Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Jpn J Clin Oncol ; 54(8): 911-916, 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-38717229

RESUMO

OBJECTIVE: Sarcomas of the bone and soft tissues are detected after the onset of pain, detectable mass and related symptoms in the absence of a standardized screening examination. However, primary chest wall sarcomas can be incidentally detected upon chest X-ray or computed tomography. Previous studies of incidental primary chest wall sarcomas lack prognosis and disease-specific clinical data. This study aimed to investigate the prognoses of patients with incidental chest wall sarcomas and compare them with those of symptomatic patients. METHODS: This study included 18 patients diagnosed with primary chest wall sarcoma between 2010 and 2023. Patient information such as age, sex, tumour diameter, tumour location, symptoms, treatment, time to treatment initiation, pathological diagnosis and outcome were retrospectively analysed. RESULTS: Among the 18 patients, the sarcomas were incidentally detected in five by chest X-ray and computed tomography in three and two patients, respectively. The pathological diagnoses of the patients were Ewing sarcoma, Chondrosarcoma grade 1, grade 2, periosteal osteosarcoma and malignant peripheral nerve sheath tumour. The patients had no symptoms at the first visit to our hospital, and no lesions in other organs were detected at the time of the initial examination. At the final follow-up, the patients remained disease-free after radical treatment. The tumour sizes of the five patients were significantly smaller than those of patients with symptoms (P = 0.003). CONCLUSIONS: The incidental detection of chest wall sarcomas and consequent early detection and treatment of tumours improves patient prognosis relative to that of symptomatically diagnosed patients.


Assuntos
Achados Incidentais , Sarcoma , Parede Torácica , Humanos , Masculino , Feminino , Parede Torácica/patologia , Parede Torácica/diagnóstico por imagem , Pessoa de Meia-Idade , Sarcoma/patologia , Sarcoma/diagnóstico por imagem , Sarcoma/diagnóstico , Sarcoma/terapia , Adulto , Prognóstico , Estudos Retrospectivos , Idoso , Adulto Jovem , Tomografia Computadorizada por Raios X , Adolescente , Neoplasias Torácicas/diagnóstico por imagem , Neoplasias Torácicas/patologia , Neoplasias Torácicas/diagnóstico , Neoplasias Torácicas/terapia , Neoplasias Ósseas/diagnóstico , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/patologia
2.
J Vasc Interv Radiol ; 34(11): 1963-1969, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37532095

RESUMO

PURPOSE: To assess the diagnostic performance of carbon dioxide (CO2) and intraprocedural unenhanced computed tomography (CT) for adrenal venous sampling (AVS) (CO2-intraprocedural unenhanced CT-AVS) in patients with primary aldosteronism (PA) and a history of iodine contrast medium allergy. MATERIALS AND METHODS: CO2-intraprocedural unenhanced CT-AVS was performed in 18 patients with iodine contrast media allergies at the authors' hospital between December 2015 and January 2021. CT and noncontrast magnetic resonance angiography were used to evaluate the preoperative adrenal vein anatomy. CO2 venography was performed to confirm adrenal vein catheterization. Additionally, intraprocedural unenhanced CT was also performed to confirm catheter position in the right adrenal gland. RESULTS: In all cases in which CO2-intraprocedural unenhanced CT-AVS was performed, the right and left adrenal veins were catheterized appropriately, leading to a localized diagnosis. Catheterization of the left adrenal vein was confirmed using CO2 venography in all cases. In 7 of the 18 cases, CO2 venography demonstrated selection of the right adrenal vein. In 15 of 18 cases, intraprocedural unenhanced CT demonstrated selection of the right adrenal vein. CONCLUSIONS: CO2-intraprocedural unenhanced CT-AVS demonstrated the same diagnostic ability for PA localization as conventional AVS with iodine contrast media. The proposed method is clinically feasible for AVS, in which iodine contrast media use is restricted.


Assuntos
Hiperaldosteronismo , Hipersensibilidade , Iodo , Humanos , Flebografia/métodos , Meios de Contraste/efeitos adversos , Dióxido de Carbono/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Glândulas Suprarrenais/diagnóstico por imagem , Glândulas Suprarrenais/irrigação sanguínea , Iodo/efeitos adversos , Hiperaldosteronismo/diagnóstico por imagem , Estudos Retrospectivos , Aldosterona
3.
Tohoku J Exp Med ; 259(2): 127-133, 2023 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-36517016

RESUMO

Laparoscopic adrenalectomy is currently the standard treatment modality for unilateral aldosterone-producing adenoma (APA); however, a less-invasive treatment is needed for its treatment. A new bipolar ablation system that poses a lower risk of complications has been recently developed. This study aimed to evaluate the safety and performance of a novel bipolar radiofrequency ablation (RFA) system for the treatment of APAs. Ablations were performed in an ex vivo study using bovine adrenal glands [group A: n = 6, single-probe; group B: n = 6, two probes, interprobe distance (ID) = 12 mm; group C: n = 6, two probes, ID = 20 mm]. The in vivo study was conducted in groups A and B (n = 2 each) using porcine adrenal glands. For the ex vivo study, the mean vertical diameter (Dv) of the coagulative necrosis area and the mean transverse diameter (Dt) values were 11.99 mm and 10.96 mm for group A, 12.66 mm and 10.0 mm for group B, and 23.37 mm and 22.10 mm for group C, respectively. For the in vivo study, the mean Dv and Dt values were 12.23 mm and 9.03 mm for group A, and 16.38 mm and 9.52 mm for group B, respectively. No heat-induced damage to the adjacent organs was observed. To our best knowledge, this is the first study to evaluate the performance of the bipolar system in RFA of the adrenal gland. RFA using the new bipolar ablation system is safe and produces a sufficient coagulation area to treat APAs.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Animais , Bovinos , Suínos , Fígado/cirurgia , Necrose/cirurgia , Glândulas Suprarrenais/cirurgia
4.
J Vasc Interv Radiol ; 28(2): 161-167.e1, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28007330

RESUMO

PURPOSE: To evaluate clinical outcomes of transcatheter arterial embolization (TAE) for adhesive capsulitis resistant to conservative treatments. MATERIALS AND METHODS: This study comprised 25 patients (18 women and 7 men; mean age, 53.8 y; range, 39-68 y) with adhesive capsulitis resistant to conservative treatments. TAE was performed, and adverse events (AEs), pain visual analog scale (VAS) score changes, range of motion (ROM), and American Shoulder and Elbow Surgeons (ASES) scores were assessed. RESULTS: Abnormal vessels were identified in all patients. No major AEs were associated with TAE. One patient was lost to follow-up. The remaining 24 patients were available for final follow-up (mean, 36.1 months; range, 30-44 months). Of the 24 patients, 16 (67%) experienced quick improvement of nighttime pain (ie, VAS scores decreased > 50% from baseline) within 1 week, and 21 (87%) improved within 1 month. In terms of mean overall pain (ie, pain at its worst), VAS scores significantly decreased at 1, 3, and 6 months after treatment (82 mm before treatment vs 52, 19, and 8 mm after treatment; P < .001). ASES scores significantly improved at 1, 3, and 6 months after treatment (16.1 before treatment vs 41.4, 69.1, and 83.5 after treatment; P < .001). No symptom recurrence or late-onset AEs were observed. Shoulder ROM and function further improved during midterm follow-up. CONCLUSIONS: TAE is a possible treatment option for patients with adhesive capsulitis that has failed to improve with conservative treatments.


Assuntos
Bursite/terapia , Embolização Terapêutica , Articulação do Ombro/irrigação sanguínea , Articulação do Ombro/fisiopatologia , Dor de Ombro/terapia , Adulto , Idoso , Angiografia , Fenômenos Biomecânicos , Bursite/diagnóstico , Bursite/fisiopatologia , Embolização Terapêutica/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Estudos Prospectivos , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Recidiva , Dor de Ombro/diagnóstico , Dor de Ombro/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
5.
J Shoulder Elbow Surg ; 26(10): e309-e318, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28495576

RESUMO

BACKGROUND: In patients with rotator cuff tears, muscle degeneration is known to be a predictor of irreparable tears and poor outcomes after surgical repair. Fatty infiltration and volume of the whole muscles constituting the rotator cuff were quantitatively assessed using 3-dimensional 2-point Dixon magnetic resonance imaging. METHODS: Ten shoulders with a partial-thickness tear, 10 shoulders with an isolated supraspinatus tear, and 10 shoulders with a massive tear involving supraspinatus and infraspinatus were compared with 10 control shoulders after matching age and sex. With segmentation of muscle boundaries, the fat fraction value and the volume of the whole rotator cuff muscles were computed. After reliabilities were determined, differences in fat fraction, muscle volume, and fat-free muscle volume were evaluated. RESULTS: Intra-rater and inter-rater reliabilities were regarded as excellent for fat fraction and muscle volume. Tendon rupture adversely increased the fat fraction value of the respective rotator cuff muscle (P < .002). In the massive tear group, muscle volume was significantly decreased in the infraspinatus (P = .035) and increased in the teres minor (P = .039). With subtraction of fat volume, a significant decrease of fat-free volume of the supraspinatus muscle became apparent with a massive tear (P = .003). CONCLUSION: Three-dimensional measurement could evaluate fatty infiltration and muscular volume with excellent reliabilities. The present study showed that chronic rupture of the tendon adversely increases the fat fraction of the respective muscle and indicates that the residual capacity of the rotator cuff muscles might be overestimated in patients with severe fatty infiltration.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Lesões do Manguito Rotador/diagnóstico por imagem , Manguito Rotador/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Atrofia Muscular/diagnóstico por imagem , Estudos Prospectivos
6.
BMC Cancer ; 16(1): 798, 2016 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-27737652

RESUMO

BACKGROUND: Historically, local control of recurrent sarcomas has been limited to radiotherapy when surgical re-resection is not feasible. For metastatic carcinomas to the bone or soft tissue, radiotherapy and some interventional radiology treatment along with other systemic therapies have been widely advocated due to the possibility of disseminated disease. These techniques are effective in alleviating pain and achieving local control for some tumor types, but it has not been effective for prolonged local control of most tumors. Recently, cryoablation has been reported to have satisfactory results in lung and liver carcinoma treatment. In this study, we analyzed the clinical outcome of CT-guided cryoablation for malignant bone and soft tissue tumors to elucidate potential problems associated with this procedure. METHODS: Since 2011, 11 CT-guided cryoablations in 9 patients were performed for locally recurrent or metastatic bone and soft tissue tumors (7 males and 2 females) at our institute. The patients' average age was 74.8 years (range 61-86) and the median follow up period was 24.1 months (range 5-48). Histological diagnosis included renal cell carcinoma (n = 4), dedifferentiated liposarcoma (n = 2), myxofibrosarcoma (n = 2), chordoma (n = 1), hepatocellular carcinoma (n = 1), and thyroid carcinoma (n = 1). Cryoablation methods, clinical outcomes, complications, and oncological outcomes were analyzed. RESULTS: There were 5 recurrent tumors and 6 metastatic tumors, and all cases had contraindication to either surgery, chemotherapy or radiotherapy. Two and 3 cycles of cryoablation were performed for bone and soft tissue tumors, respectively. The average length of the procedure was 101.1 min (range 63-187), and the average number of probes was 2.4 (range 2-3). Complications included 1 case of urinary retention in a patient with sacral chordoma who underwent prior carbon ion radiotherapy, 1 transient femoral nerve palsy, and 1 minor wound complication. At the final follow up, 4 patients showed no evidence of disease, 2 were alive with disease, and 3 died of disease. CONCLUSIONS: Reports regarding CT-guided cryoablation for musculoskeletal tumors are rare and the clinical outcomes have not been extensively studied. In our case series, CT-guided cryoablation had analgesic efficacy and there were no cases of local recurrence post procedure during the follow-up period. Although collection of further data regarding use of this technique is necessary, our data suggest that cryoablation is a promising option in medically inoperable musculoskeletal tumors.


Assuntos
Criocirurgia , Neoplasias de Tecidos Moles/diagnóstico , Neoplasias de Tecidos Moles/terapia , Cirurgia Assistida por Computador , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Criocirurgia/métodos , Feminino , Humanos , Estimativa de Kaplan-Meier , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Recidiva Local de Neoplasia , Neoplasias de Tecidos Moles/mortalidade , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
7.
Radiographics ; 36(7): 2199-2211, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27831840

RESUMO

Traumatic lymphorrhea is a rare but potentially life-threatening complication. Postoperative lymphorrhea is the leading cause of traumatic lymphorrhea and can arise anywhere within the lymphatic system. Leaks arising from the aortoiliac region to the thoracic duct (TD) and from hepatic lymphatics can be identified with intranodal lymphangiography and transhepatic lymphangiography, respectively. Therefore, an appropriate lymphangiography technique is essential for identifying the sources of leaks. Chylothorax resulting from damage to the TD can be serious because the TD transports large amounts of lymphatic fluid from the gastrointestinal, hepatic, and aortoiliac regions. Percutaneous TD embolization-comprising access to the TD followed by embolization-has recently become a minimally invasive alternative to surgical TD ligation for high-output chylothorax. The selection of access routes to the TD depends on its anatomy. If the TD cannot be approached by such means, other options include TD needle interruption or drainage of lymphatic fluid adjacent to the leakage point followed by sclerotherapy. Most cases of abdominal lymphorrhea arise from the aorta-iliac lymphatic system, and lymphangiography alone or computed tomography-guided sclerotherapy might be useful. Rarely, leakage may arise from hepatic lymphatics due to a damaged gastroduodenal ligament and can be visualized and embolized transhepatically. This article comprehensively reviews clinically relevant anatomic TD variations, lymphangiography techniques and criteria for their selection, and treatment strategies for lymphorrhea. ©RSNA, 2016.


Assuntos
Excisão de Linfonodo/métodos , Doenças Linfáticas/diagnóstico por imagem , Doenças Linfáticas/terapia , Linfografia/métodos , Cirurgia Assistida por Computador/métodos , Terapia Combinada/métodos , Diagnóstico Diferencial , Drenagem/métodos , Embolização Terapêutica/métodos , Medicina Baseada em Evidências , Humanos , Escleroterapia/métodos , Resultado do Tratamento
8.
Endoscopy ; 52(3): E98-E99, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31561266

Assuntos
Boca , Humanos
9.
J Vasc Interv Radiol ; 26(6): 910-4, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26003457

RESUMO

The present report describes 6 cases of adrenal venous sampling (AVS) in patients who underwent computed tomography (CT) during arteriography because cannulation of right adrenal veins was otherwise difficult. CT was performed during arteriography to obtain information on the location and direction of the right adrenal vein. Two right adrenal veins were visualized in 1 case. The right central adrenal vein was not visualized in 1 case owing to an injury from a previous unsuccessful AVS procedure, but the right renal capsular vein was well visualized. CT during arteriography could contribute to a high AVS success rate.


Assuntos
Doenças das Glândulas Suprarrenais/diagnóstico , Glândulas Suprarrenais/irrigação sanguínea , Cateterismo Periférico/métodos , Flebografia/métodos , Radiografia Intervencionista/métodos , Tomografia Computadorizada por Raios X , Veias , Testes de Função do Córtex Suprarrenal , Doenças das Glândulas Suprarrenais/sangue , Doenças das Glândulas Suprarrenais/etiologia , Adulto , Idoso , Biomarcadores/sangue , Cateterismo Periférico/instrumentação , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Dispositivos de Acesso Vascular
10.
BMC Musculoskelet Disord ; 16: 377, 2015 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-26637412

RESUMO

BACKGROUND: Standard imaging modality for the follow-up after prosthetic replacements for musculoskeletal tumor patients has been conventional radiography. This technique is effective in detecting subtle changes in bone adjacent to metal implants, but in many cases, radiographs do not lead to definitive diagnosis of postoperative adverse events such as acute infection, local recurrence of soft tissue tumor or soft tissue local recurrence of osseous sarcoma. Conventional MRI sequences have not been effective due to metal artifacts. In this study, we tried to elucidate the effectiveness of metal artifact suppression using novel sequence, multiacquisition variable-resonance image combination (MAVRIC), after musculoskeletal tumor surgeries. METHODS: We retrospectively analyzed 5 cases of malignant bone and soft tissue sarcoma patients who were reconstructed with metal prosthesis after wide resection of tumors. Images obtained using MAVRIC and short tau inversion recovery (STIR) were compared side by side. The paired MAVRIC and STIR images were qualitatively compared independently by two specialists for 4 parameters: visualization of bone - implant interface, visualization of surrounding soft tissues, image blurring, and overall image quality. Quantitatively, paired images were reviewed to identify the slice where the metal artifact was maximal, and a region of interest encompassing the implant and surrounding artifact was drawn using Advantage Workstation (GE Healthcare, Japan). RESULTS: There were no local recurrences that were detected. By utilizing MAVRIC, visualization of the bone - implant interface and visualization of the surrounding soft tissue were significantly improved in MAVRIC compared to STIR. Although blurring was worse on the MAVRIC acquisitions, the overall image quality was still better on MAVRIC. Quantitatively, the area of metal artifact measured using MAVRIC was markedly less compared to STIR (61.4 cm(2) vs 135.9 cm(2)). CONCLUSION: Despite the relatively small number of cases in the present study, our observation strongly suggests that MAVRIC is able to improve the quality of images by decreasing the artifact caused by endoprosthesis, frequently utilized in reconstruction of musculoskeletal tumor patients. Further installments of conventional imaging sequences with the addition of gadolinium - enhancement will enable increased accuracy in diagnosing local recurrences of sarcoma patients.


Assuntos
Artroplastia de Substituição/métodos , Artefatos , Neoplasias Ósseas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Próteses Articulares Metal-Metal , Neoplasias de Tecidos Moles/diagnóstico por imagem , Artroplastia de Substituição/instrumentação , Neoplasias Ósseas/cirurgia , Feminino , Humanos , Masculino , Próteses Articulares Metal-Metal/efeitos adversos , Radiografia , Estudos Retrospectivos , Neoplasias de Tecidos Moles/cirurgia
11.
J Shoulder Elbow Surg ; 23(9): e199-206, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24618195

RESUMO

BACKGROUND: Neovessels and accompanying nerves are possible sources of pain. We postulated that transcatheter arterial embolization of abnormal neovessels would relieve pain and symptoms in patients with adhesive capsulitis. METHODS: Adhesive capsulitis was treated by transcatheter arterial embolization in 7 patients. Adverse events, changes in visual analog scale scores for night pain and overall shoulder pain, and changes in range of motion and American Shoulder and Elbow Surgeons scores were assessed at 1 week and at 1, 3, and 6 months after the procedure. RESULTS: Abnormal neovessels were identified at the rotator interval in all patients. No major or minor adverse events were associated with the procedures. Transcatheter arterial embolization rapidly decreased nighttime pain scores from 67 ± 14 mm to 27 ± 14 mm at 1 week after the procedure, with further improvement at 1 and 6 months (6 ± 8 mm and 2 ± 5 mm, respectively). The American Shoulder and Elbow Surgeons score significantly improved from 17.8 ± 4.5 to 39.8 ± 12.0, 64.3 ± 13.9, and 76.2 ± 4.4 at 1, 3, and 6 months, respectively. CONCLUSION: All patients with adhesive capsulitis had abnormal neovessels at the rotator interval. Transcatheter arterial embolization was feasible, relieved unrelenting pain, and restored shoulder function.


Assuntos
Bursite/complicações , Embolização Terapêutica , Neovascularização Patológica/terapia , Dor de Ombro/terapia , Adulto , Idoso , Cateterismo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neovascularização Patológica/etiologia , Projetos Piloto , Estudos Prospectivos , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Articulação do Ombro/irrigação sanguínea , Dor de Ombro/etiologia
12.
Radiol Case Rep ; 19(8): 3483-3487, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38872742

RESUMO

We present a case of prophylactic endovascular embolization in a 51-year-old man with necrotizing pancreatitis (NP) before undergoing endoscopic necrosectomy (EN). Contrast-enhanced CT imaging revealed the presence of a walled-off necrosis (WON) surrounding the pancreas, with the splenic artery coursing through the cavity. The splenic artery was embolized using n-butyl-2-cyanoacrylate (NBCA) and coils to mitigate the risk of massive bleeding in EN. A newly developed polytetrafluoroethylene (PTFE)-coated microcatheter was used to inject NBCA, enabling embolization of a long segment of the splenic artery without adhering to the vessel wall. Coils were placed distal and proximal to the embolized segment to optimize control. Over 5 sessions of EN, no massive bleeding was encountered. This report demonstrates the benefits of utilizing PTFE-coated microcatheters for enhanced safety and maneuverability during embolization with NBCA. Furthermore, it highlights the importance of prophylactic embolization during EN for managing NP.

13.
Radiol Case Rep ; 19(6): 2112-2116, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38645534

RESUMO

We describe the endovascular embolization of a 65-year-old man with chronic hepatic encephalopathy. A contrast-enhanced computed tomography demonstrated a splenorenal shunt and a recanalized paraumbilical vein as a continuous portal shunt connecting the left branch of the portal vein and the right common femoral vein. A 2-session embolization was performed for the splenorenal shunt. First, the transvenous approach was used for coil embolization of the splenorenal shunt. It was difficult to advance the catheter system to the embolization site, and it was unstable during coil placement. Second, the paraumbilical venous approach was used to place additional coils. The catheter system had good maneuverability and easily reached the embolization site. Additionally, the stable system allowed for densely packed additional coil implantations. This report demonstrated the paraumbilical venous approach's effectiveness in catheter maneuverability and system stability during coil embolization.

14.
Jpn J Ophthalmol ; 68(4): 346-354, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38833074

RESUMO

PURPOSE: To evaluate the effectiveness and safety of selective ophthalmic arterial injection (SOAI) for retinoblastoma utilizing a microballoon catheter system with an M chamber. STUDY DESIGN: Retrospective analysis. METHODS AND PATIENTS: This study was sanctioned by theNational Cancer Center Hospital' Independent Ethics Committee. The surgeon was a general interventional radiologist. After confirming that the distal internal carotid artery was not delineated by balloon occlusion and the ophthalmic artery was visualized using digital subtraction angiography, melphalan was manually administered. Notably, in cases presenting bilateral retinoblastoma, both eyes received treatment in a singular, low-dose procedure. Between July 2015 and December 2021, 125 patients with retinoblastoma (68 boys and 57 girls) underwent SOAI at our facility. The average age at initial treatment was 19.3 months. The study covered 250 procedures, with patients undergoing an average of 3.7 procedures. RESULTS: The success rate of the procedure was 99.2%, with a mean procedure duration of 18.3 min. Two distinct technical failures were recorded: one attributed to an internal carotid artery having a wide lumen and the other due to the ophthalmic artery remaining undetected on angiography post-balloon occlusion of the internal carotid artery. Adverse events were minimal but included bronchospasm post-procedure and severe orbital inflammation in 0.8% and 0.4% of cases, respectively. CONCLUSION: SOAI using the microballoon catheter with the M chamber is a feasible and safe procedure for the treatment of retinoblastoma. The success rate was 99.2%. This system can be recommended as intra-arterial chemotherapy for retinoblastoma.


Assuntos
Injeções Intra-Arteriais , Melfalan , Artéria Oftálmica , Neoplasias da Retina , Retinoblastoma , Humanos , Retinoblastoma/terapia , Retinoblastoma/diagnóstico , Retinoblastoma/tratamento farmacológico , Artéria Oftálmica/diagnóstico por imagem , Neoplasias da Retina/terapia , Neoplasias da Retina/tratamento farmacológico , Neoplasias da Retina/diagnóstico , Estudos Retrospectivos , Feminino , Masculino , Lactente , Pré-Escolar , Melfalan/administração & dosagem , Angiografia Digital , Resultado do Tratamento , Seguimentos , Antineoplásicos Alquilantes/administração & dosagem , Criança
15.
J Endocr Soc ; 8(6): bvae080, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38715590

RESUMO

Context: Detecting patients with surgically curable aldosterone-producing adenoma (APA) among hypertensive individuals is clinically pivotal. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is the ideal method of measuring plasma aldosterone concentration (PAC) because of the inaccuracy of conventional chemiluminescent enzyme immunoassay (CLEIA). However, LC-MS/MS is expensive and requires expertise. We have developed a novel noncompetitive CLEIA (NC-CLEIA) for measuring PAC in 30 minutes. Objective: This work aimed to validate NC-CLEIA PAC measurements by comparing them with LC-MS/MS measurements and determining screening cutoffs for both measurements detecting APA. Methods: We retrospectively measured PAC using LC-MS/MS and NC-CLEIA in 133 patients with APA, 100 with bilateral hyperaldosteronism, and 111 with essential hypertension to explore the accuracy of NC-CLEIA PAC measurements by comparing with LC-MS/MS measurements and determined the cutoffs for detecting APA. Results: Passing-Bablok analysis revealed that the values by NC-CLEIA (the regression slope, intercept, and correlation coefficient were 0.962, -0.043, and 0.994, respectively) were significantly correlated and equivalent to those by LC-MS/MS. Bland-Altman plot analysis of NC-CLEIA and LC-MS/MS also demonstrated smaller systemic errors (a bias of -0.348 ng/dL with limits of agreement of -4.390 and 3.694 within a 95% CI) in NC-CLEIA than LC-MS/MS. The receiver operating characteristic analysis demonstrated that cutoff values for aldosterone/renin activity ratio obtained by LC-MS/MS and NC-CLEIA were 31.2 and 31.5 (ng/dL per ng/mL/hour), with a sensitivity of 91.0% and 90.2% and specificity of 75.4% and 76.8%, respectively, to differentiate APA from non-APA. Conclusion: This newly developed NC-CLEIA for measuring PAC could serve as a clinically reliable alternative to LC-MS/MS.

16.
Hypertens Res ; 47(5): 1362-1371, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38454147

RESUMO

The measurement evolution enabled more accurate evaluation of aldosterone production in hypertensive patients. However, the cut-off values for novel assays have been not sufficiently validated. The present study was undertaken to validate the novel chemiluminescent enzyme immunoassay for aldosterone in conjunction with other methods. Moreover, we also aimed to establish a new cut-off value for primary aldosteronism in the captopril challenge test using the novel assay. First, we collected 390 plasma samples, in which aldosterone levels measured using liquid chromatography-mass spectrometry ranged between 0.18 and 1346 ng/dL. The novel chemiluminescent enzyme immunoassay showed identical correlation of plasma aldosterone with liquid chromatography-mass spectrometry, in contrast to conventional radioimmunoassay. Further, we enrolled 299 and 39 patients with primary aldosteronism and essential hypertension, respectively. Plasma aldosterone concentrations measured using the novel assay were lower than those measured by radioimmunoassay, which resulted in decreased aldosterone-to-renin ratios. Subsequently, positive results of the captopril challenge test based on radioimmunoassay turned into "negative" based on the novel assay in 45% patients with primary aldosteronism, using the conventional cut-off value (aldosterone-to-renin activity ratio > 20 ng/dL per ng/mL/h). Receiver operating characteristic curve analysis demonstrated that aldosterone-to-renin activity ratios > 8.2 ng/dL per ng/mL/h in the novel assay was compatible with the conventional diagnosis (sensitivity, 0.874; specificity, 0.980). Our study indicates the great measurement accuracy of the novel chemiluminescent enzyme immunoassay for aldosterone, and the importance of measurement-adjusted cut-offs in the diagnosis of primary aldosteronism.


Assuntos
Aldosterona , Captopril , Hiperaldosteronismo , Medições Luminescentes , Humanos , Hiperaldosteronismo/diagnóstico , Hiperaldosteronismo/sangue , Masculino , Feminino , Pessoa de Meia-Idade , Aldosterona/sangue , Estudos Retrospectivos , Adulto , Idoso , Medições Luminescentes/métodos , Técnicas Imunoenzimáticas/métodos , Hipertensão/sangue , Hipertensão/diagnóstico , Renina/sangue , Estudos de Coortes , Radioimunoensaio
17.
J Vasc Interv Radiol ; 24(6): 787-92, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23707086

RESUMO

PURPOSE: To evaluate the feasibility and effects of transcatheter arterial embolization with imipenem/cilastatin sodium (CS) to treat tendinopathy and enthesopathy that are refractory to traditional nonsurgical management. MATERIALS AND METHODS: Transcatheter arterial embolization with imipenem/CS as an embolic agent was performed in seven patients (five men; mean age, 51.7 y) with tendinopathy and enthesopathy (patellar tendinopathy, n = 1; rotator cuff tendinopathy, n = 2; plantar fasciitis, n = 1; lateral epicondylitis, n = 1; iliotibial band syndrome, n = 1; and Achilles insertion tendinopathy, n = 1). All patients had unrelenting pain at the site of tendinopathy and enthesopathy before the procedure. Technical success, adverse events, and changes in visual analog scale (VAS) scores were assessed. RESULTS: All procedures were technically successful, and no major adverse events developed. Compared with before the procedure, mean VAS scores were significantly decreased at 1 day, 1 week, and 1 and 4 months after the procedure (72.7 mm±9.9 vs 17.4 mm±18.5, 16.0 mm±18.1, 13.7 mm±7.3, and 9.7 mm±6.8, respectively; all P< .001). CONCLUSIONS: Transcatheter arterial embolization with imipenem/CS was feasible and effectively relieved unrelenting pain associated with tendinopathy and enthesopathy.


Assuntos
Artralgia/tratamento farmacológico , Cateterismo Periférico/métodos , Cilastatina/administração & dosagem , Embolização Terapêutica/métodos , Hemostáticos/administração & dosagem , Imipenem/administração & dosagem , Doenças Reumáticas/tratamento farmacológico , Tendinopatia/tratamento farmacológico , Adulto , Idoso , Antibacterianos/administração & dosagem , Artralgia/diagnóstico , Artralgia/etiologia , Doença Crônica , Combinação Imipenem e Cilastatina , Combinação de Medicamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor/efeitos dos fármacos , Inibidores de Proteases/administração & dosagem , Doenças Reumáticas/complicações , Doenças Reumáticas/diagnóstico , Tendinopatia/complicações , Tendinopatia/diagnóstico , Resultado do Tratamento
18.
Radiol Case Rep ; 18(5): 1973-1977, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36970241

RESUMO

Endovascular therapy is an important method of treating high-flow arteriovenous malformations (AVMs). The nidus of AVMs can be treated by transarterial or percutaneous approaches with the use of ethanol as a strong embolic agent; however, treatment outcomes are not always satisfactory and complications including skin necrosis often occur, particularly following the treatment of superficial lesions. Herein, we describe successful transvenous sclerotherapy of high-flow AVMs in the finger of a 47-year-old female patient that were causing erythema and spontaneous pain using ethanolamine oleate (EO) as a safe sclerosant. Dynamic contrast-enhanced computed tomography and angiography revealed a high-flow type Ⅲb AVM according to Yakes classification. Using the transvenous approach, 5% EO with idoxanol was injected into the nidus of the AVM 3 times over 2 sessions. An arterial tourniquet was used to achieve stasis of blood flow at the nidus and microballoon occlusion of the outflow vein was used to ensure the sclerosant effectively reached the nidus. Near-total occlusion of the nidus was achieved leading to improved symptoms. Mild edema lasting 2 weeks occurred as a minor reaction after each session. Finger amputation may have been avoided by using this treatment. Transvenous EO sclerotherapy using an arterial tourniquet and balloon occlusion may have utility in treating AVMs in the extremities.

19.
BJR Case Rep ; 9(6): 20220116, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37928699

RESUMO

Postoperative portal vein obstruction could occur as a complication of portal vein reconstruction during hepatic lobectomy or pancreaticoduodenectomy. We report a case of patient with postoperative portal vein obstruction treated with percutaneous transhepatic portal vein stenting without using iodinated contrast media owing to a history of severe allergic reactions. Under ultrasound guidance, carbon dioxide angiography, and appropriate device selection, successful stenting was achieved without serious adverse events. After the operation, portal vein blood flow and clinical symptoms improved, enabling adjuvant chemotherapy. To the best of our knowledge, this is the first case report wherein percutaneous transhepatic portal vein stenting was successfully performed in a patient with an iodine allergy.

20.
Cardiovasc Intervent Radiol ; 46(12): 1666-1673, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37973663

RESUMO

PURPOSE: To describe a novel technique of transvenous radiofrequency catheter ablation of an aldosterone-producing adenoma (APA) of the left adrenal gland using the GOS System (Japan Lifeline, Tokyo, Japan). Using the GOS system, a flexible radiofrequency tip catheter can be inserted into the adrenal central and tributary veins, the drainers for functional tumors. MATERIALS AND METHODS: An APA at the left adrenal gland, which was diagnosed by segmental adrenal venous sampling following administration of 0.25 mg cosyntropin, was ablated using the GOS catheter inserted into adrenal tributary veins via a right femoral vein 7-Fr sheath. The effect of radiofrequency ablation on APA was assessed using the international consensus on surgical outcomes for unilateral primary aldosteronism (PA). RESULTS: No device-related complications were observed. The patient was deeply sedated under blood pressure and heart rate control with continuous administration of ß-blockers. Then, the tumor and surrounding adrenal gland were cauterized at 7000 J two times each in sequence. The output time was 7-11 min for each ablation and 80 min in total. For blood pressure and pulse rate control, esmolol hydrochloride and phentolamine mesylate were used. The contrast enhancement of APA disappeared on dynamic CT immediately after the procedure. PA was biochemically cured until 12 months after the procedure. CONCLUSION: Using the radiofrequency device with the GOS catheter and system is a method for cauterizing adrenal tumors from blood vessels. This approach resulted in a marked reduction in aldosterone concentrations and a complete biochemical cure of PA over the observation period.


Assuntos
Neoplasias das Glândulas Suprarrenais , Ablação por Cateter , Hiperaldosteronismo , Humanos , Aldosterona , Glândulas Suprarrenais/diagnóstico por imagem , Glândulas Suprarrenais/cirurgia , Glândulas Suprarrenais/irrigação sanguínea , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Neoplasias das Glândulas Suprarrenais/cirurgia , Catéteres/efeitos adversos , Ablação por Cateter/métodos , Hiperaldosteronismo/etiologia , Hiperaldosteronismo/cirurgia , Hiperaldosteronismo/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA