Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 93(26): 9226-9234, 2021 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-34165288

RESUMO

Herein, a new strategy to increase the sensitivity of a lanthanide metal-organic framework (Ln-MOF) to UO22+ was proposed by using polymeric ligands. By utilizing [Tb(1,3,5-benzenetrisbenzoate)]n (Tb-TBT) MOF as the host, preloaded 2-vinyl terephthalic acid (VTP) was polymerized in situ, which produced a novel fluorescent composite denoted as PVTP⊂Tb-TBT. Benefiting from the coordination of PVTP to the Tb nodes, the polymeric chains performed both as molecular scaffolds that improved the water stability of the framework and as additional antennae that sensitized the photoluminescence of the Tb nodes. More importantly, the detection sensitivity and selectivity of PVTP⊂Tb-TBT to UO22+ were much improved compared to those of Tb-TBT. Detailed characterizations indicated that the incorporation of PVTP efficiently enriched UO22+ in the probe, which promoted the energy dissipation to UO22+. Besides, UO22+ was also supposed to release PVTP from PVTP⊂Tb-TBT and, thus, exposed the open metal sites to water molecules, which interrupted the sensitization effect of PVTP and induced a nonradiative energy dissipation. A limit of detection (LOD) as low as 0.75 nm was recorded by suspending the PVTP⊂Tb-TBT probe in a water sample, far below the limit in drinking water set by the United States Environmental Protection Agency (130 nm). Furthermore, a remotely controlled sampling and an on-site analysis of real water samples were realized by facilely loading PVTP⊂Tb-TBT on thin films (TFs). The LOD for UO22+ was 2.5 nm by using the TFs. This study reports a new strategy for boosting the sensitivity and selectivity of Ln-MOF to monitor UO22+ and expands the application of the strategy to an on-site analysis.


Assuntos
Elementos da Série dos Lantanídeos , Estruturas Metalorgânicas , Ligantes , Polímeros , Radioisótopos
2.
Anal Chim Acta ; 1220: 340040, 2022 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-35868701

RESUMO

Aromatic esters have been widely used in daily life with non-ignorable dangers, such as plasticizer, flavor, and preservative. Their wide applications and corresponding hazards caused by overuse have promoted the rapid development of sensitively analytical method for effective regulation. However, the variety makes it challenging for broad-spectrum and simultaneous extraction of diverse aromatic esters from the highly complex cosmetic samples. To our delight, a covalent organic framework, named DaTp (1, 3, 5-triformylphloroglucinol-2, 6-diaminoanthracene), possessing high specific surface, excellently thermochemical stability, and abundant electron-rich heteroatoms, has been synthesized and fabricated as a competitive solid phase microextraction coating for extracting the trace analytes with diverse polarity, through the hydrophobic interaction, π-π conjugation and hydrogen bond. Herein, this self-made SPME fiber has been further coupled with gas chromatography-tandem mass spectrometry (GC-MS) to determine the multi-polar aromatic esters in cosmetics packaged with plastic. This developed analytical method showed wide liner ranges, low limits of detection, good repeatability and reproducibility. Finally, the aromatic esters in four cosmetic samples were quantified precisely with satisfactory recoveries (80.7%-118%).


Assuntos
Cosméticos , Estruturas Metalorgânicas , Cosméticos/análise , Ésteres/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Limite de Detecção , Estruturas Metalorgânicas/química , Reprodutibilidade dos Testes , Microextração em Fase Sólida/métodos
3.
J Chromatogr A ; 1669: 462959, 2022 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-35303573

RESUMO

Perfluorinated alkyl substances (PFASs) were ubiquitously in the surface and groundwater. It is crucial and urgent to develop a rapid and ultrasensitive analysis method for the quantification of trace-level PFASs. Herein, a highly hydrophobic sorbent by capping phenylsilane groups on the surfaces of NH2-UiO-66(Zr) nanocrystals was used for efficient solid-phase microextraction (SPME) of PFASs in water samples. It was found that the superficially capped nanocrystals (NH2-UiO-66(Zr)-hp) exhibited both faster extraction kinetics and higher enrichment capacity than the non-capped nanocrystals. The extraction of eleven kinds of PFASs by NH2-UiO-66(Zr)-hp fiber reached equilibrium in 20 min. The enrichment factors of the NH2-UiO-66(Zr)-hp fiber ranged from 6.5 to 48, with a preference for long-chain PFASs over short-chain PFASs. It was proposed that superficial capping eliminated competitive moisture adsorption on the surfaces of the non-capped nanocrystals, thus facilitating the adsorption of PFASs through hydrophobic interaction. By using this new sorbent, the limits of detection of the SPME method as low as 0.035 to 0.616 ng·L-1 were achieved for the target PFASs. The recoveries of PFASs in the environmental water samples were 80.9%-120%. This study presents a new strategy for developing an efficient sorbent for PFASs by surface hydrophobic modification.


Assuntos
Estruturas Metalorgânicas , Ácidos Ftálicos , Poluentes Químicos da Água , Estruturas Metalorgânicas/química , Microextração em Fase Sólida/métodos , Poluentes Químicos da Água/análise
4.
Anal Chim Acta ; 1195: 339462, 2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35090656

RESUMO

The design and synthesis of novel high-performance solid phase microextraction (SPME) coatings towards organic pollutants with diverse chemical properties is still a challenge in sample preparation. Herein, a stable chitosan cross-linked graphene oxide (GOCS) aerogel was reported as a novel coating for solid phase microextraction. The interpenetrated meso- and macropores ensured the large surface area and high accessibility of the functional groups across the aerogel, resulting in high extraction performance towards target hydrophobic pollutants. The extraction capacities of the GOCS-coated SPME fiber towards analytes (e.g. polycyclic aromatic hydrocarbons, organophosphorus pesticides, organochlorine pesticides, pyrethroids, and polychlorinated biphenyls) were about 0.5-13 times as high as those obtained by the commercial fibers (30 µm polydimethylsiloxane (PDMS), 65 µm polydimethylsiloxane/divinylbenzene (PDMS/DVB)), which was attributed to the hydrophobic, π-π, halogen bond and hydrogen bond interactions between the coating and the analytes. Under the optimized extraction conditions, superior analytical performances for PAHs were achieved with a wide linearity (0.5-1000 ng L-1), high enhancement factors (311-3740), and the low limits of detection (0.03-1.28 ng L-1). Finally, the GOCS-coated SPME fiber was successfully applied to the determination of PAHs in real water samples with good recoveries (91.6%-110%).


Assuntos
Quitosana , Poluentes Ambientais , Praguicidas , Grafite , Compostos Organofosforados , Microextração em Fase Sólida
5.
Anal Chim Acta ; 1152: 338226, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33648643

RESUMO

Solid-phase extraction (SPE) is a popular technique for environmental sample pretreatment. However, SPE usually requires complex sample pretreatment processes, which is time-consuming and inconvenient for real-time and on-site monitoring. Herein, a solvent-free, rapid, and user-friendly SPE device was developed by coating the polydimethylsiloxane (PDMS)/divinylbenzene (DVB) sorbent on the inner wall of a sample bottle. The extraction process and desorption process were both carried out in the bottle. The analytes trapped in the sorbent were thermally desorbed and simultaneously sucked out from the bottle by an air sampling tube equipped on field-portable GC-MS. Different to previous work, the sample pretreatment process didn't require any complicated and time-consuming steps, such as centrifugation or filtration. The total analysis time for each sample was less than 25 min, which was feasible for rapid on-site detection, and thus avoided the losses and contamination of samples in conventional sample storage and transportation processes. Under optimal conditions, the proposed SPE method exhibited wide linear ranges, low detection limits (0.010-0.036 µg L-1, which were much lower than the maximum levels restricted by the US Environmental Protection Agency and the Chinese GB3838-2002 standard), good intra-bottle repeatability (6.13-7.17%, n = 3) and satisfactory inter-bottle reproducibility (4.73-6.47%, n = 3). Finally, the method was successfully applied to the rapid detection of BTEX in the field. The recoveries of BTEX in spiked water samples ranged from 89.1% to 116.2%. This work presents a novel SPE approach for rapid on-site monitoring in water samples.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA