Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Radiol ; 143: 109903, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34392003

RESUMO

BACKGROUND: The new radial volumetric encoding RAVE-T2/T1 hybrid sequence is a modern three-dimensional sequence with multiparametric approach, which includes T2- and T1-weighted contrasts obtained in identical slice position during one measurement. However, the RAVE-T2/T1 hybrid sequence is not yet being used in clinical routine. PURPOSE: The aim of this study was to evaluate the RAVE-T2/T1 hybrid sequence in a pediatric population with a clinical indication for an abdominal MRI examination to demonstrate that the hybrid imaging may be less challenging to perform on children. MATERIALS AND METHODS: Our retrospective observational study included pediatric patients of all age groups and required for an abdominal MRI examination. Non-contrast standard axial T1 DIXON and non-contrast RAVE-T2/T1 hybrid sequence were obtained at 3 T. MRI studies were analyzed independently by two pediatric radiologists using a 5-point Likert-type scale in five different categories. T1- and T2-weighted sequences were each compared with the RAVE-T2/T1-sequence using a Wilcoxon signed-rank test. RESULTS: The analysis included 15 children (mean age, 11 years and 4 months, 7 girls and 8 boys). The Cohens Kappa of interrater agreement measured 0.62. The T2 weighted part of the RAVE-T2/T1 sequence was significantly better than the standard T2 HASTE sequence in four of five image quality categories: overall image quality (2.2 ± 0.7 vs 1.8 ± 0,7, p = 0.03), respiratory motion artefacts (3.8 ± 0.4 vs 2.0 ± 0.7, p <= 0.01), portal vein clarity (3.3 ± 0.8 vs 2.2 ± 0.7, p <= 0.01), hepatic margin sharpness (2.4 ± 1,0 vs 1.8 ± 0.7, p <= 0.01). The T1 weighted part of the RAVE-T2/T1 sequence was significantly better than the standard T1 DIXON weighted sequence in three of five image quality categories: respiratory motion artefacts (4.0 ± 0.2 vs 3.6 ± 0.8, p = 0.01), portal vein clarity (2.7 ± 0.9 vs 2.1 ± 0.7, p <= 0.01), hepatic margin sharpness (3.2 ± 0.7 vs 2.6 ± 0.9, p <= 0.01). CONCLUSIONS: The RAVE-T2/T1 hybrid sequence is feasible and equal compared to standard T1- and T2-weighted sequences in the assessment of abdominal organs in a pediatric population. Due to non-inferiority to the current standard sequences for abdominal imaging, the RAVE-T2/T1 hybrid sequence is a good alternative for children who cannot be examined in breath-hold technique.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Abdome/diagnóstico por imagem , Adolescente , Criança , Estudos de Viabilidade , Feminino , Humanos , Masculino , Respiração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA