Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
Clin Oral Investig ; 28(6): 356, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834721

RESUMO

OBJECTIVES: This ex-vivo study aimed to assess the influence of tube current (mA) and metal artifact reduction (MAR) on the diagnosis of early external cervical resorption (EECR) in cone-beam computed tomography (CBCT) in the presence of an adjacent dental implant. MATERIALS AND METHODS: Twenty-three single-rooted teeth were sectioned longitudinally and EECR was induced using a spherical drill and 5% nitric acid in 10 teeth. Each tooth was positioned in the socket of the lower right canine of a dry human mandible and CBCT scans were acquired using 90 kVp, voxel of 0.085 mm, field of view of 5 x 5 cm, and varying tube current (4, 8 or 12 mA), MAR (enabled or disabled) and implant conditions (with a zirconia implant in the socket of the lower right first premolar or without). Five oral radiologists evaluated the presence of EECR in a 5-point scale and the diagnostic values (area under the receiver operating characteristic curve - AUC, sensitivity, and specificity) were compared using multi-way Analysis of Variance (α = 0.05). Kappa test assessed intra-/inter-evaluator agreement. RESULTS: The tube current only influenced the AUC values in the presence of the implant and when MAR disabled; in this case, 8 mA showed lower values (p<0.007). MAR did not influence the diagnostic values (p>0.05). In general, the presence of an implant reduced the AUC values (p<0.0001); sensitivity values with 8 mA and MAR disabled, and specificity values with 4 mA and MAR enabled and 8 mA regardless MAR were also decreased (p<0.0001). CONCLUSIONS: Variations in tube current and MAR were unable to improve EECR detection, which was impaired by the presence of an adjacent implant. CLINICAL RELEVANCE: Increasing tube current or activating MAR tool does not improve EECR diagnosis, which is hampered by the artifacts generated by dental implants.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Técnicas In Vitro , Implantes Dentários , Sensibilidade e Especificidade , Metais , Mandíbula/diagnóstico por imagem , Reabsorção da Raiz/diagnóstico por imagem , Reabsorção da Raiz/etiologia
2.
Clin Oral Investig ; 28(3): 204, 2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38459362

RESUMO

OBJECTIVES: To evaluate the performance of a commercially available Generative Pre-trained Transformer (GPT) in describing and establishing differential diagnoses for radiolucent lesions in panoramic radiographs. MATERIALS AND METHODS: Twenty-eight panoramic radiographs, each containing a single radiolucent lesion, were evaluated in consensus by three examiners and a commercially available ChatGPT-3.5 model. They provided descriptions regarding internal structure (radiodensity, loculation), periphery (margin type, cortication), shape, location (bone, side, region, teeth/structures), and effects on adjacent structures (effect, adjacent structure). Diagnostic impressions related to origin, behavior, and nature were also provided. The GPT program was additionally prompted to provide differential diagnoses. Keywords used by the GPT program were compared to those used by the examiners and scored as 0 (incorrect), 0.5 (partially correct), or 1 (correct). Mean score values and standard deviation were calculated for each description. Performance in establishing differential diagnoses was assessed using Rank-1, -2, and - 3. RESULTS: Descriptions of margination, affected bone, and origin received the highest scores: 0.93, 0.93, and 0.87, respectively. Shape, region, teeth/structures, effect, affected region, and nature received considerably lower scores ranging from 0.22 to 0.50. Rank-1, -2, and - 3 demonstrated accuracy in 25%, 57.14%, and 67.85% of cases, respectively. CONCLUSION: The performance of the GPT program in describing and providing differential diagnoses for radiolucent lesions in panoramic radiographs is variable and at this stage limited in its use for clinical application. CLINICAL RELEVANCE: Understanding the potential role of GPT systems as an auxiliary tool in image interpretation is imperative to validate their clinical applicability.


Assuntos
Diagnóstico Diferencial , Radiografia Panorâmica , Consenso
3.
J Oral Rehabil ; 51(3): 517-525, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37941125

RESUMO

BACKGROUND: There is no established protocol for the low doses of cone-beam computed tomography (CBCT) acquisition and filter application on the diagnosis of condylar morphological alterations. OBJECTIVES: The objective of the study was to evaluate the influence of voxel size and filter application on the diagnosis of condylar morphological alterations in CBCT using an ex vivo model. METHODS: CBCT scans of 36 temporomandibular joints were acquired using OP300 Maxio with voxel sizes of 0.085, 0.125 and 0.280 mm. Three radiologists evaluated the condyles in the CBCT volumes under three filter modes: no filter, '1x' sharpen filter and '2x' sharpen filter. The area under the ROC curve, sensitivity and specificity were calculated by comparing the evaluators' responses with the reference standard and compared among experimental groups using analysis of variance (ANOVA) (α = 5%). RESULTS: The area under the ROC curve, sensitivity and specificity were not affected by voxel size and filter application (p > .05). For osteophyte and flattening, there were more true-positive responses in smaller voxel size. For erosion, the increase of true- and false-positive responses occurred with a larger voxel size. Overall, there was a tendency to decrease true positives for osteophyte and erosion and increase false positives for flattening with the '2x' sharpen filter. CONCLUSIONS: The diagnosis of condylar morphological alterations assessed in this ex vivo analysis is not influenced by the voxel size and the application of the filters. However, attention is needed with the occurrence of false-positive diagnosis with a larger voxel size for erosion and '2x' sharpen filter for flattening.


Assuntos
Osteófito , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Sensibilidade e Especificidade , Tomografia Computadorizada de Feixe Cônico/métodos , Osso e Ossos
4.
J Anat ; 243(2): 334-341, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36932846

RESUMO

The objective of this study was to better understand human variation by comparing cone-beam computed tomography-based cranial measurements between both sexes of individuals from two distinct populations: Brazilian and Dutch. Cone-beam computed tomography volumes of 311 patients between 20 and 60 years from Brazil and The Netherlands were selected. Two radiologists performed 16 linear measurements in the maxillary sinuses and mandibular canal. Kruskall-Wallis test compared measurements of the two cranial structures between male and female for the two populations and four age ranges (20-30, 31-40, 41-50, 51-60). Mann-Whitney test compared individual measurements obtained from the cranial structures between male and female for each population, and between both populations for both sexes. Intra- and inter-observer reliability was assessed by intraclass correlation test (α = 0.05). No significant differences were found in the linear measurements among the experimental groups including sex, population and age group for both cranial structures (p > 0.05). Most of the cranial linear measurements were significantly higher for male than those for female irrespective of the population (p ≤ 0.05). When the populations were compared regardless of sex, Brazilians presented four significantly higher measurements, and Dutch presented seven significantly higher measurements (p ≤ 0.05). The assessed cranial structures did not differ between Brazilian and Dutch populations for both sexes and four age ranges. Multiple linear measurements differed between both populations with a predominance of larger dimensions for the Dutch population.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Crânio , Humanos , Masculino , Feminino , Brasil , Países Baixos , Reprodutibilidade dos Testes , Crânio/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Mandíbula
5.
J Bone Miner Metab ; 41(5): 727-737, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37432542

RESUMO

INTRODUCTION: Studies have shown that an impaired bone condition, represented by osteoporosis and increased fracture risk, may potentially aggravate periodontal disease and, consequently, the risk of tooth loss. This 5-year prospective study aimed to investigate whether systemic bone condition represents risk factor for tooth loss due to periodontal disease amongst elderly women. MATERIAL AND METHODS: Seventy-four participants, aged ≥ 65 years, who attended the 5-years recall for periodontal evaluation were involved. Baseline exposures were osteoporosis and fracture risk probabilities (FRAX). Women were grouped according to bone mineral density (BMD) and years of bone treatment for osteoporosis. The primary outcome at a 5-year follow-up was the number of tooth loss due to periodontal disease. Periodontitis staging and grading, and causes of tooth loss were recorded. RESULTS: The multivariate Poisson regression models showed that women with untreated/shortly treated osteoporosis were 4 times more likely to present higher number of tooth loss due to periodontal disease than those with normal BMD or treated for ≥ 3 years (risk ratio (RR) = 4.00, 95% CI 1.40-11.27). Higher FRAX was also linked to tooth loss (RR = 1.25, 95% CI 1.02-1.53). Receiver-operating characteristic (ROC) curve suggested that women with history of ≥ 1 tooth losses have higher chances of worse major FRAX (sensitivity = 72.2%; specificity = 72.2%). CONCLUSION: In this 5-year study, higher FRAX and untreated osteoporosis were risk factors for tooth loss. Women with normal BMD or treated for osteoporosis for ≥ 3 years did not show increased risk. Management of skeletal conditions should be emphasized with periodontal care for the prevention of tooth loss in elderly women.


Assuntos
Fraturas Ósseas , Osteoporose , Fraturas por Osteoporose , Doenças Periodontais , Perda de Dente , Idoso , Feminino , Humanos , Perda de Dente/complicações , Perda de Dente/epidemiologia , Estudos Prospectivos , Osteoporose/epidemiologia , Osteoporose/complicações , Densidade Óssea , Fraturas Ósseas/complicações , Fatores de Risco , Doenças Periodontais/complicações , Medição de Risco , Fraturas por Osteoporose/etiologia , Absorciometria de Fóton
6.
J Prosthet Dent ; 129(5): 741-747, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-34399992

RESUMO

STATEMENT OF PROBLEM: Knowledge about the location and dimensions of the mental foramen is important for surgical planning and implant placement in the posterior mandibular region. PURPOSE: The purpose of this clinical study was to assess the location and dimensions of the mental foramen in individuals of different facial type, skeletal class, and sex by means of cone beam computed tomography (CBCT) images. MATERIAL AND METHODS: CBCT images of 142 individuals (72 women and 70 men) were classified according to the facial type (dolichocephalic, mesocephalic, or brachycephalic) and skeletal class (I, II, or III). The vertical and horizontal locations of each mental foramen were evaluated on panoramic reconstructions, and the greatest height and width of the mental foramen were determined on multiplanar reconstructions. Also, the distances from the mental foramen to the alveolar crest and to the inferior cortex of the mandible were obtained. The data were compared by using the Kruskal-Wallis test and multiway analysis of variance (α=.05). RESULTS: The facial type, skeletal class, and sex did not influence the vertical (P=1.00) or the horizontal (P>.15) location of the mental foramen. The most frequent location of the mental foramen was between the first and second premolars and below their apices. The dimensions of the mental foramen were not influenced by the studied factors in men (P>.07); conversely, the mental foramen dimensions were influenced for women (P<.03). CONCLUSIONS: The most frequent location of the mental foramen was between the first and second premolars and below their apices. An influence of the facial type and skeletal class was observed on the dimensions of the mental foramen in women.


Assuntos
Forame Mentual , Tomografia Computadorizada de Feixe Cônico Espiral , Masculino , Humanos , Feminino , Mandíbula/diagnóstico por imagem , Face/diagnóstico por imagem , Processo Alveolar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos
7.
An Acad Bras Cienc ; 94(2): e20201163, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35830080

RESUMO

Peanuts are an important legume for the Northeastern Brazilian market, but their production in this region is low. The present study aimed to evaluate the effect of biofertilizer doses on peanut nodulation and production components, to define the best dose and genotype. The experiment was conducted in a completely randomized block design (DBC) in a 3 x 3 factorial arrangement, with three replications. The treatments consisted of two evaluation factors: 1) Fertilization via different doses of organic fertilizer applied to the substrate (D1 = 0mL; D2 = 500mL; and D3 = 1000mL); and 2) Peanut genotypes (BR-1, UNI43 and UNI08). The following traits were assessed: number of nodules per plant (NNP), number of mature pods (NVM), pod mass per plant (MVP), seed mass per plant (MSP) and root length (CR). Peanut production is affected by fertilization via bovine biofertilizer, mainly for the components NVM, MVP and MSP. Besides, nodulation is a likely conditioner. The 1000mL dose proved to be the best treatment for the traits analyzed, and UNI08 accession, the most responsive material.


Assuntos
Arachis , Fertilizantes , Animais , Bovinos , Arachis/genética , Brasil , Genótipo , Sementes
8.
Clin Oral Investig ; 26(7): 4797-4803, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35288809

RESUMO

OBJECTIVES: To evaluate the influence of sharpening filters in the detection of root fractures using low-dose cone-beam computed tomography (CBCT). MATERIALS AND METHODS: Eighty-four CBCT volumes acquired at three mA levels of 28 teeth inserted in the dental socket of dry human skull were selected from a previous study. The teeth were divided into four groups according to the presence and absence of root fracture and endodontic filling. Five radiologists evaluated all CBCT volumes for the presence of root fracture with and without the application of "Sharpen 1x" and "Sharpen 2x" filters in OnDemand3D software. Area under the ROC curve (AUC), sensitivity, specificity, and inter- and intra-observer concordance were calculated and compared (α = 0.05). RESULTS: Sharpening filters did not lead to significant differences in AUC, sensitivity, and specificity at the three mA levels tested (p > 0.05), regardless of the presence of endodontic filling (p > 0.05). However, the significant reduction of AUC observed in CBCT volumes at 4 mA without filter (p < 0.05) ceased to exist after the application of filters (p > 0.05). Sensitivity and specificity ranged from low and moderate. CONCLUSIONS: The use of sharpening filters can be recommended in CBCT volumes at 4 mA for root fracture detection for leading to the same performance as those at 6.3 and 10 mA. The presence of endodontic filling material did not influence the action of filters in the diagnosis of root fracture. CLINICAL RELEVANCE: Sharpening filters seem to contribute to the diagnosis of root fracture in CBCT volumes acquired with reduced radiation dose.


Assuntos
Fraturas Ósseas , Fraturas dos Dentes , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Sensibilidade e Especificidade , Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem
9.
Clin Oral Investig ; 26(6): 4457-4466, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35166942

RESUMO

OBJECTIVES: The overall objective of this study was to assess how metal artefacts impact image quality of 13 CBCT devices. As a secondary objective, the influence of scanning protocols and field of view on CBCT image quality with and without metal artefacts was also assessed. MATERIALS AND METHODS: CBCT images were acquired of a dry human skull phantom considering three clinical simulated conditions: one without metal and two with metallic materials (metallic pin and implant). An industrial micro-CT was used as a reference to register the CBCT images. Afterwards, four observers evaluated 306 representative image slices from 13 devices, ranking them from best to worst. Furthermore, within each device, medium FOV and small FOV standard images were compared. General linear mixed models were used to assess subjective perception of examiners on overall image quality in the absence and presence of metal-related artefacts (p < 0.05). RESULTS: Image quality perception significantly differed amongst CBCT devices (p < 0.05). Some devices performed significantly better, independently of scanning protocol and clinical condition. In the presence of metal artefacts, medium FOV standard scanning protocols scored significantly better, while in the absence of metal, small FOV standard yielded the highest performance. CONCLUSIONS: Subjective image quality differs significantly amongst CBCT devices and scanning protocols. Metal-related artefacts may highly impact image quality, with a significant device-dependent variability and only few scanners being more robust against metal artefacts. Often, metal artefact expression may be somewhat reduced by proper protocol selection. CLINICAL RELEVANCE: Metallic objects may severely impact image quality in several CBCT devices.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico Espiral , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Metais , Percepção , Imagens de Fantasmas
10.
Clin Oral Investig ; 26(8): 5105-5116, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35618962

RESUMO

AIM: To evaluate the influence of root canal filling quality on periapical lesion status using cone-beam computed tomography (CBCT). MATERIALS AND METHODS: The bibliographic search was conducted in electronic databases of PubMed, Embase, Scopus, and Web of Science without restrictions related to the year of publication and language. Inclusion criteria were prospective or retrospective cohort studies that followed periapical pathosis for, at least, 1 year. Three reviewers independently evaluated the eligibility for inclusion, extracted data, and assessed the risk of bias. The quality of the studies was based on the Newcastle-Ottawa Scale. This meta-analysis was performed to evaluate the quality of treatment by the homogeneity and apical extension of the filling. RESULTS: Of the 1179 studies initially recovered, six cohort studies were included, out of which four were considered with a low risk of bias. The results showed that the absence of gaps in the filling reduced the chance of unhealed periapical lesions by 2.39 times (RR = 2.39; 95% CI: 1.62-3.53; p < 0.00001; I2 = 55%). An apical filling extension of 0-2 mm below the apex also contributed significantly to the absence of unhealed periapical lesions (RR = 1.49; 95% CI: 1.15-1.94; p = 0.003; I2 = 2%). CONCLUSION: The homogeneity and apical extension of the filling influenced the presence of unhealed periapical lesions in endodontically treated teeth evaluated using CBCT. CLINICAL RELEVANCE: Apical extension of the filling ranging between 0 and 2 mm short of the apical foramen and the homogeneity of the filling without gaps are directly related to the success rate of root canal treatment.


Assuntos
Cavidade Pulpar , Periodontite Periapical , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Periodontite Periapical/terapia , Estudos Prospectivos , Estudos Retrospectivos , Tratamento do Canal Radicular/métodos
11.
Sensors (Basel) ; 22(22)2022 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-36433224

RESUMO

The aim of this study is to quantitatively evaluate the influence of the duration of ambient light exposure on the image quality of digital radiographs obtained with contemporary phosphor plate (PSP)-based systems. Radiographs of an aluminum step-wedge were obtained using VistaScan and Express systems at five X-ray exposure times: 0.10, 0.20, 0.32, 0.40, and 0.50 s; the resulting dose-area products were, respectively, 21.93, 43.87, 70.19, 87.75, and 109.6 mGycm2. Before PSP read-out, half of the sensitive surface of the PSP plates was exposed to ambient light for 5, 10, 30, 60, and 90 s. The effect of light exposure on brightness, contrast, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and image saturation was compared using ANOVA with the Tukey test (α = 0.05). Ambient light exposure increased brightness and contrast and reduced CNR and SNR in PSP-based radiographs of contemporary digital systems. At the longest X-ray exposure times, ambient light exposure reduced the dark saturation (mean gray values ≤ 1) observed in Express. In conclusion, the negative effects of ambient light observed on the image quality of PSP-based radiographs are directly proportional to the duration of exposure. Clinicians should be aware of such harmful effects when handling and scanning PSP plates in bright environments.


Assuntos
Placas Ósseas , Radiografia Dentária Digital , Radiografia Dentária Digital/métodos , Razão Sinal-Ruído
12.
Clin Oral Investig ; 25(8): 4941-4948, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33495894

RESUMO

OBJECTIVES: To evaluate the influence of different image file formats of digital radiographic images on the diagnosis of external (ERR) and internal root resorption (IRR). MATERIALS AND METHODS: Thirty-four human teeth were selected. For ERR, 20 teeth were used (10 control and 10 with simulated ERR), and for IRR, 14 teeth were used (before and after IRR simulation). Digital periapical radiographs were acquired using the Digora Toto system and exported in four different image file formats: TIFF, BMP, PNG, and JPEG, totaling 192 radiographs. Five examiners evaluated the images using the JPEGView software and scored the detection of ERR or IRR on a 5-point scale. Sensitivity, specificity, accuracy, and the area under the ROC curve were obtained for the diagnosis of ERR and IRR in the different image file formats. Two-way ANOVA compared the diagnostic values between the file formats and the Kappa test assessed intra- and inter-examiner agreement. The significance level was set at 5% (α = 0.05). RESULTS: The mean values of intra-examiner agreement were substantial (0.740) for ERR and almost perfect (0.836) for IRR and, inter-examiner was fair (0.263) and moderate (0.421), respectively. No statistically significant differences were found among the different file formats for the diagnostic values of ERR and IRR. CONCLUSION: The file format of digital radiographs does not influence the diagnosis of ERR and IRR. CLINICAL RELEVANCE: Digital radiographic images may be susceptible to computational factors; however, they can be stored in multiple file formats without affecting the diagnosis of dental root resorptions.


Assuntos
Reabsorção da Raiz , Humanos , Radiografia Dentária Digital , Reabsorção da Raiz/diagnóstico por imagem
13.
Clin Oral Investig ; 25(1): 195-202, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32506327

RESUMO

OBJECTIVES: To evaluate the effect of enhancement tools of intraoral digital radiographs on the assessment of vertical root fracture (VRF) and to quantify the resultant image noise. MATERIALS AND METHODS: Thirty single-rooted human teeth (15 control and 15 fractured) were each radiographed in four intracanal conditions: no filling, gutta-percha, metal post, and fiberglass post, totaling 120 original images. Two filters were applied to the original images-Sharpen filter (SF) and Edge Enhancement filter (EE), and brightness and contrast were adjusted in four combinations (B&C1 to 4), resulting in 840 images. Five oral radiologists analyzed the images for VRF detection. Pixel intensity was obtained in two regions from the radiographs. Diagnostic values were calculated and compared by two-way ANOVA, and the SD values of pixel intensity values were compared by one-way ANOVA (α = 0.05). RESULTS: There were no significant differences in accuracy for VRF detection between the experimental groups (p > 0.05). Teeth with metal post presented the lowest sensitivity (p < 0.05) for all experimental conditions, except for SF and EE (p > 0.05). B&C2, B&C3, and B&C4 had higher specificity than SF (p ≤ 0.05) for all intracanal conditions. Analysis of pixel intensity showed that all enhanced images presented statistically significant higher noise compared to those of the original images (p ≤ 0.05). CONCLUSION: Digital enhancement tools in digital radiography increase image noise; however, they can be used without compromising VRF detection. CLINICAL RELEVANCE: The use of digital enhancement does not impair the detection of VRF and, therefore, can be applied for this purpose according to the observer preference.


Assuntos
Fraturas dos Dentes , Tomografia Computadorizada de Feixe Cônico , Guta-Percha , Humanos , Radiografia Dentária Digital , Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem
14.
Clin Oral Investig ; 25(2): 637-643, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32845471

RESUMO

OBJECTIVES: To compare the overall diagnostic performance of digital panoramic radiographs obtained with low-dose protocols and to estimate the absorbed dose in the head and neck. MATERIALS AND METHODS: Forty-eight panoramic radiographs were obtained from eight imaging phantoms using six exposure protocols of progressively lower tube voltages (kVp) and currents (mA), as follows: (1) 70 kVp and 12.5 mA, (2) 66 kVp and 10 mA, (3) 66 kVp and 8 mA, (4) 66 kVp and 5 mA, (5) 66 kVp and 4 mA and (6) 66 kVp and 3.2 mA. Five oral radiologists independently evaluated the images and reported all detectable radiographic findings. Intra-examiner reproducibility was assessed by re-evaluation of 25% of the images. The data were analysed using the McNemar and weighted Kappa tests. Absorbed doses of the six protocols were obtained from thermoluminescent dosimeters placed inside a Rando phantom and compared using one-way ANOVA with post hoc Tukey (α = 0.05). RESULTS: The overall diagnostic performance of panoramic radiographs obtained with low-dose protocols did not differ from that of panoramic radiographs obtained with the highest dose (p > 0.05). Moreover, substantial agreement was observed between all protocols. Protocol 1 resulted in the highest absorbed dose and protocols 4, 5 and 6 in the lowest absorbed doses, with the difference being significant (p ≤ 0.05). CONCLUSION: Although digital panoramic radiography is considered a relatively low-dose examination, the radiation dose can be further reduced without negatively affecting its overall diagnostic performance. CLINICAL RELEVANCE: Considering the risks associated with X-rays, digital panoramic radiographs can be obtained at even lower exposure levels.


Assuntos
Radiografia Dentária Digital , Dosimetria Termoluminescente , Imagens de Fantasmas , Doses de Radiação , Radiografia Panorâmica , Reprodutibilidade dos Testes
15.
J Aging Phys Act ; 29(2): 200-206, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32820137

RESUMO

AIMS: To compare the postactivation potentiation effects of isometric contraction until failure in double- and single-leg tasks on older women's balance. METHODS: The one-legged balance test was performed before and immediately after a rise-to-toes task until the task failure. Older women were divided into two groups: a group performed the task with double leg (n = 43) and the other group with single-leg support (n = 55). RESULTS: The single-leg group showed slower velocity of sway post rise-to-toes task (pre = 4.02 ± 1; post = 3.78 ± 1.15 m/s; p = .04) without differences for the center of pressure path length (pre = 79 ± 21; post = 75 ± 23 cm; p = .08). In the double-leg group, faster velocity of sway (pre = 4 ± 1.22; post = 4.25 ± 1.13; p = .03) and increased center of pressure path length (pre = 80 ± 24; post = 85 ± 23 cm; p = .03) were observed after the task. CONCLUSIONS: The single-leg group showed improved balance outcomes due to postactivation potentiation, while the double-leg group showed worsened balance consistent with muscle fatigue.


Assuntos
Perna (Membro) , Equilíbrio Postural , Idoso , Feminino , Humanos , Fadiga Muscular
16.
Semin Musculoskelet Radiol ; 24(5): 479-487, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33036036

RESUMO

This critical review discusses the clinical challenges for patient-specific and indication-oriented dentomaxillofacial cone beam computed tomography (CBCT). Large variations among units and protocols may lead to variable degrees of diagnostic and three-dimensional model accuracy, impacting both specific diagnostic tasks and treatment planning. Particular indications, whether diagnostic or therapeutic, may give rise to very specific challenges with regard to CBCT unit and parameter setup, considering the required image quality, segmentation accuracy, and artifact level. Considering that dental materials are in the field of view needed for diagnosis or treatment planning, artifact expression is a dominant factor in proper CBCT selection. The heterogeneity of dental CBCT units and performances may highly impact the scientific results. Thus research findings cannot be simply generalized as published evidence, and a demonstrated clinical applicability for a specific indication should not be simply extrapolated from one CBCT unit to another.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Radiografia Dentária/métodos , Doenças Estomatognáticas/diagnóstico por imagem , Artefatos , Humanos
17.
J Manipulative Physiol Ther ; 43(8): 806-815, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32893024

RESUMO

OBJECTIVE: The purpose of this study was to assess the effects of 4-week protocol of diacutaneous fibrolysis (DF) compared with simulated DF (sham-DF) on myalgia and mouth opening. METHODS: In a sham randomized controlled trial, 34 women with temporomandibular disorders and myofascial pain were randomly divided as intervention group (IG) and sham-DF group (SG). The IG received 4 weeks of real DF, and the SG received sham. Pain was assessed through the visual analog scale and pressure pain thresholds (PPTs) on the temporomandibular joint (TMJ), and over the temporal and masseter muscles. The Mandibular Function Impairment Questionnaire was used to classify the participants regarding to the severity of the functional limitation related to TMD. RESULTS: Pain scores decreased for both groups, but the IG showed lower values at week 4, with between-group differences. Bilateral temporal PPT showed higher values at week 4, with between-group differences. The SG had lower PPTs but the IG had higher PPTs, both compared to baseline results. The time-by-group interaction and the frequency of participants above 40 mm of mouth opening showed a significant difference for the IG over time with higher results at the 4-week assessment compared to its own baseline. Both groups showed lower MFIQ scores from baseline to 4-week assessment. There was a lower frequency of a moderate level of severity for the IG. No differences were observed for TMJ or for the masseter muscles PPT. CONCLUSION: Improvements were observed for visual analog scale scores and PPTs on temporal muscles. There was a group-by-time interaction in the IG, suggesting a possible potential use of DF for mouth opening.


Assuntos
Dor Facial/terapia , Músculos da Mastigação/fisiopatologia , Mialgia/terapia , Síndromes da Dor Miofascial/terapia , Modalidades de Fisioterapia , Transtornos da Articulação Temporomandibular/terapia , Articulação Temporomandibular/fisiopatologia , Adulto , Dor Facial/patologia , Dor Facial/fisiopatologia , Feminino , Humanos , Mandíbula/patologia , Mandíbula/fisiopatologia , Massagem , Músculo Masseter/patologia , Músculo Masseter/fisiopatologia , Músculos da Mastigação/patologia , Boca , Mialgia/fisiopatologia , Síndromes da Dor Miofascial/fisiopatologia , Medição da Dor , Limiar da Dor , Índice de Gravidade de Doença , Músculo Temporal/patologia , Músculo Temporal/fisiopatologia , Articulação Temporomandibular/patologia , Transtornos da Articulação Temporomandibular/patologia , Transtornos da Articulação Temporomandibular/fisiopatologia , Resultado do Tratamento , Adulto Jovem
18.
Dentomaxillofac Radiol ; 53(3): 196-202, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38290763

RESUMO

OBJECTIVES: To evaluate the feasibility of frozen soft tissues in simulating fresh soft tissues of pig mandibles using cone beam CT (CBCT). METHODS: Two fresh pig mandibles with soft tissues containing 2 tubes filled with a radiopaque homogeneous solution were scanned using 4 CBCT units and 2 field-of-view (FOV) sizes each. The pig mandibles were deep-frozen and scanned again. Three cross-sections were exported from each CBCT volume and grouped into pairs, with one cross-section representing a fresh and one a frozen mandible. Three radiologists compared the pairs and attributed a score to assess the relative image quality using a 5-point scale. Mean grey values and standard deviation were obtained from homogeneous areas in the tubes, compared using the Wilcoxon matched-pair signed-rank test and subjected to Pearson correlation analysis between fresh and frozen physical states (α = .05). RESULTS: Subjective evaluation revealed similarity of the CBCT image quality between fresh and frozen states. The distribution of mean grey values was similar between fresh and frozen states. Mean grey values of the frozen state in the small FOV were significantly greater than those of the fresh state (P = .037), and noise values of the frozen state in the large FOV were significantly greater than those of the fresh state (P = 0.007). Both mean grey values and noise exhibited significant and positive correlations between fresh and frozen states (P < 0.01). CONCLUSIONS: The freezing of pig mandibles with soft tissues may serve as a method to prolong their usability and working time when CBCT imaging is planned.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Mandíbula , Suínos , Animais , Estudos de Viabilidade , Congelamento , Tomografia Computadorizada de Feixe Cônico/métodos , Mandíbula/diagnóstico por imagem
19.
Imaging Sci Dent ; 54(1): 49-56, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38571773

RESUMO

Purpose: This study evaluated the impact of artifacts generated by metal crowns on the detection of proximal caries lesions in teeth at various distances using cone-beam computed tomography (CBCT). Additionally, the diagnostic impacts of tube current and metal artifact reduction (MAR) were investigated. Materials and Methods: Thirty teeth were arranged within 10 phantoms, each containing 1 first premolar, 1 second premolar, and 1 second molar. A sound first molar (for the control group) or a tooth with a metal crown was placed. Of the 60 proximal surfaces evaluated, 15 were sound and 45 exhibited enamel caries. CBCT scans were acquired using an OP300 Maxio unit (Instrumentarium, Tuusula, Finland), while varying the tube current (4, 8, or 12.5 mA) and enabling or disabling MAR. Five observers assessed mesial and distal surfaces using a 5-point scale. Multi-way analysis of variance was employed for data comparison, with P<0.05 indicating statistical significance. Results: The area under the curve (AUC) varied from 0.40 to 0.60 (sensitivity: 0.28-0.45, specificity: 0.44-0.80). The diagnostic accuracy was not significantly affected by the presence of a metal crown, milliamperage, or MAR (P>0.05). However, the overall AUC and specificity were significantly lower for surfaces near a crown (P<0.05). Conclusion: CBCT-based caries detection was not influenced by the presence of a metal crown, variations in milliamperage, or MAR activation. However, the diagnostic accuracy was low and was further diminished for surfaces near a crown. Consequently, CBCT is not recommended for the detection of incipient caries lesions.

20.
J Imaging Inform Med ; 37(1): 145-150, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38343236

RESUMO

To assess the effect of digital enhancement on the image quality of radiographs obtained with photostimulable phosphor (PSP) plates partially damaged by ambient light. Radiographs of an aluminum step wedge were obtained using the VistaScan and Express systems. Half of the PSP plates was exposed to ambient light for 0, 10, 30, 60, or 90 s before being scanned. The resulting radiographs were exported with and without digital enhancement. Metrics for brightness, contrast, and contrast-to-noise ratio (CNR) were derived, and the ratio of each metric between the exposed-to-light and non-exposed-to-light halves of the radiographs was calculated. The resulting ratios of the radiographs with digital enhancement were subtracted from those without digital enhancement and compared among each other. For the VistaScan system, digital enhancement partially restored brightness, contrast, and CNR. For the Express system, digital enhancement only restored CNR and not the impact of ambient light on brightness and contrast. Specifically, digital enhancement restored 23.48% of brightness for the VistaScan, while percentages below 1% were observed for the Express. Digital enhancement restored 53.25% of image contrast for the VistaScan and 5.79% for the Express; 40.71% of CNR was restored for the VistaScan, and 35% for the Express. Digital enhancement can partially restore the damage caused by ambient light on the brightness and contrast of PSP-based radiographs obtained with the VistaScan, as well as on CNR for the VistaScan and Express systems. The exposure of PSP plates to light can lead to unnecessary retakes and increased patient exposure to X-rays.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA