1.
Sensors (Basel) ; 23(17)2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37687777

RESUMO

The objective of this work was to develop a temperature sensor system that accurately measures core body temperature from an ear-worn device. Two digital temperature sensors were embedded in a hearing aid shell along the thermal gradient of the ear canal to form a linear heat balance relationship. This relationship was used to determine best fit parameters for estimating body temperature. The predicted body temperatures resulted in intersubject limits of agreement (LOA) of ±0.49 °C over a range of physiologic and ambient temperatures without calibration. The newly developed hearing aid-based temperature sensor system can estimate core body temperature at an accuracy level equal to or better than many devices currently on the market. An accurate, continuously worn, temperature monitoring and tracking device may help provide early detection of illnesses, which could prove especially beneficial during pandemics and in the elderly demographic of hearing aid wearers.


Assuntos
Temperatura Corporal , Meato Acústico Externo , Humanos , Idoso , Temperatura , Calibragem , Primeiros Socorros
2.
Sci Rep ; 10(1): 9249, 2020 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-32514058

RESUMO

Carotid bodies (CBs) are chemoreceptors that monitor and register changes in the blood, including the levels of oxygen, carbon dioxide, and pH, and regulate breathing. Enhanced activity of CBs was shown to correlate with a significant elevation in the blood pressure of patients with hypertension. CB removal or denervation were previously shown to reduce hypertension. Here we demonstrate the feasibility of a dual-mode ultrasound array (DMUA) system to safely ablate the CB in vivo in a spontaneously hypertensive rat (SHR) model of hypertension. DMUA imaging was used for guiding and monitoring focused ultrasound (FUS) energy delivered to the target region. In particular, 3D imaging was used to identify the carotid bifurcation for targeting the CBs. Intermittent, high frame rate imaging during image-guided FUS (IgFUS) delivery was used for monitoring the lesion formation. DMUA imaging provided feedback for closed-loop control (CLC) of the lesion formation process to avoid overexposure. The procedure was tolerated well in over 100 SHR and normotensive rats that received unilateral and bilateral treatments. The measured mean arterial pressure (MAP) exhibited measurable deviation from baseline 2-4 weeks post IgFUS treatment. The results suggest that the direct unilateral FUS treatment of the CB might be sufficient to reduce the blood pressure in hypertensive rats and justify further investigation in large animals and eventually in human patients.


Assuntos
Corpo Carotídeo/cirurgia , Ablação por Ultrassom Focalizado de Alta Intensidade/instrumentação , Hipertensão/cirurgia , Cirurgia Assistida por Computador/instrumentação , Animais , Corpo Carotídeo/patologia , Hipertensão/diagnóstico por imagem , Hipertensão/patologia , Masculino , Ratos , Ratos Endogâmicos SHR , Sinais Vitais
3.
Brain Stimul ; 12(6): 1439-1447, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31377096

RESUMO

BACKGROUND: Transcranial focused ultrasound (tFUS) at low intensities has been reported to directly evoke responses and reversibly inhibit function in the central nervous system. While some doubt has been cast on the ability of ultrasound to directly evoke neuronal responses, spatially-restricted transcranial ultrasound has demonstrated consistent, inhibitory effects, but the underlying mechanism of reversible suppression in the central nervous system is not well understood. OBJECTIVE/HYPOTHESIS: In this study, we sought to characterize the effect of transcranial, low-intensity, focused ultrasound on the thalamus during somatosensory evoked potentials (SSEP) and investigate the mechanism by modulating the parameters of ultrasound. METHODS: TFUS was applied to the ventral posterolateral nucleus of the thalamus of a rodent while electrically stimulating the tibial nerve to induce an SSEP. Thermal changes were also induced through an optical fiber that was image-guided to the same target. RESULTS: Focused ultrasound reversibly suppressed SSEPs in a spatially and intensity-dependent manner while remaining independent of duty cycle, peak pressure, or modulation frequency. Suppression was highly correlated and temporally consistent with in vivo temperature changes while producing no pathological changes on histology. Furthermore, stereotactically-guided delivery of thermal energy through an optical fiber produced similar thermal effects and suppression. CONCLUSION: We confirm that tFUS predominantly causes neuroinhibition and conclude that the most primary biophysical mechanism is the thermal effect of focused ultrasound.


Assuntos
Potenciais Somatossensoriais Evocados/fisiologia , Inibição Neural/fisiologia , Tálamo/diagnóstico por imagem , Tálamo/fisiologia , Termografia/métodos , Terapia por Ultrassom/métodos , Animais , Neurônios/fisiologia , Ratos , Ratos Sprague-Dawley , Ultrassonografia/métodos