Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Rev Cardiovasc Med ; 25(5): 176, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-39076481

RESUMO

Heart failure (HF) is a common disease associated with high morbidity and mortality rates despite advanced pharmacological therapies. Heart transplantation remains the gold standard therapy for end-stage heart failure; however, its application is curtailed by the persistent shortage of donor organs. Over the past two decades, mechanical circulatory support, notably Left Ventricular Assist Devices (LVADs), have been established as an option for patients waiting for a donor organ. This comprehensive review focuses on elucidating the benefits and barriers associated with this application. We provide an overview of landmark clinical trials that have evaluated the use of LVADs as a bridge to transplantation therapy, with a particular focus on post-transplant outcomes. We discuss the benefits of stabilizing patients with these systems, weighing associated complications and limitations. Further technical advancements and research on optimal implantation timing are critical to ultimately improve outcomes and securing quality of life. In a world where the availability of donor organs remains constrained, LVADs are an increasingly important piece of patient care, bridging the critical gap to transplantation in advanced heart failure management.

2.
Artif Organs ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38803239

RESUMO

BACKGROUND: Stroke after durable left ventricular assist device (d-LVAD) implantation portends high mortality. The incidence of ischemic and hemorrhagic stroke and the impact on stroke outcomes of temporary mechanical circulatory support (tMCS) management among patients requiring bridge to d-LVAD with micro-axial flow-pump (mAFP, Abiomed) is unsettled. METHODS: Consecutive patients, who underwent d-LVAD implantation after being bridged with mAFP at 19 institutions, were retrospectively included. The incidence of early ischemic and hemorrhagic stroke after d-LVAD implantation (<60 days) and association of pre-d-LVAD characteristics and peri-procedural management with a specific focus on tMCS strategies were studied. RESULTS: Among 341 patients, who underwent d-LVAD implantation after mAFP implantation (male gender 83.6%, age 58 [48-65] years, mAFP 5.0/5.5 72.4%), the early ischemic stroke incidence was 10.8% and early hemorrhagic stroke 2.9%. The tMCS characteristics (type of mAFP device and access, support duration, upgrade from intra-aortic balloon pump, ECMELLA, ECMELLA at d-LVAD implantation, hemolysis, and bleeding) were not associated with ischemic stroke after d-LVAD implant. Conversely, the device model (mAFP 2.5/CP vs. mAFP 5.0/5.5: HR 5.6, 95%CI 1.4-22.7, p = 0.015), hemolysis on mAFP support (HR 10.5, 95% CI 1.3-85.3, p = 0.028) and ECMELLA at d-LVAD implantation (HR 5.0, 95% CI 1.4-18.7, p = 0.016) were associated with increased risk of hemorrhagic stroke after d-LVAD implantation. Both early ischemic (HR 2.7, 95% CI 1.9-4.5, p < 0.001) and hemorrhagic (HR 3.43, 95% CI 1.49-7.88, p = 0.004) stroke were associated with increased 1-year mortality. CONCLUSIONS: Among patients undergoing d-LVAD implantation following mAFP support, tMCS characteristics do not impact ischemic stroke occurrence, while several factors are associated with hemorrhagic stroke suggesting a proactive treatment target to reduce this complication.

3.
Surg Technol Int ; 432023 12 29.
Artigo em Inglês | MEDLINE | ID: mdl-38237112

RESUMO

Recently, temporary mechanical circulatory support (tMCS) has been increasingly used for cardiogenic shock therapy. Originally designed as a bail-out option for patients who could not be weaned from cardiopulmonary bypass, the indications for tMCS have been expended and now enable us to support a wide range of patients with various cardiac pathologies. Modern tMCS devices include microaxial flow pumps (mAFP) which are small, versatile systems that can provide both acute cardiac support and cardiac protection for high-risk interventions. In this paper, we review different surgical implantation techniques with modern mAFP as well as specific aspects of preoperative indications and patient evaluation.

4.
Artif Organs ; 46(5): 908-921, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34904259

RESUMO

BACKGROUND: Cardiopulmonary bypass (CPB) during left ventricular assist device (LVAD) implantation provides circulatory support and allows for safe inspection of the left ventricle (LV), whereas circulatory support by veno-arterial extracorporeal life support (va-ECLS) or off-pump implantation may reduce postoperative bleeding and inflammatory response. METHODS: Retrospective analysis of 616 consecutive adult patients who received an LVAD via median sternotomy between January 1, 2015 and December 31, 2019. All patients undergoing concomitant intracardiac procedures other than closure of persistent foramen ovale or atrial septal defect and redo surgeries were excluded from the analysis. The remaining patients (n = 222) were divided into two groups and 1:1 propensity score-matched regarding preoperative parameters: patients who underwent LVAD implantation with LV inspection employing CPB (CPB group, n = 62) and without LV inspection on va-ECLS or off-pump (non-CPB group, n = 62). RESULTS: The groups were well balanced with regard to preoperative baseline characteristics (standard difference <0.1). Patients in the CPB group required more blood transfusions (median 2 vs. 0 units, p = 0.031) during surgery and in the first 24 h afterwards. The median intensive care unit stay was longer in the CPB group (18 vs. 11 days, p = 0.021). The CPB group showed an absence of perioperative stroke and a smaller number of events per patient-year for postoperative ischemic stroke (0.02 vs. 0.12, p = 0.003). 30-day survival (87% vs. 87.1%) and 1-year survival (80.3% vs. 74%) were similar in both groups (p = 0.78). CONCLUSION: Visual LV inspection on CPB may reduce the risk of postoperative ischemic stroke. Despite the negative effects of employing CPB in lieu of other intraoperative strategies, survival was similar in both groups.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Adulto , Ponte Cardiopulmonar , Oxigenação por Membrana Extracorpórea/métodos , Ventrículos do Coração , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
5.
Surg Technol Int ; 412022 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-35623038

RESUMO

Over the past few decades, the field of minimally invasive cardiac surgery has significantly broadened. Novel surgical and endovascular techniques have been developed for the treatment of aortic valve pathologies. Surgical aortic valve replacement (SAVR) through a right antero-lateral (mini-)thoracotomy (RALT) has gained approval due to its limited postoperative trauma, faster rehabilitation and sufficient pain control. Nevertheless, SAVR RALT has not been adopted by a significant proportion of cardiac surgeons, due, in part, to its technical complexity and steep learning curve. In this review, we discuss the data for minimally invasive aortic valve surgery and describe our operative technique for SAVR RALT.

6.
J Card Surg ; 36(10): 3905-3909, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34250624

RESUMO

BACKGROUND: Systemic infections and chronic graft rejection represent common causes of mortality and morbidity in heart transplant patients. In severe cases, cardiogenic shock (CS) may occur and require hemodynamic stabilization with temporary mechanical circulatory support (tempMCS). Under these devastating circumstances, treatment of sequelae of left ventricular dysfunction, such as secondary mitral regurgitation (MR) is challenging, especially when surgical repair is deemed futile. In nontransplant patients, interventional mitral valve repair strategies such as the MitraClip system (Abbott Cardiovascular) have been used to successfully treat secondary MR and allow for weaning from tempMCS. CASE SUMMARY: We report about the first patient in whom profound CS after heart transplantation was stabilized with tempMCS followed by interventional elimination of secondary MR.


Assuntos
Transplante de Coração , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Catéteres , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
7.
J Card Surg ; 36(11): 4141-4152, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34460968

RESUMO

BACKGROUND AND METHODS: Microaxial left ventricular assist devices are used increasingly for treating cardiogenic shock. We compared the short-term outcome of patients supported with different microaxial devices for cardiogenic shock. A retrospective propensity score-adjusted analysis was performed in cardiogenic shock patients treated with either the Impella CP (n = 64) or the Impella 5.0/5.5 (n = 62) at two tertiary cardiac care centers between 1/14 and 12/19. RESULTS: Patients in the Impella CP group were significantly older (69.6 ± 10.7 vs. 58.7 ± 11.9 years, p = .001), more likely in INTERMACS profile 1 (76.6% vs. 50%, p = .003) and post-C-reactive protein (CPR) (36% vs. 13%, p = .006). The median support time was 2.0 days [0.0, 5.3] in the CP group vs. 8.5 days [4.3, 15.8] in the 5.0/5.5 group (p < .001). The unadjusted 30-day survival was significantly higher in the Impella 5.0/5.5 group (58% vs. 36%, p = .021, odds ratio [OR] for 30-day survival on Impella 5.0/5.5 was 3.68 [95% confidence interval [CI]: [1.46-9.90]], p = .0072). After adjustment, the 30-day survival was similar for both devices (OR: 1.23, 95% CI: [0.34-4.18], p = .744). Lactate levels above 8 mmol/L and preoperative CPR were associated with a significant mortality increase in both cohorts (OR: 10.7, 95% CI: [3.45-47.34], p < .001; OR: 13.2, 95% CI: [4.28-57.89], p < .001, respectively). CONCLUSION: Both Impella devices offer a similar effect with regard to survival in cardiogenic shock patients. Preoperative CPR or lactate levels exceeding 8 mmol/L immediately before implantation have a poor prognosis on Impella CP and Impella 5.0/5.5.


Assuntos
Coração Auxiliar , Choque Cardiogênico , Humanos , Pontuação de Propensão , Estudos Retrospectivos , Choque Cardiogênico/terapia , Resultado do Tratamento
8.
Surg Technol Int ; 37: 263-269, 2021 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-33463696

RESUMO

Implantable left ventricular assist devices (durable LVADs) have dramatically improved mortality and morbidity in patients with advanced heart failure. Originally designed as a bridge or candidacy to heart transplantation, the indications extend toward permanent support and palliation. Modern durable continuous flow LVADs are small, commercially available, and allow for different surgical approaches to a wide range of patients with various cardiac pathologies. We will review different surgical implantation techniques of modern continuous flow LVADs, as well as specific aspects of preoperative patient evaluation and planning.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração , Humanos
9.
J Card Surg ; 35(11): 3195-3198, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32741036

RESUMO

INTRODUCTION: Outflow graft (OG) obstruction is a dangerous complication that may occur for various reasons after the implantation of the left ventricular assist device (LVAD). CASE REPORT: In this study, we describe the case of a 67-year-old patient on LVAD support who developed a late pseudoaneurysm of the OG anastomosis (to the descending aorta) causing OG stenosis at the level of the anastomosis. The patient was treated with a customized fenestrated endovascular stent graft placed into the descending aorta and stent implantation into the OG.


Assuntos
Anastomose Cirúrgica/efeitos adversos , Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Aorta Torácica/cirurgia , Procedimentos Endovasculares/métodos , Coração Auxiliar/efeitos adversos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Implantação de Prótese/efeitos adversos , Stents , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Idoso , Humanos , Masculino , Resultado do Tratamento
10.
J Card Surg ; 35(10): 2853-2856, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32683721

RESUMO

BACKGROUND: Outflow graft (OG) obstruction is a dangerous complication that may occur for various reasons after left ventricular assist device (LVAD) implantation. CASE SUMMARY: We describe the case of a 51-year-old patient on LVAD support who developed significant OG kinking and external OG obstruction due to a fibrin mass causing severe stenosis. Both the OG kinking and external obstruction were eliminated via a left lateral thoracotomy.


Assuntos
Fibrina , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/cirurgia , Coração Auxiliar/efeitos adversos , Implantação de Prótese/efeitos adversos , Toracotomia/métodos , Trombose/etiologia , Oclusão de Enxerto Vascular/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
11.
J Cardiothorac Surg ; 19(1): 42, 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38308328

RESUMO

Temporary mechanical circulatory support is a treatment of choice for patients in severe cardiogenic shock. Combining veno-arterial extracorporeal life support (ECLS) with devices that enable left ventricular unloading emerges as a promising strategy to diminish detrimental effect of elevated left ventricular afterload and to improve survival. However, the need to establish multiple arterial access sites remains a major drawback of this approach due to a significant rate of vascular complications. We describe herein a case of a single arterial access for ECLS and intra-aortic balloon pump using axillary artery that may provide a simple, modular and flexible approach for escalation or de-escalation of mechanical circulatory support.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Humanos , Choque Cardiogênico/cirurgia , Choque Cardiogênico/etiologia , Oxigenação por Membrana Extracorpórea/métodos , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Artéria Axilar , Balão Intra-Aórtico/efeitos adversos , Coração Auxiliar/efeitos adversos
12.
Artigo em Inglês | MEDLINE | ID: mdl-38490254

RESUMO

OBJECTIVES: The combination of veno-arterial extracorporeal membrane oxygenation with a micro-axial flow pump (ECMELLA) is increasingly used for cardiogenic shock (CS) therapy. We report our experience with a novel single-artery access ECMELLA setup with either femoral (2.0) or jugular venous cannulation (2.1), respectively. METHODS: Data from 67 consecutive CS patients treated with ECMELLA 2.0 (n = 56) and 2.1 (n = 11) from December 2020 and December 2022 in a tertiary cardiac center were retrospectively analyzed. RESULTS: The mean age was 60.7 ± 11 years, 56 patients (84%) were male. CS aetiology was acute on chronic heart failure (n = 35, 52%), myocardial infarction (n = 13, 19.5%), postcardiotomy syndrome (n = 16, 24%) and myocarditis (n = 3, 4.5%). Preoperatively 31 patients (46%) were resuscitated, 53 (79%) were on a ventilator and 60 (90%) were on inotropic support. The median vasoactive inotropic score was 32, and the mean arterial lactate was 8.1 mmol/l. In 39 patients (58%), veno-arterial extracorporeal membrane oxygenation was explanted after a median ECMELLA support of 4 days. Myocardial recovery was achieved in 18 patients (27%), transition to a durable left ventricular assist device in 16 (24%). Thirty-three patients (n = 33; 49%) died on support (25 on ECMELLA and 8 on Impella after de-escalation), 9 (13%) of whom were palliated. Axillary access site bleeding occurred in 9 patients (13.5%), upper limb ischaemia requiring surgical revision in 3 (4.5%). Axillary site infection occurred in 6 cases (9%), and perioperative stroke in 10 (15%; 6 hemorrhagic, 4 thromboembolic). CONCLUSIONS: ECMELLA 2.0/2.1 is a feasible and effective therapy for severe CS. The single-artery cannulation technique is associated with a relatively low rate of access-related complications.

13.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38814808

RESUMO

OBJECTIVES: The aim of this study was to evaluate the outcomes of transposition of the omentum into the mediastinum to support the replacement of infected aortic grafts or to cover infected aortic grafts that are not amenable for surgical replacement. METHODS: All patients with thoracic aortic graft infections who underwent mediastinal transposition of the omentum at our institution between 2005 and 2023 were included in this study. Mediastinal transposition of the omentum was performed either after replacement of the infected graft ('curative concept') or solely as bailout procedure by wrapping the infected graft ('palliative concept'). The diagnosis, including computed tomography scans during follow-up, was made according to the criteria of the Management of Aortic Graft Infection Collaboration. RESULTS: The patient cohort consisted of 31 patients. Both in-hospital and 1-year mortality were 0% (n = 0) for the curative concept (n = 9) compared to 23% (n = 5) and 41% (n = 9) for the palliative concept (n = 22), respectively. There was no graft infection-associated death or recurrence of infection after 3 years in the curative group. Survival was 52% at 3 years in the palliative group, with freedom of infection in 59% of the patients (n = 13). CONCLUSIONS: Transposition of the omentum and wrapping of the infected aortic prosthetic graft is a useful bailout strategy for patients who are ineligible for replacement of an infected aortic graft. However, mortality stays high. For radical treatment of aortic graft infections, it may prove an effective supportive therapy and represents an important tool in the armamentarium of cardiac surgeons.


Assuntos
Aorta Torácica , Aorta , Prótese Vascular , Mediastino , Omento , Infecções Relacionadas à Prótese , Humanos , Omento/transplante , Omento/cirurgia , Masculino , Feminino , Infecções Relacionadas à Prótese/cirurgia , Aorta Torácica/cirurgia , Aorta Torácica/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Aorta/cirurgia , Mediastino/cirurgia , Implante de Prótese Vascular/métodos , Resultado do Tratamento , Adulto , Tomografia Computadorizada por Raios X
14.
J Heart Lung Transplant ; 42(5): 679-687, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36653272

RESUMO

BACKGROUND: Impella 5.0 and 5.5 (summarized as Impella 5+) are microaxial, catheter-based left ventricular assist devices (LVAD) that are implanted via a vascular graft sutured to the axillary artery and provide blood flow of up to 5.5 liter/min. This study aims to investigate the incidence of long-term complications following circulatory support with Impella 5+. METHODS: A single-center retrospective analysis of 203 consecutive adult patients treated between January 2017 and September 2021 with a surgically implanted Impella 5.0 or 5.5 via a vascular graft sutured to the axillary artery. RESULTS: The median Impella support duration was 8 days. Of 203 patients, 78 (38.4%) died while on temporary mechanical circulatory support. Fifty-five (27.1%) were successfully weaned from Impella 5+ and 70 (34.5%) were bridged to a durable LVAD with a median follow-up time of 232 (IQR 68.5, 597) days after Impella 5+ explantation. In 119 of these patients, the Impella was explanted and the vascular graft was shortened, ligated, and pushed under the pectoralis muscle; in 6 patients early graft infection prompted complete graft removal during explantation. In addition, 13 patients (10.9%) developed a late-onset graft infection after a median of 86 days, requiring complete (n = 10) or partial (n = 2) explantation of the retained graft. In 1 patient, the graft infection was successfully treated by conservative therapy. Our analysis identified no specific risk factors for graft infections. Of the 203 patients, 5 (2.5%) developed a brachial plexus injury resulting in neurological dysfunction. CONCLUSIONS: In 10.9% of patients, retaining the vascular graft was complicated by a late graft infection. Complete explantation of the graft prosthesis may decrease the infection rate, but may in turn increase the risk of brachial plexus injury. On the other hand, this method offers the possibility of bedside explantation.


Assuntos
Coração Auxiliar , Choque Cardiogênico , Adulto , Humanos , Choque Cardiogênico/terapia , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Complicações Pós-Operatórias/etiologia
15.
Eur J Cardiothorac Surg ; 63(2)2023 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-36637204

RESUMO

OBJECTIVES: Mitral regurgitation (MR) is frequently observed in patients undergoing left ventricular assist device implantation. We investigated the impact of preoperative MR on left ventricular assist device patients. METHODS: A retrospective propensity score-matched analysis of adult patients enrolled in the EUROMACS registry between 1 January 2011 and 30 November 2021 was performed. Patients were divided into 2 groups according to the grade of preoperative MR: none-to-mild (MR 0-II) or moderate-to-severe (MR III-IV). RESULTS: Following 1:1 propensity score matching, each group consisted of 914 patients. Incidence of postoperative temporary right ventricular support, reoperation for bleeding and dialysis was similar. MR III-IV demonstrated shorter median intensive care unit stay [14 days (6; 27.8) vs 10 days (5; 22), P = 0.004] and ventilation time [72 h (22, 320) vs 31 h (18, 150), P < 0.001]. Mortality was lower for MR III-IV patients [subdistribution hazard ratio: 0.66, 95% confidence interval (CI): 0.59-0.73, P < 0.001]. The 1-year survival was 68.1% (95% CI: 65.1-71.3%) in MR 0-II and 75% (95% CI: 72.1-78%) in MR III-IV. A lower incidence of total complications [odds ratio (OR): 0.93 (0.89-0.98), P = 0.003] and trend towards a lower risk of neurological dysfunction (subdistribution hazard ratio: 0.79; 95% CI: 0.61-1.01, P = 0.063) and sustained ventricular tachycardia [OR: 0.93 (0.54-1.03), P = 0.074] were demonstrated for MR III-IV. The risk of fatal stroke and pump thrombosis was similar. CONCLUSIONS: Moderate-to-severe MR in patients undergoing left ventricular assist device implantation is associated with better mid-term survival and lower incidence of total major adverse events and complications. The incidence of severe postoperative complications including fatal stroke and device thrombosis was similar.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Insuficiência da Valva Mitral , Adulto , Humanos , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Pontuação de Propensão , Resultado do Tratamento
16.
Life (Basel) ; 13(10)2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37895427

RESUMO

Mechanical circulatory support has proven effective in managing postcardiotomy cardiogenic shock by stabilizing patients' hemodynamics and ensuring adequate organ perfusion. Among the available device modalities, the combination of extracorporeal life support and a microaxial flow pump for left ventricular unloading has emerged as a valuable tool in the surgical armamentarium. In this publication, we provide recommendations for the application and weaning of temporary mechanical circulatory support in cardiogenic shock patients, derived from a consensus among leading cardiac centers in German-speaking countries.

17.
Artigo em Inglês | MEDLINE | ID: mdl-36315037

RESUMO

Myocardial recovery occurs in approximately 5% of left ventricular assist device recipients. In selected patients, it is possible to electively perform left ventricular assist device explantation after accurate myocardial function recovery assessment. Several surgical approaches and techniques have been reported in the literature that focus on left ventricular assist device removal and preservation of left ventricular geometry. We provide a detailed step-by-step tutorial for continuous-flow left ventricular assist device explantation facilitated by the use of a manufactured titanium apical recovery plug.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Remoção de Dispositivo/métodos , Ventrículos do Coração/cirurgia , Recuperação de Função Fisiológica , Insuficiência Cardíaca/cirurgia , Função Ventricular Esquerda
18.
Artigo em Inglês | MEDLINE | ID: mdl-36476648

RESUMO

A continuous-flow left ventricular assist device implant is a well-established therapy for patients with end-stage heart failure. Currently, the HeartMate 3 device is the only commercially available durable left ventricular assist device. Therefore, patients on HeartWare HVAD support who require a pump exchange must have a HeartMate 3 implanted.


Assuntos
Coração Auxiliar , Humanos
19.
Artigo em Inglês | MEDLINE | ID: mdl-36458810

RESUMO

Minimally invasive aortic valve replacement has become a feasible approach to treat various aortic valve pathologies with limited procedural trauma. Several minimally invasive aortic valve replacement approaches with different levels of complexity and technical requirements are currently available.


Assuntos
Valva Aórtica , Procedimentos Cirúrgicos Minimamente Invasivos , Humanos , Valva Aórtica/cirurgia
20.
Artigo em Inglês | MEDLINE | ID: mdl-36282201

RESUMO

The introduction of the transcatheter aortic valve implantation procedure has revolutionized the standards of care in patients with aortic valve pathologies and has significantly increased the quality of the medical treatment provided. The durability and constant technical improvements in the modern transcatheter aortic valve implantation procedure have broadened the indications towards younger patient groups with low-risk profiles. Therefore, transcatheter aortic valve implantation now represents an effective alternative for surgical aortic valve replacement in a large number of cases. Currently, various technical methods for the transcatheter aortic valve implantation procedure are available. The contemporary transcatheter aortic valve implantation procedure focuses on optimization of postoperative results and reduction of complications such as paravalvular leakage and permanent pacemaker implantation. Another goal of transcatheter aortic valve implantation is the achievement of a valid lifetime concept with secure coronary access and conditions for future valve-in-valve interventions.  In this case report, we demonstrate a standard transfemoral transcatheter aortic valve implantation procedure with a self-expandable supra-annular device, one of the most commonly performed methods.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA