Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Gastrointest Endosc ; 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38272273

RESUMO

BACKGROUND AND AIMS: Small bowel (SB) capsule endoscopy (CE) is a first line procedure for exploring the SB. Endoscopic GastroIntestinal PlacemenT (EGIPT) of SB CE is sometimes necessary. While the experience of EGIPT is large in pediatric populations, we aimed to describe the safety, efficacy and outcomes of EGIPT of SB CE in adult patients. METHODS: The international CApsule endoscopy REsearch (iCARE) group set up a retrospective multicenter study. Patients over 18 year-old who underwent EGIPT of SB CE before May 2022 were included. Data were collected from medical records and capsule recordings. The primary endpoint was the technical success rate of the EGIPT procedures. RESULTS: 630 patients were included (mean age 62.5 years old, 55.9% female) from 39,565 patients (1.6%) issued from 29 centers. EGIPT technical success was achieved in 610 procedures (96.8%). Anesthesia (moderate/deep sedation or general anesthesia) and centers with intermediate or high procedure loads were independent factors of technical success. Severe adverse events occurred in three (0.5%) patients. When technically successful, EGIPT was associated with a high SB CE completion rate (84.4%) and with a substantial diagnostic yield (61.1%). Completion rate was significantly higher when the capsule was delivered in the SB compared to when delivered in the stomach. CONCLUSION: EGIPT of SB CE is highly feasible, safe and comes with high completion rate and diagnostic yield. When indicated, it should rather be performed under anesthesia and the capsule should be delivered in the duodenum rather than in the stomach, for better SB examination outcomes.

2.
Gastrointest Endosc ; 94(3): 589-597.e1, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33848508

RESUMO

BACKGROUND AND AIMS: Little is known about small-bowel (SB) capsule endoscopy (CE) in patients with a history of gastric surgery. This study aims to evaluate the feasibility and diagnostic yield (DY) of orally ingested SB-CE in patients with surgically altered gastric anatomy. METHODS: Twenty-four European centers retrospectively identified patients who had SB-CE after total or subtotal gastrectomy. The primary outcome was the DY of SB-CE (intermediate P1 to highly P2 relevant findings). Secondary outcomes were gastric and SB transit times, completion, cleanliness, and adverse event rates. RESULTS: Studied were 248 procedures from 243 patients (mean age, 62 years) with a history of partial gastrectomy (Billroth I, 13.1%; Billroth II, 34.6%), total gastrectomy (7.4%), Whipple procedure (12.8%), sleeve gastrectomy (7.2%), or gastric bypass surgery (24.7%). Obscure GI bleeding was the most frequent indication (85.1%). SB completion rate was 84.3%. One capsule retention in the SB was noted (adverse event rate, .4%). Median SB transit time was 286 minutes (interquartile range [235; 387]). Cleanliness was rated as adequate in 92.1% of procedures. After exclusion of abnormalities found at the upper anastomotic site, the DY was 43.6%, with inflammatory/ulcerated lesions observed more frequently (23.4%) than vascular lesions (21.0%). CONCLUSIONS: SB-CE seems to be feasible and safe in selected patients with a history of major gastric surgery and comes with a high DY. The spectrum of abnormal SB findings in these patients may be different from what is known from the literature in nonoperated patients.


Assuntos
Endoscopia por Cápsula , Estudos de Viabilidade , Hemorragia Gastrointestinal/etiologia , Humanos , Intestino Delgado , Pessoa de Meia-Idade , Estudos Retrospectivos
3.
Endoscopy ; 48(4): 373-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26561918

RESUMO

BACKGROUND AND STUDY AIMS: Video capsule endoscopy (VCE) is invaluable in the diagnosis of small-bowel pathology. Capsule retention is a major concern in patients with Crohn's disease. The patency capsule was designed to evaluate small-bowel patency before VCE. However, the actual benefit of the patency capsule test in Crohn's disease remains unclear. The aim of this study was to evaluate the clinical impact of patency capsule use on the risk of video capsule retention in patients with established Crohn's disease. PATIENTS AND METHODS: This was a retrospective, multicenter study of patients with established Crohn's disease who underwent VCE for clinical need. The utilization strategy for the patency capsule was classified as selective (only in patients with obstructive symptoms, history of intestinal obstruction or surgery, or per treating physician's request) or nonselective (all patients with Crohn's disease). The main outcome was video capsule retention in the entire cohort and within each utilization strategy. RESULTS: A total of 406 patients who were referred for VCE were included in the study. VCE was performed in 132 /406 patients (32.5 %) without a prior patency capsule test. The patency capsule test was performed in 274 /406 patients (67.5 %) and was negative in 193 patients. Overall, VCE was performed in 343 patients and was retained in the small bowel in 8 (2.3 %). In this cohort, the risk of video capsule retention in the small bowel was 1.5 % without use of a prior patency capsule and 2.1 % after a negative patency test (P = 0.9). A total of 18 patients underwent VCE after a positive patency capsule test, with a retention rate of 11.1 % (P = 0.01). Patency capsule administration strategy (selective vs. nonselective) was not associated with the risk of video capsule retention. CONCLUSIONS: Capsule retention is a rare event in patients with established Crohn's disease undergoing VCE. The risk of video capsule retention was not reduced by the nonselective use of the patency capsule. Furthermore, VCE after a positive patency capsule test in patients with Crohn's disease was associated with a high risk of video capsule retention.


Assuntos
Endoscopia por Cápsula/efeitos adversos , Doença de Crohn/diagnóstico , Remoção de Dispositivo/métodos , Obstrução Intestinal/cirurgia , Intestino Delgado/patologia , Adulto , Endoscopia por Cápsula/instrumentação , Cápsulas , Estudos Transversais , Desenho de Equipamento , Falha de Equipamento , Feminino , Seguimentos , Humanos , Obstrução Intestinal/diagnóstico , Obstrução Intestinal/etiologia , Masculino , Estudos Retrospectivos , Fatores de Tempo
4.
J Pediatr Gastroenterol Nutr ; 62(1): 43-6, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26147630

RESUMO

OBJECTIVES: The clinical presentation of colonic juvenile polyps with abdominal discomfort and occult rectal bleedings make them difficult to recognize. The aim of this study was to report the clinical features of colonic juvenile polyps in children referred to colonoscopy and evaluate fecal calprotectin (FCP) as a screening biomarker for their diagnosis. METHODS: The study included a total of 266 children (range 3.1-19.0 years, median age 15.8 years) investigated with ileocolonoscopy; of whom, 239 (89%) were investigated for inflammatory bowel disease (IBD). FCPs were analyzed as a marker of colonic inflammation, and levels < 50 mg/kg was considered to be negative. RESULTS: Juvenile polyps were detected in 12 (4.5%) children; the remaining 67 (25.2%) had Crohn disease, 57 (21.4%) ulcerative colitis, 5 (1.9%) unclassified IBD, 4 (1.5%) allergic colitis, bleeding source was localized in 6 (2.3%), and 115 (43.2%) had unspecific or normal findings. FCP was available in 203 (76.3%) children before colonoscopy; levels of FCP were higher in children with juvenile polyps (range 28-2287 mg/kg, median 844 mg/kg) compared with those with normal colonoscopies (range < 20-2443 mg/kg, median 130 mg/kg, P < 0.0001), but not compared with those with active IBD (range < 20-7780 mg/kg, median 962 mg/kg, P = 0.6299). FCPs were available in 9 of 12 children after polypectomy, of whom all had their FCP levels significantly reduced (range 0-281 mg/kg, median 49 mg/kg, P <  .0001). CONCLUSIONS: Colonic juvenile polyps are frequently found in pediatric patients presenting with hematochezia and elevated FCP levels. Colonic juvenile polyps are difficult to differentiate from pediatric IBD without a colonoscopy.


Assuntos
Pólipos do Colo/patologia , Fezes/química , Complexo Antígeno L1 Leucocitário/análise , Adolescente , Biomarcadores/análise , Criança , Pré-Escolar , Colite/diagnóstico , Colite Ulcerativa/diagnóstico , Pólipos do Colo/complicações , Pólipos do Colo/cirurgia , Colonoscopia/métodos , Doença de Crohn/diagnóstico , Diagnóstico Diferencial , Feminino , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Humanos , Masculino , Valor Preditivo dos Testes , Adulto Jovem
5.
Dig Dis Sci ; 61(7): 2033-40, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27007135

RESUMO

BACKGROUND: Accurate inflammation reporting in capsule endoscopy (CE) is important for diagnosis and monitoring of treatment of inflammatory bowel disease (IBD). Fecal calprotectin (FC) is a highly specific biomarker of gut inflammation. Lewis score (LS) was developed to standardize quantification of inflammation in small-bowel (SB) CE images. GOALS: Multicenter retrospective study aiming to investigate correlation between LS and FC in a large group of patients undergoing CE for suspected or known small-bowel IBD, and to develop a model for prediction of CE results (LS) based on FC levels. STUDY: Five academic centers and a district general hospital offering CE in UK, Finland, Sweden, Canada, and Israel. In total, 333 patients were recruited. They had small-bowel CE and FC done within 3 months. RESULTS: Overall, correlation between FC and LS was weak (r s: 0.232, P < 0.001). When two clinically significant FC thresholds (100 and 250 µg/g) were examined, the r s between FC and LS was 0.247 (weak) and 0.337 (moderate), respectively (P = 0.307). For clinically significant (LS ≥ 135) or negative (LS < 135) for SB inflammation, ROC curves gave an optimum cutoff point of FC 76 µg/g with sensitivity 0.59 and specificity 0.41. LIMITATIONS: Retrospective design. CONCLUSIONS: LS appears to show low correlation with FC as well as other serology markers of inflammation. FC does not appear to be a reliable biomarker for significant small-bowel inflammation. Nevertheless, FC level ≥ 76 µg/g may be associated with appreciable visual inflammation on small-bowel CE in patients with negative prior diagnostic workup.


Assuntos
Endoscopia por Cápsula , Fezes/química , Inflamação/patologia , Intestino Delgado/patologia , Complexo Antígeno L1 Leucocitário/química , Proteína C-Reativa/química , Fezes/citologia , Humanos , Monócitos , Estudos Retrospectivos
6.
Endoscopy ; 47(2): 172-4, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25314326

RESUMO

In this prospective study, 11 consecutive patients with neoplastic colorectal lesions (median size 20 mm, range 15 - 25 mm) underwent endoscopic polyp removal by underwater endoscopic mucosal resection (EMR). Six lesions were removed en bloc and five lesions were removed by piecemeal resection. Pathological examination revealed seven R0 resections, and in four cases the pathology could not be determined. Two cases of procedure-related bleeding occurred but these were easily managed using hemostatic forceps and clip application. No perforations or delayed bleedings were observed. Underwater EMR is a relatively simple, safe, and useful method for the removal of large colorectal lesions.


Assuntos
Adenoma/cirurgia , Pólipos do Colo/cirurgia , Neoplasias Colorretais/cirurgia , Endoscopia Gastrointestinal/métodos , Imersão , Adenoma/patologia , Idoso , Idoso de 80 Anos ou mais , Pólipos do Colo/patologia , Neoplasias Colorretais/patologia , Endoscopia Gastrointestinal/efeitos adversos , Feminino , Humanos , Mucosa Intestinal/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Carga Tumoral , Água
7.
Lancet Digit Health ; 6(5): e345-e353, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38670743

RESUMO

BACKGROUND: Capsule endoscopy reading is time consuming, and readers are required to maintain attention so as not to miss significant findings. Deep convolutional neural networks can recognise relevant findings, possibly exceeding human performances and reducing the reading time of capsule endoscopy. Our primary aim was to assess the non-inferiority of artificial intelligence (AI)-assisted reading versus standard reading for potentially small bowel bleeding lesions (high P2, moderate P1; Saurin classification) at per-patient analysis. The mean reading time in both reading modalities was evaluated among the secondary endpoints. METHODS: Patients aged 18 years or older with suspected small bowel bleeding (with anaemia with or without melena or haematochezia, and negative bidirectional endoscopy) were prospectively enrolled at 14 European centres. Patients underwent small bowel capsule endoscopy with the Navicam SB system (Ankon, China), which is provided with a deep neural network-based AI system (ProScan) for automatic detection of lesions. Initial reading was performed in standard reading mode. Second blinded reading was performed with AI assistance (the AI operated a first-automated reading, and only AI-selected images were assessed by human readers). The primary endpoint was to assess the non-inferiority of AI-assisted reading versus standard reading in the detection (diagnostic yield) of potentially small bowel bleeding P1 and P2 lesions in a per-patient analysis. This study is registered with ClinicalTrials.gov, NCT04821349. FINDINGS: From Feb 17, 2021 to Dec 29, 2021, 137 patients were prospectively enrolled. 133 patients were included in the final analysis (73 [55%] female, mean age 66·5 years [SD 14·4]; 112 [84%] completed capsule endoscopy). At per-patient analysis, the diagnostic yield of P1 and P2 lesions in AI-assisted reading (98 [73·7%] of 133 lesions) was non-inferior (p<0·0001) and superior (p=0·0213) to standard reading (82 [62·4%] of 133; 95% CI 3·6-19·0). Mean small bowel reading time was 33·7 min (SD 22·9) in standard reading and 3·8 min (3·3) in AI-assisted reading (p<0·0001). INTERPRETATION: AI-assisted reading might provide more accurate and faster detection of clinically relevant small bowel bleeding lesions than standard reading. FUNDING: ANKON Technologies, China and AnX Robotica, USA provided the NaviCam SB system.


Assuntos
Inteligência Artificial , Endoscopia por Cápsula , Hemorragia Gastrointestinal , Intestino Delgado , Humanos , Endoscopia por Cápsula/métodos , Hemorragia Gastrointestinal/diagnóstico , Estudos Prospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Idoso , Adulto , Idoso de 80 Anos ou mais , Redes Neurais de Computação
8.
Diagnostics (Basel) ; 13(1)2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36611310

RESUMO

Colon capsule endoscopy (CCE) is a promising modality for colonic investigations, but completion rates (CR) and adequate cleansing rates (ACR) must be improved to meet established standards for optical colonoscopy. Improvements should be made with patient acceptability in mind. We aimed to compare a very low-volume polyethylene glycol (PEG) laxative to a conventional high-volume laxative. We carried out a single-center retrospective comparative cohort study including patients referred for CCE. One hundred and sixty-six patients were included in the final analysis, with eighty-three patients in each group. We found a CR and ACR of 77% and 67% in the high-volume group and 72% and 75% in the very low-volume group, respectively. In the high-volume group, 54% had complete transit and adequate cleansing, whereas this was the case for 63% in the very low-volume group. No statistically significant difference in CR, ACR, or a combination of the two was found. A very low-volume bowel preparation regimen was non-inferior to a high-volume regimen before CCE in terms of CR and ACR.

9.
Diagnostics (Basel) ; 12(7)2022 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-35885608

RESUMO

(1) Background: Villous atrophy is an indication for small bowel capsule endoscopy (SBCE). However, SBCE findings are not described uniformly and atrophic features are sometimes not recognized; (2) Methods: The Delphi technique was employed to reach agreement among a panel of SBCE experts. The nomenclature and definitions of SBCE lesions suggesting the presence of atrophy were decided in a core group of 10 experts. Four images of each lesion were chosen from a large SBCE database and agreement on the correspondence between the picture and the definition was evaluated using the Delphi method in a broadened group of 36 experts. All images corresponded to histologically proven mucosal atrophy; (3) Results: Four types of atrophic lesions were identified: mosaicism, scalloping, folds reduction, and granular mucosa. The core group succeeded in reaching agreement on the nomenclature and the descriptions of these items. Consensus in matching the agreed definitions for the proposed set of images was met for mosaicism (88.9% in the first round), scalloping (97.2% in the first round), and folds reduction (94.4% in the first round), but granular mucosa failed to achieve consensus (75.0% in the third round); (4) Conclusions: Consensus among SBCE experts on atrophic lesions was met for the first time. Mosaicism, scalloping, and folds reduction are the most reliable signs, while the description of granular mucosa remains uncertain.

10.
Gastrointest Endosc ; 74(3): 581-589.e1, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21601200

RESUMO

BACKGROUND: Colon capsule endoscopy (CCE) represents a noninvasive technology that allows visualization of the colon without requiring sedation and air insufflation. A second-generation colon capsule endoscopy system (PillCam Colon 2) (CCE-2) was developed to increase sensitivity for colorectal polyp detection compared with the first-generation system. OBJECTIVE: To assess the feasibility, accuracy, and safety of CCE-2 in a head-to-head comparison with colonoscopy. DESIGN AND SETTING: Prospective, multicenter trial including 8 European sites. PATIENTS: This study involved 117 patients (mean age 60 years). Data from 109 patients were analyzed. INTERVENTION: CCE-2 was prospectively compared with conventional colonoscopy as the criterion standard for the detection of colorectal polyps that are ≥6 mm or masses in a cohort of patients at average or increased risk of colorectal neoplasia. Colonoscopy was independently performed within 10 hours after capsule ingestion or on the next day. MAIN OUTCOME MEASUREMENTS: CCE-2 sensitivity and specificity for detecting patients with polyps ≥6 mm and ≥10 mm were assessed. Capsule-positive but colonoscopy-negative cases were counted as false positive. Capsule excretion rate, level of bowel preparation, and rate of adverse events also were assessed. RESULTS: Per-patient CCE-2 sensitivity for polyps ≥6 mm and ≥10 mm was 84% and 88%, with specificities of 64% and 95%, respectively. All 3 invasive carcinomas were detected by CCE-2. The capsule excretion rate was 88% within 10 hours. Overall colon cleanliness for CCE-2 was adequate in 81% of patients. LIMITATIONS: Not unblinding the CCE-2 results at colonoscopy; heterogenous patient population; nonconsecutive patients. CONCLUSION: In this European, multicenter study, CCE-2 appeared to have a high sensitivity for the detection of clinically relevant polypoid lesions, and it might be considered an adequate tool for colorectal imaging.


Assuntos
Adenoma/diagnóstico , Endoscopia por Cápsula , Pólipos do Colo/diagnóstico , Colonoscopia , Neoplasias Colorretais/diagnóstico , Idoso , Endoscopia por Cápsula/efeitos adversos , Pólipos do Colo/patologia , Colonoscopia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
12.
Endosc Int Open ; 9(1): E22-E30, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33403232

RESUMO

Background and study aims The aim of this study was to elucidate the differences in image-enhanced endoscopy (IEE) findings between Helicobacter - pylori -associated and autoimmune gastritis. Patients and methods Seven H. pylori -naïve, 21 patients with H. pylori -associated gastritis and seven with autoimmune gastritis were enrolled. Mucosal atrophy in the corpus was evaluated using autofluorescence imaging and classified into small, medium and large. In a 2 × 2-cm area of the lesser curvature of the lower corpus, micromucosal pattern was evaluated by magnifying narrow band imaging and proportion of foveola (FV)- and groove (GR)-type mucosa was classified into FV > 80 %, FV 50 % to 80 %, GR 50 % to 80 %, and GR > 80 %, then a biopsy specimen was taken. Results Fifteen of 21 (71 %) H. pylori -associated gastritis patients exhibited medium-to-large atrophic mucosa at the corpus lesser curvature. All autoimmune gastritis patients had large atrophic mucosa throughout the corpus ( P  < 0.001). All H. pylori -naïve patients had the FV > 80 % micromucosal pattern. Nineteen of 21 (90 %) H. pylori -associated gastritis patients had varying proportions of GR- and FV-type mucosae and five of seven (71 %) autoimmune gastritis patients showed FV > 80 % mucosa ( P  < 0.001). Compared with patients who were H. pylori -naïve, patients with H. pylori -associated and autoimmune gastritis exhibited a higher grade of atrophy ( P  < 0.001), but only patients with H. pylori -associated gastritis showed a higher grade of intestinal metaplasia ( P  = 0.022). Large mucosal atrophy with FV > 80 % micromucosal pattern had sensitivity of 71 % (95 % CI: 29 %-96 %) and specificity of 100 % (95 % CI: 88 % to 100 %) for diagnosis of autoimmune gastritis. Conclusions IEE findings of the gastric corpus differed between H. pylori -associated and autoimmune gastritis, suggesting different pathogenesis of the two diseases.

13.
J Clin Med ; 9(9)2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32942749

RESUMO

BACKGROUND: Conventional colonoscopy (CC) allows access for colonic investigation and intervention; in the small group in whom CC is unsuccessful alternative imaging is often sufficient. There remains a subset, however, requiring full colonic visualisation or intervention. Balloon-assisted colonoscopy (BAC) gives a further option when access is difficult. Aims: This study aims to present the experience with BAC of two European tertiary referral centres. Methods: Procedures were carried out under local protocol over 15-years (2006-2020). Markers of procedural quality such as caecal intubation, complications and comfort were retrospectively compiled and analysed. Published evidence was summarised for comparison. Results: 122 procedures were undertaken, with polyps the most frequent indication and 90.2% having at least one previously incomplete CC. Features associated with difficult colonoscopy were common, including intraabdominal surgery (32.0%). 92.6% reached the caecum; completion was higher (96.3%) in those failing CC due to discomfort and lower in those failing due to anatomical difficulties (90.7%) or previous surgery (84.6%). Mean time to the caecum was 20.9 minutes and mean midazolam and fentanyl doses were 2.6 mg and 49.9 µg with low discomfort scores. Conclusion(s): Balloon-assisted colonoscopy is successful in >90% of patients, is well-tolerated, and is safe.

14.
United European Gastroenterol J ; 8(1): 99-107, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32213061

RESUMO

BACKGROUND: In the medical literature, the nomenclature and descriptions (ND) of small bowel (SB) ulcerative and inflammatory (U-I) lesions in capsule endoscopy (CE) are scarce and inconsistent. Inter-observer variability in interpreting these findings remains a major limitation in the assessment of the severity of mucosal lesions, which can impact negatively on clinical care, training and research on SB-CE. OBJECTIVE: Focusing on SB-CE in Crohn's disease (CD), our aim is to establish a consensus on the ND of U-I lesions. METHODS: An international panel of experienced SB-CE readers was formed during the 2016 United European Gastroenterology Week meeting. A core group of five CE and inflammatory bowel disease (IBD) experts established an Internet-based, three-round Delphi consensus but did not participate in the voting process. The core group built illustrated questionnaires, including SB-CE still frames of U-I lesions from patients with documented CD. Twenty-seven other experts were asked to rate and comment on the different proposals for the ND of the most frequent SB U-I lesions. For each round, we used a 6-point rating scale (varying from 'strongly disagree' to 'strongly agree'). The consensus was reached when at least 80 % of the voting members scored the statement within the 'agree' or 'strongly agree' categories. RESULTS: A 100% participation rate was obtained for all the rounds. Consensual ND were reached for the following seven U-I lesions: aphthoid erosion, deep ulceration, superficial ulceration, stenosis, edema, hyperemia and denudation. CONCLUSION: Considering the most frequent SB U-I lesions seen in CE in CD, a consensual ND was reached by the international group of experts. These descriptions and names are useful not only for daily practice and medical education, but also for medical research.


Assuntos
Endoscopia por Cápsula/normas , Doença de Crohn/diagnóstico , Intestino Delgado/diagnóstico por imagem , Terminologia como Assunto , Consenso , Doença de Crohn/imunologia , Doença de Crohn/patologia , Técnica Delphi , Gastroenterologia/normas , Humanos , Cooperação Internacional , Intestino Delgado/imunologia , Intestino Delgado/patologia , Variações Dependentes do Observador , Semântica
16.
J Clin Med ; 8(11)2019 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-31718057

RESUMO

Data on malignancy in patients with collagenous colitis (CC) is scarce. We aimed to determine the incidence of cancers in patients with CC. In a two-stages, observational study, data on cancers in patients diagnosed with CC during 2000-2015, were collected from two cohorts. The risk was calculated according to the age-standardized rate for the first cohort and according to the standardized incidence ratio for the second cohort. The first cohort comprised 738 patients (394 from Scotland and 344 from Sweden; mean age 71 ± 11 and 66 ± 13 years, respectively). The incidence rates for lung cancer (RR 3.9, p = 0.001), bladder cancer (RR 9.2, p = 0.019), and non-melanoma skin cancer (NMSC) (RR 15, p = 0.001) were increased. As the majority of NMSC cases (15/16) came from Sweden, a second Swedish cohort, comprising 1141 patients (863 women, mean age 65 years, range 20-95 years) was collected. There were 93 cancer cases (besides NMSC). The risk for colon cancer was decreased (SIR 0.23, p= 0.0087). The risk for cutaneous squamous cell carcinoma was instead markedly increased (SIR 3.27, p = 0.001).

17.
Endosc Int Open ; 7(3): E372-E379, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30834297

RESUMO

Background and study aims Nomenclature and descriptions of small bowel (SB) vascular lesions in capsule endoscopy (CE) are scarce in the medical literature. They are mostly based on the reader's opinion and thus differ between experts, with a potential negative impact on clinical care, teaching and research regarding SBCE. Our aim was to better define a nomenclature and to give a description of the most frequent vascular lesions in SBCE. Methods A panel of 18 European expert SBCE readers was formed during the UEGW 2016 meeting. Three experts constructed an Internet-based four-round Delphi consensus, but did not participate in the voting process. They built questionnaires that included various still frames of vascular lesions obtained with a third-generation SBCE system. The 15 remaining participants were asked to rate different proposals and description of the most common SB vascular lesions. A 6-point rating scale (varying from 'strongly disagree' to 'strongly agree') was used successive rounds. The consensus was reached when at least 80 % voting members scored the statement within the 'agree' or 'strongly agree'. Results Consensual terms and descriptions were reached for angiectasia/angiodysplasia, erythematous patch, red spot/dot, and phlebectasia. A consensual description was reached for more subtle vascular lesions tentatively named "diminutive angiectasia" but no consensus was reached for this term. Conclusion An international group has reached a consensus on the nomenclature and descriptions of the most frequent and relevant SB vascular lesions in CE. These terms and descriptions are useful in daily practice, for teaching and for medical research purposes.

19.
Therap Adv Gastroenterol ; 11: 1756284818758929, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29531578

RESUMO

BACKGROUND: Video capsule endoscopy (VCE) is a noninvasive method enabling excellent visualization of the small bowel (SB) mucosa. The aim of this study was to examine the impact and safety of VCE performed in children and adolescents with suspected or established Crohn's disease (CD). METHODS: A total of 180 VCE examinations in 169 consecutive patients conducted in 2003-14 in a single center were retrospectively analyzed. The median age was 13 years (range 3-17 years) and indications for VCE were suspected (125 cases, 69%) and established (55 cases, 31%) CD. VCE was performed with a PillCam SB (Given Imaging, Yokneam, Israel) VCE system with 8-12 h of registration without bowel preparation. RESULTS: A total of 154 of 180 (86%) patients swallowed the capsule and 26 (14%) had the capsule endoscopically placed in the duodenum. Patency capsule examination was performed in 71 cases prior to VCE to exclude SB obstruction. VCE detected findings consistent with SB CD in 71 (40%) examinations and 17 (9%) procedures showed minor changes not diagnostic for CD. A total of 92 (51%) examinations displayed normal SB mucosa. The capsule did not reach the colon within the recording time in 30 (17%) procedures and were defined as incomplete examinations. A change in diagnosis or therapy was recommended in 56 (31%) patients based on VCE results. Capsule retention occurred in one patient. CONCLUSIONS: VCE is a safe method in children with suspected or established CD. VCE often leads to a definitive diagnosis and has a significant impact on the clinical management of pediatric patients with CD.

20.
Orv Hetil ; 148(32): 1491-7, 2007 Aug 12.
Artigo em Húngaro | MEDLINE | ID: mdl-17675276

RESUMO

BACKGROUND AND AIMS: Limited number of data are available on small bowel changes due to portal hypertension. The present retrospective, comparative study was aimed to analyse the diagnostic yield and to describe the findings with capsule endoscopy of cirrhotic patients with obscure gastrointestinal bleeding. PATIENTS AND METHODS: Capsule endoscopy findings of 11 cirrhotic patients with portal hypertension and 22 non-cirrhotic patients with gastrointestinal bleeding who had undergone non-diagnostic upper endoscopy and colonoscopy were compared. Capsule video recordings were evaluated by two investigators at both workplaces. Patients after capsule endoscopy were followed-up until a mean of 19 (1-42) months. RESULTS: In total 7 men and 5 women were examined at two medical centres in 48 months with a mean age of 66.2 (+/-7.6) years. The average period between the first clinical symptoms and capsule endoscopy was 15.7 (+/-14.9) months. During this period patients were hospitalized in an average of 2.8 (+/-1.3) times and 7.9 examinations were performed per patients prior to capsule endoscopy. A small bowel bleeding source was diagnosed in all 11 patients. Two definitive bleeding sources were observed in 7 patients (63%). Lesions connected to portal hypertension were found in all patients (8 angiodysplasias, 2 portal hypertensive enteropathies and 1 bowel varix). During the follow-up period rebleeding occurred in 27.3% of cirrhotic patients compared with 18.2% rebleeding rate in the control group. CONCLUSION: Capsule endoscopy is a useful method in patients with portal hypertension and obscure gastrointestinal bleeding after negative upper endoscopy and colonoscopy. Multiple angiodysplasias are often diagnosed in the background of small bowel bleedings, and several bleeding sources frequently occur in these patients.


Assuntos
Angiodisplasia/diagnóstico , Endoscopia por Cápsula , Hemorragia Gastrointestinal/complicações , Hipertensão Portal/complicações , Intestino Delgado/patologia , Idoso , Angiodisplasia/patologia , Feminino , Seguimentos , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/patologia , Humanos , Hipertensão Portal/etiologia , Hipertensão Portal/patologia , Cirrose Hepática/complicações , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA