Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Heart Rhythm O2 ; 1(2): 103-110, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34113864

RESUMO

BACKGROUND: The quality of catheter-tissue contact is one of the most important determinants of catheter ablation (CA) success. The absence of catheter-tissue contact feedback has been regarded a major limitation of remote magnetic navigation (RMN)-guided CA. The e-Contact module (ECM) is a novel feature designed for RMN that measures the quality of catheter-tissue contact. OBJECTIVE: The purpose of this study was to describe the first clinical experience with this feature and to test its effect on procedural parameters and interference with other ablation equipment during CA procedures as well as its safety. METHODS: This was a prospective, single-center, 2-phase study investigating ECM use during complex RMN procedures in 30 patients. Impact of ECM on procedural parameters was evaluated in the feasibility phase (FP), and its interference with other equipment was tested in the interference phase (IP) using pacing maneuvers at 3 randomly selected right atrial sites. Intracardiac electrograms were evaluated for disturbances by 2 independent electrophysiologists. RESULTS: For FP, mean procedural time was 162 ± 66 minutes, fluoroscopy time 21 ± 9 minutes, and ablation time 34 ± 21 minutes. For IP, no significant differences in pacing capture or thresholds were found (ECM- vs ECM+: site 1: 2.05 vs 2.21 mA; P = .320; site 2: 2.15 vs 2.12 mA; P = .873; site 3: 2.51 vs 2.50 mA; P = .976). Electrogram disturbances did not significantly differ between ECM- and ECM+. No adverse events were reported. CONCLUSION: The ECM is a novel catheter-tissue contact technology designed for RMN-guided CA. Our study suggests that this feature is feasible and does not interfere with other electrophysiology equipment while maintaining an excellent safety profile.

2.
Int J Cardiol ; 315: 36-44, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32413467

RESUMO

INTRODUCTION: Remote magnetic navigation (RMN)-guided catheter ablation (CA) is a feasible treatment option for patients presenting with ischemic ventricular tachycardia (VT). Catheter-tissue contact feedback, enhances lesion formation and may consequently improve CA outcomes. Until recently, contact feedback was unavailable for RMN-guided CA. The novel e-Contact Module (ECM) was developed to continuously monitor and ensure catheter-tissue contact during RMN-guided CA. OBJECTIVE: The present study aims to evaluate the effect of ECM implementation on acute and long-term outcomes in RMN-guided ischemic VT ablation. METHOD: This retrospective, two-center study included consecutive ischemic VT patients undergoing RMN-guided CA from 2010 to 2017. Baseline clinical data, procedural data, including radiation times, and acute success rates were compared between CA procedures performed with ECM (ECM+) and without ECM (ECM-). One-year VT-free survival was analyzed using Cox-proportional hazards models, adjusting for potential confounders: age, left ventricular function, VT inducibility at baseline and substrate based ablation strategy. RESULTS: The current study included 145 patients (ECM+ N = 25, ECM- N = 120). Significantly lower fluoroscopy times were observed in the ECM+ group (9.5 (IQR 5.3-13.5) versus 12.5 min (IQR 8.0-18.0), P = 0.025). Non-inducibility of the clinical VT at the end of procedure was observed in 92% ECM+ versus 72% ECM- patients (P = 0.19). ECM guidance was associated with significantly lower VT-recurrence rates during 1-year follow-up (16% ECM+ versus 40% ECM-; multivariable HR 0.29, 95%-CI 0.10-0.69, P = 0.021, reference group: ECM-). CONCLUSION: Contact feedback by the ECM further decreases fluoroscopy exposure and improves VT-free survival in RMN-guided ischemic VT ablation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Retroalimentação , Humanos , Fenômenos Magnéticos , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
3.
Clin Case Rep ; 7(7): 1391-1394, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31360495

RESUMO

We present a unique case of a left-sided phrenic nerve injury (PNI) long after a previous contralateral PNI following pulmonary vein isolation (PVI) procedures. Firstly, right-sided PNI after cryoballoon ablation, and secondly a left-sided PNI was observed following a redo PVI extended with box-lesion and left atrial appendage isolation (LAAI).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA