Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
Proc Natl Acad Sci U S A ; 120(10): e2216678120, 2023 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-36857346

RESUMO

Low-light imaging is challenging in regimes where low-noise detectors are not yet available. One such regime is the shortwave infrared where even the best multipixel detector arrays typically have a noise floor in excess of 100 photons per pixel per frame. We present a homodyne imaging system capable of recovering both intensity and phase images of an object from a single frame despite an illumination intensity of ≈​1 photon per pixel. We interfere this weak signal which is below the noise floor of the detector with a reference beam that is ∼​300, 000 times brighter, record the resulting interference pattern in the spatial domain on a detector array, and use Fourier techniques to extract the intensity and phase images. We believe our approach could vastly extend the range of applications for low-light imaging by accessing domains where low-noise cameras are not currently available and for which low-intensity illumination is required.

2.
Opt Express ; 24(13): 14172-82, 2016 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-27410575

RESUMO

Computational ghost imaging (CGI) enables an image to be recorded using a single-pixel detector. The image can be reconstructed from correlations between the scene and a series of known projected intensity patterns. In this work we investigate the performance of CGI using pseudo non-diffracting (ND) speckle patterns. We demonstrate an extended depth-of-field that is ∼ 2-3 times greater than that achievable with conventional speckle, when only computing each intensity pattern to a single depth. In addition, the average speckle grain size of ND speckle is reduced by a factor of ∼ 1.5 relative to conventional speckle, which enhances the lateral Rayleigh-limit resolving power of our reconstructed images. However, the point-spread function (PSF) of our imaging system takes the form of a Bessel beam, which manifests itself as long-range correlations between speckle grains in the projected patterns. We discuss the trade-off between enhancement of the depth-of-field and the lateral resolution when using ND speckle, at the expense of a reduction in image contrast. Our work demonstrates that the tailoring of lateral and axial correlations in projected intensity patterns permits PSF engineering in CGI.

3.
Opt Express ; 24(23): 27009-27015, 2016 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-27857428

RESUMO

We demonstrate that Digital Holographic Microscopy can be used for accurate 3D tracking and sizing of a colloidal probe trapped in a diamond anvil cell (DAC). Polystyrene beads were optically trapped in water up to Gigapascal pressures while simultaneously recording in-line holograms at 1 KHz frame rate. Using Lorenz-Mie scattering theory to fit interference patterns, we detected a 10% shrinking in the bead's radius due to the high applied pressure. Accurate bead sizing is crucial for obtaining reliable viscosity measurements and provides a convenient optical tool for the determination of the bulk modulus of probe material. Our technique may provide a new method for pressure measurements inside a DAC.

4.
Opt Express ; 23(25): 31716-27, 2015 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-26698964

RESUMO

When a microscopic particle moves through a low Reynolds number fluid, it creates a flow-field which exerts hydrodynamic forces on surrounding particles. In this work we study the 'Lissajous-like' trajectories of an optically trapped 'probe' microsphere as it is subjected to time-varying oscillatory hydrodynamic flow-fields created by a nearby moving particle (the 'actuator'). We show a breaking of time-reversal symmetry in the motion of the probe when the driving motion of the actuator is itself time-reversal symmetric. This symmetry breaking results in a fluid-pumping effect, which arises due to the action of both a time-dependent hydrodynamic flow and a position-dependent optical restoring force, which together determine the trajectory of the probe particle. We study this situation experimentally, and show that the form of the trajectories observed is in good agreement with Stokesian dynamics simulations. Our results are related to the techniques of active micro-rheology and flow measurement, and also highlight how the mere presence of an optical trap can perturb the environment it is in place to measure.

5.
Opt Express ; 22(4): 4671-7, 2014 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-24663785

RESUMO

We demonstrate a new method for measuring the sedimentation of a single colloidal bead by using a combination of optical tweezers and a stereo microscope based on a spatial light modulator. We use optical tweezers to raise a micron-sized silica bead to a fixed height and then release it to observe its 3D motion while it sediments under gravity. This experimental procedure provides two independent measurements of bead diameter and a measure of Faxén's correction, where the motion changes due to presence of the boundary.

6.
Opt Express ; 22(15): 18662-7, 2014 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-25089484

RESUMO

High-speed video stereo-microscopy relies on illumination from two distinct angles to create two views of a sample from different directions. The 3D trajectory of a microscopic object can then be reconstructed using parallax to combine 2D measurements of its position in each image. In this work, we evaluate the accuracy of 3D particle tracking using this technique, by extending the number of views from two to four directions. This allows us to record two independent sets of measurements of the 3D coordinates of tracked objects, and comparison of these enables measurement and minimisation of the tracking error in all dimensions. We demonstrate the method by tracking the motion of an optically trapped microsphere of 5 µm in diameter, and find an accuracy of 2-5 nm laterally, and 5-10 nm axially, representing a relative error of less than 2.5% of its range of motion in each dimension.


Assuntos
Algoritmos , Imageamento Tridimensional , Microscopia/métodos , Imagens de Fantasmas , Humanos , Movimento (Física)
7.
Phys Rev Lett ; 122(13): 139402, 2019 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-31012621

Assuntos
Éter , Éteres
8.
Sci Rep ; 14(1): 14687, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38918443

RESUMO

Cameras with single-photon sensitivities can be used to measure the spatial correlations between the photon-pairs that are produced by parametric down-conversion. Even when pumped by a single-mode laser, the signal and idler photons are typically distributed over several thousand spatial modes yet strongly correlated with each other in their position and anti-correlated in their transverse momentum. These spatial correlations enable applications in imaging, sensing, communication, and optical processing. Here we show that, using a photon-number resolving camera, spatial correlations can be observed after only a few 10s of seconds of measurement time, thereby demonstrating comparable performance with previous single photon sensitive camera technologies but with the additional capability to resolve photon-number. Consequently, these photon-number resolving technologies are likely to find wide use in quantum, low-light, imaging systems.

9.
Opt Express ; 21(14): 16541-51, 2013 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-23938505

RESUMO

Spatial Light Modulators (SLMs) can emulate the classic microscopy techniques, including differential interference (DIC) contrast and (spiral) phase contrast. Their programmability entails the benefit of flexibility or the option to multiplex images, for single-shot quantitative imaging or for simultaneous multi-plane imaging (depth-of-field multiplexing). We report the development of a microscope sharing many of the previously demonstrated capabilities, within a holographic implementation of a stereo microscope. Furthermore, we use the SLM to combine stereo microscopy with a refocusing filter and with a darkfield filter. The instrument is built around a custom inverted microscope and equipped with an SLM which gives various imaging modes laterally displaced on the same camera chip. In addition, there is a wide angle camera for visualisation of a larger region of the sample.


Assuntos
Holografia/instrumentação , Aumento da Imagem/instrumentação , Imageamento Tridimensional/instrumentação , Iluminação/instrumentação , Microscopia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
10.
Opt Express ; 21(25): 30460-73, 2013 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-24514623

RESUMO

Ghost imaging and ghost diffraction can be realized by using the spatial correlations between signal and idler photons produced by spontaneous parametric down-conversion. If an object is placed in the signal (idler) path, the spatial correlations between the transmitted photons as measured by a single, non-imaging, "bucket" detector and a scanning detector placed in the idler (signal) path can reveal either the image or diffraction pattern of the object, whereas neither detector signal on its own can. The details of the bucket detector, such as its collection area and numerical aperture, set the number of transverse modes supported by the system. For ghost imaging these details are less important, affecting mostly the sampling time required to produce the image. For ghost diffraction, however, the bucket detector must be filtered to a single, spatially coherent mode. We examine this difference in behavour by using either a multi-mode or single-mode fibre to define the detection aperture. Furthermore, instead of a scanning detector we use a heralded camera so that the image or diffraction pattern produced can be measured across the full field of view. The importance of a single mode detection in the observation of ghost diffraction is equivalent to the need within a classical diffraction experiment to illuminate the aperture with a spatially coherent mode.

11.
Phys Rev Lett ; 110(14): 143601, 2013 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-25166985

RESUMO

Mutually unbiased bases (MUBs) play a key role in many protocols in quantum science, such as quantum key distribution. However, defining MUBs for arbitrary high-dimensional systems is theoretically difficult, and measurements in such bases can be hard to implement. We show experimentally that efficient quantum state reconstruction of a high-dimensional multipartite quantum system can be performed by considering only the MUBs of the individual parts. The state spaces of the individual subsystems are always smaller than the state space of the composite system. Thus, the benefit of this method is that MUBs need to be defined for the small Hilbert spaces of the subsystems rather than for the large space of the overall system. This becomes especially relevant where the definition or measurement of MUBs for the overall system is challenging. We illustrate this approach by implementing measurements for a high-dimensional system consisting of two photons entangled in the orbital angular momentum degree of freedom, and we reconstruct the state of this system for dimensions of the individual photons from d = 2 to 5.

12.
Phys Rev Lett ; 110(14): 143903, 2013 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-25166991

RESUMO

In this Letter we show that, in spectral regions where there are no orbital cladding resonances to cause transmission loss, the core mode of a continuously twisted photonic crystal fiber (PCF) exhibits optical activity, and that the magnitude of the associated circular birefringence increases linearly with twist rate and is highly reproducible. In contrast to previous work on twist-induced circular birefringence, PCF has zero linear birefringence and an on-axis core, making the appearance of circular birefringence rather unexpected. A theoretical model based on symmetry properties and perturbation theory is developed and used to show that both spin and orbital angular momentum play a role in this effect. It turns out that the degenerate left- and right-circularly polarized modes of the untwisted PCF are not 100% circularly polarized but carry a small amount of orbital angular momentum caused by the interaction between the core mode and the hollow channels.

13.
Opt Express ; 20(11): 12127-32, 2012 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-22714199

RESUMO

The viscosity of a fluid can be measured by tracking the motion of a suspended micron-sized particle trapped by optical tweezers. However, when the particle density is high, additional particles entering the trap compromise the tracking procedure and degrade the accuracy of the measurement. In this work we introduce an additional Laguerre-Gaussian, i.e. annular, beam surrounding the trap, acting as an optical shield to exclude contaminating particles.


Assuntos
Algoritmos , Nefelometria e Turbidimetria/instrumentação , Pinças Ópticas , Desenho de Equipamento , Análise de Falha de Equipamento , Viscosidade
14.
Opt Express ; 20(28): 29679-93, 2012 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-23388796

RESUMO

We demonstrate the use of an extended, optically trapped probe that is capable of imaging surface topography with nanometre precision, whilst applying ultra-low, femto-Newton sized forces. This degree of precision and sensitivity is acquired through three distinct strategies. First, the probe itself is shaped in such a way as to soften the trap along the sensing axis and stiffen it in transverse directions. Next, these characteristics are enhanced by selectively position clamping independent motions of the probe. Finally, force clamping is used to refine the surface contact response. Detailed analyses are presented for each of these mechanisms. To test our sensor, we scan it laterally over a calibration sample consisting of a series of graduated steps, and demonstrate a height resolution of ∼ 11 nm. Using equipartition theory, we estimate that an average force of only ∼ 140 fN is exerted on the sample during the scan, making this technique ideal for the investigation of delicate biological samples.


Assuntos
Óptica e Fotônica/instrumentação , Rotação , Propriedades de Superfície , Temperatura
15.
Opt Express ; 19(21): 20622-7, 2011 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-21997071

RESUMO

We investigate the degree of control that can be exercised over an optically trapped microscopic non-spherical force probe. By position clamping translational and rotational modes in different ways, we are able to dramatically improve the position resolution of our probe with no reduction in sensitivity. We also demonstrate control over rotational-translational coupling, and exhibit a mechanism whereby the average centre of rotation of the probe can be displaced away from its centre.


Assuntos
Pinças Ópticas , Óptica e Fotônica , Algoritmos , Desenho de Equipamento , Lasers , Micromanipulação/métodos , Modelos Estatísticos , Estresse Mecânico , Gravação em Vídeo
16.
Phys Rev Lett ; 106(10): 100407, 2011 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-21469778

RESUMO

Optical vortices are lines of phase singularity which percolate through all optical fields. We report the entanglement of linked optical vortex loops in the light produced by spontaneous parametric down-conversion. As measured by using a Bell inequality, this entanglement between topological features extends over macroscopic and finite volumes. The entanglement of photons in complex three-dimensional topological states suggests the possibility of entanglement of similar features in other quantum systems describable by complex scalar functions, such as superconductors, superfluids, and Bose-Einstein condensates.

17.
Nanotechnology ; 22(28): 285503, 2011 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-21646693

RESUMO

We present an imaging technique using an optically trapped cigar-shaped probe controlled using holographic optical tweezers. The probe is raster scanned over a surface, allowing an image to be taken in a manner analogous to scanning probe microscopy (SPM), with automatic closed loop feedback control provided by analysis of the probe position recorded using a high speed CMOS camera. The probe is held using two optical traps centred at least 10 µm from the ends, minimizing laser illumination of the tip, so reducing the chance of optical damage to delicate samples. The technique imparts less force on samples than contact SPM techniques, and allows highly curved and strongly scattering samples to be imaged, which present difficulties for imaging using photonic force microscopy. To calibrate our technique, we first image a known sample--the interface between two 8 µm polystyrene beads. We then demonstrate the advantages of this technique by imaging the surface of the soft alga Pseudopediastrum. The scattering force of our laser applied directly onto this sample is enough to remove it from the surface, but we can use our technique to image the algal surface with minimal disruption while it is alive, not adhered and in physiological conditions. The resolution is currently equivalent to confocal microscopy, but as our technique is not diffraction limited, there is scope for significant improvement by reducing the tip diameter and limiting the thermal motion of the probe.

18.
Sci Rep ; 11(1): 21841, 2021 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-34750423

RESUMO

Quantum illumination protocols can be implemented to improve imaging performance in the low photon flux regime even in the presence of both background light and sensor noise. However, the extent to which this noise can be rejected is limited by the rate of accidental correlations resulting from the detection of photon or noise events that are not quantum-correlated. Here we present an improved protocol that rejects up to [Formula: see text] of background light and sensor noise in the low photon flux regime, improving upon our previous results by an order of magnitude. This improvement, which requires no information regarding the scene or noise statistics, will enable extremely low light quantum imaging techniques to be applied in environments previously thought difficult and be an important addition to the development of covert imaging, quantum microscopes, and quantum LIDAR.

19.
Opt Express ; 18(25): 26084-91, 2010 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-21164957

RESUMO

We present tailoring of three dimensional light fields which act as light moulds for elaborate particle micro structures of variable shapes. Stereo microscopy is used for visualization of the 3D particle assemblies. The powerful method is demonstrated for the class of propagation invariant beams, where we introduce the use of Mathieu beams as light moulds with non-rotationally-symmetric structure. They offer multifarious field distributions and facilitate the creation of versatile particle structures. This general technique may find its application in micro fluidics, chemistry, biology, and medicine, to create highly efficient mixing tools, for hierarchical supramolecular organization or in 3D tissue engineering.


Assuntos
Lasers , Iluminação/métodos , Pinças Ópticas , Luz , Tamanho da Partícula , Espalhamento de Radiação
20.
Nanotechnology ; 21(17): 175501, 2010 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-20368683

RESUMO

Holographically trapped nanotools can be used in a novel form of force microscopy. By measuring the displacement of the tool in the optical traps, the contact force experienced by the probe can be inferred. In the following paper we experimentally demonstrate the calibration of such a device and show that its behaviour is independent of small changes in the relative position of the optical traps. Furthermore, we explore more general aspects of the thermal motion of the tool.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA