Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Curr Cardiol Rep ; 21(10): 129, 2019 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-31520150

RESUMO

PURPOSE OF REVIEW: The goal was to evaluate published data on the incidence, diagnosis, and management of symptomatic combined mitral and aortic valvular disease. Furthermore, to identify the role of treatment using contemporary transcatheter techniques. RECENT FINDINGS: Up to a quarter of symptomatic adult valvular disease is caused by multiple left-sided valvular lesions. The etiologic spectrum of this combined disease has shifted from rheumatic to degenerative. Both presentation and diagnosis of lesions are modified compared with isolated disease. Based upon narrative review, there are only limited observational experiences, insufficient to provide robust guidance. These data, however, indicate the feasibility of interventions such as transcatheter aortic valve replacement and edge-to-edge mitral valve repair to treat such disease and mitigate the risks of open surgery. Combined aortic and mitral valve disease is commonly encountered. There is a role for transcatheter interventions based on limited data; however, more research is needed.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Adulto , Valva Aórtica , Humanos , Valva Mitral , Insuficiência da Valva Mitral/cirurgia
2.
Eur Heart J ; 35(37): 2530-40, 2014 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-24682843

RESUMO

AIM: The aim of this study was to evaluate whether coronary artery disease (CAD) severity exerts a gradient of risk in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: A total of 445 patients with severe AS undergoing TAVI were included into a prospective registry between 2007 and 2012. The preoperative SYNTAX score (SS) was determined from baseline coronary angiograms. In case of revascularization prior to TAVI, residual SS (rSS) was also determined. Clinical outcomes were compared between patients without CAD (n = 158), patients with low SS (0-22, n = 207), and patients with high SS (SS > 22, n = 80). The pre-specified primary endpoint was the composite of cardiovascular death, stroke, or myocardial infarction (MI). At 1 year, CAD severity was associated with higher rates of the primary endpoint (no CAD: 12.5%, low SS: 16.1%, high SS: 29.6%; P = 0.016). This was driven by differences in cardiovascular mortality (no CAD: 8.6%, low SS: 13.6%, high SS: 20.4%; P = 0.029), whereas the risk of stroke (no CAD: 5.1%, low SS: 3.3%, high SS: 6.7%; P = 0.79) and MI (no CAD: 1.5%, low SS: 1.1%, high SS: 4.0%; P = 0.54) was similar across the three groups. Patients with high SS received less complete revascularization as indicated by a higher rSS (21.2 ± 12.0 vs. 4.0 ± 4.4, P < 0.001) compared with patients with low SS. High rSS tertile (> 14) was associated with higher rates of the primary endpoint at 1 year (no CAD:12.5%, low rSS: 16.5%, high rSS: 26.3%, P = 0.043). CONCLUSIONS: Severity of CAD appears to be associated with impaired clinical outcomes at 1 year after TAVI. Patients with SS > 22 receive less complete revascularization and have a higher risk of cardiovascular death, stroke, or MI than patients without CAD or low SS.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/complicações , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/patologia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/patologia , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Infarto do Miocárdio/etiologia , Estudos Prospectivos , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
3.
Eur Heart J ; 34(44): 3437-50, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24096324

RESUMO

AIMS: Our aim was to evaluate the invasive haemodynamic indices of high-risk symptomatic patients presenting with 'paradoxical' low-flow, low-gradient, severe aortic stenosis (AS) (PLF-LG) and low-flow, low-gradient severe AS (LEF-LG) and to compare clinical outcomes following transcatheter aortic valve implantation (TAVI) among these challenging AS subgroups. METHODS AND RESULTS: Of 534 symptomatic patients undergoing TAVI, 385 had a full pre-procedural right and left heart catheterization. A total of 208 patients had high-gradient severe AS [HGAS; mean gradient (MG) ≥40 mmHg], 85 had PLF-LG [MG ≤ 40 mmHg, indexed aortic valve area [iAVA] ≤0.6 cm(2) m(-2), stroke volume index ≤35 mL/m(2), ejection fraction (EF) ≥50%], and 61 had LEF-LG (MG ≤ 40 mmHg, iAVA ≤0.6 cm(2) m(-2), EF ≤40%). Compared with HGAS, PLF-LG and LEF-LG had higher systemic vascular resistances (HGAS: 1912 ± 654 vs. PLF-LG: 2006 ± 586 vs. LEF-LG: 2216 ± 765 dyne s m(-5), P = 0.007) but lower valvulo-arterial impedances (HGAS: 7.8 ± 2.7 vs. PLF-LG: 6.9 ± 1.9 vs. LEF-LG: 7.7 ± 2.5 mmHg mL(-1) m(-2), P = 0.027). At 30 days, no differences in cardiac death (6.5 vs. 4.9 vs. 6.6%, P = 0.90) or death (8.4 vs. 6.1 vs. 6.6%, P = 0.88) were observed among HGAS, PLF-LG, and LEF-LG groups, respectively. At 1 year, New York Heart Association functional improvement occurred in most surviving patients (HGAS: 69.2% vs. PLF-LG: 71.7% vs. LEF-LG: 89.3%, P = 0.09) and no significant differences in overall mortality were observed (17.6 vs. 20.5 vs. 24.5%, P = 0.67). Compared with HGAS, LEF-LG had a higher 1 year cardiac mortality (adjusted hazard ratio 2.45, 95% confidence interval 1.04-5.75, P = 0.04). CONCLUSION: TAVI in PLF-LG or LEF-LG patients is associated with overall mortality rates comparable with HGAS patients and all groups profit symptomatically to a similar extent.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Idoso de 80 Anos ou mais , Análise de Variância , Valva Aórtica , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Hipertensão Pulmonar/fisiopatologia , Masculino , Falha de Prótese , Estudos Retrospectivos , Volume Sistólico/fisiologia , Resultado do Tratamento , Disfunção Ventricular Esquerda
4.
Eur Heart J ; 34(25): 1894-905, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23487519

RESUMO

AIMS: Transcatheter aortic valve implantation (TAVI) is an established treatment alternative to surgical aortic valve replacement in high-risk and inoperable patients and outcomes among patients with estimated low or intermediate risk remain to be determined. The aim of this study was to assess clinical outcomes among patients with estimated low or intermediate surgical risk undergoing TAVI. METHODS AND RESULTS: Between August 2007 and October 2011, 389 consecutive patients underwent TAVI and were categorized according to the Society of Thoracic Surgeons (STS) score into low (STS < 3%; n = 41, 10.5%), intermediate (STS ≥3% and ≤8%, n = 254, 65.3%), and high-risk (STS > 8%; n = 94, 24.2%) groups for the purpose of this study. Significant differences were found between the groups (low risk vs. intermediate risk vs. high risk) for age (78.2 ± 6.7 vs. 82.7 ± 5.7 vs. 83.7 ± 4.9, P < 0.001), body mass index (28.1 ± 6.1 vs. 26.5 ± 4.9 vs. 24.4 ± 4.6, P < 0.001), chronic renal failure (34 vs. 67 vs. 90%, P < 0.001), all-cause mortality at 30 days (2.4 vs. 3.9 vs. 14.9%, P = 0.001), and all-cause mortality at 1 year (10.1 vs. 16.1 vs. 34.5%, P = 0.0003). No differences were observed with regards to cerebrovascular accidents and myocardial infarction during 1-year follow-up. CONCLUSION: In contemporary practice, TAVI is not limited to inoperable or STS-defined high-risk patients and should be guided by the decision of an interdisciplinary Heart Team. Compared with patients at calculated high risk, well-selected patients with STS-defined intermediate or low risk appear to have favourable clinical outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/mortalidade , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
5.
Eur Heart J Case Rep ; 8(1): ytad635, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38223510

RESUMO

Background: Primary cardiac lymphoma (PCL) is rare and its presentation can be variable. Thorough workup of suspected PCL or other cardiac tumours typically incorporates a range of imaging techniques and laboratory investigations but ultimately diagnosis is confirmed by histological analysis of myocardial tissue. Case Summary: An 80-year-old Caucasian female presented with complete heart block and symptomatic cardiac tamponade. A pericardiocentesis was performed and a dual-chamber permanent pacemaker was implanted for the management of her complete heart block. Subsequently, a right atrial mass was discovered on imaging and the patient underwent endomyocardial biopsy of the mass. Histological analysis of the sample confirmed a primary cardiac lymphoma. The patient opted to forgo treatment with chemotherapy and died from her disease 1 month later. Discussion: Cardiac arrhythmias can occur in PCL due to infiltration of conduction pathways. Characterization of cardiac masses on various imaging modalities and laboratory tests guides diagnosis. Tissue diagnosis is required to confirm PCL. The location of a cardiac mass may present technical challenges when undertaking a biopsy, so the best approach to tissue sampling should be considered on an individual basis. Without treatment survival is less than one month but with modern chemoimmunotherapy five-year survival may exceed 50%.

6.
Catheter Cardiovasc Interv ; 82(4): E403-10, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23378279

RESUMO

OBJECTIVES: We sought to evaluate the strategy success and short term clinical outcomes of direct stenting via 5 French (F) diagnostic catheters using a novel bare metal stent with integrated delivery system (IDS) (Svelte Medical Systems, New Providence, NJ) and compare the results to a conventionally treated matched group. METHODS: Fifteen consecutive patients with lesions deemed suitable for direct stenting using a bare metal stent were included. The primary endpoint was the strategy success defined as the ability to successfully treat a target lesion via a 5 F diagnostic catheter with a good angiographic result (TIMI III flow, residual stenosis ≤20%). Procedure and fluoroscopy times, contrast agent use, cost, and short-term clinical outcomes were compared to a matched group treated via conventional stenting. RESULTS: The primary endpoint was reached in 14/15 patients (93%). There were no significant differences in procedural (58.6 min ± 12.7 vs. 57.4 min ± 14.2) or fluoroscopy times (10.0 min ± 4.3 vs.10.1 min ± 3.9) or contrast agent use (193.7 ml ± 54.8 vs. 181.4 ml ± 35.6). However, there were significant reductions in materials used in the study group compared to the control group equating to cost savings of almost US $600 per case (US $212.44 ± 258.09 vs. US $804.69 ± 468.11; P = 0.001). CONCLUSIONS: Direct stenting using a novel bare metal stent with an IDS via 5 F diagnostic catheters is a viable alternative to conventional stenting in selected patients and is associated with significant cost savings.


Assuntos
Cateteres Cardíacos , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Cateteres Cardíacos/economia , Estudos de Casos e Controles , Meios de Contraste , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/economia , Redução de Custos , Análise Custo-Benefício , Desenho de Equipamento , Feminino , Custos de Cuidados de Saúde , Humanos , Masculino , Metais , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/economia , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Radiografia Intervencionista , Stents/economia , Fatores de Tempo , Resultado do Tratamento
9.
Ir J Med Sci ; 192(6): 2707-2712, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37009982

RESUMO

BACKGROUND: Atrial fibrillation is the most common cardiac arrhythmia and is a major risk factor for stroke, with an incidence rate of 4-5% per year. The use of DOACs is recommended for specific patient populations however the risk of bleeding commonly precludes their use. Left atrial appendage occlusion is a relatively novel procedure recommended for such patients. We set out to analyse the initial success and safety of this procedure in a single site. RESULTS: Twenty patients were included in the study with an average age of 81 years. Seventy percent (n = 14) were male. Ninety percent (n = 18) had a history of major bleeding, an absolute contraindication to anticoagulation. The mean CHADS2VaSc and HASBLED scores were 4.75 and 3.7, respectively. The technical success rate was 95% comparable with existing data. The procedural success rate in our study was 80%. The most frequent complication was cardiac tamponade, occurring in 10% of cases. CONCLUSION: We report lower technical success and procedural success rates in an older population cohort than historically studied, 90% of whom had an absolute contraindication to oral anticoagulation, with higher CHADS2VaSc and HASBLED scores than commonly studied.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Apêndice Atrial/cirurgia , Anticoagulantes/uso terapêutico , Resultado do Tratamento , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Hemorragia , Fibrilação Atrial/complicações , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia
10.
JACC Case Rep ; 4(12): 732-733, 2022 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35734525

RESUMO

We describe a patient who presented for elective percutaneous coronary intervention to treat a chronic total occlusion of the right coronary artery. An intramural hematoma resulted from the intervention and was discovered with intravenous ultrasound. The complication was successfully managed conservatively, and follow-up showed patent coronary arteries. (Level of Difficulty: Intermediate.).

11.
Front Cardiovasc Med ; 9: 938653, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36017101

RESUMO

Introduction: Transcatheter aortic valve replacement (TAVR) is a minimally invasive procedure to replace a diseased and faulty aortic valve in patients with severe aortic stenosis. As TAVR gains popularity among lower-risk younger patients with a longer life expectancy; there is a need to investigate the long-term shortcomings and limitations of the procedure for this patient group. One such shortcoming is that commissural alignment of transcatheter heart valves (THV) appears to be random; meaning that the THV neo-commissures can misalign with the native commissures of the aortic valve during deployment or self-expansion. Objectives: Identify techniques and procedures used to obtain commissural alignment in TAVR. Evaluate the effectiveness of these procedures in terms of the degree of commissural alignment. Analyse the impact of commissural alignment on coronary filling and re-access. Methods: Two electronic online databases were searched to identify existing literature relevant to the aim and objectives of this review: EBSCOhost and PubMed. After search filters were applied and duplicates removed; a total of 64 articles from both databases were screened against the inclusion/exclusion criteria. This resulted in a total of thirteen articles which met the objectives of this review and thus; were included. Results: All studies focused on a patient centered approach involving pre-TAVR computed tomography to obtain commissural alignment. Other studies modified this approach and combined techniques. All studies that implemented a technique to reduce commissural misalignment were significantly successful in obtaining commissural alignment when compared to a study in which alignment was random when no technique was implemented. Severe coronary overlapping in commissural aligned heart valves was relatively low compared to severe coronary overlapping when no technique was implemented. Conclusions: An increase in optimal commissural alignment via introduction of an alignment technique may seem attractive; however; the categorization of commissural alignment is arbitrary and does not accurately reflect real life clinical implications. Further research is needed to determine whether a routine procedure to achieve commissural alignment is necessary in low-risk younger patients undergoing TAVR.

12.
JACC Case Rep ; 4(7): 406-410, 2022 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-35693902

RESUMO

We describe the case of an 86-year-old man with an extensive cardiac history, including previous coronary artery bypass grafting, who experienced a delayed extracardiac hematoma, 350 mL in volume, after retrograde chronic total occlusion-percutaneous coronary intervention. The patient was successfully treated with resultant liquefaction of the hematoma. (Level of Difficulty: Advanced.).

14.
Open Heart ; 8(2)2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34642241

RESUMO

BACKGROUND: Small femoral arteries have been associated with a higher risk of vascular complications in transfemoral transcatheter aortic valve replacement (TAVR). We investigated the feasibility and safety of TAVR in patients with small femoral arteries. METHODS: In this observational study, we included 82 patients who underwent transfemoral TAVR with the ACURATE neo system using the expandable 14F iSleeve sheath between 2018 and 2019 at Karolinska University Hospital, Sweden. Of these, 41 patients had a minimal femoral artery diameter of ≥5.5 mm (mean 6.5, range 5.5-9.2), and 41 patients had a minimal femoral artery diameter <5.5 mm (mean 4.9, range 3.9-5.4). RESULTS: There was no significant difference in major vascular and bleeding complications between the small femoral artery group (7%) and the normal femoral artery group (2%) (p=0.62). The total of major and minor vascular complications did not differ significantly according to femoral artery size (17% vs 5%) (p=0.16). The iSleeve sheath was not correlated with any of the complications. The use of the iSleeve sheath was unsuccessful in four patients (5%), of which one patient had a small femoral artery diameter. CONCLUSION: Transfemoral TAVR with the ACURATE neo system using the iSleeve sheath is a promising method for patients with small femoral arteries even though we found a trend towards higher rates of complications in these patients. The use of expandable sheaths may expand the spectrum of patients that can be treated with transfemoral TAVR, and thus may improve the prognosis in patients with severe aortic valve stenosis.


Assuntos
Angiografia/métodos , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Artéria Femoral/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Cateterismo Cardíaco/instrumentação , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Artéria Femoral/cirurgia , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco
16.
Interv Cardiol ; 14(3): 147-151, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31867060

RESUMO

The limited durability of surgical bioprostheses, combined with an ageing population, has led to an increasing demand for replacing degenerated bioprosthetic surgical heart valves, which is projected to increase. Valve-in-valve transcatheter aortic valve implantation involves implanting a transcatheter heart valve within a degenerated bioprosthetic surgical heart valve. A significant minority of patients, however, are left with a suboptimal haemodynamic result with high residual gradients. This is more common with smaller surgical bioprostheses, and may be associated with a worse prognosis. The novel concept of fracturing the previously implanted bioprosthetic surgical heart valve during valve-in-valve transcatheter aortic valve implantation to create a more favourable haemodynamic profile has shown great promise, particularly in smaller valves. Herein, we describe the benefits, limitations and potential complications of this novel approach.

17.
Eur Heart J Acute Cardiovasc Care ; 8(3): 283-290, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30406673

RESUMO

BACKGROUND: Women with ST-segment elevation myocardial infarction (STEMI) experience greater delays for percutaneous coronary intervention-facilitated reperfusion than men. Whether women and men benefit equally from current strategies to reduce ischaemic time and whether there are gender differences in factors determining delays is unclear. METHODS: Patient delay (symptom onset to first medical contact) and system delay (first medical contact to percutaneous coronary intervention-facilitated reperfusion) were compared between women ( n=967) and men ( n=3393) in a Swiss STEMI treatment network. Trends from 2000 to 2016 were analysed, with additional comparisons between three time periods (2000-2005, 2006-2011 and 2012-2016). Factors predicting delays and hospital mortality were determined by multivariate regression modelling. RESULTS: Female gender was independently associated with greater patient delay ( P=0.02 vs. men), accounting for a 12% greater total ischaemic time among women in 2012-2016 (median 215 vs. 192 minutes, P<0.001 vs. men). From 2000-2005 to 2012-2016, median system delay was reduced by 18 and 25 minutes in women and men, respectively ( P<0.0001 for trend, P=n.s. for gender difference). Total occlusion of the culprit artery, stent thrombosis, a Killip class of 3 or greater, and presentation during off-hours predicted delays in men, but not in women. A Killip class of 3 or greater and age, but not gender or delays, were independently associated with hospital mortality. CONCLUSIONS: STEMI-related ischaemic time in women remains greater than in men due to persistently greater patient delays. In contrast to men, clinical signs of ongoing chest discomfort do not predict delays in women, suggesting that female STEMI patients are less likely to attribute symptoms to a condition requiring urgent treatment.


Assuntos
Intervenção Coronária Percutânea , Medição de Risco/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Tempo para o Tratamento/tendências , Idoso , Eletrocardiografia , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Distribuição por Sexo , Fatores Sexuais , Taxa de Sobrevida/tendências , Suíça/epidemiologia , Fatores de Tempo
18.
Circulation ; 116(21): 2391-8, 2007 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-17984377

RESUMO

BACKGROUND: Concern regarding risk of late thrombosis after "off-label" treatment with drug-eluting stents has prompted increased use of bare-metal stents (BMS) in current practice. The sequelae of late BMS failures, however, have been poorly characterized. METHODS AND RESULTS: We performed a retrospective study of 4503 consecutive patients treated with at least 1 BMS and dual antiplatelet therapy between 1994 and 2000. The cumulative incidence of stent thrombosis was 0.5% at 30 days (95% CI, 0.3% to 0.7%), 0.8% at 1 year (95% CI, 0.6% to 1.1%), and 2.0% at 10 years (95% CI, 1.5% to 2.5%). Risk of late (30 days to 1 year) and very late (>1 year) BMS thrombosis was increased among patients considered off label for drug-eluting stent use (P=0.024). When saphenous vein graft interventions were excluded, however, risk after off-label use was not significantly increased (P=0.23). Other correlates included vein graft intervention, prior myocardial infarction (MI), peripheral vascular disease, and ulcerated lesion (P<0.001). Mortality was markedly increased after late and very late BMS thrombosis, particularly during the first 30 days (hazard ratios, 22 [95% CI, 3.1 to 159] and 40 [95% CI, 15 to 107], respectively). The 10-year incidence of clinical restenosis was 18.1% (95% CI, 16.5% to 19.7%), presenting with MI in 2.1% (95% CI, 1.6% to 2.6%). Restenosis presenting with MI was associated with increased mortality compared with no restenosis (hazard ratio, 2.37; P<0.001) and with restenosis with a non-MI presentation (hazard ratio, 2.42; P<0.001). CONCLUSIONS: The incidence of BMS thrombosis and of MI caused by restenosis during extended follow-up is significant. Both complications are associated with mortality.


Assuntos
Reestenose Coronária/epidemiologia , Trombose Coronária/epidemiologia , Metais/efeitos adversos , Stents/efeitos adversos , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/tendências , Estudos de Coortes , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Trombose Coronária/etiologia , Trombose Coronária/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents/tendências , Fatores de Tempo , Resultado do Tratamento
20.
Front Cardiovasc Med ; 5: 63, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29951486

RESUMO

Aim: To assess the accuracy of multi-detector computed tomography (MDCT) derived pulmonary vessel measurements in predicting pulmonary hypertension (PH) among patients with severe symptomatic aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). Background: PH is common among patients with severe AS undergoing TAVI and is associated with adverse outcomes. MDCT is the imaging modality of choice to assess anatomical dimensions among patients selected for TAVI. Methods: One hundred and thirty-nine patients with severe AS undergoing TAVI with both CT scans and right heart catheterizations (RHC) were included. CT diameters of the main pulmonary artery (MPA), right (RPA) and left (LPA), and ascending aorta (AA) were measured. The relationship between CT measurements and PA pressures assessing using RHC was tested with linear regression. Results: The CT derived ratio of the diameter of the MPA to the diameter of the AA (PA/AAratio) correlated best with mean PA pressure (R2 = 0.48) and PA systolic pressure (R2 = 0.50). Receiver operating characteristic curve analysis showed that the PA/AAratio is a moderate predictor of PH (AUC 0.74, 95% CI 0.65-0.83, p < 0.0001) and that the optimal cut off point is 0.80 (sensitivity 56%, specificity 88%, positive predictive value 95.5%, negative predictive value 30.6% for PH). Conclusions: Elderly patients with severe AS and PA/AAratio values ≥ 0.80 on MDCT are more likely to have PH but PH cannot be reliably excluded among such patients with lower PA/AAratio values.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA