Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
J Intensive Care Med ; 39(3): 203-216, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38056074

RESUMO

OBJECTIVE: Right ventricular dysfunction (RVD) is common in the critically ill. To date studies exploring RVD sequelae have had heterogenous definitions and diagnostic methods, with limited follow-up. Additionally much literature has been pathology specific, limiting applicability to the general critically unwell patient. METHOD AND STUDY DESIGN: We conducted a systematic review and meta-analysis to evaluate the impact of RVD diagnosed with transthoracic echocardiography (TTE) on long-term mortality in unselected critically unwell patients compared to those without RVD. A systematic search of EMBASE, Medline and Cochrane was performed from inception to March 2022. All RVD definitions using TTE were included. Patients were those admitted to a critical or intensive care unit, irrespective of disease processes. Long-term mortality was defined as all-cause mortality occurring at least 30 days after hospital admission. A priori subgroup analyses included disease specific and delayed mortality (death after hospital discharge/after the 30th day from hospital admission) in patients with RVD. A random effects model analysis was performed with the Dersimionian and Laird inverse variance method to generate effect estimates. RESULTS: Of 5985 studies, 123 underwent full text review with 16 included (n = 3196). 1258 patients had RVD. 19 unique RVD criteria were identified. The odds ratio (OR) for long term mortality with RVD was 2.92 (95% CI 1.92-4.54, I2 76.4%) compared to no RVD. The direction and extent was similar for cardiac and COVID19 subgroups. Isolated RVD showed an increased risk of delayed mortality when compared to isolated left/biventricular dysfunction (OR 2.01, 95% CI 1.05-3.86, I2 46.8%). CONCLUSION: RVD, irrespective of cause, is associated with increased long term mortality in the critically ill. Future studies should be aimed at understanding the pathophysiological mechanisms by which this occurs. Commonly used echocardiographic definitions of RVD show significant heterogeneity across studies, which contributes to uncertainty within this dataset.


Assuntos
Disfunção Ventricular Direita , Humanos , Disfunção Ventricular Direita/diagnóstico por imagem , Estado Terminal , Ecocardiografia , Unidades de Terapia Intensiva
2.
Hong Kong Physiother J ; 44(1): 39-56, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38577395

RESUMO

Impaired respiratory function secondary to acute or chronic respiratory disease poses a significant clinical and healthcare burden. Intrapulmonary percussive ventilation (IPV) is used in various clinical settings to treat excessive airway secretions, pulmonary atelectasis, and impaired gas exchange. Despite IPV's wide use, there is a lack of clinical guidance on IPV application which may lead to inconsistency in clinical practice. This scoping review aimed to summarise the clinical application methods and dosage of IPV used by clinicians and researchers to provide guidance. A two-staged systematic search was conducted to retrieve studies that used IPV in inpatient and outpatient settings. MEDLINE, EMBASE, CINAHL, Scopus, and Google scholar were searched from January 1979 till 2022. Studies with patients aged ≥16 years and published in any language were included. Two reviewers independently screened the title and abstract, reviewed full text articles, and extracted data. Search yielded 514 studies. After removing duplicates and irrelevant studies, 25 studies with 905 participants met the inclusion criteria. This is the first scoping review to summarise IPV application methods and dosages from the available studies in intensive care unit (ICU), acute inpatient (non-ICU), and outpatient settings. Some variations in clinical applications and prescribed dosages of IPV were noted. Despite variations, common trends in clinical application and prescription of IPV dosages were observed and summarised to assist clinicians with IPV intervention. Although an evidence-based clinical guideline could not be provided, this review provides detailed information on IPV application and dosages in order to provide clinical guidance and lays a foundation towards developing a clinical practice guideline in the future.

3.
Crit Care ; 26(1): 303, 2022 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-36192793

RESUMO

INTRODUCTION: Right ventricular (RV) and pulmonary vascular dysfunction appear to be common in sepsis. RV performance is frequently assessed in isolation, yet its close relationship to afterload means combined analysis with right ventricular outflow tract (RVOT) Doppler and RV-pulmonary arterial (RV-PA) coupling may be more informative than standard assessment techniques. Data on feasibility and utility of these parameters in sepsis are lacking and were explored in this study. METHODS: This is a retrospective study over a 3-year period of one-hundred and thirty-one patients admitted to ICU with sepsis who underwent transthoracic echocardiography (TTE) with RVOT pulsed wave Doppler. RVOT Doppler flow and RV-PA coupling was evaluated alongside standard measurements of RV systolic function and pulmonary pressures. RVOT Doppler analysis included assessment of pulmonary artery acceleration time (PAAT), velocity time integral and presence of notching. RV-PA coupling was assessed using tricuspid annular planar systolic excursion/pulmonary artery systolic pressure (TAPSE/PASP) ratio. RESULTS: PAAT was measurable in 106 (81%) patients, and TAPSE/PASP was measurable in 77 (73%). Seventy-three (69%) patients had a PAAT of ≤ 100 ms suggesting raised pulmonary vascular resistance (PVR) is common. RVOT flow notching occurred in 15 (14%) of patients. TRV was unable to be assessed in 24 (23%) patients where measurement of PAAT was possible. RV dysfunction (RVD) was present in 28 (26%), 26 (25%) and 36 (34%) patients if subjective assessment, TAPSE < 17 mm and RV dilatation definitions were used, respectively. There was a trend towards shorter PAAT with increasing severity of RVD. RV-PA uncoupling defined as a TAPSE/PASP < 0.31 mm/mmHg was present in 15 (19%) patients. As RV dilatation increased the RV-PA coupling ratio decreased independent of LV systolic function, whereas TAPSE appeared to be more susceptible to changes in LV systolic function. CONCLUSION: Raised PVR and RV-PA uncoupling is seen in a significant proportion of patients with sepsis. Non-invasive assessment with TTE is feasible. The role of these parameters in assisting improved definitions of RVD, as well as their therapeutic and prognostic utility against standard parameters, deserves further investigation.


Assuntos
Hipertensão Pulmonar , Sepse , Disfunção Ventricular Direita , Ecocardiografia/métodos , Humanos , Artéria Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Sepse/complicações , Disfunção Ventricular Direita/diagnóstico por imagem
4.
Intern Med J ; 52(11): 1986-1990, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36000277

RESUMO

We present the first Australian cohort of patients with COVID-19 respiratory failure managed with escalating respiratory support including continuous positive airway pressure (CPAP) on a standard medical ward at a tertiary Sydney hospital during the 2021 COVID-19 Delta variant outbreak. We demonstrate an equivalent mortality to CPAP delivered in intensive care unit and outline our ward structure and management during the pandemic.


Assuntos
COVID-19 , Insuficiência Respiratória , Humanos , Pressão Positiva Contínua nas Vias Aéreas , Estudos Retrospectivos , Austrália/epidemiologia , SARS-CoV-2 , Centros de Atenção Terciária , Insuficiência Respiratória/terapia
5.
Heart Lung Circ ; 29(5): 785-792, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31353215

RESUMO

BACKGROUND: Right ventricular (RV) dysfunction can occur after cardiac surgery and persist for years. We assessed perioperative RV systolic function in patients undergoing mitral valve (MV) repair and further compared minimally invasive robotic-assisted mitral valve repair (MIMVr) vs standard 'open' MV repair (MVr). Speckle tracking (RV free wall strain [RVS]) was used as a sensitive echocardiography method to assess RV function. METHODS: Retrospective analysis, over 3 years, of consecutive patients (n = 158) referred to Mayo Clinic (Rochester, MN, USA). Preoperative, pre-discharge and 1 year transthoracic echocardiograms were reviewed. A prospective pilot study was performed for sample size estimation. Primary outcome was RV free wall strain (RVS). RESULTS: Right ventricular free wall strain declined after MV repair surgery (-22.6 ± 7% vs -15 ± 6%, p < 0.001). There were smaller reductions in RVS in MIMVr vs MVr group (-6.0 ± 9% vs -10.3 ± 8%, p < 0.01), which persisted after adjusting for baseline values (RVS treatment effect 1.5%, p = 0.007). There was greater recovery in MIMVr vs MVr group at 1 year follow-up vs pre-surgery values (-3.4 ± 9% vs -8.1 ± 8% respectively, p < 0.001, RVS treatment effect 1.7%, p = 0.001). Bypass time was higher in the MIMVr group (80min ± 22 vs 40min ± 20, p < 0.0001). The echo findings remained significant correcting for age, pulmonary pressures and change in ejection fraction. CONCLUSIONS: Right ventricular systolic dysfunction is common after MV repair surgery. Deterioration in RV contraction is less pronounced following MIMVr vs MVr and is associated with enhanced RV functional recovery at 1 year, albeit not to preoperative levels. This may potentially be associated with clinical functional improvement but further studies are warranted to investigate this.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Ventrículos do Coração/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Função Ventricular Direita/fisiologia , Idoso , Ecocardiografia/métodos , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Projetos Piloto , Período Pós-Operatório , Estudos Retrospectivos , Sístole
6.
Crit Care Med ; 47(1): 41-48, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30379666

RESUMO

OBJECTIVES: Doppler echocardiography is a well-recognized technique for the noninvasive evaluation of pulmonary artery pressure; however, little information is available concerning patients receiving mechanical ventilation. Furthermore, recent studies have debatable results regarding the relevance of this technique to assess pulmonary artery pressure. The aim of our study was to reassess the accuracy of Doppler echocardiography to evaluate pulmonary artery pressure and to predict pulmonary hypertension. DESIGN: Prospective observational study. SETTING: Amiens ICU, France. PATIENTS: ICU patients receiving mechanical ventilation. INTERVENTIONS: In 40 patients, we simultaneously recorded Doppler echocardiography variables (including tricuspid regurgitation and pulmonary regurgitation) and invasive central venous pressure, systolic pulmonary artery pressure, diastolic pulmonary artery pressure, and mean pulmonary artery pressure. MEASUREMENTS AND MAIN RESULTS: Systolic pulmonary artery pressure assessed from the tricuspid regurgitation derived maximal pressure gradient added to the central venous pressure demonstrated the best correlation with the invasive systolic pulmonary artery pressure (r = 0.87) with a small bias (-3 mm Hg) and a precision of 9 mm Hg. A Doppler echocardiography systolic pulmonary artery pressure greater than 39 mm Hg predicted pulmonary hypertension (mean pulmonary artery pressure ≥ 25 mm Hg) with 100% sensitivity and specificity. Tricuspid regurgitation maximal velocity greater than 2.82 m/s as well as tricuspid regurgitation pressure gradient greater than 32 mm Hg predicted the presence of pulmonary hypertension. Pulmonary regurgitation was recorded in 10 patients (25%). No correlation was found between pulmonary regurgitation velocities and either mean pulmonary artery pressure or diastolic pulmonary artery pressure. Pulmonary acceleration time less than 57 ms and isovolumic relaxation time less than 40 ms respectively predicted pulmonary hypertension 100% of the time and had a 100% negative predictive value. CONCLUSIONS: Tricuspid regurgitation maximal velocity pressure gradient added to invasive central venous pressure accurately estimates systolic pulmonary artery pressure and mean pulmonary artery pressure in ICU patients receiving mechanical ventilation and may predict pulmonary hypertension.


Assuntos
Ecocardiografia Doppler , Hipertensão Pulmonar/diagnóstico , Artéria Pulmonar/diagnóstico por imagem , Respiração Artificial , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Pressão Venosa Central/fisiologia , Feminino , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sístole/fisiologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia
7.
Crit Care ; 23(1): 257, 2019 07 17.
Artigo em Inglês | MEDLINE | ID: mdl-31315648

RESUMO

BACKGROUND: Diagnosis of significant coronary artery disease (CAD) and acute coronary artery occlusion in ICU can be difficult, and an inappropriate intervention is potentially harmful. Myocardial contrast perfusion echo (MCPE) examines ultrasound contrast intensity replenishment curves in individual myocardial segments measuring peak contrast intensity and slope of return as an index of myocardial blood flow (units = intensity of ultrasound per second [dB/s]). MCPE could possibly serve as a triage tool to invasive angiography by estimating blood flow in the myocardium. We sought to assess feasibility in the critically ill and if MCPE could add incremental value to the clinical acumen in predicting significant CAD. METHODS: This is a single-centre, prospective, observational study. Inclusion criteria were as follows: adult ICU patients with troponin I > 50 ng/L and cardiology referral being made for consideration of inpatient angiography. Exclusion criteria were as follows: poor echo windows (2 patients), known ischaemic heart disease, and contrast contraindications. Seven cardiologists and 6 intensivists blinded to outcome assessed medical history, ECG, troponin, and 2D echo images to estimate likelihood of significant CAD needing intervention (clinical acumen). Clinical acumen, quantitative MCPE, and subjective (visual) MCPE were assessed to predict significant CAD. RESULTS: Forty patients underwent MCPE analysis, 6 (15%) had significant CAD, and median 11 of 16 segments (IQR 8-13) could be imaged (68.8% [IQR 50-81]). No adverse events occurred. A significant difference was found in overall MCPE blood flow estimation between those diagnosed with significant CAD and those without (3.3 vs 2.4 dB/s, p = 0.050). A MCPE value of 2.8 dB/s had 67% sensitivity and 88% specificity in detecting significant CAD. Clinical acumen showed no association in prediction of CAD (OR 0.6, p = 0.09); however, if quantitative or visual MCPE analysis was included, a significant association occurred (OR 17.1, p = 0.01; OR 23.0, p = 0.01 respectively). CONCLUSIONS: MCPE is feasible in the critically ill and shows better association with predicting significant CAD vs clinical acumen alone. MCPE adds incremental value to initial assessment of the presence of significant CAD which may help guide those who require urgent angiography.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Ecocardiografia/métodos , Perfusão/normas , Adulto , Idoso , Meios de Contraste/uso terapêutico , Doença da Artéria Coronariana/fisiopatologia , Ecocardiografia/normas , Estudos de Viabilidade , Feminino , Humanos , Unidades de Terapia Intensiva/organização & administração , Unidades de Terapia Intensiva/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , New South Wales , Perfusão/estatística & dados numéricos , Estudos Prospectivos , Troponina I/análise , Troponina I/sangue
8.
Crit Care ; 23(1): 70, 2019 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-30845976

RESUMO

BACKGROUND: Right ventricle (RV) size and function assessment by echocardiography (echo) is a standard tool in the ICU. Frequently subjective assessment is performed, and guidelines suggest its utility in adequately trained clinicians. We aimed to compare subjective (visual) assessment of RV size and function by ICU physicians, with advanced qualifications in echocardiography, vs objective measurements. METHODS: ICU specialists with a qualification in advanced echocardiography reviewed 2D echo clips from critically ill patients on mechanical ventilation with PaO2:FiO2 < 300. Subjective assessments of RV size and function were made independently using a three-class categorical scale. Agreement (B-score) and bias (p value) were analysed using objective echo measurements. RV size assessment included RV end-diastolic area (EDA) and diameters. RV function assessment included fractional area change, S', TAPSE and RV free wall strain. Binary and ordinal analysis was performed. RESULTS: Fifty-two clinicians reviewed 2D images from 80 patients. Fair agreement was seen with objective measures vs binary assessment of RV size (RV EDA 0.26 [p < 0.001], RV dimensions 0.29 [p = 0.06]) and function (RV free wall strain 0.27 [p < 0.001], TAPSE 0.27 [p < 0.001], S' 0.29 [p < 0.001], FAC 0.31 [p = 0.16]). However, ordinal data analysis showed poor agreement with RV dimensions (0.11 [p = 0.06]) and RV free wall strain (0.14 [p = 0.16]). If one-step disagreement was allowed, agreement was good (RV dimensions 0.6 [p = 0.06], RV free wall strain 0.6 [p = 0.16]). Significant overestimation of severity of abnormalities was seen with subjective assessment vs RV EDA, TAPSE, S' and fractional area change. CONCLUSION: Subjective (visual) assessment of RV size and function, by ICU specialists trained in advanced echo, can be fairly reliable for the initial exclusion of significant RV pathology. It seems prudent to avoid subjective RV assessment in isolation.


Assuntos
Competência Clínica/normas , Ecocardiografia/normas , Ventrículos do Coração/fisiopatologia , Função Ventricular Direita/fisiologia , Adulto , Idoso , Distribuição de Qui-Quadrado , Cuidados Críticos/métodos , Autoavaliação Diagnóstica , Ecocardiografia/métodos , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Unidades de Terapia Intensiva/organização & administração , Unidades de Terapia Intensiva/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Médicos/normas , Médicos/estatística & dados numéricos , Reprodutibilidade dos Testes
9.
Acta Anaesthesiol Scand ; 63(5): 594-600, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30648262

RESUMO

BACKGROUND: The distending intravascular pressure at no flow conditions reflects the stressed volume. While this haemodynamic variable is recognised as clinically important, there is a paucity of reports of its range and responsiveness to volume expansion in patients without cardiovascular disease and no reports of correlations to echocardiographic assessments of left ventricular filling. METHODS: Twenty-seven awake (13 male), spontaneously breathing patients without any history of cardiopulmonary, vascular or renal disease were studied prior to induction of anaesthesia. The no-flow equilibrium pressure in the arm following rapid circulatory occlusion (Parm ) was measured via a radial arterial catheter. Transthoracic echocardiography was used to measure left ventricular end diastolic area and volume as well as the diameter of the inferior vena cava. The Parm and echocardiographic variables were measured before and after administration of 500 mL 0.9% NaCl over 10 minutes. Changes were analysed by paired t test, Pearson's correlation and multiple linear regression. RESULTS: Parm increased overall from 22 ± 5 mm Hg to 25 ± 6 mm Hg (mean difference 3.0 ± 4.5 mm Hg, P = 0.002) following the fluid bolus with corresponding increases in arterial pressure and echocardiographic variables. Variability in the direction of the Parm response reflected concomitant changes in vascular compliance. Only weak correlations were observed between changes in Parm and inferior vena cava diameter indexed to body surface area (R2  = 0.29, P = 0.01). CONCLUSION: Preoperative measurements of Parm increased following acute expansion of the intravascular volume. Echocardiography demonstrated poor correlation with Parm .


Assuntos
Ecocardiografia , Hidratação , Artéria Radial/fisiologia , Adulto , Pressão Arterial/fisiologia , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Estudos Prospectivos , Veia Cava Inferior/fisiologia
10.
Crit Care Med ; 46(10): 1608-1616, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30028364

RESUMO

OBJECTIVES: Open lung ventilation with a recruitment maneuver could be beneficial for acute respiratory distress syndrome patients. However, the increased airway pressures resulting from the recruitment maneuver may induce cardiac dysfunction, limiting the benefit of this maneuver. We analyzed the effect of a recruitment maneuver and decremental positive end-expiratory pressure titration on cardiac function. SETTINGS: Medical ICU Amiens, France. PATIENTS: Twenty patients with moderate to severe acute respiratory distress syndrome INTERVENTIONS:: Patients underwent a stepwise recruitment maneuver with respiratory evaluation and echocardiography assessment of cardiac function including longitudinal strain at baseline, peak positive end-expiratory pressure of recruitment maneuver (positive end-expiratory pressure 40 cm H2O), and at "optimal" positive end-expiratory pressure. The patients were divided into two groups based on change on the PaO2/FIO2 ratio (nonresponders < 50%; responders ≥ 50%). MEASUREMENTS AND MAIN RESULTS: At peak positive end-expiratory pressure during the recruitment maneuver, the arterial pressure, cardiac output, left ventricular size decreased and right ventricular size increased. The left ventricular ejection fraction decreased from 60% ± 13% to 48% ± 18% (p = 0.05). Both left and right ventricular global longitudinal strain were impaired (-15.8% ± 4.5% to -11% ± 4.7% and -19% ± 5% to -14% ± 6% [p = 0.05] respectively). Fifty percent of patients were nonresponders and demonstrated a lower hemodynamic tolerance to the recruitment maneuver than responders. Optimal positive end-expiratory pressure was 14 ± 5 cm H2O (vs 11 ± 4 cm H2O at baseline), and PaO2/FIO2 ratio increased from 111 ± 25 to 197 ± 89 mm Hg (p < 0.0001). All hemodynamic variables returned to their baseline value after the recruitment maneuver despite a higher positive end-expiratory pressure. CONCLUSIONS: An open lung strategy with a stepwise recruitment maneuver permitted a higher positive end-expiratory pressure and improved oxygenation without any cardiac impairment. The recruitment maneuver was associated with mild and transient, cardiac dysfunction, with nonresponders demonstrating poorer tolerance.


Assuntos
Respiração com Pressão Positiva/métodos , Síndrome do Desconforto Respiratório/fisiopatologia , Mecânica Respiratória/fisiologia , Volume de Ventilação Pulmonar/fisiologia , Idoso , Ecocardiografia Transesofagiana/métodos , Feminino , França , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/terapia
11.
Crit Care ; 22(1): 198, 2018 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-30121088

RESUMO

BACKGROUND: Transthoracic 3D cardiac analysis is enticing in its potential simplicity and wealth of data available. It has been suggested to be accurate vs magnetic resonance imaging in relatively stable patients, but feasibility and agreement with conventional echocardiographic assessment of stroke volume (SV) have not been thoroughly assessed in critically ill patients, who are traditionally harder to image. The objectives of this study were to compare 3D transthoracic volumetric analysis vs Doppler assessment of SV (which is suggested to be accurate in the critically ill) and Simpson's biplane assessment in a cohort typical of the intensive care unit (ICU), where accurate assessment is important: mechanically ventilated patients with a significant ventilation/perfusion (V/Q) mismatch. We hypothesised that it would be feasible but might lack agreement. METHODS: Patients were imaged within 24 hours of admission. Inclusion criteria were adult patients, V/Q mismatch present (defined as a ratio of arterial oxygen partial pressure to fractional inspired oxygen < 300), and mechanically ventilated with Doppler SV assessment possible. Biventricular echocardiographic volumetric analysis was performed using Siemens SC2000 along with standard Simpson's biplane and Doppler SV assessment. 3D images were unacceptable if two segments or more were unable to be seen in two volumetric planes. 3D left ventricular (3DLV) and 3D right ventricular (3DRV) analyses were performed with the Tomtec Imaging and Siemens Acuson platforms, respectively. RESULTS: Ninety-two patients were included (83 in sinus, 9 in atrial fibrillation). 3DLV and 3DRV analyses were feasible in 72% and 55% of patients, respectively; however, they underestimated SV compared with Doppler by 2.6 ml (± 10.4) and 4.1 ml (± 15.4), respectively. Limits of agreement for 2D, 3DLV and 3DRV volumetric analysis techniques were large. CONCLUSIONS: 3DLV and 3DRV volumetric analyses appear feasible (obtainable) in the majority of mechanically ventilated ICU patients. Compared with the Doppler method, 3DLV and 3DRV volumetric analyses underestimate SV. The large limits of agreement between the methods also cast doubt on their comparability. Given the scenarios in which SV analysis is required (e.g., assessment of cardiac performance), our study cautions against the use of 3D SV clinically.


Assuntos
Ecocardiografia/métodos , Monitorização Fisiológica/normas , Pesos e Medidas/instrumentação , Idoso , Austrália , Estudos de Coortes , Estado Terminal , Ecocardiografia Tridimensional/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Reprodutibilidade dos Testes , Volume Sistólico/fisiologia , Pesos e Medidas/normas
12.
Crit Care ; 21(1): 279, 2017 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-29149863

RESUMO

Critical care echocardiography is developing rapidly with an increasing number of specialists now performing comprehensive studies using Doppler and other advanced techniques. However, this imaging can be challenging, interpretation is far from simple in the complex critically ill patient and mistakes can be easy to make. We aim to address clinically relevant areas where potential errors may occur and suggest methods to hopefully improve accuracy of imaging and interpretation.


Assuntos
Ecocardiografia/métodos , Testes de Função Cardíaca/métodos , Cuidados Críticos/métodos , Cuidados Críticos/normas , Ecocardiografia/normas , Testes de Função Cardíaca/normas , Humanos , Volume Sistólico/fisiologia
13.
Crit Care ; 21(1): 175, 2017 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-28705247

RESUMO

BACKGROUND: Left ventricular diastolic dysfunction is associated with mortality outcomes in severe sepsis and septic shock. There are ongoing issues with diagnosing diastolic dysfunction in this cohort, partly owing to the poor applicability of traditional parameters in the hyperdynamic circulation. In this feasibility study, we sought to assess the utility of a novel parameter (septal e'/s') to identify diastolic dysfunction in patients with severe sepsis and septic shock who had normal systolic function against the 2016 American Society Echocardiography and European Association of Cardiovascular Imaging (ASE/EACI) guidelines on diastolic dysfunction. METHODS: In this prospective observational pilot study, patients identified as having severe sepsis and septic shock underwent transthoracic echocardiography on day 1 and day 3 of their intensive care unit admission. In patients with normal systolic function, septal e'/s' was calculated using the peak modal velocity of the s' compared with the e' from the septal annulus tissue Doppler imaging and compared with their diastolic grade according to the 2016 ASE/EACI guidelines on diastolic dysfunction. RESULTS: On day 1 of admission, 44 of 62 patients with severe sepsis and septic shock had normal systolic function. There was a strong association of those with diastolic dysfunction having a reduced septal e'/s' compared with patients with normal diastolic function (AUC 0.91). A similar relationship was seen with patients who had indeterminate diastolic dysfunction. On day 3, 37 patients had normal systolic function. Again, there was a strong association of those with diastolic dysfunction and a reduced septal e'/s' (AUC 0.95). CONCLUSIONS: A reduction in septal e'/s' may indicate diastolic dysfunction in patients with severe sepsis and septic shock who have normal systolic function. As opposed to limited traditional measures of diastolic dysfunction, it is applicable in those with hyperdynamic systolic function.


Assuntos
Ecocardiografia Doppler/métodos , Relaxamento Muscular/fisiologia , Miocárdio/patologia , Sepse/patologia , Idoso , Austrália , Distribuição de Qui-Quadrado , Feminino , Humanos , Unidades de Terapia Intensiva/organização & administração , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Curva ROC , Sepse/complicações , Sepse/fisiopatologia , Choque Séptico/complicações , Choque Séptico/patologia , Choque Séptico/fisiopatologia , Volume Sistólico/fisiologia
15.
Crit Care ; 20: 58, 2016 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26976127

RESUMO

This article is one of ten reviews selected from the Annual Update in Intensive Care and Emergency medicine 2016. Other selected articles can be found online at http://www.biomedcentral.com/collections/annualupdate2016. Further information about the Annual Update in Intensive Care and Emergency Medicine is available from http://www.springer.com/series/8901.


Assuntos
Estado Terminal/terapia , Ecocardiografia/métodos , Imagem de Perfusão do Miocárdio/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Unidades de Terapia Intensiva
16.
BMC Anesthesiol ; 16(1): 43, 2016 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-27456490

RESUMO

BACKGROUND: Conventionally, ultrasonographic assessment of diaphragm contractility has involved measuring respiratory changes in diaphragm thickness (thickening fraction) using B-mode or caudal displacement with M-mode. Two-dimensional speckle-tracking has been increasingly used to assess muscle deformation ('strain') in echocardiography. We sought to determine in a pilot study if this technology could be utilized to analyze diaphragmatic contraction. METHODS: Fifty healthy adult volunteers with normal exercise capacity underwent ultrasound imaging. A linear array transducer was used for the assessment of diaphragm thickness, thickening fraction (TF), and strain in the right anterior axillary line at approximately the ninth intercostal space. A phased array transducer was applied subcostally for the assessment of diaphragm displacement on the right mid-clavicular line. Diaphragmatic images were recorded from the end of expiration through the end of inspiration at 60 % maximal inspiratory capacity. Diaphragm strain was analyzed off-line by speckle tracking imaging. Blinded inter- and intra-rater variability was tested in 10 cases. RESULTS: Mean right diaphragm thickness at end-expiration (±SD: standard deviation) was 0.24 cm (±0.1), with TF of 45.1 % (±12) at 60 % peak inspiratory effort. Mean right diaphragm caudal displacement was 4.9 cm (±1). Mean right diaphragm strain was -40.3 % (±9). A moderate correlation was seen between longitudinal strain and TF (R(2) 0.44, p < 0.0001). A weak correlation was seen between strain and caudal displacement (R(2) 0.14, p < 0.01), and an even weaker correlation was seen between caudal displacement and TF (R(2) 0.1, p = 0.04). Age, gender, and body mass index were not significantly associated with right diaphragm strain or TF. Although inter- and intra-rater variability was overall good for TF, caudal displacement, and strain (inter-rater R(2); 0.8, 0.9, and 0.7, respectively [p < 0.01], intra-rater R(2); 0.9, 0.7, and 0.9, respectively [p < 0.01]), strain values did have a slightly lower inter-rater repeatability. CONCLUSIONS: Diaphragmatic strain estimated by speckle tracking imaging was associated with conventional ultrasound measures of diaphragmatic function (TF and caudal displacement). Further clinical studies are warranted to investigate its clinical utility.


Assuntos
Diafragma/diagnóstico por imagem , Ecocardiografia/métodos , Ultrassonografia/métodos , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Variações Dependentes do Observador , Projetos Piloto , Método Simples-Cego , Adulto Jovem
17.
J Ultrasound Med ; 35(12): 2615-2621, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27872418

RESUMO

OBJECTIVES: Sonographic assessment of diaphragm displacement has conventionally been conducted with M-mode sonography via an anterior subcostal approach. This method is subject to measurement errors when diaphragm displacement is not in line with the M-mode plane. We aimed to compare measurements obtained by offline angle-independent (anatomic) M-mode sonography with conventional M-mode sonography. METHODS: Fifty healthy adults were imaged with conventional and angle-independent M-mode sonography of the bilateral hemidiaphragms at 60% maximal inspiratory capacity using an inspiratory spirometer. RESULTS: Left hemidiaphragm displacement was successfully imaged by conventional M-mode sonography in only 70% (n = 35), as lung expansion obscured imaging, whereas 92% (n = 46) were assessable by angle-independent M-mode sonography. All right hemidiaphragm displacement could be assessed. Conventional M-mode results were higher than angle-independent M-mode results on the right (mean ± SD, 4.9 ± 1.4 versus 4.6 ± 1.2 cm, respectively; P= .003) and left (5.4 ± 1.3 versus 4.6 ± 1.0 cm; P < .001). Displacement values were different for right versus left hemidiaphragms on conventional M-mode sonography (mean difference, 0.6 ± 0.2 cm; P = .005), with only mild agreement (R2 = 0.35; P < .001). There was no laterality seen in the diaphragm displacement on angle-independent M-mode sonography (mean difference, 0.1 ± 0.1 cm; P = .47), with good agreement (R2 = 0.76; P < .001). CONCLUSIONS: Angle-independent M-mode sonography leads to better visualization and assessment of the left hemidiaphragm. It records lower displacement than conventional M-mode sonography in the bilateral diaphragms, likely because of fewer orientation and translation errors. Future study is indicated to assess the clinical utility of angle-independent M-mode sonography in a population with diaphragm dysfunction.


Assuntos
Diafragma/diagnóstico por imagem , Diafragma/fisiologia , Ultrassonografia/métodos , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Projetos Piloto , Valores de Referência , Reprodutibilidade dos Testes
18.
BMC Anesthesiol ; 15: 49, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25873786

RESUMO

BACKGROUND: Right ventricle (RV) dysfunction and hypotension can be induced by high levels of positive end-expiratory pressure (PEEP). We sought to determine in an animal model if a novel ultrasound analysis technique: speckle tracking echocardiography (STE), could determine deterioration in RV function induced by PEEP and to compare this to a conventional method of RV analysis: fractional area change (FAC). STE is a sensitive, angle-independent method for describing cardiac deformation ('strain') and is particularly useful in analyzing RV function as has been shown in pulmonary hypertension cohorts. METHODS: Ten pigs, 40-90 kg, anaesthetized, fully mechanically ventilated at 6 ml/kg were subject to step-wise escalating levels of PEEP at two-minute intervals (0, 5, 10, 15, 20, 25 and 30 cmH20). Intracardiac echocardiography was used to image the RV as transthoracic and transesophageal echocardiography did not give sufficient image quality or flexibility. Off-line STE analysis was performed using Syngo Velocity Vector Imaging (Seimens Medical Solutions Inc., USA). STE systolic parameters are RV free wall strain (RVfwS) and strain rate (RVfwSR) and the diastolic parameter RV free wall strain rate early relaxation (RVfwSRe). RESULTS: With escalating levels of PEEP there was a clear trend of reduction in STE parameters (RVfwS, RVfwSR, RVfwSRe) and FAC. Significant hypotension (fall in mean arterial blood pressure of 20 mmHg) occurred at approximately PEEP 15 cmH2O. Comparing RVfwS, RVfwSR and RVfwSRe values at different PEEP levels showed a significant difference at PEEP 0 cmH2O vs PEEP 10 cmH2O and above. FAC only showed a significant difference at PEEP 0 cmH2O vs PEEP 20 cmH2O and above. 30% of pigs displayed dyssychronous RV free wall contraction at the highest PEEP level reached. CONCLUSIONS: STE is a sensitive method for determining RV dysfunction induced by PEEP and deteriorated ahead of a conventional assessment method: FAC. RVfwS decreased to greater extent compared to baseline than FAC, earlier in the PEEP escalation process and showed a significant decrease before there was a clinical relevant decrease in mean arterial blood pressure. Studies in ICU patients using transthoracic echocardiography are warranted to further investigate the most sensitive echocardiography method for detecting RV dysfunction induced by mechanical ventilation.


Assuntos
Respiração com Pressão Positiva/efeitos adversos , Disfunção Ventricular Direita/etiologia , Análise de Variância , Animais , Pressão Sanguínea/fisiologia , Ecocardiografia/métodos , Feminino , Variações Dependentes do Observador , Oxigênio/sangue , Pressão Parcial , Estresse Fisiológico/fisiologia , Sus scrofa , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita/fisiologia
19.
Crit Care ; 18(4): R149, 2014 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-25015102

RESUMO

INTRODUCTION: Speckle tracking echocardiography (STE) is a relatively novel and sensitive method for assessing ventricular function and may unmask myocardial dysfunction not appreciated with conventional echocardiography. The association of ventricular dysfunction and prognosis in sepsis is unclear. We sought to evaluate frequency and prognostic value of biventricular function, assessed by STE in patients with severe sepsis or septic shock. METHODS: Over an eighteen-month period, sixty patients were prospectively imaged by transthoracic echocardiography within 24 hours of meeting severe sepsis criteria. Myocardial function assessment included conventional measures and STE. Association with mortality was assessed over 12 months. RESULTS: Mortality was 33% at 30 days (n = 20) and 48% at 6 months (n = 29). 32% of patients had right ventricle (RV) dysfunction based on conventional assessment compared to 72% assessed with STE. 33% of patients had left ventricle (LV) dysfunction based on ejection fraction compared to 69% assessed with STE. RV free wall longitudinal strain was moderately associated with six-month mortality (OR 1.1, 95% confidence interval, CI, 1.02-1.26, p = 0.02, area under the curve, AUC, 0.68). No other conventional echocardiography or STE method was associated with survival. After adjustment (for example, for mechanical ventilation) severe RV free wall longitudinal strain impairment remained associated with six-month mortality. CONCLUSION: STE may unmask systolic dysfunction not seen with conventional echocardiography. RV dysfunction unmasked by STE, especially when severe, was associated with high mortality in patients with severe sepsis or septic shock. LV dysfunction was not associated with survival outcomes.


Assuntos
Sepse/diagnóstico por imagem , Sepse/mortalidade , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/mortalidade , Idoso , Ecocardiografia/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Resultado do Tratamento
20.
JMIR Res Protoc ; 13: e52076, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38345834

RESUMO

BACKGROUND: Cardiopulmonary dysfunction is a complex process with a broad range of etiologies. Investigations performed either at rest or those that only assess the function of a single organ (heart or lungs) are often insufficient. A simultaneous cardiopulmonary exercise test with stress echocardiography is a new approach to assessing cardiopulmonary dysfunction as it provides anatomical and functional imaging simultaneously while under increasing stress. To date, the application of cardiopulmonary exercise test-stress echocardiography (CPET-SE) has been broad and without structure, and its effect on patient outcomes is unclear. OBJECTIVE: The objective of this scoping review is to explore and analyze the evidence regarding the role of simultaneous CPET-SE in investigating cardiopulmonary dysfunction in outpatients. It will include any published study in which adult (older than or equal to 18 years of age) patients have completed a CPET-SE for the investigation of cardiopulmonary dysfunction. METHODS: This review will follow the Arksey and O'Malley framework, supported by the Joanna Briggs Institute methodology for scoping reviews. It will use the PRISMA-ScR (Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews) checklist. Data sources will include MEDLINE, Scopus, Embase, and Cochrane (including reviews, trials, and protocols) electronic databases, with no date range defined. The search will be limited to the English language with no restrictions regarding pathology. Secondary references of the included sources will also be assessed by a hand search for suitability. A 2-person title-abstract screen and data charting process will be used. Independent experts will be used for consultation including an academic librarian and clinicians. The Covidence software will be used for article screening. RESULTS: This scoping review will provide a unified and detailed description of the applications of CPET-SE in investigating cardiopulmonary dysfunction. This will provide a platform for future research harnessing this investigatory method. The results will be presented in both tabular and graphical formats to ensure clarity. The results of this scoping review will be submitted to a relevant peer-reviewed academic journal for publication. CONCLUSIONS: The CPET-SE is a powerful tool for investigating cardiopulmonary dysfunction but remains in its infancy with a patchwork approach to indications, data reporting, and interpretation. This scoping review will unify the literature and provide a platform for future researchers and the development of a comprehensive application guideline. TRIAL REGISTRATION: Open Science Framework; https://osf.io/98r3e. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): PRR1-10.2196/52076.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA