Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Surg Innov ; 31(5): 563-566, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38905568

RESUMO

Plastic surgeons routinely use 3D-models in their clinical practice, from 3D-photography and surface imaging to 3D-segmentations from radiological scans. However, these models continue to be viewed on flattened 2D screens that do not enable an intuitive understanding of 3D-relationships and cause challenges regarding collaboration with colleagues. The Metaverse has been proposed as a new age of applications building on modern Mixed Reality headset technology that allows remote collaboration on virtual 3D-models in a shared physical-virtual space in real-time. We demonstrate the first use of the Metaverse in the context of reconstructive surgery, focusing on preoperative planning discussions and trainee education. Using a HoloLens headset with the Microsoft Mesh application, we performed planning sessions for 4 DIEP-flaps in our reconstructive metaverse on virtual patient-models segmented from routine CT angiography. In these sessions, surgeons discuss perforator anatomy and perforator selection strategies whilst comprehensively assessing the respective models. We demonstrate the workflow for a one-on-one interaction between an attending surgeon and a trainee in a video featuring both viewpoints as seen through the headset. We believe the Metaverse will provide novel opportunities to use the 3D-models that are already created in everyday plastic surgery practice in a more collaborative, immersive, accessible, and educational manner.


Assuntos
Imageamento Tridimensional , Microcirurgia , Procedimentos de Cirurgia Plástica , Humanos , Procedimentos de Cirurgia Plástica/educação , Procedimentos de Cirurgia Plástica/métodos , Microcirurgia/educação , Microcirurgia/métodos , Realidade Virtual , Modelos Anatômicos , Realidade Aumentada
2.
J Reconstr Microsurg ; 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39038461

RESUMO

BACKGROUND: Microsurgical breast reconstruction using abdominal tissue is a complex procedure, in part, due to variable vascular/perforator anatomy. Preoperative computed tomography angiography (CTA) has mitigated this challenge to some degree; yet it continues to pose certain challenges. The ability to map perforators with Mixed Reality has been demonstrated in case studies, but its accuracy has not been studied intraoperatively. Here, we compare the accuracy of "HoloDIEP" in identifying perforator location (vs. Doppler ultrasound) by using holographic 3D models derived from preoperative CTA. METHODS: Using a custom application on HoloLens, the deep inferior epigastric artery vascular tree was traced in 15 patients who underwent microsurgical breast reconstruction. Perforator markings were compared against the 3D model in a coordinate system centered on the umbilicus. Holographic- and Doppler-identified markings were compared using a perspective-corrected photo technique against the 3D model along with measurement of duration of perforator mapping for each technique. RESULTS: Vascular points in HoloDIEP skin markings were -0.97 ± 6.2 mm (perforators: -0.62 ± 6.13 mm) away from 3D-model ground-truth in radial length from the umbilicus at a true distance of 10.81 ± 6.14 mm (perforators: 11.40 ± 6.15 mm). Absolute difference in radial distance was twice as high for Doppler markings compared with Holo-markings (9.71 ± 6.16 and 4.02 ± 3.20 mm, respectively). Only in half of all cases (7/14), more than 50% of the Doppler-identified points were reasonably close (<30 mm) to 3D-model ground-truth. HoloDIEP was twice as fast as Doppler ultrasound (76.9s vs. 150.4 s per abdomen). CONCLUSION: HoloDIEP allows for faster and more accurate intraoperative perforator mapping than Doppler ultrasound.

3.
Neuroradiology ; 65(10): 1555-1559, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37022486

RESUMO

We assess the theoretical feasibility of percutaneous posterior sacral foramen (pSF) needle puncture of the sacral dural sac (DS) by studying the three-dimensional imaging anatomy of pSFs relative to the sacral canal (SC). On CT images of 40 healthy subjects, we retrospectively studied sacral alae passageways from SC to pSFs in all three planes to determine if an imaginary spinal needle could theoretically traverse S1 or S2 pSFs in a straight path toward DS. If not straight, we measured multiplane angulations and morphometrics of this route. We found no straight connections between S1 or S2 pSFs and SC. Instead, there were bilateral spatially complex dorsoventral M-shaped "foraminal conduits" (FCs; common, ventral, and dorsal) from SC to anterior SFs and pSFs that would prevent percutaneous straight needle puncture of the DS. This detailed knowledge of the sacral FCs will be useful for accurate imaging interpretation and interventional procedures on the sacrum.


Assuntos
Região Sacrococcígea , Sacro , Humanos , Sacro/diagnóstico por imagem , Sacro/cirurgia , Estudos Retrospectivos , Estudos de Viabilidade , Tomografia Computadorizada por Raios X/métodos
4.
Clin Anat ; 36(4): 669-674, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36795325

RESUMO

The caudolenticular (or transcapsular) gray bridges (CLGBs) connect the caudate nucleus (CN) and putamen across the internal capsule. The CLGBs function as the main efferent terminus from premotor and supplementary motor area cortex to the basal ganglia (BG). We conjectured if inherent variations in numbers and sizes of CLGBs could contribute to abnormal cortical-subcortical connectivity in Parkinson's disease (PD), a neurodegenerative disorder featuring a hindrance of BG processing. However, there are no literature accounts of normative anatomy and morphometry of CLGBs. We therefore retrospectively analyzed axial and coronal 3T fast spoiled gradient-echo magnetic resonance images (MRIs) of 34 healthy individuals for bilateral CLGBs symmetry, their numbers, dimensions of thickest and longest bridge, and axial surface areas of CN head and putamen. We calculated Evans' index (EI) to account for any brain atrophy. We statistically tested associations between sex or age and measured dependent variables, and linear correlations between all measured variables (significance at p < 0.05). Study subjects were F:M = 23:11 with mean age 49.9 years. All EI's were normal (<0.3). All but three CLGBs were bilaterally symmetrical with a mean 7.4 CLGBs per side. Mean CLGBs thickness and lengths were 1.0 and 4.6 mm, respectively; CN head and putamen areas were 205 and 382.0 mm2 , respectively. Females had thicker CLGBs (p = 0.02) but we found no significant interactions between sex or age and measured dependent variables, and no correlations between CN head or putamen areas and CLGBs dimensions. These normative MRI dimensions of the CLGBs will help guide future studies on the possible role of CLGBs morphometry in PD predisposition.


Assuntos
Encéfalo , Doença de Parkinson , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Encéfalo/diagnóstico por imagem , Doença de Parkinson/patologia , Gânglios da Base/diagnóstico por imagem , Gânglios da Base/patologia , Imageamento por Ressonância Magnética/métodos
5.
Radiology ; 303(3): 501, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34935512

RESUMO

Online supplemental material is available for this article.


Assuntos
COVID-19 , Pneumonia , COVID-19/diagnóstico por imagem , Humanos , SARS-CoV-2 , Tórax , Tomografia Computadorizada por Raios X
7.
Comput Biol Med ; 183: 109267, 2024 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-39405728

RESUMO

BACKGROUND AND OBJECTIVE: Volume-renderings of computed tomography or magnetic resonance angiograms (MRAs) are routinely used by surgeons in the preoperative assessment of vascular anatomy in kidney donors. Stereoscopic headsets (OST-HMD) like Microsoft HoloLens allow intuitive interaction with three-dimensional content for more intuitive comprehension, but do not allow real-time ray-casting volume-rendering of medical volume datasets on-device due to computational limitations. METHODS: We introduce NEsted Semi-Transparent Isosurface Simulated Volume-Rendering (NESTIS-VR), as an on-device alternative to ray-casting volume-rendering and developed an application for HoloLens to render kidney donor MRAs with interactive control of fundamental rendering parameters. We compared NESTIS-VR with current standard pre-calculated 2D ray-cast volume-renderings in an observational study with 2 expert kidney transplant surgeons, measuring their confidence in pre-operatively assessing the kidney pedicle arterial anatomy in 20 potential donors. We also compared it against other 3D rendering techniques to understand which features contributed most to any improvements. RESULTS: Real-time stereoscopic three-dimensional (3D) NESTIS-VR in Augmented Reality significantly improves surgeons' confidence compared with pre-calculated conventional two-dimensional (2D) ray-casting volume-rendered images (p = 0.0415/p = 0.00003). 2D non-stereoscopic NESTIS-VR was significantly superior to pre-calculated 2D ray-casting volume-rendered images for both surgeons (p = 0.044/p = 0.0003). Single isosurface 2D rendering was significantly superior than pre-calculated 2D volume-rendered images for one surgeon. There was no significant difference between binocular 3D display over 2D views with NESTIS-VR or between constrained and unconstrained vantage points for 2D viewing. CONCLUSION: NESTIS-VR provides a new approach to rendering medical datasets in computationally limited OST-HMD headsets and significantly increases surgeons' confidence of kidney donor arterial anatomy. The principal confidence benefit arises from providing surgeons interactive control over rendering parameters compared to pre-calculated renderings at preset parameters whilst rendering on-device and keeping the OST-HMD untethered from a workstation.

8.
Plast Reconstr Surg Glob Open ; 12(6): e5933, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38919516

RESUMO

Preoperative vascular imaging has become standard practice in the planning of microsurgical breast reconstruction. Currently, translating perforator locations from radiological findings to a patient's abdomen is often not easy or intuitive. Techniques using three-dimensional printing or patient-specific guides have been introduced to superimpose anatomy onto the abdomen for reference. Augmented and mixed reality is currently actively investigated for perforator mapping by superimposing virtual models directly onto the patient. Most techniques have found only limited adoption due to complexity and price. Additionally, a critical step is aligning virtual models to patients. We propose repurposing suture packaging as an image tracking marker. Tracking markers allow quick and easy alignment of virtual models to the individual patient's anatomy. Current techniques are often complicated or expensive and limit intraoperative use of augmented reality models. Suture packs are sterile, readily available, and can be used to align abdominal models on the patients. Using an iPad, the augmented reality models automatically align in the correct position by using a suture pack as a tracking marker. Given the ubiquity of iPads, the combination of these devices with readily available suture packs will predictably lower the barrier to entry and utilization of this technology. Here, our workflow is presented along with its intraoperative utilization. Additionally, we investigated the accuracy of this technology.

9.
Plast Reconstr Surg Glob Open ; 12(7): e5940, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38957720

RESUMO

We introduce a novel technique using augmented reality (AR) on smartphones and tablets, making it possible for surgeons to review perforator anatomy in three dimensions on the go. Autologous breast reconstruction with abdominal flaps remains challenging due to the highly variable anatomy of the deep inferior epigastric artery. Computed tomography angiography has mitigated some but not all challenges. Previously, volume rendering and different headsets were used to enable better three-dimensional (3D) review for surgeons. However, surgeons have been dependent on others to provide 3D imaging data. Leveraging the ubiquity of Apple devices, our approach permits surgeons to review 3D models of deep inferior epigastric artery anatomy segmented from abdominal computed tomography angiography directly on their iPhone/iPad. Segmentation can be performed in common radiology software. The models are converted to the universal scene description zipped format, which allows immediate use on Apple devices without third-party software. They can be easily shared using secure, Health Insurance Portability and Accountability Act-compliant sharing services already provided by most hospitals. Surgeons can simply open the file on their mobile device to explore the images in 3D using "object mode" natively without additional applications or can switch to AR mode to pin the model in their real-world surroundings for intuitive exploration. We believe patient-specific 3D anatomy models are a powerful tool for intuitive understanding and communication of complex perforator anatomy and would be a valuable addition in routine clinical practice and education. Using this one-click solution on existing devices that is simple to implement, we hope to streamline the adoption of AR models by plastic surgeons.

10.
Plast Reconstr Surg ; 154(4S): 63S-67S, 2024 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-38351515

RESUMO

SUMMARY: Preoperative computed tomographic angiography is increasingly performed before perforator flap-based reconstruction. However, radiologic two-dimensional thin slices do not allow for intuitive interpretation and translation to intraoperative findings. Three-dimensional volume rendering has been used to alleviate the need for mental two-dimensional to three-dimensional abstraction. Even though volume rendering allows for a much easier understanding of anatomy, it currently has limited utility, as the skin obstructs the view of critical structures. Using free, open-source software, the authors introduce a new skin-masking technique that allows surgeons to easily create a segmentation mask of the skin that can later be used to toggle the skin on and off. In addition, the mask can be used in other rendering applications. The authors use Cinematic Anatomy for photorealistic volume rendering and interactive exploration of computed tomographic angiography with and without skin. The authors present results from using this technique to investigate perforator anatomy in deep inferior epigastric perforator flaps and demonstrate that the skin-masking workflow is performed in less than 5 minutes. In Cinematic Anatomy, the view onto the abdominal wall and especially onto perforators becomes significantly sharper and more detailed when no longer obstructed by the skin. The authors perform a virtual, partial muscle dissection to show the intramuscular and submuscular course of the perforators. The skin-masking workflow allows surgeons to improve arterial and perforator detail in volume renderings easily and quickly by removing skin and could alternatively be performed solely using open-source and free software. The workflow can be easily expanded to other perforator flaps without the need for modification.


Assuntos
Angiografia por Tomografia Computadorizada , Imageamento Tridimensional , Retalho Perfurante , Humanos , Retalho Perfurante/irrigação sanguínea , Artérias Epigástricas/anatomia & histologia , Artérias Epigástricas/diagnóstico por imagem , Mamoplastia/métodos , Parede Abdominal/irrigação sanguínea , Parede Abdominal/cirurgia , Parede Abdominal/diagnóstico por imagem , Parede Abdominal/anatomia & histologia , Software
11.
Otolaryngol Head Neck Surg ; 169(4): 1083-1085, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36934457

RESUMO

Head and neck surgeons often have difficulty in relocating sites of positive margins due to the complex 3-dimensional (3D) anatomy of the head and neck. We introduce a new technique where resection specimens are 3D scanned with a smartphone, annotated in computer-assisted design software, and immediately visualized on augmented reality (AR) glasses. The 3D virtual specimen can be accurately superimposed onto surgical sites for orientation and sizing applications. During an operative workshop, a surgeon using AR glasses projected virtual, annotated specimen models back into the resection bed onto a cadaver within approximately 10 minutes. Colored annotations can correspond with pathologic annotations and guide the orientation of the virtual 3D specimen. The model was also overlayed onto a flap harvest site to aid in reconstructive planning. We present a new technique allowing interactive, sterile inspection of tissue specimens in AR that could facilitate communication among surgeons and pathologists and assist with reconstructive surgery.


Assuntos
Realidade Aumentada , Cirurgia Assistida por Computador , Humanos , Software , Cirurgia Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador , Cabeça , Imageamento Tridimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA