Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Klin Monbl Augenheilkd ; 241(8): 923-943, 2024 Aug.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-38242162

RESUMO

Although the safety of phakic intraocular lenses (pIOLs) has been continuously improved over 70-years of development, high endothelial cell losses can occur even with current pIOL models. Numerous studies have demonstrated that the distance of a pIOL to the corneal endothelium plays a crucial role in the extent of endothelial cell loss. For this reason alone, higher endothelial cell loss tends to be observed with anterior chamber lenses than with posterior chamber lenses. Adequate preoperative anterior chamber depth is essential, at least for iris-fixed pIOLs, in order to ensure a safe distance from the endothelium. However, the anterior chamber becomes shallower with age and therefore it may be useful to consider patient age in the safety criteria. Although endothelial cell loss is generally low with current pIOL models, regular monitoring of the endothelial cell density remains essential due to large interindividual differences in patients with pIOLs. If the endothelial cell loss is greater than expected and the follow-up visits confirm the trend, the pIOL should be explanted without delay. The endothelial reserve should be considered on an individual basis by taking into account patient age, physiological endothelial cell loss, and loss due to further surgery. With careful indication and long-term patient care, pIOLs remain a safe treatment option.


Assuntos
Perda de Células Endoteliais da Córnea , Lentes Intraoculares Fácicas , Humanos , Perda de Células Endoteliais da Córnea/etiologia , Perda de Células Endoteliais da Córnea/patologia , Endotélio Corneano/patologia , Resultado do Tratamento , Medicina Baseada em Evidências
2.
Klin Monbl Augenheilkd ; 241(8): 893-904, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39146574

RESUMO

In recent decades, technical advancements in lens surgery have considerably improved safety and refractive outcomes. This has led to a much broader range of indications for refractive lens exchange (RLE). Effective restoration of uncorrected distance and near visual acuity is possible with modern presbyopia correcting intraocular lenses (IOLs). Hyperopic patients who are fully presbyopic were identified as ideal candidates for RLE. For myopic patients, an increased risk of retinal detachment has been reported, which leads to a higher threshold to perform RLE in this patient group. The most frequent postoperative complications include posterior capsular opacification, deviation from the target refraction and cystoid macular edema. Thus, adequate planning of surgery, careful patient selection, as well as comprehensive counseling are crucial for successful RLE.


Assuntos
Lentes Intraoculares , Humanos , Resultado do Tratamento , Presbiopia/cirurgia , Presbiopia/terapia , Implante de Lente Intraocular/métodos , Acuidade Visual , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Medicina Baseada em Evidências
3.
Klin Monbl Augenheilkd ; 241(8): 917-922, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39146576

RESUMO

Intravitreal injections (IVI s) have gained increased popularity in the past decades and are used to treat a multitude of ailments. In 2010, the total number of IVI s surpassed the number of cataract surgeries performed, making it the most common procedure in ophthalmology. As the number of injections increases, so does the number of injected-related complications. While complications in the posterior segment, such as retinal detachment or endophthalmitis, are detrimental to visual function and have therefore been well documented, IVI s can also lead to complications in the anterior segment. These include hyphema, inflammation of the sterile anterior segment (incidence rate of 0.05 to 1.1% depending on the drug), implant migration with corneal decompensation (incidence rate of 0.43%), iatrogenic lens damage (incidence rate of 0.07%), accelerated cataract formation (up to 50% for steroids and 10.9% for anti-VEGF), and an increased complication rate during subsequent cataract surgery (up to 4% per IVI). Most of these complications occur immediately and have a good prognosis if treated correctly. However, the increased risk of complications during subsequent surgery demonstrates that IVI s can also have long-term complications, a topic that needs to be explored further in future research projects.


Assuntos
Segmento Anterior do Olho , Injeções Intravítreas , Humanos , Injeções Intravítreas/efeitos adversos , Segmento Anterior do Olho/diagnóstico por imagem , Hifema/etiologia , Catarata/induzido quimicamente , Endoftalmite/etiologia , Complicações Pós-Operatórias/etiologia
5.
Ophthalmologie ; 2024 Jul 08.
Artigo em Alemão | MEDLINE | ID: mdl-38977490

RESUMO

Intraocular lenses (IOL) featuring complex optical designs can pose a challenge in understanding their performance, which may hinder making an informed decision when selecting suitable lenses for patients. This underlines the importance of collecting optical quality data of IOLs and making them available. The deployment of benchtop systems for IOL testing offers not only insights into the design features of various IOL solutions but also provides a platform for objective comparisons of special optics designs, including information about their susceptibility to photic phenomena. Recent advances in IOL testing have improved the ability to predict functional effects on visual acuity and contrast sensitivity from objective optical quality metrics. This, for instance, can be used to study monofocal lenses and the impact of asphericity on vision and IOLs tolerance to misalignment. Monofocal-plus IOLs consistently show only a slight improvement in the depth of focus when tested on the optical bench and in clinical settings. Although the pupil dependence found in this technology may limit the advantages of monofocal-plus over standard monofocal technology to extend the range of vision, it is the key to reduce photic phenomena. Refractive and diffractive extended depth of focus (EDOF) IOLs can effectively enhance intermediate vision, with the latter offering a slightly broader depth of focus but potentially increasing the risk of dysphotopsia. However, the limitation of EDOF IOLs is that they often fail to deliver spectacle independence for reading, which can be overcome by trifocal technology. Still, the available trifocal IOLs differ in their location of intermediate and near foci and the susceptibility to produce glare effects. Therefore, the knowledge from optical benchtop testing of IOLs can support optimizing the IOL selection by aligning the patient's visual needs with the IOL's properties, setting the right expectations, and assessing the risk profile for the occurrence of photic phenomena, potentially leading to improved decision-making.

6.
Ophthalmologie ; 2024 Jul 17.
Artigo em Alemão | MEDLINE | ID: mdl-39017699

RESUMO

A multitude of available intraocular lens (IOL) models enable a personalized approach to presbyopia correction in order to meet each patient's needs. This review article discusses more complex approaches which can be useful in selected cases. The concept of reversible trifocality enables correction of presbyopia using a supplementary intraocular lens (IOL), which can be removed if necessary (e.g., intolerance to multifocal optics). The use of capsulotomy-fixated IOLs enables high precision for positioning of the lens and better stability compared to conventional capsular bag-fixated IOLs, which can be particularly advantageous in multifocal optics. The mix and match concept enables a combination of different IOLs with various optical principles to achieve the desired binocular effect. Binocular IOL systems, which consist of two complementary IOLs, can be seen as a further development of the mix and match concept. Knowledge of the available options and their application can further improve correction of presbyopia.

7.
Cornea ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38478752

RESUMO

PURPOSE: The purpose of this study was to determine whether the Scheimpflug tomographically normal fellow eyes of keratoconus patients are also classified as normal using an ectasia screening algorithm based on anterior segment optical coherence tomography (AS-OCT). METHODS: This monocentric cross-sectional study included 22 very asymmetric ectasia patients with tomographically significant keratoconus in 1 eye and normal Scheimpflug tomography in the fellow eye. Twenty-two eyes of 22 healthy subjects served as a control group. We performed corneal tomography using Pentacam AXL (Oculus, Wetzlar, Germany) and used Belin/Ambrósio Enhanced Ectasia total deviation index as well as Belin ABCD keratoconus classification to identify Scheimpflug tomographically normal eyes. We also performed AS-OCT using Anterion (Heidelberg Engineering, Heidelberg, Germany) and analyzed for the presence of ectasia using the Screening Corneal Objective Risk of Ectasia (SCORE) algorithm, with positive values indicating ectasia suspect tomography. RESULTS: The SCORE value was positive in 9.1% (n = 2) of the healthy eyes, in 45.5% (n = 10) of the Scheimpflug tomographically normal eyes of keratoconus patients and in all eyes (n = 22) with tomographically significant keratoconus. The Scheimpflug tomographically normal eyes of keratoconus patients had higher SCORE values compared with healthy controls (P < 0.001). The median (interquartile range) SCORE value was -1.7 (1.3) in healthy controls, -0.5 (2.2) in Scheimpflug tomographically normal eyes of keratoconus patients, and 11.1 (11.0) in tomographically significant keratoconus eyes. CONCLUSIONS: The Scheimpflug tomographically normal fellow eyes of keratoconus patients had higher AS-OCT-based SCORE values than healthy controls, with positive SCORE values found in 46% of the eyes, indicating early tomographic ectatic changes.

8.
Eye (Lond) ; 2024 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-39003429

RESUMO

PURPOSE: To develop and test a parameter for early keratoconus screening by quantifying the localized epithelial thickness differences in keratoconic eyes. METHODS: The cross-sectional study included 189 eyes of 116 subjects in total: 86 eyes of 54 keratoconus patients with bilateral ectasia and 40 eyes of 20 healthy subjects in the parameter-development dataset and 42 eyes of 21 keratoconus patients with asymmetric ectasia and 21 eyes of 21 healthy subjects in the parameter-validation dataset. Epithelial thickness maps were obtained using anterior segment optical coherence tomography and the inter-zonal epithelial thickness differences were calculated. The developed parameter was tested in keratoconus patients with asymmetric ectasia. RESULTS: Compared to healthy controls, the inferior-temporal and global inter-zonal epithelial thickness differences were higher not only in eyes with tomographically significant keratoconus (median [interquartile range] of 4.42 [3.13] µm vs. 0.78 [0.42] µm, p < 0.001, and 3.05 [1.51] µm vs. 1.07 [0.26] µm, p < 0.001, respectively), but also in tomographically normal keratoconus fellow eyes (1.36 [0.85] µm vs. 0.78 [0.42] µm, p = 0.005, and 1.31 [0.32] µm vs. 1.07 [0.26] µm, p = 0.01, respectively). The inferior-temporal inter-zonal epithelial thickness differences had an area under the receiver operating characteristic curve (95% confidence interval) of 0.991 (0.972-1) for detecting tomographically significant keratoconus and 0.749 (0.598-0.901) for differentiating between tomographically normal keratoconus fellow eyes and healthy controls. CONCLUSIONS: The inter-zonal epithelial thickness differences are increased in keratoconus fellow eyes which still have a normal Scheimpflug corneal tomography, and therefore may serve as a useful parameter to detect early ectatic changes.

9.
J Cataract Refract Surg ; 50(4): 413-419, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38237073

RESUMO

PURPOSE: To objectively quantify glare of intraocular lenses (IOLs) using a diffractive principle to extend the visual range and to identify models with increased susceptibility to inducing glare. SETTING: David J Apple Laboratory, Heidelberg, Germany. DESIGN: Laboratory investigation. METHODS: Glare was assessed by means of a straylight parameter with a standard C-Quant intended for 7 degrees. In addition, 2 C-Quant modifications were used to test lower angles (ie, 2.5 degrees and 3.5 degrees). The following IOL models were assessed: PanOptix, AT Lisa Tri, Synergy, and Triumf, the latter 2 with chromatic aberration correction at distance. Straylight from trifocal IOLs was compared against a monofocal W-60R lens. The C-Quant test was performed through the studied IOLs by using additional optical components attached to their ocular. RESULTS: Straylight (deg 2 sr -1 ) of the control was <1 at all tested angles, with the trifocal models showing comparable straylight at 7 degrees. At 3.5 degrees, Triumf's straylight increased to 15.5 ± 0.6, followed by Synergy (6.2 ± 1.1), PanOptix (4.1 ± 0.3), and AT Lisa Tri (2.0 ± 0.8). The chromatic aberration-correcting models demonstrated correspondingly higher straylight (Synergy: 18.8 ± 1.3; Triumf: 17.3 ± 0.5) at 2.5 degrees compared with PanOptix (4.3 ± 0.4), AT Lisa Tri (2.1 ± 0.1), and monofocal IOLs yielding minimal or no increase. CONCLUSIONS: Trifocal IOLs induced increased straylight, but it was limited to lower angles, which may cause difficulties detecting these effects using a standard clinical approach. The latest IOL designs featuring chromatic aberration correction at far focus seem more susceptible than the established trifocal IOLs to inducing a glare phenomenon.


Assuntos
Cristalino , Lentes Intraoculares , Presbiopia , Humanos , Ofuscação , Presbiopia/cirurgia , Óculos , Desenho de Prótese
10.
J Refract Surg ; 40(1): e48-e56, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38190558

RESUMO

PURPOSE: To evaluate the biomechanical longitudinal variability and progression of tomographically normal fellow eyes of patients with keratoconus. METHODS: Of 513 patients with keratoconus, 30 patients with tomographically normal fellow eyes were included in this study. Tomographic and biomechanical parameters of the Pentacam and Corvis ST (Oculus Optikgeräte GmbH) were analyzed in multiple follow-up examinations, including the ABCD grading, Belin/Ambrósio Enhanced Ectasia total deviation index (BAD-D), Corvis Biomechanical Index (CBI), Corvis Biomechanical Factor (CBiF), and Tomographic and Biomechanical Index (TBI). A mixed regression model was applied. The results were compared to a healthy control group (n = 17) and a keratoconus group (n = 20). RESULTS: Within a maximum observation period of 3.3 years, no fellow eye (0%) showed a progression to tomographically evident keratoconus. No significant change in tomographic or biomechanical parameters was detected over the study period. The indices BAD-D, CBI, CbiF, and TBI exhibited a certain variability over time, whereas the tomographic ABC parameters and maximum keratometry barely changed. This was also shown in the control group and for all parameters in the keratoconus group, except the TBI. CONCLUSIONS: During the observation period none of the normal fellow eyes progressed to tomographically detectable keratoconus. However, biomechanical parameters CBI, CbiF, and TBI showed pathological values in 43.3% of eyes and certain variability. Subsequent studies with a longer observation period are warranted to confirm the biomechanical trends seen in this study and to rate the ability of single measurements to diagnose early keratoconus. [J Refract Surg. 2024;40(1):e48-e56.].


Assuntos
Ceratocone , Humanos , Ceratocone/diagnóstico , Dilatação Patológica/diagnóstico
11.
Am J Ophthalmol ; 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39117256

RESUMO

PURPOSE: To evaluate visual outcomes and patient-reported results after bilateral femtosecond-laser assisted refractive lens exchange (RLE) with the implantation of a diffractive trifocal intraocular lens (IOL). DESIGN: Prospective interventional case series METHODS: A study of 27 patients (54 eyes) implanted with the Clareon PanOptix (Alcon) multifocal IOL during femtosecond laser assisted RLE in a university hospital setting. The uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuity at 60cm, uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity at 40cm and 33cm were evaluated at three months postoperatively and compared with the preoperative values. In addition, we assessed the postoperative defocus curve, mesopic and photopic contrast sensitivity, and patient-reported spectacle independence. RESULTS: The mean postoperative binocular UDVA was -0.02±0.06 logMAR and CDVA was -0.11±0.05 logMAR. The UIVA was -0.07±0.05 logMAR and DCIVA was -0.07±0.07 logMAR. The UNVA at 40cm was 0.03±0.09 logMAR and DCNVA was -0.02±0.06 logMAR; and, at 33cm UNVA was 0.14±0.10 logMAR and DCNVA was 0.11±0.08 logMAR. In comparison to the preoperative binocular CDVA (-0.12±0.08 logMAR), no statistically significant change was observed (p=1.0), while all the other binocular visual acuities improved (p<0.01). In the mean binocular defocus curve, the visual acuity was better than 0.10 logMAR in the range between +0.5 D and -3.0 D. The mean contrast sensitivity was within the normal range, and most patients reported complete spectacle independence. CONCLUSION: The RLE surgery improved uncorrected visual acuity at far, intermediate and near distances without negatively affecting the CDVA. Patients achieved a high level of spectacle independence.

12.
J Cataract Refract Surg ; 49(1): 84-90, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36325833

RESUMO

PURPOSE: To evaluate the ARTIS Symbiose complementary intraocular lens (IOL) system, consisting of the MID and PLUS models, in comparison with a conventional trifocal IOL (AcrySof IQ PanOptix). SETTING: The David J. Apple Center for Vision Research, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. DESIGN: Laboratory investigation. METHODS: Modulation and phase transfer functions were obtained in polychromatic light using an optical bench setup. Simulated visual acuity (VA) values were derived from optical quality metrics weighted by neural contrast sensitivity. United States Air Force (USAF) chart images were acquired and processed. Furthermore, the light distribution beyond the center of a polychromatic point spread function was assessed. RESULTS: The peak simulated VA values of ARTIS Symbiose MID were at 0 diopters (D) of defocus (-0.02 logMAR) and at -1.5 D (0.00 logMAR); of ARTIS Symbiose PLUS, they were at 0 D of defocus (-0.01 logMAR) and at -2.5 D (0.01 logMAR). AcrySof IQ PanOptix demonstrated 3 peaks: at 0 D of defocus (-0.02 logMAR), at -1.75 D (0.03 logMAR), and at -2.5 D (0.02 logMAR). The summation of USAF chart images in the simulated binocular IOL system produced a slightly better image quality at -1.0 D and -1.5 D than AcrySof IQ PanOptix. The IOLs yielded comparable light spread across the studied range except for a localized intensity spike of the ARTIS Symbiose IOLs. CONCLUSIONS: The complementary IOL system may yield better monocular intermediate VA compared with the conventional trifocal IOL. However, the effect of binocular summation in terms of VA and the perception of photic phenomena still needs to be investigated.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Refração Ocular , Pseudofacia , Implante de Lente Intraocular/métodos , Visão Binocular , Benchmarking , Desenho de Prótese , Estudos Prospectivos , Satisfação do Paciente
13.
J Refract Surg ; 39(10): 676-682, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37824299

RESUMO

PURPOSE: To evaluate the outcomes of cataract surgery with intraocular lens (IOL) implantation in patients who underwent intrastromal femtosecond laser treatment of presbyopia (INTRACOR). METHODS: This was an interventional case series of 8 patients (10 eyes) who presented for cataract surgery 6.1 ± 3.2 years (mean ± standard deviation [SD]) after INTRACOR (Technolas Perfect Vision GmbH) treatment. A monofocal IOL was implanted in 9 eyes (7 patients) and a small-aperture IOL was implanted in 1 eye. The IOL power was calculated without adjustments using biometry obtained after the INTRACOR treatment. For additional calculations, keratometry obtained before the INTRACOR treatment was used. Postoperative examinations included visual acuity testing, manifest refraction, defocus curve, ocular biometry, corneal tomography, aberrometry, anterior segment optical coherence tomography, and slit-lamp examination. RESULTS: After the cataract surgery, the mean ± SD uncorrected distance visual acuity was 0.37 ± 0.17 logMAR, the corrected distance visual acuity was 0.10 ± 0.10 logMAR, and the manifest refraction spherical equivalent, adjusted to infinity, was +0.39 ± 0.63 diopters (D). Intermediate and near visual acuity, both uncorrected and distance-corrected, and distance-corrected defocus curves varied considerably among patients. Using biometry performed after INTRACOR, the traditional IOL power calculation formulas produced hyperopic outcomes, with the mean ± SD prediction error ranging from +0.72 ± 0.34 to +0.96 ± 0.41 D. Although the mean ± SD prediction error decreased (range: -0.34 ± 0.56 to -0.15 ± 0.53 D) when using keratometry obtained before INTRACOR, the accuracy remained low due to high variability. CONCLUSIONS: In patients with cataract who had previous INTRACOR treatment, IOL power calculation could be inaccurate, with a tendency toward hyperopic outcomes. These results require confirmation in more extensive studies. [J Refract Surg. 2023;39(10):676-682.].


Assuntos
Catarata , Lentes Intraoculares , Presbiopia , Humanos , Presbiopia/cirurgia , Refração Ocular , Acuidade Visual , Lasers
14.
Diagnostics (Basel) ; 13(15)2023 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-37568866

RESUMO

Preoperative and postoperative diagnostics play an important role in ensuring the safety of patients with phakic intraocular lenses (pIOLs). The risk of endothelial cell loss can be addressed by regularly measuring the endothelial cell density using specular microscopy and considering the endothelial cell loss rate and the endothelial reserve in accordance with the patient's age when deciding whether to explant a pIOL. The anterior chamber morphometrics, including the anterior chamber depth and the distance between the pIOL and the endothelium, measured using Scheimpflug tomography and anterior segment optical coherence tomography (AS-OCT), can help to assess the risk of the endothelial cell loss. In patients undergoing posterior chamber pIOL implantation, accurate prediction of the vault and its postoperative measurements using AS-OCT or Scheimpflug tomography are important when assessing the risk of anterior subcapsular cataract and secondary glaucoma. Novel approaches based on ultrasound biomicroscopy and AS-OCT have been proposed to increase the vault prediction accuracy and to identify eyes in which prediction errors are more likely. Careful patient selection and regular postoperative follow-up visits can reduce the complication risk and enable early intervention if a complication occurs.

15.
Diagnostics (Basel) ; 13(10)2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-37238287

RESUMO

We evaluated the influence of intraocular lens (IOL) opacification on the optical performance of explanted hydrophilic acrylic IOLs. We performed a laboratory analysis of 32 Lentis LS-502-1 (Oculentis GmbH, Berlin, Germany) IOLs, explanted due to opacification, in comparison with six clear unused samples of the same IOL model. Using an optical bench setup, we obtained modulation transfer function (MTF), Strehl ratio, two-dimensional MTF, and United States Air Force (USAF) chart images. In addition, we assessed light transmission through the IOLs. The MTF values of opacified IOLs at 3-mm aperture were similar to those of clear lenses, with the median (interquartile range) values of 0.74 (0.01) vs. 0.76 (0.03) at the spatial frequency of 50 line pairs per millimeter in clear and opacified IOLs, respectively. The Strehl ratio of opacified lenses was not lower than that of clear lenses. The USAF-chart analysis showed a considerable reduction in brightness in opacified IOLs. The median (interquartile range) relative light transmission of opacified IOLs in comparison to clear lenses was 55.6% (20.8%) at the aperture size of 3 mm. In conclusion, the explanted opacified IOLs had comparable MTF values to those of clear lenses but significantly reduced light transmission.

16.
Eur J Ophthalmol ; : 11206721231204382, 2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37750504

RESUMO

PURPOSE: We evaluated implantation behavior and injector damage of two different IOL injector systems, the Multisert and the AutonoMe. DESIGN: Prospective, randomized, comparative study with laboratory investigation. METHODS: We examined used injectors from 48 bilateral cataract cases and assessed video recordings of each Implantation. All eyes were intraindividually randomized for treatment with one of the two IOL injectors. Implantation videos were reviewed for inadvertent events and the time for different implantation steps was determined. The injector nozzle tips were examined using light and scanning electron microscopy (SEM). Damage was graded using the Heidelberg Score for IOL injector damage (HeiScore). Three months postoperatively, IOLs were assessed for material changes. RESULTS: Implantation was without critical events in 96 of 96 eyes. Mean implantation time was 41.90 ± 7.11 s with the Multisert and 52.22 ± 12.06 s with the AutonoMe. In the AutonoMe group, we observed 4 eyes (8.3%) with a failed docking attempt, 28 eyes (58.3%) with a haptic adherence, one case (2.1%) of straight leading haptic and 2 cases (4.2%) of intrawound IOL manipulation. There were no events observed in the Multisert group. The mean HeiScore values were 0.87 ± 0.61 and 3.68 ± 0.47 for the AutonoMe and Multisert. 3 months postoperatively, IOL material changes were absent. CONCLUSIONS: Both injectors allowed safe and controlled implantation. Using Multisert, implantation behavior was more consistent. The injectors showed different damage profiles with a higher damage score for the Multisert.The study is registered at the German Clinical Trials Register (Deutsches Register Klinischer Studien; reference number: DRKS00007837).

17.
Ophthalmologe ; 119(1): 89-93, 2022 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-34453190

RESUMO

Relative anterior microphthalmos, nanophthalmos and high-grade hyperopia are small eyes with different characteristic morphological relationships between the anterior segment and axis length. This article discusses the intraoperative challenges and surgical approaches to solutions for cataract operations in patients with one of the three named morphological alterations. Additionally, the article addresses possible comorbidities including glaucoma and preoperative planning.


Assuntos
Catarata , Hiperopia , Microftalmia , Facoemulsificação , Catarata/complicações , Humanos , Hiperopia/cirurgia , Implante de Lente Intraocular , Microftalmia/complicações , Microftalmia/cirurgia
18.
Am J Ophthalmol Case Rep ; 25: 101262, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35112014

RESUMO

An 81-year-old patient was referred for an intraocular lens (IOL) exchange surgery because of a presumed IOL opacification. Using diagnostic imaging techniques such as anterior segment optical coherence tomography (OCT) and Scheimpflug imaging, we revealed that the presumed IOL opacification was in fact a liquefied aftercataract. As a result, an intraocular surgery was avoided and the patient was successfully treated with a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy.

19.
Am J Ophthalmol Case Rep ; 26: 101511, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35464676

RESUMO

Purpose: To present a case of a 62-year-old patient implanted with multifocal intraocular lenses (IOLs) who underwent a bilateral IOL exchange due to positive dysphotopsia. In an attempt to reduce the symptoms and compensate for the loss of multifocality, we implanted an aspheric monofocal IOL with enhanced intermediate function in one eye and a spherical monofocal IOL in the other eye. Observations: The patient presented with complaints of halo and glare, measured with a simulator, following the implantation of segmented multifocal IOLs two years earlier. The uncorrected distance visual acuity (UDVA) was 20/20 in both eyes. Before presentation at our clinic, a laser capsulotomy had been performed on the right eye. We proceeded with a bilateral IOL exchange. Because of capsular insufficiency in the right eye, we implanted a spherical monofocal three-piece IOL in the ciliary sulcus with optic capture. In the left eye, we used a monofocal IOL with an enhanced intermediate function. Two weeks postoperatively, UDVA (monocularly) was 20/20 in OD and OS, the uncorrected intermediate visual acuity (UIVA) was 20/32, and the uncorrected near visual acuity (UNVA) was 20/50. Binocularly, UDVA was 20/20, UIVA was 20/25 and UNVA was 20/25. The patient reported a marked decrease in halos and glare. Conclusions and importance: When planning IOL exchange surgery, in cases of intolerance to multifocal IOLs, the clinician should consider the dilemma of loss of multifocality. Recent developments in monofocal IOL technology present new options to improve visual function in cases of multifocal IOL explantation.

20.
Diagnostics (Basel) ; 12(1)2022 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-35054331

RESUMO

The aim of this prospective clinical study was to establish and verify an adaptation for axial length (AL) measurement in silicone oil (SO)-filled pseudophakic eyes with a Scheimpflug and partial coherence interferometry (PCI)-based biometer. The AL was measured with a Pentacam AXL (OCULUS Optikgeräte GmbH, Wetzler, Germany) and IOLMaster 700 (Carl Zeiss Meditec, Jena, Germany). The coefficients of variation (CoV) and the mean systematic difference (95% confidence interval (CI)) between the devices were calculated. After implementing a setting for measuring AL in tamponaded eyes with a Pentacam based on data of 29 eyes, another 12 eyes were examined for verification. The mean AL obtained with the Pentacam was 25.53 ± 1.94 mm (range: 21.70 to 30.76 mm), and with IOLMaster, 24.73 ± 1.97 mm (ranged 20.84 to 29.92 mm), resulting in a mean offset of 0.80 ± 0.08 mm (95% CI: 0.77, 0.83 mm), p < 0.001. The AL values of both devices showed a strong linear correlation (r = 0.999). Verification data confirmed good agreement, with a statistically and clinically non-significant mean difference of 0.02 ± 0.04 (95% CI: -0.01, 0.05) mm, p = 0.134. We implemented a specific adaptation for obtaining reliable AL values in SO-filled eyes with the Pentacam AXL.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA