Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 15(7): 951-6, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23419657

RESUMO

AIMS: Pulmonary vein isolation (PVI) by catheter ablation for atrial fibrillation (AF) requires suppression of patient restlessness by sufficient sedation in addition to maintaining stable respiration. We applied adaptive-servo ventilation (ASV) and examined the effects of ASV combined with deep propofol sedation on PVI using a NavX. METHODS AND RESULTS: We analysed 75 paroxysmal AF (PAF) patients (62 ± 11 years; 53 men and 22 women) who underwent PVI for treatment of PAF using an ASV system combined with deep sedation (ASV group). Control patients included 75 consecutive PAF patients (62 ± 11 years; 51 men and 24 women) who underwent PVI just before introduction of the ASV system. Deep sedation was defined as a Ramsay sedation score of 6. The ASV group had a lower frequency of restless body movements compared with the control group during PVI (1.5 ± 0.7 vs. 7.8 ± 1.4 times, P < 0.01). The frequency of respiratory compensation and EnGuide alignment of catheter position by the NavX was lower in the ASV (4.2 ± 3.3 and 8.8 ± 7.1 times) than control group (7.1 ± 5.1 and 15.2 ± 10.0 times, P < 0.05 and <0.01, respectively). Consequently, significantly lower total electrical energy supply (48.7 ± 6.0 KJ) was required in the ASV than control group (64.5 ± 24.9 KJ, P < 0.01). Further, significantly shorter fluoroscopy and procedural times were observed in the ASV (28 ± 5 and 109 ± 25 min) than the control group (33 ± 6 and 141 ± 38 min, respectively, P < 0.01) and the AF recurrence rate was significantly lower in the ASV than the control group (12 vs. 25%, P < 0.01). CONCLUSION: ASV combined with deep sedation is an effective strategy during PVI using the NavX in patients with PAF.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Sedação Profunda , Hipnóticos e Sedativos , Suporte Ventilatório Interativo , Propofol , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Sedação Profunda/efeitos adversos , Feminino , Humanos , Hipnóticos e Sedativos/efeitos adversos , Suporte Ventilatório Interativo/efeitos adversos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Propofol/efeitos adversos , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA