Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Surg Clin North Am ; 104(5): 1083-1093, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39237165

RESUMO

Minimally invasive procedures minimize trauma to the human body while maintaining satisfactory therapeutic results. Minimally invasive pancreas surgery (MIPS) was introduced in 1994, but questions regarding its efficacy compared to an open approach were widespread. MIPS is associated with several perioperative advantages while maintaining oncological standards when performed by surgeons with a robust training regimen and frequent practice. Future research should focus on addressing learning curve discrepancies while identifying factors associated with shortening the time needed to attain technical proficiency.


Assuntos
Procedimentos Cirúrgicos Minimamente Invasivos , Pancreatectomia , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Pancreatectomia/métodos , Neoplasias Pancreáticas/cirurgia , Laparoscopia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Pâncreas/cirurgia , Curva de Aprendizado
2.
Polymers (Basel) ; 9(11)2017 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-30965872

RESUMO

High-resistance paper was manufactured by laccase-grafting of carboxymethyl cellulose (CMC) and chitosan (CPX) on Kraft pulp fiber. The reaction was mediated in the presence of laccase by one of the following polyphenols in the presence of air: gallic acid (GA), vanillic acid (VA) and catechol (1,2⁻DHB). Enzyme was added at constant loading (24 kg ton-1), 1% pulp consistency, 0.005% CMC, pH = 6.3 ± 0.5 and 2 mM of mediator. CPX content was assessed at two levels (0% and 0.005%). Treated pulps were analyzed by different mechanical tests (ring crush, mullen, corrugating medium test (CMT) flat crush of corrugating medium test and tension). An improvement in these parameters was obtained by biopolymer coupling and selected mediator. When using GA, three parameters increased more than 40%, while ring crush increased 120%. For the case of VA, properties were enhanced from 74% to 88% when CPX was added. For 1,2⁻DHB, there was not found a statistically significant difference between the results in the presence of CPX. Scanning electron microscopy, confocal microscopy, FTIR and 13C NMR were used in all papers in order to evaluate grafting. Hence, it was possible to correlate polymerization with an improvement of paper's mechanical properties.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA