Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Blood Purif ; 52(11-12): 849-856, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37820591

RESUMO

INTRODUCTION: Hyperbilirubinemia is often the first evidence for any kind of liver disorder and over one-third of all patients in intensive care units (ICU) show elevated bilirubin concentrations. In critically ill patients, high concentrations of serum bilirubin are correlated with a poor outcome. Therapies to lower bilirubin concentrations are often just symptomatically and their effect on the patients' outcome is hardly evaluated. Therefore, this study investigates whether the extracorporeal elimination of bilirubin with the cytokine adsorber CytoSorb® (CS) reduces mortality in patients with hyperbilirubinemia. METHODS: Patients with bilirubin concentrations >10 mg/dL at the ICU were screened for evaluation from 2018 to 2020. Patients with kidney replacement therapy and older than 18 years were included. Patients with continuously decreasing bilirubin concentrations after liver transplantation or other liver support systems (i.e., Molecular Adsorbents Recirculating System [MARS®], Advanced Organ Support [ADVOS]) were excluded. CS therapy was used in clinical routine and was indicated by the treating physicians. Statistical analysis was performed with IBM SPSS statistics utilizing a multivariate model. Primary outcome measure was the effect of CS on the 30-day mortality. RESULTS: Data from 82 patients (mean Simplified Acute Physiology Score [SAPS] II: 74 points, mean bilirubin: 18 mg/dL, mean lactate: 3.7 mmol/L) were analyzed. There were no significant differences in patients with and without CS treatment. The multivariate model showed no significant effect of CS therapy (p = 0.402) on the 30-day mortality. In addition, a significant effect of bilirubin concentration (p = 0.274) or Model for End-Stage Liver Disease score (p = 0.928) on the 30-day mortality could not be shown. In contrast, lactate concentration (p = 0.001, b = 0.044) and SAPS II (p = 0.025, b = 0.008) had significant impact on 30-day mortality. CONCLUSION: The use of CS in patients with hyperbilirubinemia did not result in a significant reduction in 30-day mortality. Randomized and controlled studies with mortality as primary outcome measure are needed in the future to justify their use.


Assuntos
Bilirrubina , Doença Hepática Terminal , Humanos , Estado Terminal/terapia , Citocinas , Índice de Gravidade de Doença , Hiperbilirrubinemia/terapia , Lactatos , Estudos Retrospectivos
2.
Ren Fail ; 45(2): 2259231, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37728069

RESUMO

Severe rhabdomyolysis frequently results in acute kidney injury (AKI) due to myoglobin accumulation with the need of kidney replacement therapy (KRT). The present study investigated whether the application of Cytosorb® (CS) led to an increased rate of kidney recovery in patients with KRT due to severe rhabdomyolysis. Adult patients with a myoglobin-concentration >10,000 ng/ml and KRT were included from 2014 to 2021. Exclusion criteria were chronic kidney disease and CS-treatment before study inclusion. Groups 1 and 2 were defined as KRT with and without CS, respectively. The primary outcome parameter was independence from KRT after 30 days. Propensity score (PS) matching was performed (predictors: myoglobin, SAPS-II, and age), and the chi2-test was used. 35 pairings could be matched (mean age: 57 vs. 56 years; mean myoglobin: 27,218 vs. 26,872 ng/ml; mean SAPS-II: 77 vs. 76). The probability of kidney recovery was significantly (p = .04) higher in group 1 (31.4 vs. 11.4%, mean difference: 20.0%, odds ratio (OR): 3.6). Considering patients who survived 30 days, kidney recovery was also significantly (p = .03) higher in patients treated with CS (61.1 vs. 23.5%, mean difference: 37.6%, OR: 5.1). In conclusion, the use of CS might positively affect renal recovery in patients with severe rhabdomyolysis. A prospective randomized controlled trial is needed to confirm this hypothesis.


Assuntos
Estado Terminal , Rabdomiólise , Adulto , Humanos , Pessoa de Meia-Idade , Pontuação de Propensão , Estado Terminal/terapia , Mioglobina , Estudos Prospectivos , Rim , Rabdomiólise/complicações
3.
Antimicrob Agents Chemother ; 66(2): e0183121, 2022 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-34871092

RESUMO

Meropenem is one of the most frequently used antibiotics to treat life-threatening infections in critically ill patients. This study aimed to develop a meropenem dosing algorithm for the treatment of Gram-negative infections based on intensive care unit (ICU)-specific resistance data. Antimicrobial susceptibility testing of Gram-negative bacteria obtained from critically ill patients was carried out from 2016 to 2020 at a tertiary care hospital. Based on the observed MIC distribution, stochastic simulations (n = 1,000) of an evaluated pharmacokinetic meropenem model, and a defined pharmacokinetic/pharmacodynamic target (100%T>4×MIC while minimum concentrations were <44.5 mg/L), dosing recommendations for patients with varying renal function were derived. Pathogen-specific MIC distributions were used to calculate the cumulative fraction of response (CFR), and the overall MIC distribution was used to calculate the local pathogen-independent mean fraction of response (LPIFR) for the investigated dosing regimens. A CFR/LPIFR of >90% was considered adequate. The observed MIC distribution significantly differed from the EUCAST database. Based on the 6,520 MIC values included, a three-level dosing algorithm was developed. If the pathogen causing the infection is unknown (level 1), known (level 2), known to be neither Pseudomonas aeruginosa nor Acinetobacter baumannii, or classified as susceptible (level 3), a continuous infusion of 1.5 g daily reached sufficient target attainment independent of renal function. In all other cases, dosing needs to be adjusted based on renal function. ICU-specific susceptibility data should be assessed regularly and integrated into dosing decisions. The presented workflow may serve as a blueprint for other antimicrobial settings.


Assuntos
Antibacterianos , Estado Terminal , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Estado Terminal/terapia , Bactérias Gram-Negativas , Humanos , Meropeném/farmacocinética , Testes de Sensibilidade Microbiana
4.
Clin Chem Lab Med ; 60(7): 995-1002, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35499915

RESUMO

OBJECTIVES: Diagnostic samples are exposed to a spectrum of variables during transport to laboratories; therefore, the evaluation of a rather comprehensive stability profile of measurands is warranted. While appropriate testing standards have been established for pharmaceuticals and reagents, this is not the case for diagnostic samples. The aim of our work was to develop and evaluate a protocol applicable to diagnostic samples. METHODS: An isochronous approach with representation of temperature and exposure duration in a two-dimensional matrix was established. The deviations of the measurement results from the baseline associated with the exposure are evaluated with respect to the measurement uncertainty of the analytical measurement procedure applied. Variables of the experiment are documented in a standardized matrix. As a proof-of-concept, we profiled the stability patterns of a number of measurands at four temperature levels over up to 72 h in primary serum sample tubes. RESULTS: The protocol proved to be workable and allowed the description of a comprehensive stability profile of a considerable number of compounds based on 21 small-volume primary samples collected from each volunteer and exposed according to this protocol. CONCLUSIONS: A straightforward and feasible isochronous protocol can be used to investigate in detail the effects of different pre-processing conditions on the stability of measurands in primary samples during transport to diagnostic laboratories. This is of significance as pre-analytical logistics become increasingly important with the centralization of analytical services.


Assuntos
Laboratórios , Humanos , Padrões de Referência , Incerteza
5.
Clin Chem Lab Med ; 60(1): 82-91, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-34668357

RESUMO

OBJECTIVES: Cystic fibrosis (CF) transmembrane conductance regulator (CFTR) modulators have revolutionized the therapeutic landscape in CF treatment. These vital drugs are extensively metabolized via CYP3A, so caution must be exercised in multimodal CF therapy because of the risk of adverse drug interactions. Our goal was to develop a highly sensitive assay for the purpose of therapeutic drug monitoring (TDM) in diagnostic laboratories. METHODS: After protein precipitation, the CFTR modulators ivacaftor, lumacaftor, tezacaftor, elexacaftor, and their metabolites ivacaftor-M1, ivacaftor-M6, and tezacaftor-M1 were separated with a two-dimensional chromatography setup within 5 min, and quantified with stable isotope-labeled internal standards. The method was validated according to the European Medicines Agency (EMA) guideline on bioanalytical method validation and applied to CF patient samples. RESULTS: Inaccuracy was ≤7.0% and the imprecision coefficient of variation (CV) was ≤8.3% for all quality controls (QCs). The method consistently compensated for matrix effects, recovery, and process efficiency were 105-115 and 96.5-103%, respectively. Analysis of CF serum samples provided concentrations comparable to the pharmacokinetic profile data reported in the EMA assessment report for the triple combination therapy Kaftrio. CONCLUSIONS: We hereby present a robust and highly selective isotope dilution liquid chromatography tandem mass spectrometry (ID-LC-MS/MS) assay for the simultaneous quantification of the so far approved CFTR modulators and their metabolites in human serum. The assay is suitable for state-of-the-art pharmacovigilance of CFTR modulator therapy in CF patients, in order to maximize safety and efficacy, and also to establish dose-response relationships in clinical trials.


Assuntos
Regulador de Condutância Transmembrana em Fibrose Cística , Fibrose Cística , Aminofenóis , Aminopiridinas , Benzodioxóis , Cromatografia Líquida , Fibrose Cística/tratamento farmacológico , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Humanos , Indóis , Isótopos , Mutação , Pirazóis , Piridinas , Pirrolidinas , Quinolonas , Espectrometria de Massas em Tandem
6.
Antimicrob Agents Chemother ; 65(12): e0156421, 2021 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-34570645

RESUMO

Pneumonia is one of the most common infections in intensive care patients, and it is often treated with beta-lactam antibiotics. Even if therapeutic drug monitoring in blood is available, it is unclear whether sufficient concentrations are reached at the target site: the lung. The present study was initiated to fill this knowledge gap. Various compartments from 10 patients' explanted lungs were subjected to laboratory analysis. Meropenem was quantified in serum, bronchoalveolar lavage (BAL) fluid, microdialysate, and homogenized lung tissue with isotope dilution liquid chromatography tandem mass spectrometry (ID-LC-MS/MS). BAL fluid represents diluted epithelial lining fluid (ELF), and microdialysate represents interstitial fluid (IF). Differences between target site and blood concentrations were investigated. The median meropenem concentration in blood, ELF, IF, and tissue were 26.8, 18.0, 12.1, and 9.1 mg/liter, respectively. A total of 37.5% of the target site ELF and IF meropenem concentrations were below the clinical EUCAST breakpoint of 8 mg/liter. The median ELF/serum quotient was 61.8% (interquartile range [IQR], 24.8% to 87.6%), the median IF/serum quotient was 35.4% (IQR, 23.8% to 54.3%), and the median tissue/serum quotient was 34.2% (IQR, 28.3% to 38.2%). We observed a substantial interindividual variability between the blood and the compartments (ELF and IF), whereas the intraindividual variability was relatively low. Target site measurement in different lung compartments was feasible and successfully applied in a clinical setting. A relevant amount of 37.5% of the target site concentrations were below the clinical EUCAST breakpoint, indicating subtherapeutic dosing in high-risk patients receiving perioperative antibiotic prophylaxis in lung transplantation. (This study has been registered at ClinicalTrials.gov under identifier NCT03970265.).


Assuntos
Pulmão , Espectrometria de Massas em Tandem , Antibacterianos/uso terapêutico , Lavagem Broncoalveolar , Líquido da Lavagem Broncoalveolar , Cromatografia Líquida , Humanos , Meropeném , Microdiálise
7.
Transpl Infect Dis ; 23(4): e13675, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34166573

RESUMO

BACKGROUND: Posaconazole and itraconazole are commonly used for systemic antifungal prophylaxis after lung transplantation. The aim of this study on critically ill lung transplant recipients was to assess the rate of adequate plasma concentrations and the frequency of fungal-induced transitions from antifungal prophylaxis to therapy after the administration of either posaconazole or itraconazole for systemic prophylaxis. METHODS: Critically ill lung transplant recipients with postoperative posaconazole or itraconazole prophylaxis and therapeutic drug monitoring from February 2016 to November 2019 were retrospectively included in the study. Positive fungal cultures or Aspergillus antigen tests resulting in a transition from antifungal prophylaxis to therapy were analyzed from the first day of prophylaxis until 7 days after the last sample for each patient. Adequate plasma concentrations were defined as ≥500 µg/L for itraconazole and ≥700 µg/L for posaconazole. RESULTS: Two hundred seventy-five samples from 73 patients were included in the analysis. Overall, 60% of the posaconazole and 55% of the itraconazole concentrations were subtherapeutic. Administration of posaconazole suspension resulted significantly (P < .01) more often in subtherapeutic concentrations than tablets (68% vs 10%). Patients treated with posaconazole showed less positive fungal records resulting in a transition from prophylaxis to therapy than patients treated with itraconazole (10% vs 33%, P-value: .029). The detection of a fungal pathogen was not associated with the measured plasma concentrations or the achievement of the target concentrations. CONCLUSION: Our findings suggest that posaconazole should be used instead of itraconazole for systemic prophylaxis in critically ill lung transplant recipients.


Assuntos
Antifúngicos , Itraconazol , Antifúngicos/uso terapêutico , Estado Terminal , Humanos , Itraconazol/uso terapêutico , Pulmão , Estudos Retrospectivos , Transplantados , Triazóis
8.
Crit Care ; 25(1): 41, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33509234

RESUMO

BACKGROUND: Rhabdomyolysis is frequently occurring in critically ill patients, resulting in a high risk of acute kidney injury (AKI) and potentially permanent kidney damage due to increased myoglobin levels. The extracorporeal elimination of myoglobin might be an approach to prevent AKI, but its molecular weight of 17 kDa complicates an elimination with conventional dialysis membranes. Question of interest is, if myoglobin can be successfully eliminated with the cytokine adsorber Cytosorb® (CS) integrated in a high-flux dialysis system. METHODS: Patients were included between 10/2014 and 05/2020 in the study population if they had an anuric renal failure with the need of renal replacement therapy, if CS therapy was longer than 90 min and if myoglobin level was > 5.000 ng/ml before treatment. The measurement times of the laboratory values were: d-1 = 24-36 h before CS, d0 = shortly before starting CS and d1 = 12-24 h after starting CS treatment. Statistical analysis were performed with Spearman's correlation coefficient, Wilcoxon test with associated samples and linear regression analysis. RESULTS: Forty-three patients were included in the evaluation (median age: 56 years, 77% male patients, 32.6% ECMO therapy, median SAPS II: 80 points and in-hospital mortality: 67%). There was a significant equilateral correlation between creatine kinase (CK) and myoglobin at all measurement points. Furthermore, there was a significant reduction of myoglobin (p = 0.03, 95% confidence interval (CI): - 9030, - 908 ng/ml) during CS treatment, with a median relative reduction of 29%. A higher median reduction of 38% was seen in patients without ongoing rhabdomyolysis (CK decreased during CS treatment, n = 21). In contrast, myoglobin levels did not relevantly change in patients with increasing CK and therefore ongoing rhabdomyolysis (n = 22, median relative reduction 4%). Moreover, there was no significant difference in myoglobin elimination in patients with and without ECMO therapy. CONCLUSION: Blood purification with Cytosorb® during high-flux dialysis led to a significant reduction of myoglobin in patients with severe rhabdomyolysis. The effect might be obscured by sustained rhabdomyolysis, which was seen in patients with rising CK during treatment. Prospective clinical trials would be useful in investigating its benefits in avoiding permanent kidney damage.


Assuntos
Citocinas/metabolismo , Mioglobina/metabolismo , Reabsorção Renal , Rabdomiólise/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estado Terminal/terapia , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Mioglobina/efeitos adversos , Estudos Prospectivos , Terapia de Substituição Renal/métodos , Estudos Retrospectivos , Rabdomiólise/fisiopatologia
9.
Clin Chem Lab Med ; 59(1): 147-154, 2020 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-32716904

RESUMO

Objectives: The risk of sample confusion continues to be a challenge for the pre-analytical part of the overall testing process. We here describe a novel system to track samples based on a chemical code labeling of test tubes with unique combinations of indicator compounds, which are naturally not present in specimens of human origin. As part of the sample vessel filling, the liquid specimens are permanently labeled with the compound code that can be tracked back to the primary tube. Methods: As a proof of concept we used 10 stable-isotope-labeled derivates of medical drugs as indicator substances to create a combinatory 10-digit binary number ID for individual test tubes, i.e. presence/absence of the respective compound. For this purpose, combinations of indicator compounds were provided in evaporated form in polypropylene tubes prior to filling with anonymized patient whole blood and corresponding plasmas subjected to liquid chromatography tandem-mass spectrometry designed to detect the 10 indicator compounds. Results: In the blind analysis, we correctly identified 307 different whole blood samples by readout of a 10-digit binary number ID based on the detection of indicator compounds with respect to their presence and number. Conclusions: We have demonstrated the feasibility of an internal labeling procedure for diagnostic samples with mass spectrometry-based readout of dissolved indicator compound combinations as a binary number ID. With an increasing number of coding compounds (≫10) a vast number of combinations for sample labeling can be realized beyond the proof of concept setting studied herein.


Assuntos
Coleta de Amostras Sanguíneas/métodos , Indicadores e Reagentes/química , Manejo de Espécimes/métodos , Cromatografia Líquida , Deutério/química , Estudos de Viabilidade , Humanos , Estudo de Prova de Conceito , Espectrometria de Massas em Tandem
10.
Clin Chem Lab Med ; 58(9): 1469-1476, 2020 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-32229659

RESUMO

Background: Appropriate monitoring of tobacco smoking is extremely important in several areas of medicine, e.g. management of chronic obstructive pulmonary disease (COPD), epidemiological surveys, and allocation of heart or lung transplants. The major metabolite of nicotine is cotinine that is increasingly used as a laboratory parameter for assessing tobacco smoke exposure. Methods: Creatinine and cotinine were analyzed simultaneously in urine by ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) in one run within 3 min using a biphenyl column. For quantification, the respective stable-isotope-labeled standards were used. Results: Detuning and measuring a natural isotope of creatinine as precursor and product ion allowed a simultaneous quantification of creatinine and cotinine. The method revealed robust validation results. For both analytes, inaccuracy and imprecision of the quality control and external quality assessment (EQA) samples were ≤-11.1%. Conclusions: One essential novelty of the method presented here is the simultaneous quantification of creatinine and cotinine covered by one analytical method. Despite the very different natural concentrations of creatinine and cotinine, this allows the immediate reporting of the cotinine-to-creatinine ratio without the need for a separate creatinine analysis.


Assuntos
Cromatografia Líquida/métodos , Cotinina/urina , Creatinina/urina , Espectrometria de Massas em Tandem/métodos , Humanos , Isótopos/química , Reprodutibilidade dos Testes
11.
Clin Lab ; 66(4)2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32255280

RESUMO

BACKGROUND: Therapeutic drug monitoring (TDM) of the immunosuppressant mycophenolic acid (MPA) is especially recommended for the control of personalized immunosuppressive therapy. Various test systems are available for MPA monitoring, including high performance liquid chromatography combined with UV detection (HPLC-UV) and isotope dilution liquid chromatography tandem mass spectrometry (ID-LC-MS/MS). METHODS: In the present work, commercially available kits for MPA monitoring with HPLC-UV and ID-LC-MS/ MS were subjected to routine use TDM. Following method verification according to the Clinical and Laboratory Standards Institute (CLSI) guidelines, 105 native sample duplicates from patients under therapy with mycophenolate mofetil were assayed with both procedures for comparative testing. RESULTS: Using bi-level quality controls, the estimate of repeatability, within-laboratory imprecision and inaccuracy were ≤ 5.18%, ≤ 5.95% and ≤ 3.86% for all MPA measurements. Weighted Deming regression analysis yielded a slope of 0.93, an intercept of 0.04, and Pearson's correlation coefficient (r) of 0.99, while Bland-Altman analysis showed a combined relative bias of 4.93% (± 1.96 SD: -16.68 - 26.54%). Plasma samples taken from a patient re-peatedly showed the presence of an interferent only in HPLC-UV analysis. CONCLUSIONS: Based on these results, HPLC-UV testing can be considered suitable for routine TDM of MPA in the clinical setting with high precision. Due to the risk of unforeseen analytical interference in ever-increasing multimorbidity and polypharmacy, highly selective ID-LC-MS/MS methodology should be given preference over HPLC-UV analysis whenever feasible.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Monitoramento de Medicamentos/métodos , Ácido Micofenólico/sangue , Espectrofotometria Ultravioleta/métodos , Espectrometria de Massas em Tandem/métodos , Humanos , Imunossupressores/sangue , Imunossupressores/uso terapêutico , Ácido Micofenólico/uso terapêutico , Radioisótopos/metabolismo , Reprodutibilidade dos Testes
12.
Clin Lab ; 65(9)2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31532096

RESUMO

BACKGROUND: Therapeutic drug monitoring (TDM) of beta-lactam antibiotics has become a valuable tool to guide dosing in critically ill patients. The main goal of the study was to compare two routinely used techniques for beta-lactam TDM in intensive care unit (ICU) patient samples, namely isotope dilution liquid chromatography tandem mass spectrometry (ID-LC-MS/MS) and high-performance liquid chromatography combined with ultra-violet detection (HPLC-UV). METHODS: A set of 80 sera/plasma samples from ICU patients receiving therapeutic meropenem or piperacillin dosage was investigated. Sample duplicates and quality assessment samples were assayed in parallel with an in-house LC-MS/MS and a commercially available IVD HPLC-UV kit. A pharmacokinetic and pharmacodynamic (PK/PD) target with ≥ 22.5 mg/L for piperacillin and ≥ 8.0 mg/L for meropenem was used for medical assessment of trough sample (n = 40) antibiotic concentrations. RESULTS: There was no difference between serum and Li-heparin plasmas. Concentration deviations were found for 4% of meropenem and 17% of piperacillin samples. Eliminating the influence of the systemic bias of approximately 10% for piperacillin, measurement discrepancies ≥ 25% between LC-MS/MS and HPLC-UV analyses were only observed for ≈ 4 - 6% of all samples. In the same way, identical PK/PD target attainment rates of 50 - 60% could be obtained. CONCLUSIONS: After correction of the analytical bias for piperacillin measurements, both methods showed comparable results, also with respect to clinical decision limits. HPLC-UV analysis is an adequate TDM methodology for testing of beta-lactam antibiotics in centers where no special knowledge in LC-MS/MS based TDM is present. However, potential matrix effects, interferences, and calibration issues for both methods must be taken into account.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Estado Terminal , Meropeném/uso terapêutico , Piperacilina/uso terapêutico , Espectrometria de Massas em Tandem/métodos , Antibacterianos/sangue , Antibacterianos/farmacocinética , Antibacterianos/uso terapêutico , Cromatografia Líquida de Alta Pressão/instrumentação , Cuidados Críticos/métodos , Monitoramento de Medicamentos/métodos , Humanos , Meropeném/sangue , Meropeném/farmacocinética , Piperacilina/sangue , Piperacilina/farmacocinética , Reprodutibilidade dos Testes , Raios Ultravioleta
14.
Clin Lab ; 64(10): 1695-1700, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30336519

RESUMO

BACKGROUND: The adrenocorticotropic hormone (ACTH) stimulation test is a widely used diagnostic tool to assess the adrenal gland function. Beyond that the ACTH test can be used in stress research to induce a biochemical stress response under standardized conditions. To study the impact of the stress response on protein metabolism, time-course plasma amino acid profiling in healthy individuals was performed with high performance liquid chromatography tandem-mass spectrometry (HPLC-MS/MS). METHODS: A set of 39 samples (pre/post 30´ and 60´ IV-ACTH) from 13 healthy individuals (age range 26 - 58, 3 female and 10 male) was investigated. Plasma amino acids were quantified by LC-MS/MS using the AbsoluteIDQ® p180 Kit (Biocrates Life Science, Innsbruck, Austria) including 19 biogenic amino acids, ornithine, and citrulline. RESULTS: Statistically significant decreases were observed for 11 proteinogenic amino acids (alanine, asparagine, isoleucine, leucine, tyrosine, phenylalanine, tryptophan, valine, methionine, aspartate, and threonine). The amino acids alanine, asparagine, and isoleucine showed markedly pronounced relative changes with short-term reduction of median inter-individual plasma concentrations of up to 25%. CONCLUSIONS: Amino acid profiling with LC-MS/MS revealed highly dynamic plasma alterations upon application of exogenous corticotropin as a stress model. Our findings provide novel insights into the biochemical stress response and improve our understanding of short-term metabolic consequences. Further studies should elucidate the impact of corticotropin mediated stress responses on amino acid catabolism.


Assuntos
Hormônio Adrenocorticotrópico/administração & dosagem , Aminoácidos/metabolismo , Metaboloma/efeitos dos fármacos , Metabolômica , Adulto , Aminoácidos/sangue , Cromatografia Líquida , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Espectrometria de Massas em Tandem , Fatores de Tempo
18.
Front Pharmacol ; 15: 1346343, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38362152

RESUMO

Accurate assessment of renal function is of great clinical and scientific importance, as it is an important pharmacokinetic covariate of pivotal drugs. The iohexol clearance is nearly identical to the glomerular filtration rate, but its determination usually requires an intravenous injection and therefore bears intrinsic risks. This motivates to showcase an "en passant" approach to quantification of renal function without additional risk or blood sampling beyond routine care using real-world data. We enrolled 37 intensive care patients who received high doses of iohexol for computed tomography imaging, and quantified series of iohexol plasma concentrations by high-performance liquid chromatography (HPLC-UV). Iohexol clearance was derived by both log-linear regression and nonlinear least squares fitting and compared to glomerular filtration rate estimated by the CKD-EPI-2021 formulas. Nonlinear fitting not only turned out to be more accurate but also more robust in handling the irregularly timed data points. Concordance of iohexol clearance against estimations based on both creatinine and cystatin C showed a slightly higher bias (-3.44 mL/min/1.73 m2) compared to estimations based on creatinine alone (-0.76 mL/min/1.73 m2), but considerably narrower limits of agreement (±42.8 vs. 56 mL/min/1.73 m2) and higher Lin's correlation (0.84 vs. 0.72). In summary, we have demonstrated the feasibility and performance of the "en passant" variant of the iohexol method in intensive care medicine and described a working protocol for its application in clinical practice and pharmacologic studies.

19.
Ann Intensive Care ; 14(1): 96, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38907120

RESUMO

BACKGROUND: Rhabdomyolysis is a serious condition that can lead to acute kidney injury with the need of renal replacement therapy (RRT). The cytokine adsorber Cytosorb® (CS) can be used for extracorporeal myoglobin elimination in patients with rhabdomyolysis. However, data on adsorption capacity and saturation kinetics are still missing. METHODS: The prospective Cyto-SOLVE study (NCT04913298) included 20 intensive care unit patients with severe rhabdomyolysis (plasma myoglobin > 5000 ng/ml), RRT due to acute kidney injury and the use of CS for myoglobin elimination. Myoglobin and creatine kinase (CK) were measured in the patient´s blood and pre- and post-CS at defined time points (ten minutes, one, three, six, and twelve hours after initiation). We calculated Relative Change (RC, %) with: [Formula: see text]. Myoglobin plasma clearances (ml/min) were calculated with: [Formula: see text] RESULTS: There was a significant decrease of the myoglobin plasma concentration six hours after installation of CS (median (IQR) 56,894 ng/ml (11,544; 102,737 ng/ml) vs. 40,125 ng/ml (7879; 75,638 ng/ml) (p < 0.001). No significant change was observed after twelve hours. Significant extracorporeal adsorption of myoglobin can be seen at all time points (p < 0.05) (ten minutes, one, three, six, and twelve hours after initiation). The median (IQR) RC of myoglobin at the above-mentioned time points was - 79.2% (-85.1; -47.1%), -34.7% (-42.7;-18.4%), -16.1% (-22.1; -9.4%), -8.3% (-7.5; -1.3%), and - 3.9% (-3.9; -1.3%), respectively. The median myoglobin plasma clearance ten minutes after starting CS treatment was 64.0 ml/min (58.6; 73.5 ml/min), decreasing rapidly to 29.1 ml/min (26.5; 36.1 ml/min), 16.1 ml/min (11.9; 22.5 ml/min), 7.9 ml/min (5.5; 12.5 ml/min), and 3.7 ml/min (2.4; 6.4 ml/min) after one, three, six, and twelve hours, respectively. CONCLUSION: The Cytosorb® adsorber effectively eliminates myoglobin. However, the adsorption capacity decreased rapidly after about three hours, resulting in reduced effectiveness. Early change of the adsorber in patients with severe rhabdomyolysis might increase the efficacy. The clinical benefit should be investigated in further clinical trials. TRIAL REGISTRATION: ClinicalTrials.gov NCT04913298. Registered 07 May 2021, https//clinicaltrials.gov/study/NCT04913298.

20.
Intensive Care Med Exp ; 12(1): 47, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38717627

RESUMO

BACKGROUND: Therapeutic drug monitoring (TDM) of anti-infectives such as linezolid is routinely performed in blood of intensive care unit (ICU) patients to optimize target attainment. However, the concentration at the site of infection is considered more important for a successful therapy. Until now, bronchoalveolar lavage (BAL) is the gold standard to measure intrapulmonary concentrations of anti-infective agents. However, it is an invasive method and unsuitable for regular TDM. The aim of this proof-of-concept study was to investigate whether it is possible to reliably determine the intrapulmonary concentration of linezolid from endotracheal aspiration (ENTA). METHODS: Intubated ICU patients receiving 600 mg intravenous linezolid twice daily were examined in steady state. First, preliminary experiments were performed in six patients to investigate which patients are suitable for linezolid measurement in ENTA. In a second step, trough and peak linezolid concentrations of plasma and ENTA were determined in nine suitable patients. RESULTS: Linezolid can validly be detected in ENTA with viscous texture and > 0.5 mL volume. The mean (SD) linezolid trough concentration was 2.02 (1.27) mg/L in plasma and 1.60 (1.36) mg/L in ENTA, resulting in a median lung penetration rate of 104%. The mean (SD) peak concentration in plasma and ENTA was 10.77 (5.93) and 4.74 (2.66) mg/L. CONCLUSIONS: Linezolid can validly be determined in ENTA with an adequate texture and volume. The penetration rate is comparable to already published BAL concentrations. This method might offer a simple and non-invasive method for TDM at the site of infection "lung". Due to promising results of the feasibility study, comparison of ENTA and BAL in the same patient should be investigated in a further trial.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA