Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
1.
Pediatr Emerg Care ; 40(3): 197-202, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38416651

RESUMO

OBJECTIVES: The aim of this study was to compare the endotracheal tube (ET) and intravenous (IV) administration of epinephrine relative to concentration maximum, time to maximum concentration, mean concentration over time (MC), area under the curve, odds, and time to return of spontaneous circulation (ROSC) in a normovolemic pediatric cardiac arrest model. METHODS: Male swine weighing 24-37 kg were assigned to 4 groups: ET (n = 8), IV (n = 7), cardiopulmonary resuscitation (CPR) + defibrillation (CPR + Defib) (n = 5), and CPR only (n = 3). Swine were placed arrest for 2 minutes, and then CPR was initiated for 2 minutes. Epinephrine (0.1 mg/kg) for the ET group or 0.01 mg/kg for the IV was administered every 4 minutes or until ROSC. Defibrillation started at 3 minutes and continued every 2 minutes for 30 minutes or until ROSC for all groups except the CPR-only group. Blood samples were collected over a period of 5 minutes. RESULTS: The MC of plasma epinephrine for the IV group was significantly higher at the 30- and 60-second time points (P = 0.001). The ET group had a significantly higher MC of epinephrine at the 180- and 240-second time points (P < 0.05). The concentration maximum of plasma epinephrine was significantly lower for the ET group (195 ± 32 ng/mL) than for the IV group (428 ± 38 ng/mL) (P = 0.01). The time to maximum concentration was significantly longer for the ET group (145 ± 26 seconds) than for the IV group (42 ± 16 seconds) (P = 0.01). No significant difference existed in area under the curve between the 2 groups (P = 0.62). The odds of ROSC were 7.7 times greater for the ET versus IV group. Time to ROSC was not significantly different among the IV, ET, and CPR + Defib groups (P = 0.31). CONCLUSIONS: Based on the results of this study, the ET route of administration should be considered a first-line intervention.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Suínos , Masculino , Humanos , Animais , Criança , Vasoconstritores/uso terapêutico , Reanimação Cardiopulmonar/métodos , Epinefrina/farmacologia , Parada Cardíaca/tratamento farmacológico , Infusões Intravenosas
2.
Pediatr Radiol ; 53(12): 2380-2385, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37773443

RESUMO

BACKGROUND: MR arthrography is an essential diagnostic tool to assess and guide management of labral, ligamentous, fibrocartilaginous, and capsular abnormalities in children. While fluoroscopy is traditionally used for intra-articular contrast administration, ultrasound offers advantages of portability and lack of ionizing radiation exposure for both the patient and proceduralist. OBJECTIVE: The purpose of this retrospective study is to quantify technical success and frequency of complications of ultrasound-guided arthrogram injections at our institution. MATERIALS AND METHODS: This retrospective analysis investigates the results of 217 ultrasound-guided arthrograms of the shoulder, elbow, and hip in patients aged 5-18 years. Successful injection of contrast into the target joint, clinical indication for MR arthrography, and complications were reviewed. RESULTS: Accurate ultrasound-guided intra-articular administration of contrast into the target joint was successful for 100% of shoulder cases (90/90), 97% of elbow cases (77/79), and 98% of hip cases (47/48). Leak of contrast outside the target joint occurred in 1.4% (3/217) of cases. No major side effects including excessive bleeding, paresthesia, allergic reactions, or infection occurred during or after the procedure. Additionally, no major vessel, nerve, or tendon complications were observed on MR images. CONCLUSION: Ultrasound guidance is a reliable, effective, and safe approach to arthrography in children.


Assuntos
Artrografia , Articulação do Ombro , Humanos , Criança , Artrografia/métodos , Estudos Retrospectivos , Meios de Contraste , Injeções Intra-Articulares , Articulação do Ombro/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ultrassonografia de Intervenção/métodos
3.
Vet Surg ; 52(3): 379-387, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36625290

RESUMO

OBJECTIVE: To determine the influence of radiographic examination on the recommendations made at the time of planned re-evaluation of dogs after medial patellar luxation (MPL) surgery. STUDY DESIGN: Retrospective multi-institutional case series. ANIMALS: Client-owned dogs (N = 825) that underwent MPL surgery. METHODS: Records of 10 referral institutions were searched for dogs that had been treated surgically for unilateral MPL and underwent a planned follow-up visit, including radiographs. The frequency of, and reasons for, changes in further recovery recommendations were investigated. RESULTS: Follow up was performed at a median of 6 (range, 4-20) weeks postoperatively. Isolated radiographic abnormalities were identified in 3.3% (27/825) of dogs following MPL surgery and led to a change in recommendations in 3% (13/432) of dogs that were presented without owner or clinician concerns. Lameness, administration of analgesia at follow up, and history of unplanned visits prior to routine re-examination were associated with a change in postoperative plan (P < .001). In the absence of owner and clinician concerns, the odds of having a change in convalescence plans were not different, whether or not isolated radiographic abnormalities were present (P = .641). CONCLUSION: Routine radiographs at follow up did not influence postoperative management of most dogs after MPL surgery in the absence of abnormalities on clinical history or orthopedic examination. CLINICAL SIGNIFICANCE: Dogs that were presented for routine follow up after unilateral MPL surgery without owner concerns, lameness, analgesic treatment or a history of unplanned visits, and for which examination by a surgical specialist was unremarkable, were unlikely to benefit from radiographs.


Assuntos
Doenças do Cão , Luxação Patelar , Animais , Cães , Doenças do Cão/diagnóstico por imagem , Doenças do Cão/cirurgia , Seguimentos , Coxeadura Animal/diagnóstico por imagem , Coxeadura Animal/cirurgia , Luxação Patelar/diagnóstico por imagem , Luxação Patelar/cirurgia , Luxação Patelar/veterinária , Estudos Retrospectivos , Joelho de Quadrúpedes/diagnóstico por imagem , Joelho de Quadrúpedes/cirurgia
4.
Can Assoc Radiol J ; 74(4): 629-634, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36718778

RESUMO

Purpose: Determine whether standardized template reporting for the preoperative assessment of potential living renal transplant donors improves the comprehensiveness of radiology reports to meet the needs of urologists performing renal transplants. Methods: Urologist and radiologist stakeholders from renal transplant centres in our province ratified a standardized reporting template for evaluation of potential renal donors. Three centres (A, B, and C) were designated "intervention" groups. Centre D was the control group, given employment of a site-specific standardized template prior to study commencement. Up to 100 consecutive CT scan reports per centre, pre- and post-implementation of standardized reporting, were evaluated for reporting specific outcome measures. Results: At baseline, all intervention groups demonstrated poor reporting of urologist-desired outcome measures. Centre A discussed 5/13 variables (38%), Centre B discussed 6/13 variables (46%), and Centre C only discussed 1/13 variables (8%) with ≥90% reliability. The control group exhibited consistent reporting, with 11/13 variables (85%) reported at ≥90% reliability. All institutions in the intervention group exhibited excellent compliance to structured reporting post-template implementation (Centres A = 95%, B = 100%, and C = 77%, respectively). Additionally, all intervention centres demonstrated a significant improvement in the comprehensiveness of reports post-template implementation, with statistically significant increases in the reporting of all variables under-reported at baseline (P > .01). Conclusion: Standardized templates across our province for CT scans of potential renal donors promote completeness of reports. Radiologists can reliably provide our surgical colleagues with needed preoperative anatomy and incidental findings, helping to determine suitable transplant donors and reduce potential complications associated with organ retrieval.


Assuntos
Transplante de Rim , Urologistas , Humanos , Imageamento por Ressonância Magnética , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
5.
BJOG ; 129(13): 2150-2156, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35866444

RESUMO

OBJECTIVE: To investigate maternal lactate concentrations in labour and the puerperium. DESIGN: Reference study. SETTING: Tertiary obstetric unit. POPULATION: 1279 pregnant women with good perinatal outcomes at term. METHODS: Electronic patient records were searched for women who had lactate measured on the day of delivery or in the following 24 hours, but who were subsequently found to have a very low likelihood of sepsis, based on their outcomes. MAIN OUTCOME MEASURES: The normative distribution of lactate and C-reactive protein (CRP), differences according to the mode of birth, and the proportion of results above the commonly used cut-offs (≥2 and ≥4 mmol/l). RESULTS: Lactate varied between 0.4-5.4 mmol/l (median 1.8 mmol/l, interquartile range [IQR] 1.3-2.5). It was higher in women who had vaginal deliveries than caesarean sections (median 1.9 vs. 1.6 mmol/l, pdiff  < 0.001), demonstrating the association with labour (particularly active pushing in the second stage). In contrast, CRP was more elevated in women who had caesarean sections (median 71.8 mg/l) than those who had vaginal deliveries (33.4 mg/l, pdiff  < 0.001). In total, 40.8% had a lactate ≥2 mmol/l, but 95.3% were <4 mmol/l. CONCLUSIONS: Lactate in labour and the puerperium is commonly elevated above the levels expected in healthy pregnant or non-pregnant women. There is a paucity of evidence to support using lactate or CRP to make decisions about antibiotics around the time of delivery but, as lactate is rarely higher than 4 mmol/l, this upper limit may still represent a useful severity marker for the investigation and management of sepsis in labour.


Assuntos
Trabalho de Parto , Sepse , Gravidez , Feminino , Humanos , Ácido Láctico , Parto Obstétrico , Cesárea , Sepse/diagnóstico
6.
Pediatr Emerg Care ; 38(1): e187-e192, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-32701868

RESUMO

OBJECTIVE: Early administration of epinephrine increases the incidence of return of spontaneous circulation (ROSC) and improves outcomes among pediatric cardiac arrest victims. Rapid endotracheal (ET) intubation can facilitate early administration of epinephrine to pediatric victims. To date, no studies have evaluated the use of ET epinephrine in a pediatric hypovolemic cardiac arrest model to determine the incidence of ROSC. METHODS: This prospective, experimental study evaluated the pharmacokinetics and/or incidence of ROSC following ET administered epinephrine and compared it to these experimental groups: intravenous (IV) administered epinephrine, cardiopulmonary resuscitation only (CPR), and CPR + defibrillation (CPR + Defib). RESULTS: Endotracheal administered epinephrine, at the Pediatric Advanced Life Support (PALS) recommended dose, was not significantly different than IV administered epinephrine in maximum plasma concentrations, time to maximum plasma concentration, area under the curve, or ROSC, or mean plasma concentrations at various time points (P > 0.05). The odds of ROSC in the ET group were 2.4 times greater than the IV group. The onset to ROSC in the ET group was significantly shorter than the IV group (P < 0.0001). CONCLUSIONS: These data support that ET epinephrine administration remains an alternative to IV administered epinephrine and faster at restoring ROSC among pediatric hypovolemic cardiac arrest victims in the acute setting when an endotracheal tube is present. Although further research is required to determine long-term outcomes of high-dose ET epinephrine administration, these data reinforce the therapeutic potential of ET administration of epinephrine to restore ROSC before IV access.


Assuntos
Parada Cardíaca , Hipovolemia , Animais , Epinefrina/uso terapêutico , Parada Cardíaca/tratamento farmacológico , Humanos , Infusões Intraósseas , Estudos Prospectivos , Distribuição Aleatória , Retorno da Circulação Espontânea , Suínos , Vasoconstritores/uso terapêutico
7.
Pediatr Emerg Care ; 38(4): e1166-e1172, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32453255

RESUMO

OBJECTIVE: We compared the efficacy of tibial intraosseous (TIO) administration of epinephrine in a pediatric normovolemic versus hypovolemic cardiac arrest model to determine the incidence of return of spontaneous circulation (ROSC) and plasma epinephrine concentrations over time. METHODS: This experimental study evaluated the pharmacokinetics of epinephrine and/or incidence of ROSC after TIO administration in either a normovolemic or hypovolemic pediatric swine model. RESULTS: All subjects in the TIO normovolemia cardiac arrest group experienced ROSC after TIO administration of epinephrine. In contrast, subjects experiencing hypovolemia and cardiac arrest were significantly less likely to experience ROSC when epinephrine was administered TIO versus intravenous (TIO hypovolemia: 14% [1/7] vs IV hypovolemia: 71% [5/7]; P = 0.031). The TIO hypovolemia group exhibited significantly lower plasma epinephrine concentrations versus IV hypovolemia at 60, 90, 120, and 150 seconds (P < 0.05). Although the maximum concentration of plasma epinephrine was similar, the TIO hypovolemia group exhibited significantly slower time to maximum concentration times versus TIO normovolemia subjects (P = 0.004). CONCLUSIONS: Tibial intraosseous administration of epinephrine reliably facilitated ROSC among normovolemic cardiac arrest pediatric patients, which is consistent with published reports. However, TIO administration of epinephrine was ineffective in restoring ROSC among subjects experiencing hypovolemia and cardiac arrest. Tibial intraosseous-administered epinephrine during hypovolemia and cardiac arrest may have resulted in a potential sequestration of epinephrine in the tibia. Central or peripheral intravascular access attempts should not be abandoned after successful TIO placement in the resuscitation of patients experiencing concurrent hypovolemia and cardiac arrest.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Animais , Reanimação Cardiopulmonar/métodos , Modelos Animais de Doenças , Epinefrina/uso terapêutico , Parada Cardíaca/tratamento farmacológico , Humanos , Hipovolemia/tratamento farmacológico , Distribuição Aleatória , Retorno da Circulação Espontânea , Suínos , Tíbia
8.
J Appl Clin Med Phys ; 22(5): 6-14, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33797840

RESUMO

PURPOSE: The objective of this study was to investigate the dosimetric impact of range uncertainty in a large cohort of patients receiving passive scatter proton therapy. METHODS: A cohort of 120 patients were reviewed in this study retrospectively, of which 61 were brain, 39 lung, and 20 prostate patients. Range uncertainties of ±3.5% (overshooting and undershooting by 3.5%, respectively) were added and recalculated on the original plans, which had been planned according to our clinical planning protocol while keeping beamlines, apertures, compensators, and dose grids intact. Changes in the coverage on CTV and DVH for critical organs were compared and analyzed. Correlation between dose change and minimal distance between CTV and critical organs were also investigated. RESULTS: Although CTV coverages and maximum dose to critical organs were largely maintained for most brain patients, large variations over 5% were still observed sporadically. Critical organs, such as brainstem and chiasm, could still be affected by range uncertainty at 4 cm away from CTV. Coverage and OARs in lung and prostate patients were less likely to be affected by range uncertainty with very few exceptions. CONCLUSION: The margin recipe in modern TPS leads to clinically acceptable OAR doses in the presence of range uncertainties. However, range uncertainties still pose a noticeable challenge for small but critical serial organs near tumors, and occasionally for large parallel organs that are located distal to incident proton beams.


Assuntos
Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Masculino , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Incerteza
9.
J Shoulder Elbow Surg ; 29(9): 1938-1949, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32815808

RESUMO

BACKGROUND: Proximal humerus fractures are common in the elderly population and are often treated with reverse shoulder arthroplasty (RSA). The purpose of this systematic review was to compare tuberosity healing and functional outcomes in patients undergoing RSA with humeral inclinations of 135°, 145°, and 155°. METHODS: A systematic review was performed of RSA for proximal humerus fracture using Preferred Reporting Items for Systemic Reviews and Meta-Analyses (PRISMA) guidelines. Radiographic and functional outcome data were extracted to evaluate tuberosity healing according to humeral inclination. Analysis was also performed of healed vs. nonhealed tuberosities. RESULTS: A total of 873 patients in 21 studies were included in the analysis. The mean age was 77.5 years (range of 58-97) and the mean follow-up was 26.2 months. Tuberosity healing was 83% in the 135° group compared with 69% in the 145° group and 66% in the 155° group (P = .030). Postoperative abduction was highest in the 155° group (P < .001). No significant difference was found in forward flexion, external rotation, or postoperative Constant score between groups. Patients with tuberosity healing demonstrated 18° higher forward flexion (P = .008) and 16° greater external rotation (P < .001) than those with unhealed tuberosities. CONCLUSION: RSA for fracture with 135° humeral inclination is associated with higher tuberosity healing rates compared with 145° or 155°. Postoperative abduction is highest with a 155° implant, but there is no difference in in postoperative forward flexion, external rotation, or Constant score according to humeral inclination. Patients with healed tuberosities have superior postoperative forward flexion and external rotation than those with unhealed tuberosities.


Assuntos
Artroplastia do Ombro , Úmero/fisiopatologia , Fraturas do Ombro/cirurgia , Articulação do Ombro/fisiopatologia , Cicatrização , Artroplastia do Ombro/métodos , Humanos , Úmero/diagnóstico por imagem , Úmero/cirurgia , Próteses e Implantes , Amplitude de Movimento Articular , Estudos Retrospectivos , Rotação , Fraturas do Ombro/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Resultado do Tratamento
10.
AJR Am J Roentgenol ; 213(4): 844-850, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31180739

RESUMO

OBJECTIVE. The purpose of this study was to assess prostate multiparametric MRI (mpMRI) before and after intervention by a director of prostate imaging. MATERIALS AND METHODS. Images from prostate mpMRI examinations at four peripheral institutions (five 1.5-T systems) were studied. DICOM headers were analyzed for T2-weighted, DWI, and dynamic contrast-enhanced technical specifications. Reports were retrieved, and a blinded radiologist compared them with those from the regional academic referral center (3-T system) and Prostate Imaging and Data Reporting System version 2 (PI-RADSv2) technical specifications. Data were reevaluated after intervention by a director of prostate imaging. Comparisons were performed by chi-square analysis. RESULTS. Except for having insufficient DWI spatial resolution, the referral center fully complied with PI-RADSv2. For peripheral systems, compliance with PI-RADSv2 technical specifications improved from baseline to after intervention. For T2-weighted imaging, compliance with spatial resolution increased from 40% (two of five MRI systems) to 100% (all five systems) (p = 0.038). For DWI, spatial resolution compliance increased from 20% to 100%. For modified DWI, spatial resolution compliance to improve image quality at 1.5 T (matrix, 100 × 100; FOV, 28 × 28 cm; slice thickness, 4 mm) increased from 60% (b value ≥ 1400 s/mm2) to 100% (p = 0.114). For dynamic contrast-enhanced imaging, spatial resolution compliance increased from 60% to 100% (p = 0.114), temporal resolution compliance increased from 20% (≤ 10 seconds) to 100% (p = 0.10), and acquisition time compliance increased from 60% (≥ 2 minutes) to 100% (p = 0.114). Only one of the four peripheral centers provided PI-RADSv2 scores, but all of them did after the intervention (p = 0.028). CONCLUSION. A director of prostate imaging may drive standardization of prostate MRI performance and reporting within specified geographic regions.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica/normas , Neoplasias da Próstata/diagnóstico por imagem , Meios de Contraste , Imagem de Difusão por Ressonância Magnética , Humanos , Masculino , Razão Sinal-Ruído
11.
Am J Emerg Med ; 37(11): 2043-2050, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30853153

RESUMO

INTRODUCTION: Limited prospective data exist regarding epinephrine's controversial role in managing traumatic cardiac arrest (TCA). This study compared the maximum concentration (Cmax), time to maximum concentration (Tmax), plasma concentration over time, return of spontaneous circulation (ROSC), time to ROSC, and odds of ROSC of epinephrine administered by the endotracheal (ETT), intraosseous (IO), and intravenous (IV) routes in a swine TCA model. METHODS: Forty-nine Yorkshire-cross swine were assigned to seven groups: ETT, tibial IO (TIO), sternal IO (SIO), humeral IO (HIO), IV, CPR with defibrillation (CPRD), and CPR only. Swine were exsanguinated 31% of their blood volume and cardiac arrest induced. Chest compressions began 2 min post-arrest. At 4 min post-arrest, 1 mg epinephrine was administered, and blood specimens collected over 4 min. Resuscitation continued until ROSC or 30 min elapsed. RESULTS: The Cmax of IV epinephrine was significantly higher than the TIO group (P = 0.049). No other differences in Cmax, Tmax, ROSC, and time to ROSC existed between the epinephrine groups (P > 0.05). Epinephrine levels were detectable in two of seven ETT swine. No significant difference in ROSC existed between the epinephrine groups and CPRD group (P > 0.05). Significant differences in ROSC existed between all groups and the CPR only group (P < 0.05). No significant differences in odds of ROSC were noted. CONCLUSIONS: The pharmacokinetics of IV, HIO, and SIO epinephrine were comparable. Endotracheal epinephrine absorption was highly variable and unreliable compared to IV and IO epinephrine. Epinephrine appeared to have a lesser role than volume replacement in resuscitating TCA.


Assuntos
Epinefrina/farmacocinética , Parada Cardíaca/tratamento farmacológico , Simpatomiméticos/farmacocinética , Ferimentos e Lesões/complicações , Animais , Epinefrina/administração & dosagem , Epinefrina/sangue , Epinefrina/uso terapêutico , Parada Cardíaca/sangue , Parada Cardíaca/etiologia , Infusões Intraósseas , Infusões Intravenosas , Intubação Intratraqueal , Masculino , Estudos Prospectivos , Distribuição Aleatória , Sus scrofa , Simpatomiméticos/administração & dosagem , Simpatomiméticos/sangue , Simpatomiméticos/uso terapêutico
12.
Arthroscopy ; 33(12): 2110-2116, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28866347

RESUMO

PURPOSE: To develop a model using wearable inertial sensors to assess the performance of orthopaedic residents while performing a diagnostic knee arthroscopy. METHODS: Fourteen subjects performed a diagnostic arthroscopy on a cadaveric right knee. Participants were divided into novices (5 postgraduate year 3 residents), intermediates (5 postgraduate year 4 residents), and experts (4 faculty) based on experience. Arm movement data were collected by inertial measurement units (Opal sensors) by securing 2 sensors to each upper extremity (dorsal forearm and lateral arm) and 2 sensors to the trunk (sternum and lumbar spine). Kinematics of the elbow and shoulder joints were calculated from the inertial data by biomechanical modeling based on a sequence of links connected by joints. Range of motion required to complete the procedure was calculated for each group. Histograms were used to compare the distribution of joint positions for an expert, intermediate, and novice. RESULTS: For both the right and left upper extremities, skill level corresponded well with shoulder abduction-adduction and elbow prono-supination. Novices required on average 17.2° more motion in the right shoulder abduction-adduction plane than experts to complete the diagnostic arthroscopy (P = .03). For right elbow prono-supination (probe hand), novices required on average 23.7° more motion than experts to complete the procedure (P = .03). Histogram data showed novices had markedly more variability in shoulder abduction-adduction and elbow prono-supination compared with the other groups. CONCLUSIONS: Our data show wearable inertial sensors can measure joint kinematics during diagnostic knee arthroscopy. Range-of-motion data in the shoulder and elbow correlated inversely with arthroscopic experience. Motion pattern-based analysis shows promise as a metric of resident skill acquisition and development in arthroscopy. CLINICAL RELEVANCE: Wearable inertial sensors show promise as metrics of arthroscopic skill acquisition among residents.


Assuntos
Artroscopia/educação , Competência Clínica/estatística & dados numéricos , Articulação do Cotovelo/fisiologia , Articulação do Ombro/fisiologia , Dispositivos Eletrônicos Vestíveis , Fenômenos Biomecânicos , Cadáver , Humanos , Internato e Residência/métodos , Articulação do Joelho/cirurgia , Ortopedia/educação , Amplitude de Movimento Articular
13.
Can Assoc Radiol J ; 68(3): 243-248, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28159436

RESUMO

PURPOSE: The study sought to determine if the Quality Initiative Program (QUIP) has become part of the radiology culture at our institution. METHODS: After Research Ethics approval, QUIPs from January 2009 to December 2014 were assessed. We evaluated the response rates of radiologists receiving QUIPs to ensure they reviewed them. We performed a survey of radiologists and trainees to gain feedback regarding their perception of QUIPs in February 2014 and in June 2015. RESULTS: Response rates of radiologists receiving a QUIP improved, with 76% response rate in 2014 up from 66% in the first year and 42% in the second year. Based on the 2015 survey including radiologists and trainees, 75% agreed that QUIPs were educational, compared with 67% 16 months earlier. Fifty percent of respondents had changed their overall practice of reporting based on feedback from the QUIP in 2015 compared with 32% in 2014. In both surveys, 100% of respondents indicated that QUIPs have not been used against them for any disciplinary measure (or other negatively perceived action). When asked if there was a perceived decrease in stigma felt when a QUIP was received, 71% agreed or were neutral and 28% disagreed. CONCLUSIONS: The QUIP is educational to radiologists and trainees, leading to positive changes in clinical practice. The majority accepts this program but there is still a stigma felt when a QUIP is received, particularly among residents. Nevertheless, we feel that QUIP has been integrated into our radiology culture and, hopefully, imminent transition to commercial quality software will be smooth.


Assuntos
Erros de Diagnóstico/estatística & dados numéricos , Garantia da Qualidade dos Cuidados de Saúde , Radiologia/educação , Radiologia/normas , Correio Eletrônico , Feminino , Humanos , Masculino , Cultura Organizacional , Melhoria de Qualidade , Estudos Retrospectivos , Inquéritos e Questionários
14.
Artigo em Inglês | MEDLINE | ID: mdl-28572719

RESUMO

Model-based image reconstruction (MBIR) techniques have the potential to generate high quality images from noisy measurements and a small number of projections which can reduce the x-ray dose in patients. These MBIR techniques rely on projection and backprojection to refine an image estimate. One of the widely used projectors for these modern MBIR based technique is called branchless distance driven (DD) projection and backprojection. While this method produces superior quality images, the computational cost of iterative updates keeps it from being ubiquitous in clinical applications. In this paper, we provide several new parallelization ideas for concurrent execution of the DD projectors in multi-GPU systems using CUDA programming tools. We have introduced some novel schemes for dividing the projection data and image voxels over multiple GPUs to avoid runtime overhead and inter-device synchronization issues. We have also reduced the complexity of overlap calculation of the algorithm by eliminating the common projection plane and directly projecting the detector boundaries onto image voxel boundaries. To reduce the time required for calculating the overlap between the detector edges and image voxel boundaries, we have proposed a pre-accumulation technique to accumulate image intensities in perpendicular 2D image slabs (from a 3D image) before projection and after backprojection to ensure our DD kernels run faster in parallel GPU threads. For the implementation of our iterative MBIR technique we use a parallel multi-GPU version of the alternating minimization (AM) algorithm with penalized likelihood update. The time performance using our proposed reconstruction method with Siemens Sensation 16 patient scan data shows an average of 24 times speedup using a single TITAN X GPU and 74 times speedup using 3 TITAN X GPUs in parallel for combined projection and backprojection.

15.
Can Assoc Radiol J ; 66(1): 86-93, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25623012

RESUMO

PURPOSE: The objective of this study was to introduce 3 new quality initiatives in radiology that engage various members of the department including radiologists, residents, technologists, and booking clerks. These pilot programs provide work-related learning opportunities in semiautomated, easy-to-use, email-based, standardized forms that are used to identify cases where imaging could have been performed in a more optimal way (either due to technical reasons or a different protocol could have been chosen). In the case of the Kudos quality initiative program (QUIP), this is used to provide positive feedback to an individual in the department for a job well done. METHODS: Since inception in January 2012 to September 2013, we reviewed Technical QUIPs, protocols under questions (PUQ), and Kudos QUIPs. These were collated through receipt of standardized emails for each category. RESULTS: A total of 62 Kudos QUIPs, 8 Technical QUIPs, and 58 PUQs were received in the abdominal and pelvic imaging division since inception. CONCLUSIONS: Though still a relatively new pilot programs, PUQs and Technical QUIPs have afforded technologists and booking clerks opportunities to become engaged in improving patient care as well as learning from their own performance gaps. Future standardization of received data for each modality still needs to be established as well as an action plan to implement long-term changes.


Assuntos
Retroalimentação Psicológica , Equipe de Assistência ao Paciente/normas , Garantia da Qualidade dos Cuidados de Saúde , Radiologia/organização & administração , Radiologia/normas , Pessoal Administrativo , Correio Eletrônico , Humanos , Conhecimento Psicológico de Resultados , Projetos Piloto , Recompensa , Tecnologia Radiológica
16.
J Opt Soc Am A Opt Image Sci Vis ; 31(7): 1369-94, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-25121423

RESUMO

We investigate new sampling strategies for projection tomography, enabling one to employ fewer measurements than expected from classical sampling theory without significant loss of information. Inspired by compressed sensing, our approach is based on the understanding that many real objects are compressible in some known representation, implying that the number of degrees of freedom defining an object is often much smaller than the number of pixels/voxels. We propose a new approach based on quasi-random detector subsampling, whereas previous approaches only addressed subsampling with respect to source location (view angle). The performance of different sampling strategies is considered using object-independent figures of merit, and also based on reconstructions for specific objects, with synthetic and real data. The proposed approach can be implemented using a structured illumination of the interrogated object or the detector array by placing a coded aperture/mask at the source or detector side, respectively. Advantages of the proposed approach include (i) for structured illumination of the detector array, it leads to fewer detector pixels and allows one to integrate detectors for scattered radiation in the unused space; (ii) for structured illumination of the object, it leads to a reduced radiation dose for patients in medical scans; (iii) in the latter case, the blocking of rays reduces scattered radiation while keeping the same energy in the transmitted rays, resulting in a higher signal-to-noise ratio than that achieved by lowering exposure times or the energy of the source; (iv) compared to view-angle subsampling, it allows one to use fewer measurements for the same image quality, or leads to better image quality for the same number of measurements. The proposed approach can also be combined with view-angle subsampling.

17.
Appl Opt ; 52(32): 7745-54, 2013 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-24216733

RESUMO

We examine coding strategies for coded aperture scatter imagers. Scatter imaging enables tomography of compact regions from snapshot measurements. We present coded aperture designs for pencil and fan beam geometries, and compare their singular value spectra with that of the Radon transform and selected volume tomography. We show that under dose constraints scatter imaging improves conditioning over alternative techniques, and that specially designed coded apertures enable snapshot 1D and 2D tomography.

18.
Phys Med Biol ; 68(24)2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-37802071

RESUMO

Objective.Over the past several decades, dual-energy CT (DECT) imaging has seen significant advancements due to its ability to distinguish between materials. DECT statistical iterative reconstruction (SIR) has exhibited potential for noise reduction and enhanced accuracy. However, its slow convergence and substantial computational demands render the elapsed time for 3D DECT SIR often clinically unacceptable. The objective of this study is to accelerate 3D DECT SIR while maintaining subpercentage or near-subpercentage accuracy.Approach.We incorporate DECT SIR into a deep-learning model-based unrolling network for 3D DECT reconstruction (MB-DECTNet), which can be trained end-to-end. This deep learning-based approach is designed to learn shortcuts between initial conditions and the stationary points of iterative algorithms while preserving the unbiased estimation property of model-based algorithms. MB-DECTNet comprises multiple stacked update blocks, each containing a data consistency layer (DC) and a spatial mixer layer, with the DC layer functioning as a one-step update from any traditional iterative algorithm.Main results.The quantitative results indicate that our proposed MB-DECTNet surpasses both the traditional image-domain technique (MB-DECTNet reduces average bias by a factor of 10) and a pure deep learning method (MB-DECTNet reduces average bias by a factor of 8.8), offering the potential for accurate attenuation coefficient estimation, akin to traditional statistical algorithms, but with considerably reduced computational costs. This approach achieves 0.13% bias and 1.92% mean absolute error and reconstructs a full image of a head in less than 12 min. Additionally, we show that the MB-DECTNet output can serve as an initializer for DECT SIR, leading to further improvements in results.Significance.This study presents a model-based deep unrolling network for accurate 3D DECT reconstruction, achieving subpercentage error in estimating virtual monoenergetic images for a full head at 60 and 150 keV in 30 min, representing a 40-fold speedup compared to traditional approaches. These findings have significant implications for accelerating DECT SIR and making it more clinically feasible.


Assuntos
Cabeça , Processamento de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Algoritmos
19.
Phys Med Biol ; 68(14)2023 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-37327796

RESUMO

Objective.Dual-energy computed tomography (DECT) has been widely used to reconstruct numerous types of images due its ability to better discriminate tissue properties. Sequential scanning is a popular dual-energy data acquisition method as it requires no specialized hardware. However, patient motion between two sequential scans may lead to severe motion artifacts in DECT statistical iterative reconstructions (SIR) images. The objective is to reduce the motion artifacts in such reconstructions.Approach.We propose a motion-compensation scheme that incorporates a deformation vector field into any DECT SIR. The deformation vector field is estimated via the multi-modality symmetric deformable registration method. The precalculated registration mapping and its inverse or adjoint are then embedded into each iteration of the iterative DECT algorithm.Main results.Results from a simulated and clinical case show that the proposed framework is capable of reducing motion artifacts in DECT SIRs. Percentage mean square errors in regions of interest in the simulated and clinical cases were reduced from 4.6% to 0.5% and 6.8% to 0.8%, respectively. A perturbation analysis was then performed to determine errors in approximating the continuous deformation by using the deformation field and interpolation. Our findings show that errors in our method are mostly propagated through the target image and amplified by the inverse matrix of the combination of the Fisher information and Hessian of the penalty term.Significance.We have proposed a novel motion-compensation scheme to incorporate a 3D registration method into the joint statistical iterative DECT algorithm in order to reduce motion artifacts caused by inter-scan motion, and successfully demonstrate that interscan motion corrections can be integrated into the DECT SIR process, enabling accurate imaging of radiological quantities on conventional SECT scanners, without significant loss of either computational efficiency or accuracy.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Movimento (Física) , Imagens de Fantasmas , Artefatos
20.
AANA J ; 80(4 Suppl): S6-10, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23248824

RESUMO

The purpose of this study was to determine and compare the maximum concentration (C(max)) and time to maximum concentration (T(max)) of epinephrine administered via tibial intraosseous (IO), sternal IO, and intravenous (i.v.) routes in a porcine model of cardiac arrest during cardiopulmonary resuscitation. Five pigs each were randomly assigned to 3 groups: tibial IO, sternal IO, and i.v. Cardiac arrest was induced with i.v. potassium chloride. After 2 minutes, cardiopulmonary resuscitation was initiated. Epinephrine was administered to each animal, and serial blood samples were collected over the next 3 minutes. Enzyme-linked immunosorbent assay was used to determine the epinephrine concentration. Multivariate analysis of variance helped determine if there were statistically significant differences between groups. There were significant differences in Cmax between the sternal IO and i.v. (P = .009) and tibial IO and i.v. (P = .03) groups but no significant difference between tibial and sternal IO groups (P = .75). Significant differences existed in Tmax between the tibial IO and i.v. (P = .04) and between tibial IO and sternal IO (P = .02) groups but no difference between the sternal IO and i.v. groups (P = .56). Intravenous administration of 1 mg of epinephrine resulted in a serum concentration 5.87 and 2.86 times greater than for the tibial and sternal routes, respectively.


Assuntos
Epinefrina/farmacocinética , Parada Cardíaca/tratamento farmacológico , Infusões Intraósseas/métodos , Esterno , Tíbia , Animais , Reanimação Cardiopulmonar/métodos , Epinefrina/sangue , Parada Cardíaca/induzido quimicamente , Infusões Intravenosas/métodos , Projetos Piloto , Suínos , Simpatomiméticos/sangue , Simpatomiméticos/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA