Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nanomedicine ; 12(4): 1045-1052, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26733255

RESUMO

The magnetic technique for sentinel node biopsy provides a radioisotope-free alternative for staging breast cancer. It requires refinement to reduce "residual iron content" at injection sites by maximising lymphatic uptake to prevent "void artefacts" on magnetic resonance imaging (MRI), which could adversely affect clinical use. The site and timing of injection of magnetic tracer was evaluated in a murine tumour model (right hind limb) in 24 wild type mice. Right-sided intratumoural and left sided subcutaneous injection of magnetic tracer and assessment of nodal iron uptake on MRI, surgical excision and histopathological grading at time frames up to 24 hours were performed. Rapid iron uptake on MRI, smaller "void artefacts"(P<0.001) and a significant increase in iron content with time were identified in the subcutaneous injection group (r=0.937; P<0.001).Subcutaneous injection and increasing delay between tracer injection and surgery is beneficial for lymphatic iron uptake. FROM THE CLINICAL EDITOR: Sentinel lymph node biopsy (SLNB) has been the standard of care in breast cancer management for some time. Recent development has seen the introduction of magnetic tracer for SLNB. In this article, the authors investigated the refined use of magnetic tracer in determining the optimal timing of administration and the location of injection. The findings should provide more data on the future use of this new technique.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Meios de Contraste/efeitos adversos , Nanopartículas de Magnetita/efeitos adversos , Animais , Neoplasias da Mama/patologia , Modelos Animais de Doenças , Feminino , Humanos , Imageamento por Ressonância Magnética , Camundongos , Linfonodo Sentinela/efeitos dos fármacos , Linfonodo Sentinela/patologia , Biópsia de Linfonodo Sentinela
2.
Cancers (Basel) ; 13(19)2021 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-34638516

RESUMO

The magnetic technique, consisting of a magnetic tracer and a handheld magnetometer, is a promising alternative technique for sentinel lymph node dissection (SLND) and was shown to be non-inferior to the standard technique in terms of identification rates. In this study, injection characteristics (iron dose, dilution, time course and massaging) were evaluated to optimize magnetic tracer uptake in the sentinel lymph nodes (SLN) in a rat hindleg model. 202 successful SLNDs were performed. Iron uptake in the SLN is proportional (10% utilization rate) to the injection dose between 20 and 200 µg, showing a plateau uptake of 80 µg in the SLN around 1000 µg injection. Linear regression showed that time had a higher impact than dilution, on the SLN iron uptake. Massaging showed no significant change in iron uptake. The amount of residual iron at the injection site was also proportional to the injection dose without any plateau. Time was a significant factor for wash-out of residual iron. From these results, preoperative injection may be advantageous for SLN detection as well as reduction in residual iron at the injection site by potential decrease in required injection dose.

3.
Sci Rep ; 8(1): 1195, 2018 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-29352214

RESUMO

The newly developed radioisotope-free technique based on magnetic nanoparticle detection using a magnetic probe is a promising method for sentinel lymph node biopsy. In this study, a novel handheld magnetic probe with a permanent magnet and magnetic sensor is developed to detect the sentinel lymph nodes in breast cancer patients. An outstanding feature of the probe is the precise positioning of the sensor at the magnetic null point of the magnet, leading to highly sensitive measurements unaffected by the strong ambient magnetic fields of the magnet. Numerical and experimental results show that the longitudinal detection length is approximately 10 mm, for 140 µg of iron. Clinical tests were performed, for the first time, using magnetic and blue dye tracers-without radioisotopes-in breast cancer patients to demonstrate the performance of the probe. The nodes were identified through transcutaneous and ex-vivo measurements, and the iron accumulation in the nodes was quantitatively revealed. These results show that the handheld magnetic probe is useful in sentinel lymph node biopsy and that magnetic techniques are widely being accepted as future standard methods in medical institutions lacking nuclear medicine facilities.


Assuntos
Técnicas Biossensoriais , Neoplasias da Mama/diagnóstico , Nanopartículas de Magnetita , Biópsia de Linfonodo Sentinela/métodos , Linfonodo Sentinela/patologia , Ensaios Clínicos como Assunto , Corantes , Feminino , Compostos Férricos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA