Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Arch Gynecol Obstet ; 307(1): 187-194, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35284956

RESUMO

PURPOSE: Endometriosis is a benign, but potentially serious gynaecological condition in terms of abdominal pain and impaired fertility. Laparoscopic excision techniques are considered the therapeutic standard. HybridAPC is presented as a novel technique for the non-contact thermal ablation of peritoneal endometriosis with simultaneous protection of the underlying thermosensitive structures by creating a needle-free elevated fluid cushion which enables a safer exposure and distance, as well as potentially improved peritoneal conditioning prior to APC. METHODS: In this prospective randomized clinical trial, 39 patients with 132 superficial endometriotic lesions in total were treated with HybridAPC or sharp excision in an initial laparoscopic procedure according to randomization. In a second-look laparoscopy, adhesion formation was rated macroscopically. Histologic samples were taken from previously treated areas for evaluation of eradication rate. RESULTS: The eradication rate was not significantly different between HybridAPC treatment and sharp excision (65 vs. 81%, p = .55). Adhesions formed in 5% of HybridAPC-treated lesions and in 10% after sharp excision (p = .49). HybridAPC treatment was significantly faster than sharp excision (69 vs. 106 s, p < .05). No intra- and postoperative complications were registered. CONCLUSION: This clinical trial demonstrates the feasibility of this novel surgical technique with a promising impact on adhesion prevention. Compared to sharp excision, HybridAPC is likely to be a safe, tissue-preserving, and fast method for the treatment of peritoneal endometriosis.


Assuntos
Endometriose , Laparoscopia , Feminino , Humanos , Endometriose/cirurgia , Endometriose/patologia , Coagulação com Plasma de Argônio , Estudos Prospectivos , Peritônio/patologia , Laparoscopia/métodos , Aderências Teciduais/prevenção & controle , Aderências Teciduais/cirurgia , Aderências Teciduais/patologia
2.
Sensors (Basel) ; 22(5)2022 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-35271009

RESUMO

This paper documents the design, implementation and evaluation of the Unfolding Space Glove-an open source sensory substitution device. It transmits the relative position and distance of nearby objects as vibratory stimuli to the back of the hand and thus enables blind people to haptically explore the depth of their surrounding space, assisting with navigation tasks such as object recognition and wayfinding. The prototype requires no external hardware, is highly portable, operates in all lighting conditions, and provides continuous and immediate feedback-all while being visually unobtrusive. Both blind (n = 8) and blindfolded sighted participants (n = 6) completed structured training and obstacle courses with both the prototype and a white long cane to allow performance comparisons to be drawn between them. The subjects quickly learned how to use the glove and successfully completed all of the trials, though still being slower with it than with the cane. Qualitative interviews revealed a high level of usability and user experience. Overall, the results indicate the general processability of spatial information through sensory substitution using haptic, vibrotactile interfaces. Further research would be required to evaluate the prototype's capabilities after extensive training and to derive a fully functional navigation aid from its features.


Assuntos
Pessoas com Deficiência Visual , Dispositivos Eletrônicos Vestíveis , Cegueira , Bengala , Tecnologia Háptica , Humanos
3.
Arch Gynecol Obstet ; 297(4): 961-967, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29362925

RESUMO

BACKGROUND: This prospective, randomized, controlled, single-blinded study investigates the peritoneal adhesion formation of HybridAPC (waterjet elevation of the peritoneum with subsequent argon plasma coagulation) versus only waterjet (elevation with the same instrument, but without subsequent argon plasma coagulation) in a rat model (24 female Wistar rats). MATERIALS AND METHODS: Bilateral lesions were created on the abdominal wall with HybridAPC on one sidewall and waterjet elevation on the other sidewall of the peritoneum in a standard fashion. After 10 days, the rats were euthanized to evaluate the peritoneal trauma sites. MAIN OUTCOME MEASURE(S): Adhesion incidence, quantity, and quality were scored 10 days postoperatively and studied histopathologically. RESULT(S): Incidence of adhesion formation was 2.3% for HybridAPC; no adhesions occurred for peritoneal elevation with saline (p = 1.00). Histologic evaluation revealed no acute inflammation in both groups. An overall moderate degree of granulation tissue formation and myonecrosis was observed in the HybridAPC group, whereas no chronic inflammation and myonecrosis occurred after elevation without thermal ablation (p < 0.0001). CONCLUSION(S): This study investigates the effect of waterjet elevation of the peritoneum with and without subsequent thermal ablation on adhesion formation in a rat model for the first time. Peritoneal waterjet elevation with saline does not provide any risk of adhesion formation. Thermal coagulation with APC after waterjet elevation of the peritoneum creates advantageous peritoneal conditions due to a permanent moist tissue surface and the cooling effect of the injected solution, resulting in no significant difference in adhesion formation compared to peritoneal elevation without thermal ablation. HybridAPC can thus be regarded as a beneficial coagulation method with only minor adhesion formation due to positive tissue effects of the combined waterjet.


Assuntos
Coagulação com Plasma de Argônio/efeitos adversos , Modelos Animais de Doenças , Doenças Peritoneais/etiologia , Aderências Teciduais/induzido quimicamente , Parede Abdominal/patologia , Animais , Eletrocoagulação/efeitos adversos , Eletrocoagulação/métodos , Feminino , Humanos , Incidência , Injeções , Doenças Peritoneais/complicações , Doenças Peritoneais/patologia , Peritônio/patologia , Complicações Pós-Operatórias/patologia , Período Pós-Operatório , Estudos Prospectivos , Distribuição Aleatória , Ratos , Ratos Wistar , Aderências Teciduais/etiologia , Aderências Teciduais/patologia
4.
Gut ; 66(5): 783-793, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-26801885

RESUMO

BACKGROUND: For endoscopic resection of early GI neoplasia, endoscopic submucosal dissection (ESD) achieves higher rates of complete resection (R0) than endoscopic mucosal resection (EMR). However, ESD is technically more difficult and evidence from randomised trial is missing. OBJECTIVE: We compared the efficacy and safety of ESD and EMR in patients with neoplastic Barrett's oesophagus (BO). DESIGN: BO patients with a focal lesion of high-grade intraepithelial neoplasia (HGIN) or early adenocarcinoma (EAC) ≤3 cm were randomised to either ESD or EMR. Primary outcome was R0 resection; secondary outcomes were complete remission from neoplasia, recurrences and adverse events (AEs). RESULTS: There were no significant differences in patient and lesion characteristics between the groups randomised to ESD (n=20) or EMR (n=20). Histology of the resected specimen showed HGIN or EAC in all but six cases. Although R0 resection defined as margins free of HGIN/EAC was achieved more frequently with ESD (10/17 vs 2/17, p=0.01), there was no difference in complete remission from neoplasia at 3 months (ESD 15/16 vs EMR 16/17, p=1.0). During a mean follow-up period of 23.1±6.4 months, recurrent EAC was observed in one case in the ESD group. Elective surgery was performed in four and three cases after ESD and EMR, respectively (p=1.0). Two severe AEs were recorded for ESD and none for EMR (p=0.49). CONCLUSIONS: In terms of need for surgery, neoplasia remission and recurrence, ESD and EMR are both highly effective for endoscopic resection of early BO neoplasia. ESD achieves a higher R0 resection rate, but for most BO patients this bears little clinical relevance. ESD is, however, more time consuming and may cause severe AE. TRIAL REGISTRATION NUMBER: NCT1871636.


Assuntos
Adenocarcinoma/cirurgia , Esôfago de Barrett/cirurgia , Carcinoma in Situ/cirurgia , Ressecção Endoscópica de Mucosa/efeitos adversos , Ressecção Endoscópica de Mucosa/métodos , Neoplasias Esofágicas/cirurgia , Recidiva Local de Neoplasia , Adenocarcinoma/patologia , Idoso , Esôfago de Barrett/patologia , Carcinoma in Situ/patologia , Neoplasias Esofágicas/patologia , Esofagectomia , Feminino , Seguimentos , Humanos , Masculino , Margens de Excisão , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Neoplasia Residual , Estudos Prospectivos , Reoperação
5.
Biomed Eng Online ; 15(1): 117, 2016 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-27806716

RESUMO

BACKGROUND: Bipolar vessel sealing is an efficient electrosurgical procedure for the occlusion of blood vessels particularly during minimally invasive surgery. Reliable knowledge of the thermal spread is crucial for a safe application of bipolar vessel sealing instruments when operating close to thermo-sensitive structures, such as nerves. The evolution of the thermal spread over time and space depends on a variety of parameters, such as the biological tissue, the energy applied to the tissue, and the geometry of the vessel sealing instrument. Mathematical modeling has proven useful for the prediction of the thermal spread. It is, thus, a promising tool for the systematic analysis of the influence of geometrical changes on the thermal spread. RESULTS: We present an experimentally validated in silico study to evaluate the impact of geometry variations on the progression of chicken egg white coagulation and the final shape of coagulated egg white as an approximation of the temporal and spatial evolution of the thermal spread during bipolar vessel sealing. Egg white has similar thermal and electrical properties to human tissue, with the advantage being that the spatial and temporal evolution of the thermal spread can be visually gauged. The simulations were performed using a mathematical model based on the finite element analysis of chicken egg white. The progression of egg white coagulation was predicted for two different peak voltages and various electrode geometries. Starting with two planar electrodes, one electrode was gradually changed to adopt a wedge shape. These changes to the geometry showed a distinct influence on the progression of egg white coagulation in the simulations. The predictions were successfully validated using an experimental setup with two different electrodes representing the extreme geometries. DISCUSSION: The predicted spatial temperature distributions were experimentally validated for two geometries. Our simulation study shows that the geometry has a pronounced influence on the thermal spread and, thus, is a suitable parameter to reduce thermal damage. The in silico optimization of instrument designs is a suitable tool to accelerate the development of new vessel sealing instruments, with only a few promising designs having to be tested as prototypes.


Assuntos
Simulação por Computador , Clara de Ovo/química , Temperatura , Procedimentos Cirúrgicos Vasculares/instrumentação , Animais , Biomimética , Galinhas , Ondas de Rádio
6.
Int J Med Sci ; 13(3): 187-94, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26941579

RESUMO

PURPOSE: To investigate the eradication rate of endometriosis after surgical resection (SR) vs. thermal ablation with aerosol plasma coagulation (AePC) in a rat model. METHODS: In this prospective, randomized, controlled, single-blinded animal study endometriosis was induced on the abdominal wall of 34 female Wistar rats. After 14 days endometriosis was either removed by SR or ablated by AePC. 14 days later the rats were euthanized to evaluate the eradication rate histopathologically. Intervention times were recorded. RESULTS: Eradication rate of endometriosis after 14 days did not significantly differ between AePC and SR (p=0.22). Intervention time per endometrial lesion was 22.1 s for AePC and 51.8 s for SR (p<0.0001). CONCLUSIONS: This study compares the eradication rate of the new aerosol plasma coagulation device versus standard surgical resection of endometriosis in a rat model. Despite being a thermal method, AePC showed equality towards SR regarding eradication rate but with significantly shorter intervention time.


Assuntos
Endometriose/cirurgia , Fotocoagulação a Laser/métodos , Parede Abdominal , Animais , Modelos Animais de Doenças , Endometriose/patologia , Feminino , Estudos Prospectivos , Distribuição Aleatória , Ratos Wistar , Resultado do Tratamento
7.
Langenbecks Arch Surg ; 399(7): 863-71, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25064363

RESUMO

PURPOSE: The aim of this study is to systematically investigate under standardized experimental conditions the effects of instrument contamination and wear on the quality of bipolar vessel sealing (BVS) achieved using a reusable instrument. METHODS: The study was designed as a prospective, randomized, and controlled in vitro study and conducted in an academic research environment. Reusable bipolar coagulation forceps (BiClamp® 200 C, ERBE Elektromedizin) were used to apply sealing pressures of 300-1,100 mN/mm(2) to 239 renal arteries from commercially slaughtered female pigs (Swabian-Hall Swine). Forceps jaws were coated with porcine blood, blood and collagen, or blood, collagen, and fat to simulate instrument contamination with biological material during surgery. Clinical wear was mimicked by sandpaper abrasion. The main outcome measures were seal success (resistance to 250 mmHg intraluminal pressure for 2 min) and seal stability (burst pressure). RESULTS: Sealing pressure had a significant impact, with 800 mN/mm(2) producing the best sealing results. Seal success increased with total energy applied to the tissue, a higher maximum temperature, and longer coagulation as indicated by desiccation time. Experimental contamination had no significant impact on seal success and only a limited effect on seal stability. Similarly, abrasive wear also had no significant effect on either seal quality or seal strength. CONCLUSIONS: The impact of bipolar forceps contamination and wear on seal success and quality was negligible in our in vitro model. To achieve high-quality seals, it is essential to use adequate sealing pressures. Our findings could have direct implications for the design and clinical handling of BVS instruments.


Assuntos
Eletrocoagulação/instrumentação , Contaminação de Equipamentos , Artéria Renal/cirurgia , Animais , Reutilização de Equipamento , Feminino , Ligadura/instrumentação , Pressão , Estudos Prospectivos , Instrumentos Cirúrgicos , Suínos , Procedimentos Cirúrgicos Vasculares/instrumentação
8.
Surg Innov ; 21(4): 389-97, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24172164

RESUMO

BACKGROUND: This is a prospective, randomized, controlled, single-blinded study to investigate peritoneal adhesion formation of standard argon plasma coagulation (APC) versus aerosol plasma coagulation in a rat model. METHODS: Bilateral lesions were created on the abdominal wall of 16 female Wistar rats with standard and aerosol plasma coagulation APC energy in a standard fashion. After 10 days, the rats were killed humanely to evaluate the peritoneal trauma sites. Adhesion incidence, quantity, and quality were scored 10 days postoperatively and studied histopathologically. RESULTS: Average energy intake was 97.7 ± 3.1 J for APC and 93.8 ± 4.2 J for aerosol plasma coagulation. Incidence of adhesion formation was 74.2% for standard APC and 16.1% for aerosol plasma coagulation (P < .0001). Standard APC mainly results in dense adhesions. Histological evaluation revealed no significant difference with regard to the average depth of lesions created by APC and aerosol plasma coagulation (P = 0.21) at day 10; both groups showed an identical morphology of necrosis and granulation tissue formation. CONCLUSIONS: This study compares adhesion formation of standard APC versus aerosol plasma coagulation in a rat model. Standard APC produced significantly more adhesions. Aerosol plasma coagulation creates fewer adhesions, which are of lower grade, which seems to be achieved mainly by improved peritoneal conditioning in this animal model.


Assuntos
Coagulação com Plasma de Argônio/métodos , Modelos Animais de Doenças , Doenças Peritoneais/etiologia , Doenças Peritoneais/patologia , Aderências Teciduais/induzido quimicamente , Animais , Biópsia por Agulha , Feminino , Imuno-Histoquímica , Fotocoagulação a Laser/métodos , Distribuição Aleatória , Ratos , Ratos Wistar , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Aderências Teciduais/patologia
9.
PLoS One ; 19(2): e0291902, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38300913

RESUMO

METHODS: A group of RP patients (n = 8, aged 20-60) participated in a study consisting of two 4-week-phases, both carried out by the same patient group in randomized order: In the 'training phase', participants carried out a Virtual-Reality gaze training for 30 minutes per day; In the 'control phase', no training occurred. Before and after each phase, participants were tasked to move through a randomized real-world obstacle course. Navigation performance in the obstacle course as well as eye-tracking data during the trials were evaluated. The study is registered at the German Clinical Trials Register (DRKS) with the ID DRKS00032628. RESULTS: On average, the time required to move through the obstacle course decreased by 17.0% after the training phase, the number of collisions decreased by 50.0%. Both effects are significantly higher than those found in the control phase (p < 0.001 for required time, p = 0.0165 for number of collisions), with the required time decreasing by 5.9% and number of collisions decreasing by 10.4% after the control phase. The average visual area observed by participants increases by 4.41% after training, however the effect is not found to be significantly higher than in the control phase (p = 0.394). CONCLUSION: The performance increase over the training phase significantly surpasses the natural learning effect found in the control phase, suggesting that Virtual-Reality based gaze training can have a positive effect on real-world navigation tasks for patients with RP. The training is available as work-in-progress open-source software.


Assuntos
Retinose Pigmentar , Realidade Virtual , Humanos , Aprendizagem , Software , Estudos Cross-Over
10.
Diagnostics (Basel) ; 14(3)2024 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-38337854

RESUMO

Breast conserving resection with free margins is the gold standard treatment for early breast cancer recommended by guidelines worldwide. Therefore, reliable discrimination between normal and malignant tissue at the resection margins is essential. In this study, normal and abnormal tissue samples from breast cancer patients were characterized ex vivo by optical emission spectroscopy (OES) based on ionized atoms and molecules generated during electrosurgical treatment. The aim of the study was to determine spectroscopic features which are typical for healthy and neoplastic breast tissue allowing for future real-time tissue differentiation and margin assessment during breast cancer surgery. A total of 972 spectra generated by electrosurgical sparking on normal and abnormal tissue were used for support vector classifier (SVC) training. Specific spectroscopic features were selected for the classification of tissues in the included breast cancer patients. The average classification accuracy for all patients was 96.9%. Normal and abnormal breast tissue could be differentiated with a mean sensitivity of 94.8%, a specificity of 99.0%, a positive predictive value (PPV) of 99.1% and a negative predictive value (NPV) of 96.1%. For 66.6% patients all classifications reached 100%. Based on this convincing data, a future clinical application of OES-based tissue differentiation in breast cancer surgery seems to be feasible.

11.
Surg Endosc ; 27(10): 3852-9, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23670744

RESUMO

BACKGROUND: Various surgical procedures for hysterectomy exist; with laparoscopic supracervical hysterectomy (LASH) becoming an established option in recent years. Therefore, energy-based technologies for rapid tissue sealing and cutting are in the focus of surgeons. The aim of this trial was to prove or disprove investigated noninferiority of the novel device BiCision in comparison to the widely used UltraCision in a routine procedure ( www.clinicaltrials.gov ; study identifier NCT01806012). METHODS: Thirty LASH procedures were performed with UltraCision and BiCision after randomization of the preparation sides. The primary end point was the resection time per side and instrument. The instruments were also compared concerning blood loss and coagulation and cutting qualities as well as postoperative complications. The patients were followed for 3 months. RESULTS: Mean preparation time per side was 8.8 ± 1.8 min for BiCision and 8.3 ± 1.9 min for UltraCision (p = 0.31), which was not significantly different. Both instruments achieved complete transection without the need of additional cutting attempts. BiCision was significantly superior regarding the number of coagulations for complete hemostasis before and after the removal of the uterine corpus (before: 6.9 ± 4.8 for BiCision and 8.6 ± 4.1 for UltraCision, p = 0.047; after: 5.4 ± 1.2 for BiCision and 8.6 ± 3.2 for UltraCision, p < 0.0001) and intraoperative blood loss (score 1.07 ± 0.25 for BiCision vs. 1.63 ± 0.49 for UltraCision, p < 0.0001). Tissue sticking to the instrument occurred less often on the BiCision side (score 0.14 ± 0.35 for BiCision vs. 0.60 ± 0.81 for UltraCision, p = 0.015). BiCision showed a significantly better fixation of the tissue (grip score 0.23 ± 0.43 for BiCision vs. 1.00 ± 0.74 for UltraCision, p < 0.0001). No intraoperative or postoperative complications were seen for both instruments. CONCLUSIONS: The efficacy and quality of vessel sealing and cutting with BiCision is not inferior to the UltraCision device. Resection time was comparable, and complete hemostasis could be achieved faster in a clinical setting. Therefore, BiCision is at least as reliable as UltraCision for laparoscopic indications.


Assuntos
Eletrocoagulação/instrumentação , Histerectomia/instrumentação , Laparoscopia/métodos , Adulto , Desenho de Equipamento , Feminino , Seguimentos , Hemostasia Cirúrgica/instrumentação , Humanos , Histerectomia/métodos , Leiomioma/cirurgia , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Hemorragia Uterina/cirurgia , Neoplasias Uterinas/cirurgia
12.
Pathologie (Heidelb) ; 44(Suppl 3): 183-187, 2023 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-37966557

RESUMO

Over the last century, there has been a steady development of new technologies for intraoperative tissue identification and differentiation. The applications are varied, with the core purpose being to identify target structures while preserving adjacent tissue and thereby follow a general paradigm of minimally invasive medicine. Particularly in oncology, a further asset of these technologies is the identification or classification of neoplastic tissue to support and improve therapy, for example, in breast cancer surgery.Many technologies under consideration make use of the different physical characteristics of treated tissues, such as induced fluorescence, optical coherence, and electrical impedance.Recent developments are focusing on moving from ex vivo to in situ and from asynchronous to real-time assistance of the clinicians, for example, by means of optical emission spectroscopy. Refinements of existing and the creation of new methods will include AI tools to make them more powerful while reducing the inter-operator variability in operative interventions. This talk addresses several aspects of the usage and suitability of these technologies for intraoperative, therapy-supporting application.


Assuntos
Neoplasias da Mama , Mama , Humanos , Feminino , Mama/cirurgia , Neoplasias da Mama/cirurgia
13.
Gastrointest Endosc ; 76(6): 1142-51, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23021160

RESUMO

BACKGROUND: New therapies are needed for pancreatic cancer. OBJECTIVE: To determine the feasibility and safety of a new endoscopic treatment. Secondary endpoints were to determine effects on tumor growth measured with CT scan and to find the overall survival. DESIGN: A cohort study of patients with local progression of advanced pancreatic adenocarcinoma after neoadjuvant therapy. The cryotherm probe (CTP), a flexible bipolar device that combines radiofrequency with cryogenic cooling, was used under EUS guidance. SETTING: San Raffaele Hospital, Milan, Italy; University Medical Center, Hamburg-Eppendorf, Germany. PATIENTS: A total of 22 patients (male/female 11/11; mean age 61.9 years) were enrolled from September 2009 to May 2011. INTERVENTION: Radiofrequency heating: 18 W; pressure for cooling: 650 psi (Pounds per Square Inch); application time: depending on tumor size. MAIN OUTCOME MEASUREMENTS: Feasibility was evaluated during the procedure. A clinical and radiologic follow-up was planned. RESULTS: The CTP was successfully applied in 16 patients (72.8%); in 6 it was not possible because of stiffness of the GI wall and of the tumor. Amylase arose in 3 of 16 patients; none had clinical signs of pancreatitis. Late complications arose in 4 cases: 3 were mostly related to tumor progression. Median postablation survival time was 6 months. A CT scan was performed in all patients, but only in 6 of 16 was it possible to clearly define the tumor margins after ablation. In these patients, the tumor appeared smaller compared with the initial mass (P = .07). LIMITATIONS: Small sample of patients, difficulty of objectifying the size of the ablated zone by CT scan. CONCLUSION: EUS-guided CTP ablation is feasible and safe. Further investigations are needed to demonstrate progression-free survival and local control.


Assuntos
Adenocarcinoma/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Endossonografia , Neoplasias Pancreáticas/cirurgia , Ultrassonografia de Intervenção , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/mortalidade , Adenocarcinoma/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Quimiorradioterapia Adjuvante , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Terapia Neoadjuvante , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/mortalidade , Neoplasias Pancreáticas/terapia , Complicações Pós-Operatórias , Estudos Prospectivos , Taxa de Sobrevida , Resultado do Tratamento
14.
Brain Sci ; 11(2)2021 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-33673036

RESUMO

People living with a degenerative retinal disease such as retinitis pigmentosa are oftentimes faced with difficulties navigating in crowded places and avoiding obstacles due to their severely limited field of view. The study aimed to assess the potential of different patterns of eye movement (scanning patterns) to (i) increase the effective area of perception of participants with simulated retinitis pigmentosa scotoma and (ii) maintain or improve performance in visual tasks. Using a virtual reality headset with eye tracking, we simulated tunnel vision of 20° in diameter in visually healthy participants (n = 9). Employing this setup, we investigated how different scanning patterns influence the dynamic field of view-the average area over time covered by the field of view-of the participants in an obstacle avoidance task and in a search task. One of the two tested scanning patterns showed a significant improvement in both dynamic field of view (navigation 11%, search 7%) and collision avoidance (33%) when compared to trials without the suggested scanning pattern. However, participants took significantly longer (31%) to finish the navigation task when applying this scanning pattern. No significant improvements in search task performance were found when applying scanning patterns.

15.
Ann Gastroenterol ; 34(6): 845-851, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34815651

RESUMO

BACKGROUND: Thermal damage to the muscle layer during mucosal application of argon plasma coagulation (APC) may be avoided by creating a fluid cushion within the submucosal layer, but the minimum injection volume needed or the ideal injection fluid are yet to be established. We conducted a systematic ex vivo study with this aim. METHODS: All experiments were performed in an ex vivo porcine gastrointestinal tract model. Five different fluids (saline, Glyceol, Gelafundin, Voluven, and Eleview) of different volumes were injected into the submucosa of different parts of the gastrointestinal tract. APC was applied to the mucosa at different power settings. Immediately after APC treatment, the temperature was measured through a thermocouple placed inside the fluid cushion, just on top of the muscle layer. The minimum volume of fluid needed to protect the muscle layer from thermal damage was determined. RESULTS: There was no difference in the temperature measured among the different injection fluids at the surface of the muscle, in all the locations, at equal injection volumes and power settings. The minimum amounts of fluid needed to protect the muscle layer were 2 and 3 mL for power settings of 30-90 W and 90-120 W, respectively. CONCLUSIONS: Normal saline and 4 commercially available submucosal injection fluids possess similar thermal protective effects. To reduce the likelihood of thermal damage to deeper layers when APC is applied, a minimum injection volume of 3 mL is recommended if less than 90 W power will be utilized over 3 sec.

16.
Gastrointest Endosc ; 71(7): 1294-7, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20598256

RESUMO

BACKGROUND: Ablative therapies such as radiofrequency and cryotechnology are widely used in oncological intervention but not in the pancreatic field because of their high operative risks. A new flexible bipolar ablation device (Cryotherm probe [CTP]) was developed combining radiofrequency and cryotechnology. OBJECTIVE: To evaluate the efficacy of the CTP in destroying neoplastic tissue of explanted pancreatic tumors of patients with pancreatic adenocarcinoma. DESIGN: Ex vivo clinical study. SETTING: Inpatient hospital setting. PATIENTS: This study involved 16 explanted pancreatic tumors from 16 patients. INTERVENTIONS: CTP application was performed on explanted pancreatic tumors. Anatomic specimens were divided into 4 groups; each group received a predefined application time of 120 to 600 seconds. MAIN OUTCOME MEASUREMENTS: The coagulation diameter (short axis) perpendicular to the device's longitudinal axis was used as the primary outcome measure. RESULTS: All pancreatic specimens showed histological signs of coagulative necrosis. There was a positive correlation between the short axis of the obtained necrosis and duration of application (r = 0.74). LIMITATIONS: This study was an ex vivo study with all limitations typical of this kind of study. CONCLUSIONS: The CTP is effective in destroying neoplastic pancreatic tissue, creating an ablation zone, the extent of which is related to the duration of application.


Assuntos
Adenocarcinoma/cirurgia , Ablação por Cateter/instrumentação , Criocirurgia/instrumentação , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/cirurgia , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Necrose/patologia , Pâncreas/patologia , Pâncreas/cirurgia , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Estudos Retrospectivos , Resultado do Tratamento , Ultrassonografia
17.
PLoS One ; 15(8): e0237344, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32818953

RESUMO

PURPOSE: In this study, we investigate to what degree augmented reality technology can be used to create and evaluate a visual-to-auditory sensory substitution device to improve the performance of blind persons in navigation and recognition tasks. METHODS: A sensory substitution algorithm that translates 3D visual information into audio feedback was designed. This algorithm was integrated in an augmented reality based mobile phone application. Using the mobile device as sensory substitution device, a study with blind participants (n = 7) was performed. The participants navigated through pseudo-randomized obstacle courses using either the sensory substitution device, a white cane or a combination of both. In a second task, virtual 3D objects and structures had to be identified by the participants using the same sensory substitution device. RESULTS: The realized application for mobile devices enabled participants to complete the navigation and object recognition tasks in an experimental environment already within the first trials without previous training. This demonstrates the general feasibility and low entry barrier of the designed sensory substitution algorithm. In direct comparison to the white cane, within the study duration of ten hours the sensory substitution device did not offer a statistically significant improvement in navigation.


Assuntos
Realidade Aumentada , Cegueira/reabilitação , Tecnologia Assistiva , Navegação Espacial/fisiologia , Pessoas com Deficiência Visual/reabilitação , Adulto , Idoso , Percepção Auditiva/fisiologia , Cegueira/fisiopatologia , Bengala , Estudos de Viabilidade , Retroalimentação Sensorial/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aplicativos Móveis , Projetos Piloto , Percepção Visual/fisiologia , Adulto Jovem
18.
J Med Chem ; 51(7): 2158-69, 2008 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-18324762

RESUMO

Human 17beta-hydroxysteroid dehydrogenase type 1 (17beta-HSD1) catalyzes the reduction of the weak estrogen estrone (E1) to the highly potent estradiol (E2). This reaction takes place in the target cell where the estrogenic effect is exerted via the estrogen receptor (ER). Estrogens, especially E2, are known to stimulate the proliferation of hormone-dependent diseases. 17beta-HSD1 is overexpressed in many breast tumors. Thus, it is an attractive target for the treatment of these diseases. Ligand- and structure-based drug design led to the discovery of novel, selective, and potent inhibitors of 17beta-HSD1. Phenyl-substituted bicyclic moieties were synthesized as mimics of the steroidal substrate. Computational methods were used to obtain insight into their interactions with the protein. Compound 5 turned out to be a highly potent inhibitor of 17beta-HSD1 showing good selectivity (17beta-HSD2, ERalpha and beta), medium cell permeation, reasonable metabolic stability (rat hepatic microsomes), and little inhibition of hepatic CYP enzymes.


Assuntos
17-Hidroxiesteroide Desidrogenases/antagonistas & inibidores , Inibidores Enzimáticos/síntese química , Inibidores Enzimáticos/farmacologia , Estrogênios/metabolismo , Naftalenos/síntese química , Naftalenos/farmacologia , Neoplasias Hormônio-Dependentes/tratamento farmacológico , Neoplasias Hormônio-Dependentes/enzimologia , Quinolinas/síntese química , Quinolinas/farmacologia , Animais , Hidrocarboneto de Aril Hidroxilases/antagonistas & inibidores , Sítios de Ligação , Células CACO-2 , Simulação por Computador , Desenho de Fármacos , Inibidores Enzimáticos/química , Humanos , Ligação de Hidrogênio , Fígado/enzimologia , Masculino , Microssomos Hepáticos/metabolismo , Modelos Moleculares , Estrutura Molecular , Naftalenos/química , Quinolinas/química , Ratos , Ratos Sprague-Dawley , Estereoisomerismo , Relação Estrutura-Atividade
19.
Bioorg Med Chem ; 16(12): 6423-35, 2008 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-18514529

RESUMO

The 17beta-hydroxysteroid dehydrogenase type 1 (17beta-HSD1) catalyses the reduction of the weakly active estrone (E1) into the most potent estrogen, 17beta-estradiol (E2). E2 stimulates the growth of hormone-dependent diseases via activation of the estrogen receptors (ERs). 17beta-HSD1 is often over-expressed in breast cancer cells. Thus, it is an attractive target for the treatment of mammary tumours. The combination of a ligand- and a structure-based drug design approach led to the identification of bis(hydroxyphenyl) azoles as potential inhibitors of 17beta-HSD1. Different azoles and hydroxy substitution patterns were investigated. The compounds were evaluated for activity and selectivity with regard to 17beta-HSD2, ERalpha and ERbeta. The most potent compound is 3-[5-(4-hydroxyphenyl)-1,3-oxazol-2-yl]phenol (18, IC(50)=0.31 microM), showing very good selectivity, high cell permeability and medium CaCo-2 permeability.


Assuntos
17-Hidroxiesteroide Desidrogenases/antagonistas & inibidores , Antineoplásicos Hormonais/química , Antineoplásicos Hormonais/farmacologia , Azóis/química , Azóis/farmacologia , Inibidores Enzimáticos/química , Inibidores Enzimáticos/farmacologia , Antagonistas de Estrogênios/química , Antagonistas de Estrogênios/farmacologia , 17-Hidroxiesteroide Desidrogenases/química , Antineoplásicos Hormonais/síntese química , Azóis/síntese química , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/metabolismo , Células CACO-2 , Desenho de Fármacos , Inibidores Enzimáticos/síntese química , Antagonistas de Estrogênios/síntese química , Estrogênios/metabolismo , Humanos , Modelos Moleculares , Estrutura Molecular , Permeabilidade , Relação Estrutura-Atividade
20.
J Med Chem ; 50(19): 4665-8, 2007 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-17705363

RESUMO

We describe a collection of structurally diverse inhibitors of protein-protein-interactions (PPIs). This collection is compared against the FDA drug database and a subset of the ZINC database by machine learning methods which rely on classical QSAR descriptors. We obtain a decision tree that contains three descriptors. Of particular importance is a constitutional descriptor related to molecular shape and size. Validation of the decision tree by various procedures indicates that it does not result from chance correlations and has predictive value. We conclude that constitutional descriptors may be valuable tools in the preselection of potential PPI inhibitors from compound databases.


Assuntos
Inteligência Artificial , Árvores de Decisões , Informática/métodos , Preparações Farmacêuticas/química , Proteínas/química , Relação Quantitativa Estrutura-Atividade , Bases de Dados Factuais , Peso Molecular , Preparações Farmacêuticas/metabolismo , Ligação Proteica/efeitos dos fármacos , Estados Unidos , United States Food and Drug Administration
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA