Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Appl Opt ; 61(10): 2649-2656, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35471336

RESUMO

The damage of large-aperture optical components caused by organic contamination limits the performance improvement of high-power laser facilities. We propose an in situ plasma cleaning technology to remove the organic contaminants on large-aperture optical components, demonstrated by the simulated equipment. The cleaning characteristics of the equipment were investigated by spectral diagnosis. The cleaning capability coefficient was defined to evaluate the performance of the plasma equipment. Then diffusion properties of reactive species along the surface of optical components were elucidated under various charge parameters, including powers, source frequencies, and gas pressures. We discuss the underlying cleaning mechanism for removing organic contaminants. A new plasma cleaning model is established to predict the treatment time with the cleaning capability coefficient.

2.
Sensors (Basel) ; 22(4)2022 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-35214422

RESUMO

The impact of airborne molecular contaminants (AMCs) on the lifetime of fused silica UV optics in high power lasers (HPLs) is a critical issue. In this work, we demonstrated the on-line monitoring method of AMCs concentration based on the Sagnac microfiber structure. In the experiment, a Sagnac microfiber loop with mesoporous silica coating was fabricated by the microheater brushing technique and dip coating. The physical absorption of AMCs in the mesoporous coating results in modification of the surrounding refractive index (RI). By monitoring the spectral shift in the wavelength domain, the proposed structure can operate as an AMCs concentration sensor. The sensitivity of the AMCs sensor can achieve 0.11 nm (mg/m3). By evaluating the gas discharge characteristic of four different low volatilization greases in a coarse vacuum environment, we demonstrated the feasibility of the proposed sensors. The use of these sensors was shown to be very promising for meeting the requirements of detecting trace amounts of contaminants.

3.
Sensors (Basel) ; 21(22)2021 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-34833512

RESUMO

Stretchable optical fiber sensors (SOFSs), which are promising and ultra-sensitive next-generation sensors, have achieved prominent success in applications including health monitoring, robotics, and biological-electronic interfaces. Here, we report an ultra-sensitive multi-functional optical micro/nanofiber embedded with a flexible polydimethylsiloxane (PDMS) membrane, which is compatible with wearable optical sensors. Based on the effect of a strong evanescent field, the as-fabricated SOFS is highly sensitive to strain, achieving high sensitivity with a peak gauge factor of 450. In addition, considering the large negative thermo-optic coefficient of PDMS, temperature measurements in the range of 30 to 60 °C were realized, resulting in a 0.02 dBm/°C response. In addition, wide-range detection of humidity was demonstrated by a peak sensitivity of 0.5 dB/% RH, with less than 10% variation at each humidity stage. The robust sensing performance, together with the flexibility, enables the real-time monitoring of pulse, body temperature, and respiration. This as-fabricated SOFS provides significant potential for the practical application of wearable healthcare sensors.


Assuntos
Nanofibras , Dispositivos Eletrônicos Vestíveis , Eletrônica , Frequência Cardíaca , Temperatura
4.
Sensors (Basel) ; 17(6)2017 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-28621742

RESUMO

A high sensitivity refractive index sensor based on a single mode-small diameter no core fiber structure is proposed. In this structure, a small diameter no core fiber (SDNCF) used as a sensor probe, was fusion spliced to the end face of a traditional single mode fiber (SMF) and the end face of the SDNCF was coated with a thin film of gold to provide reflective light. The influence of SDNCF diameter and length on the refractive index sensitivity of the sensor has been investigated by both simulations and experiments, where results show that the diameter of SDNCF has significant influence. However, SDNCF length has limited influence on the sensitivity. Experimental results show that a sensitivity of 327 nm/RIU (refractive index unit) has been achieved for refractive indices ranging from 1.33 to 1.38, which agrees well with the simulated results with a sensitivity of 349.5 nm/RIU at refractive indices ranging from 1.33 to 1.38.

5.
Materials (Basel) ; 16(23)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38068159

RESUMO

Aerosol particle contamination in high-power laser facilities has become a major cause of internal optical component damage resistance and service life reduction. In general, contaminating particles primarily originate from stray light; therefore, it is crucial to investigate the mechanism and dynamics of the dynamic contaminating particle generation to control the cleanliness level. In this study, corresponding research was conducted on experiments and theory. We investigated the particle generation and surface composition modification under the action of a laser. We employed various surface analytical methods to identify the possible variations in the aluminum alloy surface during laser irradiations. A theoretical model for particle ejection from aluminum alloy surfaces was established by taking the adhesion force and laser cleaning force (due to thermal expansion) into account. The results show that the threshold energies for contamination particle generation and damage are around 0.1 and 0.2 J/cm2, respectively. Subsurface impurities are the primary source of particles, and particle adhesion density is related to surface roughness. Pollution particle generation and splashing processes include temperature increases, phase changes, impact diffusion, and adhesion. The results provide a reference for the normal operation of high-energy laser systems. The results also suggest that the laser irradiation pretreatment of aluminum alloy surfaces is essential to improve the cleanliness level.

6.
Genome Announc ; 6(18)2018 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-29724853

RESUMO

The incidence of scarlet fever cases remains high in China. Here, we report the complete genome sequence of a Streptococcus pyogenes isolate of serotype M12, which has been confirmed as the predominant serotype in recent outbreaks. Genome sequencing was achieved by a combination of Oxford Nanopore MinION and Illumina methodologies.

7.
Sci Rep ; 8(1): 11803, 2018 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-30087392

RESUMO

A polarization-dependent all-fiber comb filter based on a combination effect of multimode interference and Mach-Zehnder interferometer was proposed and demonstrated. The comb filter was composed with a short section of multimode fiber (MMF) fusion spliced with a conventional single mode fiber on the one side and a short section of a different type of optical fiber on the other side. The second type of optical fiber is spliced to the MMF with a properly designed misalignment. Different types and lengths of fibers were used to investigate the influence of fiber types and lengths on the performance of the comb filter. Experimentally, several comb filters with free spectral range (FSR) values ranging from 0.236 to 1.524 nm were achieved. The extinction ratio of the comb filter can be adjusted from 6 to 11.1 dB by varying polarization states of the input light, while maintaining the FSR unchanged. The proposed comb filter has the potential to be used in optical dense wavelength division multiplexing communication systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA