1.
J Appl Clin Med Phys ; 25(5): e14295, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38335253

RESUMO

PURPOSE/OBJECTIVE: Field size limitations on Halcyon and Ethos treatment machines largely preclude use of the conventional monoisocentric three-field technique for breast/chest wall and regional lymph nodes. We present an alternative, IMRT-based planning approach that facilitates treatment on Halcyon and Ethos while preserving plan quality. MATERIALS/METHODS: Eight breast and regional node cases (four left-sided, four right-sided) were planned for an Ethos machine using a 15-17 field IMRT technique. Institutional plan quality metrics for CTV and PTV coverage and OAR sparing were assessed. Five plans (four right-sided, one left-sided) were also planned using a hybrid 3D multisocenter technique. CTV coverage and OAR sparing were compared to the IMRT plans. Eclipse scripting tools were developed to aid in beam placement and plan evaluation through a set of dosimetric scorecards, and both are shared publicly. RESULTS: On average, the IMRT plans achieved breast CTV and PTV coverage at 50 Gy of 97.9% and 95.7%, respectively. Supraclavicular CTV and PTV coverages at 45 Gy were 100% and 95.5%. Axillary lymph node CTV and PTV coverages at 45 Gy were 100% and 97.1%, and IMN CTV coverage at 45 Gy was 99.2%. Mean ipsilateral lung V20 Gy was 19.3%, and average mean heart dose was 1.6 Gy for right-sided cases and 3.0 Gy for left-sided. In comparison to the hybrid 3D plans, IMRT plans achieved higher breast and supraclavicular CTV coverage (99.9% vs. 98.6% and 99.9% vs. 93.4%), higher IMN coverage (99.6% vs. 78.2%), and lower ipsilateral lung V20 Gy (19.6% vs. 28.2%). CONCLUSION: Institutional plan quality benchmarks were achieved for all eight cases using the IMRT-based planning approach. The IMRT-based planning approach offered superior conformity and OAR sparing than a competing hybrid 3D approach.


Assuntos
Neoplasias da Mama , Linfonodos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Parede Torácica , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Feminino , Parede Torácica/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Neoplasias da Mama/radioterapia , Linfonodos/efeitos da radiação
2.
J Appl Clin Med Phys ; 25(5): e14313, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38650177

RESUMO

BACKGROUND: This study utilizes interviews of clinical medical physicists to investigate self-reported shortcomings of the current weekly chart check workflow and opportunities for improvement. METHODS: Nineteen medical physicists were recruited for a 30-minute semi-structured interview, with a particular focus placed on image review and the use of automated tools for image review in weekly checks. Survey-type questions were used to gather quantitative information about chart check practices and importance placed on reducing chart check workloads versus increasing chart check effectiveness. Open-ended questions were used to probe respondents about their current weekly chart check workflow, opinions of the value of weekly chart checks and perceived shortcomings, and barriers and facilitators to the implementation of automated chart check tools. Thematic analysis was used to develop common themes across the interviews. RESULTS: Physicists ranked highly the value of reducing the time spent on weekly chart checks (average 6.3 on a scale from 1 to 10), but placed more value on increasing the effectiveness of checks with an average of 9.2 on a 1-10 scale. Four major themes were identified: (1) weekly chart checks need to adapt to an electronic record-and-verify chart environment, (2) physicists could add value to patient care by analyzing images without duplicating the work done by physicians, (3) greater support for trending analysis is needed in weekly checks, and (4) automation has the potential to increase the value of physics checks. CONCLUSION: This study identified several key shortcomings of the current weekly chart check process from the perspective of the clinical medical physicist. Our results show strong support for automating components of the weekly check workflow in order to allow for more effective checks that emphasize follow-up, trending, failure modes and effects analysis, and allow time to be spent on other higher value tasks that improve patient safety.


Assuntos
Fluxo de Trabalho , Humanos , Física Médica , Inquéritos e Questionários , Processamento de Imagem Assistida por Computador/métodos , Automação , Garantia da Qualidade dos Cuidados de Saúde/normas , Entrevistas como Assunto/métodos
3.
J Appl Clin Med Phys ; 24(9): e14016, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37165761

RESUMO

PURPOSE: Automation and computer assistance can support quality assurance tasks in radiotherapy. Retrospective image review requires significant human resources, and automation of image review remains a noteworthy missing element in previous work. Here, we present initial findings from a proof-of-concept clinical implementation of an AI-assisted review of CBCT registrations used for patient setup. METHODS: An automated pipeline was developed and executed nightly, utilizing python scripts to interact with the clinical database through DICOM networking protocol and automate data retrieval and analysis. A previously developed artificial intelligence (AI) algorithm scored CBCT setup registrations based on misalignment likelihood, using a scale from 0 (most unlikely) through 1 (most likely). Over a 45-day period, 1357 pre-treatment CBCT registrations from 197 patients were retrieved and analyzed by the pipeline. Daily summary reports of the previous day's registrations were produced. Initial action levels targeted 10% of cases to highlight for in-depth physics review. A validation subset of 100 cases was scored by three independent observers to characterize AI-model performance. RESULTS: Following an ROC analysis, a global threshold for model predictions of 0.87 was determined, with a sensitivity of 100% and specificity of 82%. Inspecting the observer scores for the stratified validation dataset showed a statistically significant correlation between observer scores and model predictions. CONCLUSION: In this work, we describe the implementation of an automated AI-analysis pipeline for daily quantitative analysis of CBCT-guided patient setup registrations. The AI-model was validated against independent expert observers, and appropriate action levels were determined to minimize false positives without sacrificing sensitivity. Case studies demonstrate the potential benefits of such a pipeline to bolster quality and safety programs in radiotherapy. To the authors' knowledge, there are no previous works performing AI-assisted assessment of pre-treatment CBCT-based patient alignment.


Assuntos
Radioterapia Guiada por Imagem , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Inteligência Artificial , Tomografia Computadorizada de Feixe Cônico/métodos , Estudos Retrospectivos , Radioterapia Guiada por Imagem/métodos
4.
Biomed Phys Eng Express ; 10(2)2024 02 29.
Artigo em Inglês | MEDLINE | ID: mdl-38382110

RESUMO

Objective. In image-guided radiotherapy (IGRT), off-by-one vertebral body misalignments are rare but potentially catastrophic. In this study, a novel detection method for such misalignments in IGRT was investigated using densely-connected convolutional networks (DenseNets) for applications towards real-time error prevention and retrospective error auditing.Approach. A total of 4213 images acquired from 527 radiotherapy patients aligned with planar kV or MV radiographs were used to develop and test error-detection software modules. Digitally reconstructed radiographs (DRRs) and setup images were retrieved and co-registered according to the clinically applied alignment contained in the DICOM REG files. A semi-automated algorithm was developed to simulate patient positioning errors on the anterior-posterior (AP) and lateral (LAT) images shifted by one vertebral body. A DenseNet architecture was designed to classify either AP images individually or AP and LAT image pairs. Receiver-operator characteristic curves (ROC) and areas under the curves (AUC) were computed to evaluate the classifiers on test subsets. Subsequently, the algorithm was applied to the entire dataset in order to retrospectively determine the absolute off-by-one vertebral body error rate for planar radiograph guided RT at our institution from 2011-2021.Main results. The AUCs for the kV models were 0.98 for unpaired AP and 0.99 for paired AP-LAT. The AUC for the MV AP model was 0.92. For a specificity of 95%, the paired kV model achieved a sensitivity of 99%. Application of the model to the entire dataset yielded a per-fraction off-by-one vertebral body error rate of 0.044% [0.0022%, 0.21%] for paired kV IGRT including one previously unreported error.Significance. Our error detection algorithm was successful in classifying vertebral body positioning errors with sufficient accuracy for retrospective quality control and real-time error prevention. The reported positioning error rate for planar radiograph IGRT is unique in being determined independently of an error reporting system.


Assuntos
Radioterapia Guiada por Imagem , Corpo Vertebral , Humanos , Estudos Retrospectivos , Radiografia , Radioterapia Guiada por Imagem/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
5.
Int J Radiat Oncol Biol Phys ; 118(5): 1181-1191, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38160916

RESUMO

PURPOSE: Real-time intrafraction tracking/gating is an integral component of magnetic resonance imaging-guided radiation therapy (MRgRT) and may have contributed to the acute toxicity reduction during prostate stereotactic body radiation therapy observed on the MRgRT-arm of the MIRAGE (MAGNETIC RESONANCE IMAGING-GUIDED Stereotactic Body Radiotherapy for Prostate Cancer) randomized trial (NCT04384770). Herein we characterized intrafraction prostate motion and assessed gating effectiveness. METHODS AND MATERIALS: Seventy-nine patients were treated on an MR-LINAC. Real-time cine imaging was acquired at 4Hz in a sagittal plane. If >10% of the prostate area moved outside of a 3-mm gating boundary, an automatic beam hold was initiated. An in-house tool was developed to retrospectively extract gating signal for all patients and identify the tracked prostate in each cine frame for a subgroup of 40 patients. The fraction of time the prostate was within the gating window was defined as the gating duty cycle (GDC). RESULTS: A total of 391 treatments from 79 patients were analyzed. Median GDC was 0.974 (IQR, 0.916-0.983). Fifty (63.2%) and 24 (30.4%) patients had at least 1 fraction with GDC ≤0.9 and GDC ≤0.8, respectively. Incidence of low GDC fractions among patients appeared stochastic. Patients with minimum GDC <0.8 trended toward more frequent grade 2 genitourinary toxicity compared with those with minimum GDC >0.8 (38% vs 18%, P = .065). Prostate intrafraction motion was mostly along the bladder-rectum axis and predominantly in the superior-anterior direction. Motion in the inferior-posterior direction was associated with significantly higher rate of acute grade 2 genitourinary toxicity (66.7% vs 13.9%, P = .001). Gating limited mean prostate motion during treatment delivery in fractions with a GDC <0.9 (<0.8) to 2.9 mm (2.9 mm) versus 4.1 mm (4.7 mm) for ungated motion. CONCLUSIONS: Fractions with large intrafraction motion were associated with increased toxicity and their occurrence among patients appears stochastic. Real-time tracking/gating effectively mitigated this motion and is likely a major contributing factor of acute toxicity reduction associated with MRgRT.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Masculino , Humanos , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , Imageamento por Ressonância Magnética/métodos
6.
Int J Radiat Oncol Biol Phys ; 120(1): 243-252, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38485098

RESUMO

PURPOSE: Present knowledge of patient setup and alignment errors in image guided radiation therapy (IGRT) relies on voluntary reporting, which is thought to underestimate error frequencies. A manual retrospective patient-setup misalignment error search is infeasible owing to the bulk of cases to be reviewed. We applied a deep learning-based misalignment error detection algorithm (EDA) to perform a fully automated retrospective error search of clinical IGRT databases and determine an absolute gross patient misalignment error rate. METHODS AND MATERIALS: The EDA was developed to analyze the registration between planning scans and pretreatment cone beam computed tomography scans, outputting a misalignment score ranging from 0 (most unlikely) to 1 (most likely). The algorithm was trained using simulated translational errors on a data set obtained from 680 patients treated at 2 radiation therapy clinics between 2017 and 2022. A receiver operating characteristic analysis was performed to obtain target thresholds. DICOM Query and Retrieval software was integrated with the EDA to interact with the clinical database and fully automate data retrieval and analysis during a retrospective error search from 2016 to 2017 and from 2021 to 2022 for the 2 institutions, respectively. Registrations were flagged for human review using both a hard-thresholding method and a prediction trending analysis over each individual patient's treatment course. Flagged registrations were manually reviewed and categorized as errors (>1 cm misalignment at the target) or nonerrors. RESULTS: A total of 17,612 registrations were analyzed by the EDA, resulting in 7.7% flagged events. Three previously reported errors were successfully flagged by the EDA, and 4 previously unreported vertebral body misalignment errors were discovered during case reviews. False positive cases often displayed substantial image artifacts, patient rotation, and soft tissue anatomy changes. CONCLUSIONS: Our results validated the clinical utility of the EDA for bulk image reviews and highlighted the reliability and safety of IGRT, with an absolute gross patient misalignment error rate of 0.04% ± 0.02% per delivered fraction.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Radioterapia Guiada por Imagem , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Radioterapia Guiada por Imagem/métodos , Inteligência Artificial , Bases de Dados Factuais , Erros de Configuração em Radioterapia , Algoritmos , Estudos Retrospectivos , Aprendizado Profundo , Planejamento da Radioterapia Assistida por Computador/métodos , Curva ROC
7.
Int J Radiat Oncol Biol Phys ; 118(4): 986-997, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-37871887

RESUMO

PURPOSE: Emerging data suggest that trigone dosimetry may be more associated with poststereotactic body radiation therapy (SBRT) urinary toxicity than whole bladder dosimetry. We quantify the dosimetric effect of interfractional displacement and deformation of the whole bladder and trigone during prostate SBRT using on-board, pretreatment 0.35T magnetic resonance images (MRI). METHODS AND MATERIALS: Seventy-seven patients treated with MRI-guided prostate SBRT (40 Gy/5 fractions) on the MRI arm of a phase 3 single-center randomized trial were included. Bladder and trigone structures were contoured on images obtained from a 0.35T simulation MRI and 5 on-board pretreatment MRIs. Dice similarity coefficient (DSC) scores and changes in volume between simulation and daily treatments were calculated. Dosimetric parameters including Dmax, D0.03 cc, Dmean, V40 Gy, V39 Gy, V38 Gy, and V20 Gy for the bladder and trigone for the simulation and daily treatments were collected. Both physician-scored (Common Terminology Criteria for Adverse Events, version 4.03 scale) as well as patient-reported (International Prostate Symptom Scores and the Expanded Prostate Cancer Index Composite-26 scores) acute genitourinary (GU) toxicity outcomes were collected and analyzed. RESULTS: The average treatment bladder volume was about 30% smaller than the simulation bladder volume; however, the trigone volume remained fairly consistent despite being positively correlated with total bladder volume. Overall, the trigone accounted for <2% of the bladder volume. Median DSC for the bladder was 0.79, whereas the median DSC of the trigone was only 0.33. No statistically significant associations between our selected bladder and trigonal dosimetric parameters and grade ≥2 GU toxicity were identified, although numerically, patients with GU toxicity (grade ≥2) had higher intermediate doses to the bladder (V20 Gy and Dmean) and larger volumes exposed to higher doses in the trigone (V40 Gy, V39 Gy, and V38 Gy). CONCLUSIONS: The trigone exhibits little volume change, but considerable interfractional displacement/deformation. As a result, the relative volume of the trigone receiving high doses during prostate SBRT varies substantially between fractions, which could influence GU toxicity and may not be predicted by radiation planning dosimetry.


Assuntos
Neoplasias da Próstata , Exposição à Radiação , Radiocirurgia , Masculino , Humanos , Bexiga Urinária/efeitos da radiação , Próstata/diagnóstico por imagem , Próstata/patologia , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia
8.
Radiother Oncol ; 167: 203-210, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34979212

RESUMO

BACKGROUND AND PURPOSE: Interfraction volumetric changes/rotations in the prostate and proximal seminal vesicles (SVs) might compromise target coverage when tight margins are used for prostate stereotactic body radiotherapy (SBRT). We investigated on-board MRI images from MRI-guided SBRT to better understand this. MATERIALS AND METHODS: Twenty consecutive patients treated with MRI-guided prostate SBRT (40 Gy/5 fractions) enrolled on the MRI arm of a phase III randomized trial were included. A 2 mm isotropic margin was used for prostate and proximal SVPTV. Target volume, prostate dimensions, angles of the proximal SV on axial (angle α) and sagittal view (angle θ) were measured on a 0.35 T simulation MRI and five on-board pre-treatment MRIs. Dice coefficient of the targets and target dosimetry were calculated. RESULTS: All patients experienced an isotropic increase in prostate volume during SBRT (p = 0.0016): 0.1%, 9.0%, 12.1%, 15.1%, and 14.2% (median) at fractions 1-5, respectively, regardless of baseline volume, which was significantly reduced with neoadjuvant ADT (p = 0.0042). There was minimal interfraction rotation of prostate, however, considerable variations in proximal SV angle α (median 21.5°) and angle θ (median 17.6°) were seen. Median V100% was 97.5% and 87.1% for prostate and proximal SV CTV, respectively. V95%≥95% was achieved in 94% of fractions for the prostate and in 59% for proximal SV. CONCLUSION: Prostate volume consistently increased during SBRT. Interfraction prostatic rotation was minimal while rotation of the proximal SV was considerable. Prostate dosimetry was favorable, but online adaptive therapy may be indicated occasionally to account for prostatic swelling and in particular proximal SV rotations.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Humanos , Imageamento por Ressonância Magnética , Masculino , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Glândulas Seminais/diagnóstico por imagem , Tomografia Computadorizada por Raios X
9.
Br J Radiol ; 91(1082): 20170597, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29099616

RESUMO

OBJECTIVE: A recently proposed "5DCT" protocol uses deformable registration of free-breathing fast-helical CT scans to generate a breathing motion model. In order to allow accurate registration, free-breathing images are required to be free of doubling-artefacts, which arise when tissue motion is greater than scan speed. METHODS: Using a unique set of digital phantoms based on patient data and verified with a motion phantom, this work identifies the minimum scanner parameters required to successfully generate free-breathing artefact-free fast-helical scans. A motion phantom and 5 patients were imaged 25 times under free-breathing conditions in alternating directions with a 64-slice CT scanner employing a low-dose fast-helical protocol. A series of high temporal resolution (0.1 s) 5DCT scan data sets was generated in each case. A simulated CT scanner was used to "image" each free-breathing data set. Various CT scanner detector widths and rotation times were simulated, and verified using the motion phantom results. Motion-induced artefacts were quantified in patient images using structural similarity maps to determine the similarity between axial slices. RESULTS: Increasing amounts of motion-induced artefacts were observed with increasing rotation times >0.2 s for 16 mm detector configuration. CONCLUSION: The current generation of 16-slice CT scanners, which are present in the majority of Radiation Oncology departments, are not capable of generating free-breathing sorting artefact-free images required for 5DCT. Advances in knowledge: A recently proposed "5DCT" protocol uses deformable registration of free-breathing fast-helical CT scans to generate a breathing motion model. In order to allow accurate registration, free-breathing images are required to be free of doubling-artefacts, which arise when tissue motion is greater than scan speed. The results suggest that the current generation of 16-slice CT scanners, present in the majority of Radiation Oncology departments, are not capable of generating the free-breathing images required for 5DCT.


Assuntos
Artefatos , Pulmão/diagnóstico por imagem , Movimento (Física) , Respiração , Tomografia Computadorizada Espiral/métodos , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
10.
Med Phys ; 41(4): 043501, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24694158

RESUMO

PURPOSE: The purpose of this work is to develop a cardiac-induced lung motion model to be integrated into an existing breathing motion model. METHODS: The authors' proposed cardiac-induced lung motion model represents the lung tissue's specific response to the subject's cardiac cycle. The model is mathematically defined as a product of a converging polynomial function h of the cardiac phase (c) and the maximum displacement y(X0) of each voxel (X0) among all the cardiac phases. The function h(c) was estimated from cardiac-gated MR imaging of ten healthy volunteers using an Akaike Information Criteria optimization algorithm. For each volunteer, a total of 24 short-axis and 18 radial planar views were acquired on a 1.5 T MR scanner during a series of 12-15 s breath-hold maneuvers. Each view contained 30 temporal frames of equal time-duration beginning with the end-diastolic cardiac phase. The frames in each of the planar views were resampled to create a set of three-dimensional (3D) anatomical volumes representing thoracic anatomy at different cardiac phases. A 3D multiresolution optical flow deformable image registration algorithm was used to quantify the difference in tissue position between the end-diastolic cardiac phase and the remaining cardiac phases. To account for image noise, voxel displacements whose maximum values were less than 0.3 mm, were excluded. In addition, the blood vessels were segmented and excluded in order to eliminate registration artifacts caused by blood-flow. RESULTS: The average cardiac-induced lung motions for displacements greater than 0.3 mm were found to be 0.86 ± 0.74 and 0.97 ± 0.93 mm in the left and right lungs, respectively. The average model residual error for the ten healthy volunteers was found to be 0.29 ± 0.08 mm in the left lung and 0.38 ± 0.14 mm in the right lung for tissue displacements greater than 0.3 mm. The relative error decreased with increasing cardiac-induced lung tissue motion. While the relative error was > 60% for submillimeter cardiac-induced lung tissue motion, the relative error decreased to < 5% for cardiac-induced lung tissue motion that exceeded 10 mm in displacement. CONCLUSIONS: The authors' studies implied that modeling and including cardiac-induced lung motion would improve breathing motion model accuracy for tissues with cardiac-induced motion greater than 0.3 mm.


Assuntos
Coração/fisiologia , Pulmão/fisiologia , Modelos Biológicos , Movimento , Respiração , Artefatos , Humanos , Imageamento por Ressonância Magnética