Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Philos Trans A Math Phys Eng Sci ; 377(2137)2018 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-30530544

RESUMO

The dome of Santa Maria del Fiore, Florence Cathedral, was built between 1420 and 1436 by architect Filippo Brunelleschi and it is now cracking under its own weight. Engineering efforts are under way to model the dome's structure and reinforce it against further deterioration. According to some scholars, Brunelleschi might have built reinforcement structures into the dome itself; however, the only known reinforcement is a wood chain 7.75 m above the springing of the Cupola. Multiple scattering muon radiography is a non-destructive imaging method that can be used to image the interior of the dome's wall and therefore ascertain the layout and status of any iron substructure in it. A demonstration measurement was performed at the Los Alamos National Laboratory on a mock-up wall to show the feasibility of the work proposed, and a lightweight and modular imaging system is currently under construction. We will discuss here the results of the demonstration measurement and the potential of the proposed technique, describe the imaging system under construction and outline the plans for the measurement.This article is part of the Theo Murphy meeting issue 'Cosmic-ray muography'.

2.
IEEE Trans Nucl Sci ; 61(3): 1092-1098, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25246711

RESUMO

This paper describes the design and performance of a high spatial resolution PET detector with time-of-flight capabilities. With an emphasis on high spatial resolution and sensitivity, we initially evaluated the performance of several 1.5 × 1.5 and 2.0 × 2.0 mm2 and 12-15 mm long LYSO crystals read out by several appropriately sized PMTs. Experiments to evaluate the impact of reflector on detector performance were performed and the final detector consisted of a 32 × 32 array of 1.5 × 1.5 × 15 mm3 LYSO crystals packed with a diffuse reflector and read out by a single Hamamatsu 64 channel multi-anode PMT. Such a design made it compact, modular and offered a cost-effective solution to obtaining excellent energy and timing resolution. To minimize the number of readout signals, a compact front-end readout electronics that summed anode signals along each of the orthogonal directions was also developed. Experimental evaluation of detector performance demonstrates clear discrimination of the crystals within the detector. An average energy resolution (FWHM) of 12.7 ± 2.6% and average coincidence timing resolution (FWHM) of 348 ps was measured, demonstrating suitability for use in the development of a high spatial resolution time-of-flight scanner for dedicated breast PET imaging.

3.
IEEE Trans Nucl Sci ; 61(3): 1174-1181, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25484379

RESUMO

Waveform sampling is an appealing technique for instruments requiring precision time and pulse-height measurements. Sampling each PMT waveform at oscilloscope-like rates of several gigasamples per second enables one to process PMT signals digitally, which in turn makes it straightforward to optimize timing resolution and amplitude (energy and position) resolution in response to calibration effects, pile-up effects, and other systematic sources of waveform variation. We describe a system design and preliminary implementation that neatly maps waveform-sampling technology onto the LaPET prototype whole-body time-of-flight PET scanner that serves as the platform for testing this new technology.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA