Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Radiology ; 266(2): 636-48, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23143027

RESUMO

PURPOSE: To investigate whether C-arm dual-phase cone-beam computed tomography (CT) performed during transcatheter arterial chemoembolization (TACE) with doxorubicin-eluting beads can help predict tumor response at 1-month follow-up in patients with hepatocellular carcinoma (HCC). MATERIALS AND METHODS: This prospective study was compliant with HIPAA and approved by the institutional review board and animal care and use committee. Analysis was performed retrospectively on 50 targeted HCC lesions in 29 patients (16 men, 13 women; mean age, 61.9 years ± 10.7) treated with TACE with drug-eluting beads. Magnetic resonance (MR) imaging was performed at baseline and 1 month after TACE. Dual-phase cone-beam CT was performed before and after TACE. Tumor enhancement at dual-phase cone-beam CT in early arterial and delayed venous phases was assessed retrospectively with blinding to MR findings. Tumor response at MR imaging was assessed according to European Association for the Study of the Liver (EASL) guidelines. Two patients were excluded from analysis because dual-phase cone-beam CT scans were not interpretable. Logistic regression models for correlated data were used to compare changes in tumor enhancement between modalities. The radiation dose with dual-phase cone-beam CT was measured in one pig. RESULTS: At 1-month MR imaging follow-up, complete and/or partial tumor response was seen in 74% and 76% of lesions in the arterial and venous phases, respectively. Paired t tests used to compare images obtained before and after TACE showed a significant reduction in tumor enhancement with both modalities (P < .0001). The decrease in tumor enhancement seen with dual-phase cone-beam CT after TACE showed a linear correlation with MR findings. Estimated correlation coefficients were excellent for first (R = 0.89) and second (R = 0.82) phases. A significant relationship between tumor enhancement at cone-beam CT after TACE and complete and/or partial tumor response at MR imaging was found for arterial (odds ratio, 0.95; 95% confidence interval [CI]: 0.91, 0.99; P = .023) and venous (odds ratio, 0.96; 95% CI: 0.93, 0.99; P = .035) phases with the multivariate logistic regression model. Radiation dose for two dual-phase cone-beam CT scans was 3.08 mSv. CONCLUSION: Intraprocedural C-arm dual-phase cone-beam CT can be used immediately after TACE with doxorubicin-eluting beads to predict HCC tumor response at 1-month MR imaging follow-up.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Doxorrubicina/administração & dosagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Animais , Área Sob a Curva , Feminino , Humanos , Análise dos Mínimos Quadrados , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Doses de Radiação , Suínos , Resultado do Tratamento
2.
Minim Invasive Ther Allied Technol ; 22(5): 297-303, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23837536

RESUMO

INTRODUCTION: C-Arm CT (CACT) is a new imaging modality in liver oncology therapy that allows for the acquisition of 3D images intra-procedurally. CACT has been used to enhance intra-arterial therapies for the liver by improving lesion detection, avoiding non-target embolization, and allowing for more selective delivery of agents. However, one of the limitations of this technology is image artifacts created by respiratory motion. PURPOSE: To determine in this preliminary study improvements in image acquisition, motion compensation, and high resolution 3D reconstruction that can improve CACT image quality (IQ). MATERIAL AND METHODS: Three adult male New Zealand white rabbits were used for this study. First, a control rabbit was used to select the best x-ray acquisition imaging protocol and then two rabbits were implanted with liver tumor to further develop 3D image reconstruction and motion compensation algorithms. RESULTS: The best IQ was obtained using the low 80 kVp protocol with motion compensated reconstruction with high resolution and fast acquisition speed (60 fps, 5 s/scan, and 312 images). CONCLUSION: IQ improved by: (1) decreasing acquisition time, (2) applying motion-compensated reconstruction, and (3) high resolution 3D reconstruction. The findings of this study can be applied to future animal studies and eventually could be translated into the clinical environment.


Assuntos
Imageamento Tridimensional/métodos , Neoplasias Hepáticas Experimentais/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Neoplasias Hepáticas Experimentais/patologia , Masculino , Movimento (Física) , Coelhos , Fatores de Tempo
3.
J Vasc Interv Radiol ; 23(6): 737-43, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22494658

RESUMO

PURPOSE: To describe a novel technique for multimodality positron emission tomography (PET) fusion-guided interventions that combines cone-beam computed tomography (CT) with PET/CT before the procedure. MATERIALS AND METHODS: Subjects were selected among patients scheduled for a biopsy or ablation procedure. The lesions were not visible with conventional imaging methods or did not have uniform uptake on PET. Clinical success was defined by adequate histopathologic specimens for molecular profiling or diagnosis and by lack of enhancement on follow-up imaging for ablation procedures. Time to target (time elapsed between the completion of the initial cone-beam CT scan and first tissue sample or treatment), total procedure time (time from the moment the patient was on the table until the patient was off the table), and number of times the needle was repositioned were recorded. RESULTS: Seven patients underwent eight procedures (two ablations and six biopsies). Registration and procedures were completed successfully in all cases. Clinical success was achieved in all biopsy procedures and in one of the two ablation procedures. The needle was repositioned once in one biopsy procedure only. On average, the time to target was 38 minutes (range 13-54 min). Total procedure time was 95 minutes (range 51-240 min, which includes composite ablation). On average, fluoroscopy time was 2.5 minutes (range 1.3-6.2 min). CONCLUSIONS: An integrated cone-beam CT software platform can enable PET-guided biopsies and ablation procedures without the need for additional specialized hardware.


Assuntos
Biópsia por Agulha/métodos , Ablação por Cateter/métodos , Tomografia Computadorizada de Feixe Cônico , Imagem Multimodal , Neoplasias/diagnóstico , Neoplasias/cirurgia , Tomografia por Emissão de Pósitrons , Radiografia Intervencionista , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/diagnóstico por imagem , Neoplasias/patologia , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Fatores de Tempo , Adulto Jovem
4.
Minim Invasive Ther Allied Technol ; 20(5): 276-81, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21082901

RESUMO

C-arm cone-beam computed tomography (CBCT) can be used to visualize tumor-feeding vessels and parenchymal staining during transcatheter arterial chemoembolization (TACE). To capture these two phases, all current commercially available CBCT systems necessitate two separate contrast-enhanced scans. In this feasibility study, we report initial results of novel software that enhanced our current CBCT system to capture these two phases using only one contrast injection. Novelty of this work is the addition of software that enabled the acquisition of two sequential, back-to-back CBCT scans (dual-phase CBCT, DPCBCT) so both tumor feeding vessels and parenchyma are captured using only one contrast injection. To illustrate our initial experience, DPCBCT was used for TACE treatments involving lipiodol, drug-eluting beads, and Yttrium-90 radioembolizing microspheres. For each case, the DPCBCT images were compared to pre-intervention contrast-enhanced MR/CT. DPCBCT is feasible for TACE treatments and the preliminary results show positive correlation with pre-intervention conventional CT and MR. In addition, the degree of embolization can be monitored. DPCBCT is a promising technology that provides comprehensive visualization of tumor-feeding vessels and parenchymal staining using a single injection of contrast. DPCBCT could potentially be used during TACE to verify catheter position and monitor the embolization effect.


Assuntos
Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Hepáticas/terapia , Idoso , Animais , Meios de Contraste/administração & dosagem , Óleo Etiodado/administração & dosagem , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Neoplasias Hepáticas/irrigação sanguínea , Masculino , Microesferas , Pessoa de Meia-Idade , Suínos , Radioisótopos de Ítrio/administração & dosagem
5.
Med Image Anal ; 10(2): 113-24, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16099196

RESUMO

Minimally invasive interventions are often performed under fluoroscopic guidance. Drawbacks of fluoroscopic guidance are the fact that the presented images are 2D projections and that both the patient and the clinician are exposed to radiation. Image-guided navigation using pre-interventionally acquired 3D MR or CT data is an alternative. However, this often requires invasive anatomical landmark-based, marker-based or surface-based image-to-patient registration. In this paper, a coupling between an image-guided navigation system and an intraoperative C-arm X-ray device with 3D imaging capabilities (3D rotational X-ray (3DRX) system) that enables direct navigation without invasive image-to-patient registration on 3DRX volumes, is described and evaluated. The coupling is established in a one-time preoperative calibration procedure. The individual steps in the registration procedure are explained and evaluated. The acquired navigation accuracy using this coupling is approximately one millimeter.


Assuntos
Algoritmos , Imageamento Tridimensional/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Rotação , Sensibilidade e Especificidade , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
6.
Phys Med Biol ; 50(24): 5769-81, 2005 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-16333154

RESUMO

Recently, three-dimensional (3D) rotational x-ray imaging has been combined with navigation technology, enabling direct 3D navigation for minimally invasive image guided interventions. In this study, phantom experiments are used to determine the accuracy of such a navigation set-up for a mobile C-arm with propeller motion. After calibration of the C-arm system, the accuracy is evaluated by pinpointing divots on a special-purpose phantom with known geometry. This evaluation is performed both with and without C-arm motion in between calibration and registration for navigation. The variation caused by each of the individual transformations in the calibration and registration process is also studied. The feasibility of direct navigation on 3D rotational x-ray images for functional endoscopic sinus surgery has been evaluated in a cadaver navigation experiment. Navigation accuracy was approximately 1.0 mm, which is sufficient for functional endoscopic sinus surgery. C-arm motion in between calibration and registration slightly degraded the registration accuracy by approximately 0.3 mm. Standard deviations of each of the transformations were in the range 0.15-0.31 mm. In the cadaver experiment, the navigation images were considered in good correspondence with the endoscopic images by an experienced ENT surgeon. Availability of 3D localization information provided by the navigation system was considered valuable by the ENT surgeon.


Assuntos
Algoritmos , Cabeça/cirurgia , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imagens de Fantasmas , Cirurgia Assistida por Computador , Cadáver , Endoscopia , Humanos , Tomografia Computadorizada por Raios X
7.
J Vis Exp ; (82): 50795, 2013 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-24326874

RESUMO

The advent of cone-beam computed tomography (CBCT) in the angiography suite has been revolutionary in interventional radiology. CBCT offers 3 dimensional (3D) diagnostic imaging in the interventional suite and can enhance minimally-invasive therapy beyond the limitations of 2D angiography alone. The role of CBCT has been recognized in transarterial chemo-embolization (TACE) treatment of hepatocellular carcinoma (HCC). The recent introduction of a CBCT technique: dual-phase CBCT (DP-CBCT) improves intra-arterial HCC treatment with drug-eluting beads (DEB-TACE). DP-CBCT can be used to localize liver tumors with the diagnostic accuracy of multi-phasic multidetector computed tomography (M-MDCT) and contrast enhanced magnetic resonance imaging (CE-MRI) (See the tumor), to guide intra-arterially guidewire and microcatheter to the desired location for selective therapy (Reach the tumor), and to evaluate treatment success during the procedure (Treat the tumor). The purpose of this manuscript is to illustrate how DP-CBCT is used in DEB-TACE to see, reach, and treat HCC.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Angiografia/instrumentação , Angiografia/métodos , Carcinoma Hepatocelular/irrigação sanguínea , Tomografia Computadorizada de Feixe Cônico/métodos , Doxorrubicina/administração & dosagem , Fluoroscopia/métodos , Artéria Hepática/fisiologia , Humanos , Neoplasias Hepáticas/irrigação sanguínea , Masculino , Pessoa de Meia-Idade
8.
Bone ; 50(1): 200-8, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22057082

RESUMO

The importance of assessing trabecular architecture together with bone mineral density to determine bone stiffness and fracture risk in osteoporosis has been well established. However, no imaging modalities are available to assess trabecular architecture at clinically relevant sites in the axial skeleton. Recently developed flat-panel CT devices, however, offer resolutions that are potentially good enough to resolve bone architecture at these sites. The goal of the present study was to investigate how accurate trabecular architecture and stiffness can be determined based on images from such a device (XperCT, Philips Healthcare). Ten cadaver human C3 vertebrae, twelve T12 vertebrae and 12 proximal femora were scanned with XperCT while mimicking in-vivo scanning conditions and compared to scans of the same bones with microCT. Standard segmentation and morphology quantification algorithms were applied as well as finite element (FE) simulation based on segmented and gray value images. Results showed that mean trabecular separation (Tb.Sp) and number (Tb.N) can be accurately determined at all sites. The accuracy of other parameters, however, depended on the site. For T12 no other structural parameters could be accurately quantified and no FE-results could be obtained from segmented images. When using gray-level images, however, accurate determination of cancellous bone stiffness was possible. For the C3 vertebrae and proximal femora, mean bone volume fraction (BV/TV), Tb.Sp, Tb.N, and anisotropy (C3 only) could be determined accurately. For Tb.Th, structure model index (SMI, femur only), and anisotropy good correlations were obtained but the values were not determined accurately. FE simulations based on segmented images were accurate for the C3 vertebrae, but severely underestimated bone stiffness for the femur. Here also, this was improved by using the gray value models. In conclusion, XperCT does provide a resolution that is good enough to determine trabecular architecture, but the signal to noise ratio is key to the accuracy of the morphology measurement. When the trabeculae are thick e.g. in the femur or the noise is low, e.g. cervical spine, architecture and stiffness could be determined accurately, but when the trabeculae are thin and the noise is high, e.g. thoracic spine, architecture could not be determined accurately and the connectivity was lost and hence no mechanical properties could be calculated directly.


Assuntos
Vértebras Cervicais/anatomia & histologia , Fêmur/anatomia & histologia , Vértebras Torácicas/anatomia & histologia , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Cadáver , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Razão Sinal-Ruído
9.
Cardiovasc Intervent Radiol ; 35(1): 97-104, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21328023

RESUMO

PURPOSE: To evaluate the sensitivity of dual-phase cone-beam computed tomography during hepatic arteriography (CBCTHA) for the detection of hepatocellular carcinoma (HCC) by comparing it with the diagnostic imaging "gold standard": contrast-enhanced magnetic resonance imaging (CE-MRI) of the liver. MATERIALS AND METHODS: Eighty-eight HCC lesions (mean diameter 3.9 ± 3.3 cm) in 20 patients (13 men, mean age 61.4 years [range 50 to 80]), who sequentially underwent baseline diagnostic liver CE-MRI and then underwent early arterial- and delayed portal venous-phase CBCTHA during drug eluting-bead transarterial chemoembolization, were evaluated. Dual-phase CBCTHA findings of each tumor in terms of conspicuity were compared with standard CE-MR images and classified into three grades: optimal, suboptimal, and nondiagnostic. RESULTS: Seventy-seven (mean diameter 4.2 ± 3.4 cm [range 0.9 to 15.9]) (93.9%) of 82 tumors were detected. Sensitivity of arterial-phase (71.9%) was lower than that of venous-phase CBCTHA (86.6%) for the detection of HCC lesions. Of the 82 tumors, 33 (40.2%) and 52 (63.4%), 26 (31.7%) and 19 (23.2%), and 23 (28%) and 11 (13.4%) nodules were classed as optimal, suboptimal, and nondiagnostic on arterial- and venous-phase CBCTHA images, respectively. Seventeen (73.9%) of the 23 tumors that were not visible on arterial phase were detected on venous phase. Six (54.5%) of the 11 tumors that were not visible on venous phase were detected on arterial phase. CONCLUSIONS: Dual-phase CBCTHA has sufficient image quality to detect the majority of HCC lesions compared with the imaging "gold standard": CE-MRI of the liver. Moreover, dual-phase CBCTHA is more useful and reliable than single-phasic imaging to depict HCC nodules.


Assuntos
Angiografia/métodos , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/terapia , Imageamento por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
10.
Int J Cardiovasc Imaging ; 27(8): 1205-22, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21394614

RESUMO

Imaging modalities utilized in the interventional cardiology suite have seen an impressive evolution and expansion recently, particularly with regard to the recent interest in three-dimensional (3D) imaging. Despite this, the backbone of visualization in the catheterization laboratory remains two-dimensional (2D) X-ray fluoroscopy and cine-angiography. New imaging techniques under development, referred to as three-dimensional rotational angiography (RA) and C-arm CT, hold great promise for improving current device implantation and understanding of cardiovascular anatomy. This paper reviews the evolution of rotational angiography and advanced 3D X-ray imaging applications to interventional cardiology.


Assuntos
Cateterismo Cardíaco , Angiografia Coronária/métodos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/métodos , Imageamento Tridimensional , Tomografia Computadorizada por Raios X , Humanos , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Resultado do Tratamento
11.
IEEE Trans Med Imaging ; 29(2): 260-72, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20129843

RESUMO

Since the introduction of 3-D rotational X-ray imaging, protocols for 3-D rotational coronary artery imaging have become widely available in routine clinical practice. Intra-procedural cardiac imaging in a computed tomography (CT)-like fashion has been particularly compelling due to the reduction of clinical overhead and ability to characterize anatomy at the time of intervention. We previously introduced a clinically feasible approach for imaging the left atrium and pulmonary veins (LAPVs) with short contrast bolus injections and scan times of approximately 4 -10 s. The resulting data have sufficient image quality for intra-procedural use during electro-anatomic mapping (EAM) and interventional guidance in atrial fibrillation (AF) ablation procedures. In this paper, we present a novel technique to intra-procedural surface generation which integrates fully-automated segmentation of the LAPVs for guidance in AF ablation interventions. Contrast-enhanced rotational X-ray angiography (3-D RA) acquisitions in combination with filtered-back-projection-based reconstruction allows for volumetric interrogation of LAPV anatomy in near-real-time. An automatic model-based segmentation algorithm allows for fast and accurate LAPV mesh generation despite the challenges posed by image quality; relative to pre-procedural cardiac CT/MR, 3-D RA images suffer from more artifacts and reduced signal-to-noise. We validate our integrated method by comparing 1) automatic and manual segmentations of intra-procedural 3-D RA data, 2) automatic segmentations of intra-procedural 3-D RA and pre-procedural CT/MR data, and 3) intra-procedural EAM point cloud data with automatic segmentations of 3-D RA and CT/MR data. Our validation results for automatically segmented intra-procedural 3-D RA data show average segmentation errors of 1) approximately 1.3 mm compared with manual 3-D RA segmentations 2) approximately 2.3 mm compared with automatic segmentation of pre-procedural CT/MR data and 3) approximately 2.1 mm compared with registered intra-procedural EAM point clouds. The overall experiments indicate that LAPV surfaces can be automatically segmented intra-procedurally from 3-D RA data with comparable quality relative to meshes derived from pre-procedural CT/MR.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Angiografia Coronária/métodos , Processamento de Imagem Assistida por Computador/métodos , Intensificação de Imagem Radiográfica/métodos , Radiografia Intervencionista/métodos , Átrios do Coração/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Veias Pulmonares/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA