Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Rev Esp Anestesiol Reanim ; 57(4): 224-35, 2010 Apr.
Artigo em Espanhol | MEDLINE | ID: mdl-20499801

RESUMO

Massive bleeding in obstetrics still ranks among the most frequent causes of maternal morbidity and mortality worldwide. The most frequent type is primary postpartum hemorrhage, which is usually the result of an atonic uterus. The clinical priorities are to assure hemodynamic stability and to correct coagulation abnormalities. If pharmacologic treatment cannot achieve these goals, invasive methods such as interventional vascular radiology or artery ligation must be used. Hysterectomy is the last resort when the previous methods fail. For the best prognosis, in terms of preventing death, maintaining maternal fertility and minimizing morbidity, every maternity ward should have a well-defined multidisciplinary protocol that facilitates diagnosis and immediate treatment.


Assuntos
Hemorragia Pós-Parto , Feminino , Humanos , Hemorragia Pós-Parto/etiologia , Hemorragia Pós-Parto/terapia
2.
J Clin Monit Comput ; 19(6): 383-9, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16437288

RESUMO

The BIS monitor (Aspect Medical Inc, Newton, USA) was the first electroencephalogram (EEG)-based monitor of the hypnotic effect reflected by a dimensionless figure ranging from 100 (awake state) to 0 (flat line EEG). Its widespread use makes it the most-studied and the best-known among same intended devices. Its algorithm processes low-frequency EEG oscillations in order to provide the Bispectral index. A BIS index ranging from 40 to 60 has been established as the proper for surgical performance. The BIS monitor permits a closer approach to the hypnotic component of anaesthesia beyond clinical signs and may reduce the probability of intraoperative awareness; therefore, it has become a recommended monitoring tool in routine practice. The SNAP monitor (Nicolet Biomedical, Madison WI, USA) is also intended for monitoring the hypnotic effect of anaesthetics, which is in turn displayed as an index ranging from 100 to 0, with 100 meaning a fully awake state and 0 meaning no brain activity. The algorithm of the SNAP monitor is featured by its additional processing of ultra-high EEG frequencies, which seem to be involved in the formation of consciousness. The use of these frequencies would theoretically improve responsiveness during increased brain activity. We studied its behaviour patterns and capability to monitor the hypnotic effect induced by sevoflurane-nitrous oxide by comparison with the BIS index. Seventy patients ASA I-III were induced with propofol, fentanyl and rocuronium, and maintained with sevoflurane-N(2)O. BIS and SNAP indices were simultaneously recorded before induction, after intubation, after incision, at the following 10, 30 and 50 minutes, awakening and extubation time points, together with heart rate and blood pressure. The Pearson correlation was R(2) = 0.68 (p < .05). The Bland and Altman test showed a bias of 14.3 for SNAP index values with respect to BIS index values. We concluded that the SNAP index correlates with variations in the hypnotic effect induced by sevoflurane-nitrous oxide anaesthesia when compared with the BIS index. In this context, a SNAP index ranging from 58 to 70 would be equivalent to the BIS index range 40 to 60 and, therefore, the accurate for surgical performance.


Assuntos
Anestésicos Combinados , Anestésicos Intravenosos , Eletroencefalografia , Éteres Metílicos , Monitorização Intraoperatória , Óxido Nitroso , Adulto , Anestesia por Inalação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sevoflurano , Vigília
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA