Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Liver Transpl ; 30(5): 544-554, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38240602

RESUMO

The 2023 Joint International Congress of the International Liver Transplantation Society (ILTS), the European Liver and Intestine Transplant Association (ELITA), and the Liver Intensive Care Group of Europe (LICAGE) held in Rotterdam, the Netherlands, marked a significant recovery milestone for the liver transplant community after COVID-19. With 1159 participants and a surge in abstract submissions, the event focused on "Liver Disorders and Transplantation: Innovations and Evolving Indications." This conference report provides a comprehensive overview of the key themes discussed during the event, encompassing Hepatology, Anesthesia and Critical Care, Acute Liver Failure, Infectious Disease, Immunosuppression, Pediatric Liver Transplantation, Living Donor Liver Transplantation, Transplant Oncology, Surgical Approaches, and Machine Perfusion. The congress provided a platform for extensive discussions on a wide range of topics, reflecting the continuous advancements and collaborative efforts within the liver transplant community.


Assuntos
Transplante de Fígado , Criança , Humanos , Terapia de Imunossupressão , Doadores Vivos
2.
Nature ; 557(7703): 50-56, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29670285

RESUMO

Liver transplantation is a highly successful treatment, but is severely limited by the shortage in donor organs. However, many potential donor organs cannot be used; this is because sub-optimal livers do not tolerate conventional cold storage and there is no reliable way to assess organ viability preoperatively. Normothermic machine perfusion maintains the liver in a physiological state, avoids cooling and allows recovery and functional testing. Here we show that, in a randomized trial with 220 liver transplantations, compared to conventional static cold storage, normothermic preservation is associated with a 50% lower level of graft injury, measured by hepatocellular enzyme release, despite a 50% lower rate of organ discard and a 54% longer mean preservation time. There was no significant difference in bile duct complications, graft survival or survival of the patient. If translated to clinical practice, these results would have a major impact on liver transplant outcomes and waiting list mortality.


Assuntos
Aloenxertos/fisiologia , Transplante de Fígado/métodos , Fígado/fisiologia , Preservação de Órgãos/métodos , Temperatura , Coleta de Tecidos e Órgãos/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aloenxertos/patologia , Aloenxertos/fisiopatologia , Aloenxertos/normas , Ductos Biliares/patologia , Ductos Biliares/fisiologia , Ductos Biliares/fisiopatologia , Feminino , Sobrevivência de Enxerto , Humanos , Tempo de Internação , Fígado/enzimologia , Transplante de Fígado/efeitos adversos , Masculino , Pessoa de Meia-Idade , Preservação de Órgãos/efeitos adversos , Perfusão , Análise de Sobrevida , Doadores de Tecidos/provisão & distribuição , Coleta de Tecidos e Órgãos/efeitos adversos , Resultado do Tratamento , Listas de Espera , Adulto Jovem
3.
Liver Transpl ; 28(11): 1716-1725, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35662403

RESUMO

In situ normothermic regional perfusion (NRP) and ex situ normothermic machine perfusion (NMP) aim to improve the outcomes of liver transplantation (LT) using controlled donation after circulatory death (cDCD). NRP and NMP have not yet been compared directly. In this international observational study, outcomes of LT performed between 2015 and 2019 for organs procured from cDCD donors subjected to NRP or NMP commenced at the donor center were compared using propensity score matching (PSM). Of the 224 cDCD donations in the NRP cohort that proceeded to asystole, 193 livers were procured, resulting in 157 transplants. In the NMP cohort, perfusion was commenced in all 40 cases and resulted in 34 transplants (use rates: 70% vs. 85% [p = 0.052], respectively). After PSM, 34 NMP liver recipients were matched with 68 NRP liver recipients. The two cohorts were similar for donor functional warm ischemia time (21 min after NRP vs. 20 min after NMP; p = 0.17), UK-Donation After Circulatory Death risk score (5 vs. 5 points; p = 0.38), and laboratory Model for End-Stage Liver Disease scores (12 vs. 12 points; p = 0.83). The incidence of nonanastomotic biliary strictures (1.5% vs. 2.9%; p > 0.99), early allograft dysfunction (20.6% vs. 8.8%; p = 0.13), and 30-day graft loss (4.4% vs. 8.8%; p = 0.40) were similar, although peak posttransplant aspartate aminotransferase levels were higher in the NRP cohort (872 vs. 344 IU/L; p < 0.001). NRP livers were more frequently allocated to recipients suffering from hepatocellular carcinoma (HCC; 60.3% vs. 20.6%; p < 0.001). HCC-censored 2-year graft and patient survival rates were 91.5% versus 88.2% (p = 0.52) and 97.9% versus 94.1% (p = 0.25) after NRP and NMP, respectively. Both perfusion techniques achieved similar outcomes and appeared to match benchmarks expected for donation after brain death livers. This study may inform the design of a definitive trial.


Assuntos
Carcinoma Hepatocelular , Doença Hepática Terminal , Neoplasias Hepáticas , Transplante de Fígado , Aspartato Aminotransferases , Doença Hepática Terminal/cirurgia , Sobrevivência de Enxerto , Humanos , Transplante de Fígado/métodos , Preservação de Órgãos/métodos , Perfusão/métodos , Índice de Gravidade de Doença
4.
Clin Transplant ; 36(10): e14638, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35279883

RESUMO

BACKGROUND: Recent evidence supports the use of machine perfusion technologies (MP) for marginal liver grafts. Their effect on enhanced recovery, however, remains uncertain. OBJECTIVES: To identify areas in which MP might contribute to an ERAS program and to provide expert panel recommendations. DATA SOURCES: Ovid MEDLINE, Embase, Scopus, Google Scholar, and Cochrane Central. METHODS: Systematic review and meta-analysis following PRISMA guidelines and recommendations using the GRADE approach. CRD42021237713 RESULTS: Both hypothermic (HMP) and normothermic (NMP) machine perfusion demonstrated significant benefits in preventing postreperfusion syndrome (PRS) (HMP OR .33, .15-.75 CI; NMP OR .51, .29-.90 CI) and early allograft dysfunction (EAD) (HMP OR .51, .35-.75 CI; NMP OR .66, .45-.97 CI), while shortening LOS (HMP MD -3.9; NMP MD -12.41). Only NMP showed a significant decrease in the length of ICU stay (L-ICU) (MD -7.07, -8.76; -5.38 CI), while only HMP diminishes the likelihood of major complications. Normothermic regional perfusion (NRP) reduces EAD (OR .52, .38-.70 CI) and primary nonfunction (PNF) (OR .51, .27-.98 CI) without effect on L-ICU and LOS. CONCLUSIONS: The use of HMP decreases PRS and EAD, specifically for marginal grafts. This is supported by a shorter LOS and a lower rate of major postoperative complications (QOE; moderate | Recommendation; Strong). NMP reduces the incidence of PRS and EAD with associated shortening in L-ICU for both DBD and DCD grafts (QOE; moderate | Recommendation; High) This technology also shortens the length of hospital stay (QOE; low | Recommendation; Strong). NRP decreases the likelihood of EAD (QOE; moderate) and the risk of PNF (QOE; low) when compared to both DBD and SRR-DCD grafts preserved in SCS. (Recommendation; Strong).


Assuntos
Transplante de Fígado , Humanos , Preservação de Órgãos , Perfusão , Fígado , Sobrevivência de Enxerto
5.
J Hepatol ; 74(4): 881-892, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32976864

RESUMO

BACKGROUND & AIMS: Early allograft dysfunction (EAD) following liver transplantation (LT) negatively impacts graft and patient outcomes. Previously we reported that the liver graft assessment following transplantation (L-GrAFT7) risk score was superior to binary EAD or the model for early allograft function (MEAF) score for estimating 3-month graft failure-free survival in a single-center derivation cohort. Herein, we sought to externally validate L-GrAFT7, and compare its prognostic performance to EAD and MEAF. METHODS: Accuracies of L-GrAFT7, EAD, and MEAF were compared in a 3-center US validation cohort (n = 3,201), and a Consortium for Organ Preservation in Europe (COPE) normothermic machine perfusion (NMP) trial cohort (n = 222); characteristics were compared to assess generalizability. RESULTS: Compared to the derivation cohort, patients in the validation and NMP trial cohort had lower recipient median MELD scores; were less likely to require pretransplant hospitalization, renal replacement therapy or mechanical ventilation; and had superior 1-year overall (90% and 95% vs. 84%) and graft failure-free (88% and 93% vs. 81%) survival, with a lower incidence of 3-month graft failure (7.4% and 4.0% vs. 11.1%; p <0.001 for all comparisons). Despite significant differences in cohort characteristics, L-GrAFT7 maintained an excellent validation AUROC of 0.78, significantly superior to binary EAD (AUROC 0.68, p = 0.001) and MEAF scores (AUROC 0.72, p <0.001). In post hoc analysis of the COPE NMP trial, the highest tertile of L-GrAFT7 was significantly associated with time to liver allograft (hazard ratio [HR] 2.17, p = 0.016), Clavien ≥IIIB (HR 2.60, p = 0.034) and ≥IVa (HR 4.99, p = 0.011) complications; post-LT length of hospitalization (p = 0.002); and renal replacement therapy (odds ratio 3.62, p = 0.016). CONCLUSIONS: We have validated the L-GrAFT7 risk score as a generalizable, highly accurate, individualized risk assessment of 3-month liver allograft failure that is superior to existing scores. L-GrAFT7 may standardize grading of early hepatic allograft function and serve as a clinical endpoint in translational studies (www.lgraft.com). LAY SUMMARY: Early allograft dysfunction negatively affects outcomes following liver transplantation. In independent multicenter US and European cohorts totaling 3,423 patients undergoing liver transplantation, the liver graft assessment following transplantation (L-GrAFT) risk score is validated as a superior measure of early allograft function that accurately discriminates 3-month graft failure-free survival and post-liver transplantation complications.


Assuntos
Transplante de Fígado , Disfunção Primária do Enxerto , Medição de Risco , Europa (Continente)/epidemiologia , Feminino , Sobrevivência de Enxerto , Humanos , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Transplante de Fígado/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde/estatística & dados numéricos , Disfunção Primária do Enxerto/diagnóstico , Disfunção Primária do Enxerto/epidemiologia , Disfunção Primária do Enxerto/terapia , Prognóstico , Traumatismo por Reperfusão/diagnóstico , Traumatismo por Reperfusão/epidemiologia , Traumatismo por Reperfusão/terapia , Reprodutibilidade dos Testes , Medição de Risco/métodos , Medição de Risco/normas , Fatores de Risco , Análise de Sobrevida , Estados Unidos/epidemiologia
6.
Br J Surg ; 108(12): 1409-1416, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34791070

RESUMO

BACKGROUND: The pressure on liver-transplant programmes has expanded the usage of extended-criteria allografts. Machine perfusion may be better than conventional static cold storage (SCS) in alleviating ischaemia-reperfusion injury in this setting. Recipient outcomes with hypothermic or normothermic machine perfusion were assessed against SCS here. METHODS: A search in MEDLINE, EMBASE and Scopus was conducted in February 2021. Primary studies investigating ex vivo machine perfusion were assessed for the following outcomes: morbidity, ICU and hospital stay, graft and patient survival rates and relative costs. Meta-analysis was performed to obtain pooled summary measures. RESULTS: Thirty-four articles involving 1742 patients were included, of which 20 were used for quantitative synthesis. Odds ratios favoured hypothermic machine perfusion (over SCS) with less early allograft dysfunction, ischaemic cholangiopathy, non-anastomotic strictures and graft loss. Hypothermic machine perfusion was associated with a shorter hospital stay and normothermic machine perfusion with reduced graft injury. Two randomized clinical trials found normothermic machine perfusion reduced major complication risks. CONCLUSION: Machine perfusion assists some outcomes with potential cost savings.


Assuntos
Transplante de Fígado , Preservação de Órgãos/métodos , Perfusão , Criopreservação , Sobrevivência de Enxerto , Humanos , Tempo de Internação , Traumatismo por Reperfusão/prevenção & controle
7.
HPB (Oxford) ; 23(11): 1656-1665, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34544628

RESUMO

INTRODUCTION: The SARS-CoV-2 pandemic presented healthcare providers with an extreme challenge to provide cancer services. The impact upon the diagnostic and treatment capacity to treat pancreatic cancer is unclear. This study aimed to identify national variation in treatment pathways during the pandemic. METHODS: A survey was distributed to all United Kingdom pancreatic specialist centres, to assess diagnostic, therapeutic and interventional services availability, and alterations in treatment pathways. A repeating methodology enabled assessment over time as the pandemic evolved. RESULTS: Responses were received from all 29 centres. Over the first six weeks of the pandemic, less than a quarter of centres had normal availability of diagnostic pathways and a fifth of centres had no capacity whatsoever to undertake surgery. As the pandemic progressed services have gradually improved though most centres remain constrained to some degree. One third of centres changed their standard resectable pathway from surgery-first to neoadjuvant chemotherapy. Elderly patients, and those with COPD were less likely to be offered treatment during the pandemic. CONCLUSION: The COVID-19 pandemic has affected the capacity of the NHS to provide diagnostic and staging investigations for pancreatic cancer. The impact of revised treatment pathways has yet to be realised.


Assuntos
COVID-19 , Neoplasias Pancreáticas , Idoso , Humanos , Neoplasias Pancreáticas/epidemiologia , Neoplasias Pancreáticas/terapia , Pandemias , SARS-CoV-2 , Reino Unido/epidemiologia
9.
Liver Transpl ; 25(10): 1503-1513, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31206217

RESUMO

Clinical adoption of normothermic machine perfusion (NMP) may be facilitated by simplifying logistics and reducing costs. This can be achieved by cold storage of livers for transportation to recipient centers before commencing NMP. The purpose of this study was to assess the safety and feasibility of post-static cold storage normothermic machine perfusion (pSCS-NMP) in liver transplantation. In this multicenter prospective study, 31 livers were transplanted. The primary endpoint was 30-day graft survival. Secondary endpoints included the following: peak posttransplant aspartate aminotransferase (AST), early allograft dysfunction (EAD), postreperfusion syndrome (PRS), adverse events, critical care and hospital stay, biliary complications, and 12-month graft survival. The 30-day graft survival rate was 94%. Livers were preserved for a total of 14 hours 10 minutes ± 4 hours 46 minutes, which included 6 hours 1 minute ± 1 hour 19 minutes of static cold storage before 8 hours 24 minutes ± 4 hours 4 minutes of NMP. Median peak serum AST in the first 7 days postoperatively was 457 U/L (92-8669 U/L), and 4 (13%) patients developed EAD. PRS was observed in 3 (10%) livers. The median duration of initial critical care stay was 3 days (1-20 days), and median hospital stay was 13 days (7-31 days). There were 7 (23%) patients who developed complications of grade 3b severity or above, and 2 (6%) patients developed biliary complications: 1 bile leak and 1 anastomotic stricture with no cases of ischemic cholangiopathy. The 12-month overall graft survival rate (including death with a functioning graft) was 84%. In conclusion, this study demonstrates that pSCS-NMP was feasible and safe, which may facilitate clinical adoption.


Assuntos
Sobrevivência de Enxerto , Transplante de Fígado/efeitos adversos , Preservação de Órgãos/métodos , Perfusão/métodos , Complicações Pós-Operatórias/epidemiologia , Adolescente , Adulto , Idoso , Aloenxertos/irrigação sanguínea , Temperatura Baixa , Doença Hepática Terminal/diagnóstico , Doença Hepática Terminal/cirurgia , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Unidades de Terapia Intensiva/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Fígado/irrigação sanguínea , Transplante de Fígado/métodos , Masculino , Pessoa de Meia-Idade , Preservação de Órgãos/efeitos adversos , Perfusão/efeitos adversos , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Isquemia Quente/efeitos adversos , Adulto Jovem
10.
Transpl Int ; 32(6): 586-597, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30980772

RESUMO

Organ preservation and re-conditioning using machine perfusion technologies continue to generate promising results in terms of viability assessment, organ utilization and improved initial graft function. Here, we summarize the latest findings and study the results of ex-vivo/ex-situ hypothermic (HMP) and normothermic machine perfusion (NMP) in the area of abdominal organ transplantation (kidney, liver, pancreas and intestine). We also consider the potential role of normothermic regional perfusion (NRP) to re-condition donors after circulatory death organs before retrieval. The findings from clinical studies reported to date suggest that machine perfusion will offer real benefits when compared with conventional cold preservation. Several randomized trials are expected to report their findings within the next 2 years which may shed light on the relative merits of different perfusion methods and could indicate which perfusion parameters may be most useful to predict organ quality and viability. Further work is needed to identify composite endpoints that are relevant for transplanted organs that have undergone machine preservation. Multi-centre trials to compare and analyse the combinations of NRP followed by HMP and/or NMP, either directly after organ retrieval using transportable devices or when back-to-base, are needed. The potential applications of machine preservation technology beyond the field of solid organ transplantation are also considered.


Assuntos
Sobrevivência de Enxerto , Preservação de Órgãos/métodos , Perfusão/métodos , Animais , Humanos , Intestinos/patologia , Intestinos/transplante , Rim/patologia , Transplante de Rim , Fígado/patologia , Transplante de Fígado , Pâncreas/patologia , Transplante de Pâncreas , Doadores de Tecidos
11.
Liver Transpl ; 24(2): 269-275, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29272051

RESUMO

In recent years, there has been growing interest in normothermic machine perfusion (NMP) as a preservation method in liver transplantation. In most countries, because of a donor organ shortage, an unacceptable number of patients die while awaiting transplantation. In an attempt to increase the number of donor organs available, transplant teams are implanting a greater number of high-risk livers, including those from donation after circulatory death, older donors, and donors with steatosis. NMP maintains the liver ex vivo on a circuit by providing oxygen and nutrition at 37°C. This permits extended preservation times, the ability to perform liver viability assessment, and the potential for liver-directed therapeutic interventions during preservation. It is hoped that this technology may facilitate the enhanced preservation of marginal livers with improved posttransplant outcomes by reducing ischemia/reperfusion injury. Clinical trials have demonstrated its short-term superiority over cold storage in terms of early biochemical liver function, and it is anticipated that it may result in increased organ utilization, helping to reduce the number of wait-list deaths. However, further studies are required to demonstrate longer-term efficacy and the impact on biliary complications as well as further knowledge to exploit and maximize the potential of this exciting new technology. Liver Transplantation 24 269-275 2018 AASLD.


Assuntos
Transplante de Fígado/métodos , Preservação de Órgãos/métodos , Perfusão/métodos , Temperatura , Doadores de Tecidos/provisão & distribuição , Animais , Sobrevivência de Enxerto , Humanos , Transplante de Fígado/efeitos adversos , Transplante de Fígado/instrumentação , Preservação de Órgãos/efeitos adversos , Preservação de Órgãos/instrumentação , Perfusão/efeitos adversos , Perfusão/instrumentação , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Listas de Espera
12.
Curr Opin Organ Transplant ; 22(3): 300-305, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28301388

RESUMO

PURPOSE OF REVIEW: Preservation of the liver via normothermic machine perfusion (NMP) is rapidly becoming an area of great academic and clinical interest. This review focuses on the benefits and limitations of NMP and where the role for static cold storage may lie. RECENT FINDINGS: Clinical studies have recently been published reporting the use of NMP in liver preservation for transplantation. They have described the technology to be well tolerated and feasible with potentially improved posttransplant outcomes. NMP facilitates extended preservation times as well as the potential to increase organ utilization through viability assessment and regeneration. However, this technology is considerably more costly than cold storage and carries significant logistical challenges. Cold storage remains the gold standard preservation for standard criteria livers with good long-term patient and graft survival. SUMMARY: NMP is an exciting new technological advancement in liver preservation, which is likely to have a positive impact in liver transplantation. However, randomized controlled trials are required to justify its inclusion into standard practice and provide evidence to support its efficacy.


Assuntos
Criopreservação/métodos , Transplante de Fígado/métodos , Fígado/patologia , Preservação de Órgãos/métodos , Perfusão/métodos , Humanos
13.
Clin Transplant ; 30(10): 1306-1313, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27460305

RESUMO

Between 2010 and 2013, we recorded 66 cases of failed organ donation after brain death (DBD) due to the excessive use of the vasoactive drugs resulting in impaired hepatic and/or renal function. To investigate the effect of extracorporeal membrane oxygenation (ECMO) in donor management, ECMO was used to provide support for DBD donors with circulatory and/or respiratory failure from 2013 to 2015. A retrospective cohort study between circulatory non-stable DBD with vasoactive drugs (DBD-drug) and circulatory non-stable DBD with ECMO (DBD-ECMO) was designed to compare the transplant outcomes. A total of 19 brain death donors were supported by ECMO. The incidence rate of post-transplant liver primary non-function (PNF) was 10% (two of 20) in DBD-drug group and zero in DBD-ECMO group. Kidney function indicators, including creatinine clearance and urine production, were significantly better in DBD-ECMO group, as well as the kidney delayed graft function (DGF) rate was found to be decreased by the use of ECMO in our study. Donation success rate increased steadily from 47.8% in 2011 to 84.6% in 2014 after the ECMO intervention. The use of ECMO in assisting circulatory and respiratory function of DBD can reduce liver and kidney injury from vasoactive drugs, thereby improving organ quality and reducing the organ discard rates.


Assuntos
Morte Encefálica , Função Retardada do Enxerto/prevenção & controle , Oxigenação por Membrana Extracorpórea , Transplante de Rim , Transplante de Fígado , Preservação de Órgãos/métodos , Coleta de Tecidos e Órgãos/métodos , Adulto , Fármacos Cardiovasculares/efeitos adversos , Função Retardada do Enxerto/induzido quimicamente , Dopamina/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Norepinefrina/efeitos adversos , Preservação de Órgãos/efeitos adversos , Avaliação de Resultados em Cuidados de Saúde , Estudos Retrospectivos , Coleta de Tecidos e Órgãos/efeitos adversos
14.
Transplant Rev (Orlando) ; 38(1): 100803, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37919138

RESUMO

The British Transplantation Society (BTS) 'Guideline on transplantation from deceased donors after circulatory death' has recently been updated and this manuscript summarises the relevant recommendations from chapters specifically related to law, ethics, donor consent and informing the recipient.


Assuntos
Obtenção de Tecidos e Órgãos , Humanos , Doadores de Tecidos , Consentimento Livre e Esclarecido
15.
Transplant Rev (Orlando) ; 38(1): 100801, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37840003

RESUMO

The British Transplantation Society (BTS) 'Guideline on transplantation from deceased donors after circulatory death' has recently been updated and this manuscript summarises the relevant recommendations in abdominal organ transplantation from Donation after Circulatory Death (DCD) donors, encompassing the chapters on liver, kidney, pancreas and islet cell transplantation.


Assuntos
Transplante de Órgãos , Obtenção de Tecidos e Órgãos , Humanos , Doadores de Tecidos , Pâncreas , Rim , Sobrevivência de Enxerto
16.
BJS Open ; 8(3)2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38869238

RESUMO

BACKGROUND: Pancreatoduodenectomy is associated with an increased incidence of surgical-site infections, often leading to a significant rise in morbidity and mortality. This trend underlines the inadequacy of traditional antibiotic prophylaxis strategies. Hence, the aim of this meta-analysis was to assess the outcomes of antimicrobial prophylaxis, comparing piperacillin/tazobactam with traditional antibiotics. METHODS: Upon registering in PROSPERO, the international prospective register of systematic reviews (CRD42023479100), a systematic search of various databases was conducted over the interval 2000-2023. This inclusive search encompassed a wide range of study types, including prospective and retrospective cohorts and RCTs. The subsequent data analysis was carried out utilizing RevMan 5.4. RESULTS: A total of eight studies involving 2382 patients who underwent pancreatoduodenectomy and received either piperacillin/tazobactam (1196 patients) or traditional antibiotics (1186 patients) as antibiotic prophylaxis during surgery were included in the meta-analysis. Patients in the piperacillin/tazobactam group had significantly reduced incidences of surgical-site infections (OR 0.43 (95% c.i. 0.30 to 0.62); P < 0.00001) and major surgical complications (Clavien-Dindo grade greater than or equal to III) (OR 0.61 (95% c.i. 0.45 to 0.81); P = 0.0008). Subgroup analysis of surgical-site infections highlighted significantly reduced incidences of superficial surgical-site infections (OR 0.34 (95% c.i. 0.14 to 0.84); P = 0.02) and organ/space surgical-site infections (OR 0.47 (95% c.i. 0.28 to 0.78); P = 0.004) in the piperacillin/tazobactam group. Further, the analysis demonstrated significantly lower incidences of clinically relevant postoperative pancreatic fistulas (grades B and C) (OR 0.67 (95% c.i. 0.53 to 0.83); P = 0.0003) and mortality (OR 0.51 (95% c.i. 0.28 to 0.91); P = 0.02) in the piperacillin/tazobactam group. CONCLUSION: Piperacillin/tazobactam as antimicrobial prophylaxis significantly lowers the risk of postoperative surgical-site infections, major surgical complications (complications classified as Clavien-Dindo grade greater than or equal to III), clinically relevant postoperative pancreatic fistulas (grades B and C), and mortality, hence supporting the implementation of piperacillin/tazobactam for surgical prophylaxis in current practice.


Assuntos
Antibacterianos , Antibioticoprofilaxia , Pancreaticoduodenectomia , Combinação Piperacilina e Tazobactam , Infecção da Ferida Cirúrgica , Humanos , Pancreaticoduodenectomia/efeitos adversos , Combinação Piperacilina e Tazobactam/uso terapêutico , Infecção da Ferida Cirúrgica/prevenção & controle , Antibacterianos/uso terapêutico , Piperacilina/uso terapêutico
17.
Trials ; 25(1): 386, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38886851

RESUMO

BACKGROUND: Liver disease is the third leading cause of premature death in the UK. Transplantation is the only successful treatment for end-stage liver disease but is limited by a shortage of suitable donor organs. As a result, up to 20% of patients on liver transplant waiting lists die before receiving a transplant. A third of donated livers are not suitable for transplant, often due to steatosis. Hepatic steatosis, which affects 33% of the UK population, is strongly associated with obesity, an increasing problem in the potential donor pool. We have recently tested defatting interventions during normothermic machine perfusion (NMP) in discarded steatotic human livers that were not transplanted. A combination of therapies including forskolin (NKH477) and L-carnitine to defat liver cells and lipoprotein apheresis filtration were investigated. These interventions resulted in functional improvement during perfusion and reduced the intrahepatocellular triglyceride (IHTG) content. We hypothesise that defatting during NMP will allow more steatotic livers to be transplanted with improved outcomes. METHODS: In the proposed multi-centre clinical trial, we will randomly assign 60 livers from donors with a high-risk of hepatic steatosis to either NMP alone or NMP with defatting interventions. We aim to test the safety and feasibility of the defatting intervention and will explore efficacy by comparing ex-situ and post-reperfusion liver function between the groups. The primary endpoint will be the proportion of livers that achieve predefined functional criteria during perfusion which indicate potential suitability for transplantation. These criteria reflect hepatic metabolism and injury and include lactate clearance, perfusate pH, glucose metabolism, bile composition, vascular flows and transaminase levels. Clinical secondary endpoints will include proportion of livers transplanted in the two arms, graft function; cell-free DNA (cfDNA) at follow-up visits; patient and graft survival; hospital and ITU stay; evidence of ischemia-reperfusion injury (IRI); non-anastomotic biliary strictures and recurrence of steatosis (determined on MRI at 6 months). DISCUSSION: This study explores ex-situ pharmacological optimisation of steatotic donor livers during NMP. If the intervention proves effective, it will allow the safe transplantation of livers that are currently very likely to be discarded, thereby reducing waiting list deaths. TRIAL REGISTRATION: ISRCTN ISRCTN14957538. Registered in October 2022.


Assuntos
Fígado Gorduroso , Transplante de Fígado , Perfusão , Ensaios Clínicos Controlados Aleatórios como Assunto , Humanos , Transplante de Fígado/métodos , Perfusão/métodos , Fígado Gorduroso/terapia , Doadores de Tecidos/provisão & distribuição , Fígado/patologia , Estudos Multicêntricos como Assunto , Preservação de Órgãos/métodos , Fatores de Tempo , Resultado do Tratamento
18.
Transplant Rev (Orlando) ; 37(4): 100791, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37598591

RESUMO

Recipient outcomes after transplantation with organs from donation after circulatory death (DCD) donors can compare favourably and even match recipient outcomes after transplantation with organs from donation after brain death donors. Success is dependent upon establishing common practices and accepted protocols that allow the safe sharing of DCD organs and maximise the use of the DCD donor pool. The British Transplantation Society 'Guideline on transplantation from deceased donors after circulatory death' has recently been updated. This manuscript summarises the relevant recommendations from chapters specifically related to organ donation.


Assuntos
Transplante de Órgãos , Obtenção de Tecidos e Órgãos , Humanos , Doadores de Tecidos , Morte Encefálica , Sobrevivência de Enxerto
19.
Transplant Rev (Orlando) ; 37(4): 100794, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37660415

RESUMO

Maximising organ utilisation from donation after circulatory death (DCD) donors could help meet some of the shortfall in organ supply, but it represents a major challenge, particularly as organ donors and transplant recipients become older and more medically complex over time. Success is dependent upon establishing common practices and accepted protocols that allow the safe sharing of DCD organs and maximise the use of the DCD donor pool. The British Transplantation Society 'Guideline on transplantation from deceased donors after circulatory death' has recently been updated. This manuscript summarises the relevant recommendations from chapters specifically related to transplantation of cardiothoracic organs.


Assuntos
Transplante de Órgãos , Obtenção de Tecidos e Órgãos , Humanos , Doadores de Tecidos , Transplantados , Sobrevivência de Enxerto
20.
Prog Transplant ; 33(1): 61-68, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36537056

RESUMO

Introduction: Too small or too big liver grafts for recipient's size has detrimental effects on transplant outcomes. Research Questions: The purpose was to correlate donor-recipient body surface area ratio or body surface area index with recipient survival, graft survival, hepatic artery or portal vein, or vena cava thrombosis. High and low body surface area index cut-off points were determined. Design: There were 11,245 adult recipients of first deceased donor whole liver-only grafts performed in the UK from January 2000 until June 2020. The transplants were grouped according to the body surface area index and compared to complications, graft and recipient survival. Results: The body surface area index ranged from 0.491 to 1.691 with a median of 0.988. The body surface area index > 1.3 was associated with a higher rate of portal vein thrombosis within the first 3 months (5.5%). This risk was higher than size-matched transplants (OR: 2.878, 95% CI: 1.292-6.409, P = 0.01). Overall graft survival was worse in transplants with body surface area index ≤ 0.85 (HR: 1.254, 95% CI: 1.051-1.497, P = 0.012) or body surface area index > 1.4 (HR: 3.704, 95% CI: 2.029-6.762, P < 0.001) than those with intermediate values. The graft survival rates were reduced by 2% for cases with body surface area index ≤ 0.85 but were decreased by 20% for cases with body surface area index > 1.4. These findings were confirmed by bootstrap internal validation. No statistically significant differences were detected for hepatic artery thrombosis, occlusion of hepatic veins/inferior vena cava or recipient survival. Conclusions: Donor-recipient size mismatch affects the rates of portal vein thrombosis within the first 3 months and overall graft survival in deceased-donor liver transplants.


Assuntos
Transplante de Fígado , Adulto , Humanos , Doadores Vivos , Superfície Corporal , Fígado , Reino Unido , Sobrevivência de Enxerto , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA