s and type B and C curves had accuracy 94.6% and 88.5% for Warthin tumour and epithelial malignancies, respectively.
Assuntos
Meios de Contraste , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias das Glândulas Salivares/diagnóstico por imagem , Adenolinfoma/diagnóstico por imagem , Adenoma Pleomorfo/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Linfoma/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Neoplasias Epiteliais e Glandulares/diagnóstico por imagem , Estudos Retrospectivos , Adulto JovemRESUMO
OBJECTIVES: To evaluate thyroid, arytenoid, and cricoid cartilage invasion on computed tomography (CT) imaging in patients undergoing total laryngectomy for both primary and recurrent laryngeal carcinoma. Secondary endpoint was to compare laryngeal cartilage invasion between primary and recurrent tumours. METHODS: Pre-treatment CT of 40 patients who had undergone total laryngectomy was retrospectively evaluated and compared with histology. Focal erosions of thyroid cartilage were accounted for neoplastic invasion of the inner cortex. Full-thickness thyroid cartilage invasion was defined as a tumour-like tissue replacing thyroid cartilage or extended in extra-laryngeal soft tissues. Sclerosis and erosion of arytenoid and cricoid cartilages were assessed as signs of neoplastic invasion. RESULTS: CT erosion showed perfect agreement for thyroid inner cortex and cricoid cartilage invasion and almost perfect agreement (87%) for arytenoid cartilage invasion. For tumours in contact with thyroid cartilages, the absence of CT erosion underestimated inner cortex infiltration. CT showed perfect agreement in predicting full-thickness thyroid cartilage invasion only in the case of extra-laryngeal neoplastic extension. Arytenoid sclerosis showed poor correlation with neoplastic invasion. For primary tumours, CT demonstrated good (inner cortex 75%; full-thickness 85%), substantial (67.5%), and perfect (100%) accuracy in thyroid, arytenoid, and cricoid cartilage invasion, respectively. No CT differences were observed between primary and recurrent laryngeal tumours. CONCLUSION: Tumour-like tissue extension in the extra-laryngeal soft tissues was accurate in predicting thyroid cartilage full-thickness invasion. Erosions of arytenoid, cricoid, and thyroid cartilages' inner cortex on CT were highly indicative of neoplastic infiltration. No CT difference in cartilage infiltration between primary and recurrent tumours was observed.
Assuntos
Cartilagens Laríngeas/diagnóstico por imagem , Neoplasias Laríngeas/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Recidiva Local de Neoplasia/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Cartilagem Aritenoide/diagnóstico por imagem , Cartilagem Aritenoide/patologia , Meios de Contraste/administração & dosagem , Cartilagem Cricoide/diagnóstico por imagem , Cartilagem Cricoide/patologia , Feminino , Humanos , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Cartilagens Laríngeas/patologia , Neoplasias Laríngeas/patologia , Neoplasias Laríngeas/cirurgia , Masculino , Pessoa de Meia-Idade , Invasividade Neoplásica , Recidiva Local de Neoplasia/patologia , Estudos Retrospectivos , Sensibilidade e Especificidade , Cartilagem Tireóidea/diagnóstico por imagem , Cartilagem Tireóidea/patologiaRESUMO
The treatment of an 8-year-old girl with a dilacerated maxillary incisor began in the mixed dentition; a modified palatal arch attached to the molars served as anchorage for the forced eruption of the dilacerated tooth to prevent the intrusion of the adjacent teeth and reduce the risk of root resorption. Two surgical sessions were planned: the first to permit the closed eruption; the second was an apically positioned flap to add attached gingiva to the labial side of the erupting tooth. The result was an optimal periodontal outcome; moreover, the roots of the adjacent teeth did not show any sign of resorption at the end of the forced eruption. The tooth was vital at the end of the treatment, and the apex covered by alveolar mucosa. The root developed normally throughout the treatment, and the periodontium was healthy and esthetically acceptable at the 2-year follow-up. Further study is needed to assess the advantages of the combined surgical-orthodontic treatment.
Assuntos
Incisivo , Dente Impactado , Criança , Feminino , Seguimentos , Humanos , Maxila , Extrusão Ortodôntica , Técnicas de Movimentação Dentária , Raiz DentáriaRESUMO
BACKGROUND: The mechanisms underlying airflow obstruction in COPD cannot be distinguished by standard spirometry. We ascertain whether mathematical modeling of airway biomechanical properties, as assessed from spirometry, could provide estimates of emphysema presence and severity, as quantified by computed tomography (CT) metrics and CT-based radiomics. METHODS: We quantified presence and severity of emphysema by standard CT metrics (VIDA) and co-registration analysis (ImbioLDA) of inspiratory-expiratory CT in 194 COPD patients who underwent pulmonary function testing. According to percentages of low attenuation area below - 950 Hounsfield Units (%LAA-950insp) patients were classified as having no emphysema (NE) with %LAA-950insp < 6, moderate emphysema (ME) with %LAA-950insp ≥ 6 and < 14, and severe emphysema (SE) with %LAA-950insp ≥ 14. We also obtained stratified clusters of emphysema CT features by an automated unsupervised radiomics approach (CALIPER). An emphysema severity index (ESI), derived from mathematical modeling of the maximum expiratory flow-volume curve descending limb, was compared with pulmonary function data and the three CT classifications of emphysema presence and severity as derived from CT metrics and radiomics. RESULTS: ESI mean values and pulmonary function data differed significantly in the subgroups with different emphysema degree classified by VIDA, ImbioLDA and CALIPER (p < 0.001 by ANOVA). ESI differentiated NE from ME/SE CT-classified patients (sensitivity 0.80, specificity 0.85, AUC 0.86) and SE from ME CT-classified patients (sensitivity 0.82, specificity 0.87, AUC 0.88). CONCLUSIONS: Presence and severity of emphysema in patients with COPD, as quantified by CT metrics and radiomics can be estimated by mathematical modeling of airway function as derived from standard spirometry.
Assuntos
Enfisema/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Índice de Gravidade de Doença , Espirometria/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Enfisema/epidemiologia , Enfisema/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologiaRESUMO
OBJECTIVES: To evaluate the incidence of late-gadolinium-enhancement (LGE) in mitral valve prolapse (MVP) (in the absence of other heart/valvular diseases), and its association with the degree of mitral regurgitation (MR) and/or with complex ventricular arrhythmia (ComVA), and to analyse the role of T1 mapping in the evaluation of MVP patients. METHODS: We included all consecutive patients with MVP who underwent during 2015-2016 a comprehensive cardiac magnetic resonance (CMR) examination at 1.5 T. We evaluated the association of LGE with the MR fraction and the presence of ComVA. We compared myocardial T1-native and post-contrast times and extracellular volume (ECV)-values between MVP patients, both with and without LGE, and the control group. RESULTS: Thirty-four patients with MVP were selected (56 ± 14 years old, 59% male). All patients had MR; LGE and ComVA were present in 15 (44%) and 11 (34%) patients, respectively. Significant associations of LGE with both MR severity and ComVA were not found (p=0.72 and 0.79, respectively). T1 mapping confirmed the presence of LGE in all cases. In one patient a thin signal alteration resulted in more evident T1 mapping than LGE. Patients with MVP had higher native T1-values, lower post-contrast T1-values and increased ECV-values compared with controls (p=0.01, 0.01 and 0.00, respectively). CONCLUSION: Focal fibrosis with LGE was found in about half the MVP patients and it was independent of the degree of the valve dysfunction and the presence of ComVA. T1 mapping allows diffuse myocardial wall alterations to be identified, but no significant associations between the MR severity and ComVA and T1/ECV values were found. KEY POINTS: ⢠MVP is a common valvulopathy affecting 2-3% of the general population. ⢠MVP has been associated with an increased risk of arrhythmic complications and sudden cardiac death. ⢠CMR is a non-invasive imaging method that provides a precise and more accurate assessment of patients with MVP.